Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

28Latest Fire damper Tenders List

Latest Fire damper Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Fire damper tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Fire damper tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Fire damper Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Fire damper tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Fire damper Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Fire damper Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Fire damper Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Fire damper tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Fire damper Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Fire damper sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Fire damper tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Fire damper tenders.

Is EMD mandatory for all Fire damper tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Fire damper work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Fire damper tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Fire damper Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 16684356
Location : kolhapur , maharashtra
Source : GEM Tenders
LIVE TENDER
tender for supply of 5.5 tr inverter type ductable aircooled split ac units , itc of 5.5 tr inverter type ductable aircooled split ac units , s and f for hot gas line in single circuit with suitable size cu refrigerant piping , s and f for liquid line in single circuit with suitable size cu refrigerant piping , p and f of ducting made out from 24 swg gi sheet , p and f of ducting made out from 22 swg gi sheet , p and f of powder coated al air grills with volume control damper , p and f of powder coated al air grills without volume control damper , pvdg and fixing of canvas duct connection made out of fire retardent canvas cloth and flanges , s and l of 4 core 6 sq. mm copper conductor armoured cable , s and l of 6 core 1.5 sq. mm copper conductor armoured cable , s and f 25 mm dia cpvc drain pipe , p and f ms structure for outdoor unit ref pipes and cables , s and installation of 150 mm width x 50 mm depth x 1.6 mm thickness size perforated hot dipped gi cable trays , p and f 8 swg dia gi wire, supply installation testing and commissioning of 20 nos 5 point 5 tr inverter type ductable aircooled split ac units in mh and goa states, supply of 5.5 tr of capacity minimum 66000 btu per hr and eer shall not be less than 10 btu per watt hr inverter type ductable aircooled split ac unit, itc of 5.5 tr inverter type ductable aircooled split ac unit including required steel support structure with minor civil work and making good the damages etc complete as required., s and f for hot gas line in single circuit with suitable size cu refrigerant piping of min 18g i.e. 1.2 mm thickness incl. insulating refrigerant line with fire retardant polythene foam etc, s and f for liquid line in single circuit with suitable size cu refrigerant piping of min 18g i.e. 1.2 mm thickness incl. insulating refrigerant line with fire retardant polythene foam etc, providing and fixing of suitable size ducting made out from 24 swg gi sheet alongwith suitable collers steel supports suspenders and fastners etc, providing and fixing of suitable size ducting made out from 22 swg gi sheet alongwith suitable collers steel supports suspenders and fastners etc, providing and fixing of powder coated aluminium air grills with volume control damper of required sizes etc, providing and fixing of powder coated aluminium air grills without volume control damper of required sizes etc, providing and fixing of canvas duct connection made out of fire retardent canvas cloth and flanges on both ends for connecting ductable ac unit with existing duct incl pvdg openable chain zip, supply and laying of 4 core 6 sq. mm copper conductor 650 or 1100 v grade pvc or xlpe armoured cable, supply and laying of 6 core 1.5 sq. mm copper conductor 650 or 1100 v grade pvc or xlpe armoured cable, s and f of 25 mm dia isi mark cpvc pipe with accessories for drain water connection incl. insulating cpvc pipe inside ac area with suitable fire retardant polythene foam etc as reqd, providing and fixing ms structure for outdoor units ref. pipes and cables made out of solid channels angles flats etc incl. cutting, welding, painting etc complete as reqd., s and installation of 150mm width x 50mm depth x 1.6mm thickness size perforated hot dipped gi cable trays incl. connectors or bends or tees or cross members gi suspenders incl gi bolts and nuts etc as reqd, providing and fixing 8 swg dia gi wire on surface or in recess for loop earthing along with existing surface or recessed conduit or submain wiring or cable as reqd.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16667315
Location : mumbai , maharashtra
Source : GEM Tenders

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15863311
Location : coimbatore , tamil nadu
Source : GEM Tenders
corrigendum tender for supply installation testing and commissioning of fire dampers , supply installation testing and commissioning of fire dampers in supply air duct actuator torque 9nm, 230v. , supply installation testing and commissioning of fire dampers in supply air duct actuator torque 20nm, 230v. , supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular ducting 0.8 mm thick , supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular ducting 1.00 mm thick , supply and fixing of acoustic lining , supplying and fixing nitrile rubber insulation 19 mm , dismantling of old airconditioning ducts , supply installation testing and commissioning of control panel for 230v actuator. , supply installation testing and commissioning of ahu tripping panel , supply of 2x1.5 sqmm copper control cables , laying and fixing cable tray , laying and fixing of xlpe power cable of 1.1 kv on wall surface upto 35 sq. mm , supplying and making end termination , integration of all devices for activiation of ahu, provision of automatic fire dampers, supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. fire damper, supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. actuator torque 9nm, 230v., supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. actuator torque 20nm, 230v., supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. site fabricated gss sheet metal rectangular ducting as per is 655 2006 0.8 mm thick, supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular or round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. site fabricated gss sheet metal rectangular ducting as per is 655 2006 1.00 mm thick, supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg or meter cube, with 25 mm x 25 mm gi section of 1.25 mm thick, at 600 mm centre to centre covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, cprx compound etc., supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber class o insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. nitrile rubber insulation 19 mm, dismantling of old airconditioning ducts from the ac system including removal of insulations, supports etc. complete to make provision for connection of fire damper and shifting the same to dismantled stores of aai., supply, instalation, testing and commissiong of control panel for 230v actuator., supply, installation, testing and commissiong of ahu tripping panel in sheet steel enclosure consists of intelligent addressable input or output loop powered relay module, volt free contacts suitable for functioning via fire alarm loop., supply of 2x1.5 sqmm copper control cables, xlpe insulated, pvc innersheathed, armoured, extruded pvc type st2 sheathed, 650 v or 1100 v grade as per is 7098 part 1 1988., laying and fixing of one number pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq.mm., laying and fixing of one pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle., supplying and making end termination with brass compression gland and copper lugs for following size of pvc insulated and pvc sheathed or xlpe copper conductor cable 1.1 kv grade as required., integration of all devices for activiation of ahu tripping in the event of fire detection, interfacing with the existing fire dedection system including installation or modification or upgradation of program of all fire alarm panels in the system, testing and commissioning of the system complete as required and as per the direction of the enginner in charge. the scope of work also includes dismantling of unwanted bms devices from the system wherever required.
T18 Ref No : 16588312
Location : coimbatore , tamil nadu
Source : GEM Tenders
tender for supply installation testing and commissioning of fire dampers , supply installation testing and commissioning of fire dampers in supply air duct actuator torque 9nm 230v. , supply installation testing and commissioning of fire dampers in supply air duct actuator torque 20nm, 230v. , supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular ducting 0.8 mm thick , supply, installation, balancing and commissioning of fabricated at site gss sheet metal rectangular ducting 1.00 mm thick , supply and fixing of acoustic lining , supplying and fixing nitrile rubber insulation 19 mm , dismantling of old airconditioning ducts , supply installation testing and commissioning of control panel for 230v actuator. , supply installation testing and commissioning of ahu tripping panel , supply of 2x1.5 sqmm copper control cables , laying and fixing cable tray , laying and fixing of xlpe power cable of 1.1 kv on wall surface upto 35 sq. mm , supplying and making end termination , integration of all devices for activiation of ahu, fire damper, supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. fire damper, supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. actuator torque 9nm, 230v., supplying, fixing,testing and commissioning of fire dampers in supply air duct or main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and not externally mounted. the damper shall also be closed in the event of fire signal complete as required and as per specifications. actuator torque 20nm, 230v., supply installation balancing and commissioning of fabricated at site gss sheet metal rectangular or round ducting complete with neoprene rubber gaskets elbows splitter dampers vanes hangers supports etc. as per approved drawings and specifications of following sheet thickness complete as required. site fabricated gss sheet metal rectangular ducting as per is 655 2006 0.8 mm thick, supply installation balancing and commissioning of fabricated at site gss sheet metal rectangular or round ducting complete with neoprene rubber gaskets elbows splitter dampers vanes hangers supports etc. as per approved drawings and specifications of following sheet thickness complete as required. site fabricated gss sheet metal rectangular ducting as per is 655 2006 1.00 mm thick, supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg or meter cube with 25 mm x 25 mm gi section of 1.25 mm thick at 600 mm centre to centre covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts bolts stick pins cprx compound etc. complete as required and as per specifications., supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber class o insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. nitrile rubber insulation 19 mm, dismantling of old airconditioning ducts from the ac system including removal of insulations supports etc. complete to make provision for connection of fire damper and shifting the same to dismantled stores of aai., supply instalation testing and commissioning of control panel for 230v actuator., supply installation testing and commissiong of ahu tripping panel in sheet steel enclosure consists of intelligent addressable input or output loop powered relay module volt free contacts suitable for functioning via fire alarm loop., supply of 2 x 1.5 sqmm copper control cables xlpe insulated pvc innersheathed armoured extruded pvc type st2 sheathed 650 v or 1100 v grade as per is 7098 part 1 1988., laying and fixing of one number pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq.mm., laying and fixing of one pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle., supplying and making end termination with brass compression gland and copper lugs for following size of pvc insulated and pvc sheathed or xlpe copper conductor cable 1.1 kv grade as required., integration of all devices for activiation of ahu tripping in the event of fire detection interfacing with the existing fire dedection system including installation or modification or upgradation of program of all fire alarm panels in the system testing and commissioning of the system complete as required and as per the direction of the enginner in charge. the scope of work also includes dismantling of unwanted bms devices from the system wherever required.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Fire Damper. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Fire Damper sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Fire Damper Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Fire Damper, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Fire Damper Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Fire Damper Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Fire Damper.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Fire Damper depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Fire Damper Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Fire Damper bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Fire Damper. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Fire Damper, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Fire Damper, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Fire Damper?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Fire Damper tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Fire Damper?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Fire Damper, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Fire Damper is declared L1 and is generally awarded the contract