tender for distribution panel , supply,replacement and fixing multifunction or intelligent meter in mv, lt,mv,lt, distribution panel , supply, replacement and fixing 10 kvar capacitor type md02 in existing mv, lt, distribution panels , supply, replacement and fixing ac voltmeter 0-600v class1.0, 144 sq. mm. in existing panels , supply, replacement and fixing ac ammeter, 0 to 600 amp class 1.0, 144 sq, mm size in existing panels , supply, replacement and fixing ammeter selector switch, 3 pole and off, 6a in existing panels , supply, replacement and fixing voltmeter selector switch, 3 pole and off, 6 a in existing panels , supply, replacement and fixing operating handle for mccb 100 amp to 400 amp in existing panels , supply, replacement and fixing fuse carrier with fuse link, 100 amp in existing panels , supply, replacement and fixing hrc fuse link 100 amp in existing panels etc complete as required , supply, replacement and fixing cfl lamp , pl l 4p lamp 36 w in existing fittings, , supplying, replacement and fixing 5 or 6 a switch, piano type, on the sb, cover, panel db etc , supplying, replacement and fixing 15 or 16 a switch, piano type, on the sb, cover, panel db etc , supplying, replacement and fixing 3 pin 5 or 6 a socket outlet, piano type, on the sb etc. as required , supplying, replacement and fixing sp mcb, 5 to 32 a, c series, on the sb, cover, panel db as reqd , repairs of ceiling fan 1200 or 1400 mm incl. dismantling, servicing, rewinding, reinstallation as reqd. , repairs of exhaust fan 450 mm incl. dismantling, servicing, rewinding, reinstallation as reqd. , supply, replacement and fixing 1400 mm ceiling fans complete as reqd. , repairing, rewinding of 2 hp sump pump set including greasing, varnishing, motor bush, etc as reqd. , supplying, fixing , replacement of faulty spares l rewinding of charging alternator for 380 kva ea , supplying, replacement and fixing of radiator fan v belt set compatible 380 kva ea set etc as reqd , supplying, replacement and fixing 12mm dia wire braided pvc diesel pipe compatible for 380 kva ea. , supplying, replacement and fixing ac ammeter 96 sq.mm, 0 to 200 a or 400 a for 380 kva ea as reqd. , supplying, replacement and fixing led indicator lamps, 230 v, r, y and g for 380 kva ea set. , carrying out repair incl.replacement of ecp control panel sefety control, for 125 kva ea as reqd. , carrying out repair incl. replacement, rectification of oil leakage from drain nut for 125kva ea , carrying out repair incl.replacement of stop solenoid valve with solenoid switch for 125 kva ea set , carrying out repair including replacement of spares and rewinding for 125kva ea set as reqd. , carrying out repairs of radiator incl. servicing, cleaning, and attending minor leakage in 125 ea. , carrying out repair including replacement for carry out b check servicing for existing 125 kva ea , carrying out repair inc.replacement led indicator lamps, 230 v, r, y and g for 125kva ea as reqd. , carrying out repair incl. replacement of dc voltmeter 72 sq.mm, 0 to 50 volt for 125kva ea as reqd. , carrying out repair incl.replacement of ac ammeter 96 sq.mm, 0 to 200 amp or 400 amp for 125kva ea. , carrying out repair incl.replacement ammeter and voltmeter selector switch for 125kva ea as reqd. , supplying, replacement and fixing of 12v, 7ah battery compatible for fd and fa system etc as reqd. , supplying, replacement and fixing smoke detector with built in led and mounting base. etc as reqd , supplying, replacement and fixing response indicator on surface or, ocm of ems telecom compound yerawada pune attending defects, supplying, replacement and fixing potential transformer of rating 11kv by 110v, 100va class1 in 11kv ht panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing ammeter with range 0 to 20a, 144 mm x 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing voltmeter with range 0 to 15kv, 144 mm x 144 mm size in existing panel including installations, connections, testing and commissioning etc complete as reqd, supplying, replacement and fixing led type indicators lamp yellow, red, blue and green in colour including testing etc complete as reqd., supplying, replacement and fixing trivector meter including testing etc complete as reqd., heater rectification in 11kv ht panel of bieco lawrie including testing etc complete as reqd., supplying, replacement and fixing selector switch including testing etc complete as reqd., servicing of oil circuit breaker in 11kv ht panel of bieco lawrie including testing etc complete as reqd., service, maintenance and rectification of cable chattering, contact surface conditioning and associated works for transformer no. 2 busbar trunking links in ht panel, testing commissioning as reqd., supplying, replacement and fixing of marshalling box lock for 500 kva indoor transformer of kirloskar make complete as reqd., supplying, replacement and fixing of box cover gasket for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of marshalling box glass for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and toping of transformer oil for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing silica gel breather for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of transformer conservator oil gauge for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., supplying, replacement and fixing of transformer temparature gauge for 500 kva indoor transformer of m/s. kirloskar including testing etc complete as reqd., servicing and repairing of 800 to 250 amp. air circuit breakers incl.draw out from existing panel, cleaning of jaw contact and arcchut by using crc or wd40 proper alignment and testing etc as required, supply, replacement and fixing indicators lamp yellow, red and green colour in existing mv, lt, distribution panels including testing etc complete as required., supply, replacement and fixing indicators lamp blue colour in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing multifunction or intelligent meter in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing 10 kvar capacitor type md02 in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ac voltmeter having range 0 to 600v class 1.0 accuracy, 144 sq. mm size in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ac ammeter having range 0 to 600 amp class 1.0, 144 sq. mm size in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing ammeter selector switch, 3 pole and off, 6a in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing voltmeter selector switch, 3 pole and off, 6 a in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing operating handle for mccb 100 amp to 400 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing fuse carrier with fuse link, 100 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing hrc fuse link 100 amp in existing mv, lt, distribution panels including testing etc complete as required, supply, replacement and fixing cfl lamp, pl l 4p lamp 36 w in existing fittings, fitting type 2 x 36 w cfl master pl l 36w l 865l4p 1ctl25) etc complete as required., supplying, replacement and fixing 5 or 6 amps switch, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing 15 or 16 amps switch, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing 3 pin 5 or 6 a socket outlet, piano type, on the switch board, cover, panel db including connections etc. as required, supplying, replacement and fixing sp mcb, 5 to 32 a, c series, on the switch board, cover, panel db including connections etc. as required, repairs of existing ceiling fan,1200 mm or 1400 mm incl. dismantling, servicing, rewinding, replacement of bearings, capacitor, to and fro transportation to repair, necessary reinstallation as reqd., repairs of existing exhaust 450 mm incl. dismantling, servicing, rewinding, replacement of bearings, capacitor, to and fro transportation to repair, necessary reinstallation as reqd., supply, replacement and fixing 1400 mm sweep ceiling fans complete as reqd., repairing, rewinding of 2 hp sump pump set including greasing, varnishing, replacement of motor bush, nut bolts and gland packing transportation loading, unloading testing comm. etc as required., supplying, fixing, replacement of faulty spares and rewinding of charging alternator of same make, model and compatible for existing 380 kva ea set, cummins make with itc etc complete as reqd., supplying, replacement and fixing of radiator fan v belt set of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as required, supplying, replacement and fixing 12mm dia wire braided pvc diesel pipe of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, supplying, replacement and fixing ac ammeter 96 sq.mm, 0 to 200a or 400a of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, supplying, replacement and fixing led indicator lamps, 230 v, r, y and g of same make, model and compatible for existing 380 kva ea set, with installation, connection, testing, commissioning as reqd, carrying out repair incl. replacement of ecp control panel sefety control, rectification incl. mechanical operation for 125 kva ea set kirloskar make with testing, commissioning etc as reqd., carrying out repair including replacement , rectification of oil leakage from drain nut for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement of stop solenoid valve with solenoid switch for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement of spares and rewinding for existing 125kva ea set kirloskar make with installation, testing, commissioning as reqd., carrying out repairs of radiator including servicing, cleaning, and attending minor leakage for existing 125kva ea set with installation, testing, commissioning as reqd., carrying out repair including replacement, b check servicing for existing 125 kva ea set kirloskar make with testing etc complete as reqd., carrying out repair including replacement led indicator lamps, 230 v, r, y and g for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement dc voltmeter 72 sq.mm size, 0 to 50 volt for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement ac ammeter 96 sq.mm size, 0 to 200 amp or 400 amp for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., carrying out repair including replacement ammeter and voltmeter selector switch for existing 125 kva ea set kirloskar make with installation, testing, commissioning etc as reqd., supplying, replacement and fixing of 12v 7ah battery same make, model and compatible for existing fire detection and fire alarm system with connections, testing and commissioning complete as reqd., supplying, replacement and fixing of smoke detector with built in led and mounting base complete compatible for existing fd and fa system with testing & commissioning complete as reqd., supplying, replacement and fixing response indicator on surface or recess ms box having two leds metallic cover compatible for existing fd and fa system with testing, commissioning complete as reqd., supplying, replacement and fixing hammer, chain compatible for existing fd and fa system with testing, commissioning complete as reqd., supplying, replacement and fixing exit sign board compatible for existing fd and fa system with testing, commissioning complete as reqd., repairs of existing 7 tr conventional package ac twin ckt, singhson make incl. supplying, charging and topping of r22 refrigerent gas with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac, twin ckt, singhson make incl. replacement hp and lp cut out in the refrigerant circuit pu 1 and 2 with testing, commissioning complete as reqd., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of hp gauge of pu 1 and 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of lp gauge with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement thermostat with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement condenser motor 1ph, 0.5hp for pu 1 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of filter drier of pu 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of overload relay of pu 1 and 2 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of pla relay of pu 1 with testing, commissioning complete as required., repairs of existing 7 tr conventional package ac twin ckt, singhson make including replacement of on delay timer of pu 1 and pu 2 with testing, commissioning complete as required., repairs to the control wiring including replacement of circuit components, wiring, etc. if necessary for satisfactory operation of the package ac unit complete as required. for pu 1 and 2