Latest Tender Detail from bharat sanchar nigam limited BSNL for the tender for with 2000 lumen , rewinding of ceiling fan motors with sweep up to 1400 mm , rewinding of exhaust fan motors with sweep up to 450 mm , rewinding of pedestal fan motors with sweep up to 450 mm , replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard , replacement of faulty piano switch 5 or 6 amp on the existing switchboard , replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard , replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard , replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db , replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db , refilling of existing 4.5kg, co2 type fire extinguisher , repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable , supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay i , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25 a 415 v tp contactor, mnx25, ac3 rating suitable for din rail mount , repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing , supplying and charging or topping of r 22 refrigerant gas , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty, ocm of ems at te bldg and staff qtrs at chd pune sh attending defects at rnc, supplying and fixing of led indicators red, yellow, blue or green of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels etc as reqd., supplying and fixing of ac ammeter 0 to 200a class 1, analog 96mm size of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd, supplying and fixing of ac voltmeter 0 to 500v class 1, analog 96 mm of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of hn type 63 a fuse link compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of voltmeter selector switch of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of 100 a, 415 v, 4 pole isolator of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., servicing and repairing of 800 a, air circuit breakers of c and s make including draw out from panel cleaning of jaw contact and arc chut by using crc or wd40, proper alignment, testing etc as reqd., repairing and calibration of existing apfc relay of syntron make for 135 kvar capacitor panel including auto mode operation and on load testing etc complete as reqd., attending oil leakage of 22kv, 500kva transformer voltamp make, with highgrade oil resistant nitrile or rc70c neoprene bonded cork gaskets incl. supply and top up of 10 ltr of ehv grade mineral oil., carrying out repair or replacement of llop switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of water temperature switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of digital rpm cum hour meter suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of brass battery terminal with copper lugs for 1 battery with installation, connection, testing, commissioning as reqd., attending leakage in exhaust silencer flexible bellow with brazing or repairing or replacement of existing 500 kva ea set of greaves make etc as reqd., carrying out repair or replacement of charging alternator incl. replacement of components or rewinding of existing 500 kva ea set of greaves make with inst., connection, testing, commissioning etc., attending engine oil leakage of top head and rocker cover engine, fuel pump, tank, fuel valves of 500 kva greaves dg set having engine model tbd 4iv12p, with all genuine greaves cotton spares etc., carrying out servicing, chemical descaling and high-pressure jet cleaning of the radiator of 500 kva dg set incl. dismantling radiator, replacement of rubber hoses and clamps, coolant top up etc., repairing, rewinding of 7.5hp beacon make centrifugal pump set incl. greasing, varnishing, replac. of wornout bearings and gland packing incl. dismantling, handling, transp. and reinstallation etc., replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve, with all accessories including testing commissioning etc complete as required, repairing of 1.5 tr split ac units by replacement or repair of blower motor for indoor unit of voltas make with connections, testing, commissioning etc as reqd., repairing of 1.5 tr split ac units by attending of leakage incl. brazing or flaring the leak points, vacumising, purging flushing and supplying and charging of r22 or r410 or r134 refrigerant gas etc, supply and fixing 20 watt aluminium led batten tubelight with 2000 lumen for commercial use on wall or ceiling incl. testing commissioning etc complete as required, rewinding of ceiling fan motors with sweep up to 1400 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd, rewinding of exhaust fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., rewinding of pedestal fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty piano switch 5 or 6 amp on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db including connections, testing and commissioning as reqd., refilling of existing 4.5kg, co2 type fire extinguisher including to and fro transportation including replacing faulty horn, hose pipe, hydraulic pressure testing, cleaning, labelling etc. as reqd., repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable from pole junction box to fitting etc. complete as reqd., supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground as strip earth electrode, including connection with gi nut, bolt, spring washer etc. as required., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25a 415v tp contactor, mnx25, ac3 rating suitable for din rail mount incl. wiring, connection, testing as reqd, repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing, testing and commissioning etc as reqd, supplying and charging or topping of r 22 refrigerant gas in existing 7 tr package ac units etc compete as required, repair of 7tr conventional package ac unit of singhson make by replacement of the faulty condenser fan motor 1 phase, 0.5hp motor including wiring, connections, testing, commissioning etc as reqd. in pune, maharashtra,. Reference number 16239962. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.