Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

16Results forLatest Signaling cable laying Tenders List

Latest Signaling cable laying Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Signaling cable laying tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Signaling cable laying tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Signaling cable laying Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Signaling cable laying tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Signaling cable laying Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Signaling cable laying Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Signaling cable laying Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Signaling cable laying tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Signaling cable laying Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Signaling cable laying sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Signaling cable laying tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Signaling cable laying tenders.

Is EMD mandatory for all Signaling cable laying tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Signaling cable laying work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Signaling cable laying tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Signaling cable laying Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16194957
live Tender
Location : mathura , uttar pradesh
Source : GEM Tenders
live Tender

tender for and installation non return valve nrv of ci of size 65 mm as per latest is and description , supply and installation non return valve nrv of ci of size 50 mm as per latest is and description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description , supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description , supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description , supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description , gi pipe medium grade of 50 mm dia , gi pipe medium grade of 20 mm dia , gi pipe medium grade of 15 mm dia , supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description , m and l for duct insulation with 25 mm thick all as per description , m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation , m and l for supply air grilis with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation , m and l for return air grills with extruder aluminium powder coated without air volume control shall be provided as per oem recommendation , dismantling old false ceiling any type as per description , supply and installation 3 way valve of ci of size 80 mm dia , demolition of brick work or floor as per description , m and l for brick work with sub class b brick straight or curved as per description , m and l for plastering 12 mm thick on fair faces of brick as per description , m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed , m and l for 100 mm bore steel tubing light grade complete all as specified and as directed , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground with 32 x 6 mm gi strip , supply installation testing and commissioning of lt control panel board cubical type indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca, special repair to replacement of 03 x 25 central ac plant in signal centre under ge west mathura, disconnecting and taking down complete central ac plant capacity 25 tr x 3 nos with ahu 01 cooling tower duct and complete connected accessories as per description, design and supply installation testing and commissioning of central ac plant of working capacity not less than 2 x 25 tr working plus 1 stand by as per design and description, supply installation commissioning and testing of monoblock centrifugal pump 2 w plus 1 s of capacity suitable for 50 tr central ac plant and design by oem, supply installation commissioning 440 v 50 hz of monoblock centrifugal pump 2 w plus 1 s of capacity suitable for 50 tr central ac plant and design by oem, supply installation commissioning and testing of frp cooling tower rectagular round bottle shape suitable for capacity 50 tr ac plant with frp body and design by oem, supply installation testing and commissioning of factory built ahu with six row deep coil suitable for 50 tr as per oem recommendation, supply and installation hot water generator 35 kw with 2 nos pump 1 w plus 1 s alongwith making necessary connections complete all as per oem recommendation, supply and fixing mild steel c grade pipe heavy duty of dia 100 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 80 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 65 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 50 mm all as per description, supply and installation butterfly valve of ci of size 100 mm as per latest is and description, supply and installation butterfly valve of ci of size 80 mm as per latest is and description, supply and installation butterfly valve of ci of size 65 mm as per latest is and description, supply and installation butterfly valve of ci of size 50 mm as per latest is and description, supply and installation non return valve nrv of ci of size 80 mm as per latest is and description, supply and installation non return valve nrv of ci of size 65 mm as per latest is and description, supply and installation non return valve nrv of ci of size 50 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description, supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description, supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description, supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description, gi pipe medium grade of 50 mm dia, gi pipe medium grade of 20 mm dia, gi pipe medium grade of 15 mm dia, supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description, m and l for duct insulation with 25 mm thick all as per description, m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation, m and l for supply air grilis with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation, m and l for return air grills with extruder aluminium powder coated without air volume control shall be provided as per oem recommendation, dismantling old false ceiling any type as per description, supply and installation 3 way valve of ci of size 80 mm dia, demolition of brick work or floor as per description, m and l for brick work with sub class b brick straight or curved as per description, m and l for plastering 12 mm thick on fair faces of brick as per description, m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed, m and l for 100 mm bore steel tubing light grade complete all as specified and as directed, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed, m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground with 32 x 6 mm gi strip, supply installation testing and commissioning of lt control panel board cubical type indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca sheet ae per drawing.


Agency / Dept : indian army
Tender Value : 0
Due Date : Jul 20, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15285750
Location : mathura , uttar pradesh
Source : GEM Tenders

corrigendum tender for description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description , supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description , supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description , supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description , gi pipe medium grade of 50 mm dia , gi pipe medium grade of 20 mm dia , gi pipe medium grade of 15 mm dia , supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description , m and l for duct insulation with 25 mm thick all as per description , m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation , m and l for supply air grilis with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation , m and l for return air grills with extruder aluminium powder coated without air volume control shall be provided as per oem recommendation , dismantling old false ceiling any type as per description , supply and installation 3 way valve of ci of size 80 mm dia , demolition of brick work or floor as per description , m and l for brick work with sub class b brick straight or curved as per description , m and l for plastering 12 mm thick on fair faces of brick as per description , m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed , m and l for 100 mm bore steel tubing light grade complete all as specified and as directed , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground with 32 x 6 mm gi strip , supply installation testing and commissioning of lt control panel board cubical type indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca, special repair to replacement of 03 x 25 central ac plant in signal centre under ge west mathura, disconnecting and taking down complete central ac plant capacity 25 tr x 3 nos with ahu 01 cooling tower duct and complete connected accessories as per diiscription, design supply installation testing and commissioning of central air conditioning plant of working capacity not less than 2 x 25 or 26 tr working pluse 1 stand by as per design provided by bidder all as per diiscription, supply installation commissioning and testing of monoblock centrifugal pump 2 w pluse1 s of capacity suitable for 50 tr central ac plant and design by vendor, supply installation commissioning 440 v 50 hz of monoblock centrifugal pump 2 w pluse 1 s of capacity suitable for 50 tr central ac plant and design by vendor, supply installation commissioning and testing of frp cooling tower rectagular round bottle shape suitable for capacity 50 tr ac plant with frp body and design by vendor, supply installation self commissioning and testing of factory built double skinned sandwiched with 25 mm fiber glass or thermo coal or puff insulation section type horizontal ahu with six row deep coil suitable for 50 or 52 tr as per description, supply and installation hot water generator 35 kw with 2 nos pump 1 w pluse1 s alongwith making necessary connections complete all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 100 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 80 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 65 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 50 mm all as per description, supply and installation butterfly valve of ci of size 100 mm as per latest is and description, supply and installation butterfly valve of ci of size 80 mm as per latest is and description, supply and installation butterfly valve of ci of size 65 mm as per latest is and description, supply and installation butterfly valve of ci of size 50 mm as per latest is and description, supply and installation non return valve nrv of ci of size 80 mm as per latest is and description, supply and installation non return valve nrv of ci of size 65 mm as per latest is and description, supply and installation non return valve nrv of ci of size 50 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description, supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description, supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description, supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description, gi pipe medium grade of 50 mm dia, gi pipe medium grade of 20 mm dia, gi pipe medium grade of 15 mm dia, supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description, m and l for duct insulation with 25 mm thick all as per description, m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation, m and l for suitable size of supply air grilis as per size of supply air grills as per manufacturers design with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation, providing suitable size of return air grills as per manufacturers design with extruder aluminium powder coated without air volume control and size of return air grills shall be provided as per oem recommendation, dismantling old false ceiling any type as per description, supply and installation 3 way valve of ci of size 80 mm dia, demolition of brick work or floor as per description, m and l for brick work with sub class b brick straight or curved as per description, m and l for plastering 12 mm thick on fair faces of brick as per description, m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed, m and l for 100 mm bore steel tubing light grade complete all as specified and as directed, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground rate for gi strip and protection pipes upto 7 poinr 5 mtr shall be inclussive in rate to be quoted against this items., supply installation testing and commissioning of lt control panel board cubical type 415 volt 3 phase 50 hz indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca sheet ae per drawing


Agency / Dept : indian army
Tender Value : 0
Due Date : May 29, 2026
T18 Ref No : 15286275
Source : GEM Tenders

tender for xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply, installing, testing and commissioning of pdb panel 800a, 415v. the panel shall be indoor wall mounted. it shall be completely made of crca sheet steel. , supply, installing, testing and commissioning of pf correction panel with rms 430kvar, 415v. panel indoor floor mounted, free standing with ip-31 degree of ip made of crca sheet steel. , material and labour for xlpe insulated, lt armoured electric sense cable with aluminiur star ded conductor 1100 volts grade, cross- sectional area 4 sqmm, 6 core , m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed , supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying cif cables, pipe lines, protection pipes , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed , material and labour for earthing complete with copper plate electrode 600mmx 600mmx. 3.1.5 mm thick buriel directely in ground vertically , supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , civil work rcc panel base slab size - 2000mm l x 1300mm w x 150mm thickness , warranty service amc by cmc including breakdown service for 1 year to ensure the safe, reliable, and efficient operation of the electrical panel, provision of solar factor correction for 1 mw solar plant, the enclosure shall have sturdy support structure with angle suppors as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the panel shall be suitably sized to accommodate all the compor ents, providing necessary air clearance between live and non-live parts, providing necessary working clearance. incomer shall pe al busbars. power outgoing shall be one 800a, 415v, 50ka, tp, mccb, tm. bus bar shall be of aluminium with 0.8a by sq. mm current dens ty. suitable indication lamps for - phase supply indication and circuit elreaker - trip indication should be provided. mccbs shall be with door inter ocking protection systems. bus bars shall have coloured pvc sleeves. 800a outgoing shall be used to feed the 430kvar, 415v step-less pf correction system complete all as specified anc directed, the enclosure shall have sturdy support structure with angle supports as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the step-leiss pf correctior panel system shall be without any pf correction passive capacitor banks, but single or mutiple module combination of static var generator, which can measure the actual requirement of reactive currents and produce and inject the same reactive currents inductive or capacit ve as per the system needs to compensate the reactive power demand individual phase -wise. there shall be one hill cum svg controller digital signal processor to sense the load current and operate the svg modules connected with the svg panel. reaction time of that dsp shall be 10 msec, so that cycle to cycle compensation to be established. the hmi display unit shall have 15channel oscilloscope to display live-status of the 3phase voltage, load current, grid current and svg currents, along with all major electrical pq parameters. svg modules should have efficiency of less than 98 percent and internal losses 2 percent of its full capacity. the svg modules shall have internal fan for heat dissipation by force air cooling method. maximum 50 no.s modules can be connected in parallel per ct set. the svg modules should be operated within the voltage range 350v to 480v. ambient temperature should be 0-45 temp c. noise level shall be 5db. built-in semiconductor-fuse protection for the svg modules is a must. load ct shall have 5a secoridary and in general it will be connected in close loop. full rating of individual static var generator moclule shall be 125kvar, 480v, 1504, which will output 107.8kvar at 415v ac. so, considering the 4nos of modules it will output 431.2kvar at 415v., laid in trenches by pipes by ducts by wall by boarings with necessary cable lugs and glands, nuts, bolts and washers etc and test ng complete all as specified and directed, m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed, supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover complete all as specified in ssr part-l and as directed, foundations etc and getting out in soft loose soil complete all as specified and directed., returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed, remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres belcw ground level, connected to and including coper strip of size 20 x 3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-l and gl watering pipe of 20 mm dia medium grade, gi funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1-3-6 lype c1, rcc cover 1-2-4 type b1, ncluding excavation by earth work in any strata and returning filling, removal of surplus soil anc testing for required value complete all as specified and directed., supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed, concrete grade -m25 mix ratio 1-2-1 - cement- sand- aggregate bot om reinforcement 12mm dia. tmt bars placed at - 150mm centre-to-centre spacing in both directions both ways top reinforcement- 10mm dia. tmt bars placed at 200mm centre-to-centre spacing in both directions both ways edge stirrups 8mm dia tmt bars placed at 200mm centre-to-centre spacing in both directions both way formwork proper shuttering to be provided to achieve specified dimensions and line and level. total load 700kg or 6.9kn. cable trench 300mmx300mm and ms chequered plate cover for trench. base plate- ms charinel by flat ismc 100 or 10mm thick plate. curing - minimum 7 cays of water curing or as per is 4-56 recommendat ons plastering over base slab plaster mix cement mortar 1-6 - cement- sand finish- surface to be finished with neat cement punning after plastering as required preparation surface to be cleaned and wetted before application. proper bonding and uniformity to be ensured cutting and mending in brick wall scope- cutting holes in brick walls for service entries pipes, cables, etc. maximum diameter up to 150mm mending work- all damages to be made good using cement mortar cernent consumption approx. 4 kg per meter of hole length as per estimate restoration to match existing finish plaster or paint, its associated systems through periodic inspection, testing, servicing, and emergency support over a period of one year after one year dlp duration one 1 years from the date of completion of dlp. services included scheduled quarterly site visits, visual inspection for overheating, corrosion, physical damage, cleaning of preventive maintenance panels dust, debris, moisture control, tightening of connections and torque testing of terminals, megger testing of insulation resistance, functional test of breakers and rcds corrective maintenance fault finding and diagnosis for reported issues, replacement of defective components, repair of wiring or damaged insulation, troubleshooting tripping or overloads emergency support on-site visit within 48 hours of call define sla clearly documentation and reporting maintenance logs and service reports after each visit annual performance summary report


Agency / Dept : indian army
Tender Value : 0
Due Date : May 18, 2026
T18 Ref No : 15287541
Location : sakltlake , west bengal
Source : GEM Tenders

tender for title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13, supply installation testing and commissioning and maintenance of addressable fire alarm and detection system at uco bank, supplying, installing, testing and commissioning approved make microprocessor based multi-loop, networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability, including audible and visible feedback, backlit by a long life, solid-state lcd. it shall also include a full qwerty-style keypad on the color, touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm, supervisory alarm, trouble, etc) using the touchscreen with customizable buttons ,10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops., supplying, installing, testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864, 10th edition requirements, supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed, the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote, serially-connected display. a five inch touchscreen display provides system status, point information, and event counters. the display shows two events simultaneously, and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge, silence, reset and drill., supplying, installing, testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved., supply, installation, testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation., supplying, installing, testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved., supplying, installing, testing and commissioning approved make addressable control module for sounders / strobes / sounder cum strobes. the control module shall provide supervised nac output rated at 24v dc, 2a. the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. addressing shall be with user friendly rotary decimal switches. module shall be supplied with mounting plate from oem for ease of installation & maintenance. the device shall be ul listed & fm approved., supplying, installing, testing and commissioning approved make addressable relay module for ahu, access control, lifts, staircase pressurization, fire suppression & other third party outputs. the relay module shall provide contact rated at 24v dc, 2a. the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. addressing shall be with user friendly rotary decimal switches. module shall be supplied with mounting plate from oem for ease of installation & maintenance. the device shall be ul listed & fm approved., supplying, installing, testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement. isolator base can also be proposed, however in that case needs to be considered with each detector & module. the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. module shall be supplied with mounting plate from oem for ease of installation & maintenance. the device shall be ul listed & fm approved., supplying, installing, testing and commissioning approved make response indicator for all detectors located above false ceiling, supplying, installing, testing and commissioning of hooter cum strobe with in-built lithiumion battery with a minimum of 110cd and 93 db complete as required, ce cetrified with power supply unit., supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable, red in colour., camc for 4 years after expiry of one year warranty of addressable fire detection system


Agency / Dept : uco bank
Tender Value : 2500000
Due Date : May 22, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15379083
Location : mumbai , maharashtra
Source : GEM Tenders

corrigendum tender for main signal , shunt signal , panel servicing work , signaling cable , cable trench excavation , cable laying , main signal termination , shunt signal termination , hdpe pipe supply , pipe laying work , signal dismantling work , interlocking system overhaul, replacement of signal and interlocking system at mbpa railway yard wadala, main signal units including complete structure fittings and associated works as per standard specifications refer tender document for detailed description, shunt signal unit with all fittings wiring and accessories as per site requirements refer tender document for detailed description, overhauling and servicing of control panel including cleaning of relay base contacts racks and necessary maintenance work refer tender document for detailed description, 6 core 1 point 5 sq mm armoured copper signaling cable conforming to irs s 63 2014 specifications refer tender document for detailed description, excavation of trenches along track as per route plan including refilling after cable laying in specified soil conditions refer tender document for detailed description, laying of signaling telecom cables in trenches with proper depth route clearance and soil covering refer tender document for detailed description, termination of tail cables on main signals including wiring fixing lenses and required materials refer tender document for detailed description, termination of tail cables on shunt signals including wiring lenses fixing and associated work refer tender document for detailed description, supply of dwc hdpe pipes with couplers and o rings fire resistant and anti rodent as per rdso specifications refer tender document for detailed description, laying of dwc rcc pipes in trenches at track crossings roads and platforms including necessary fittings refer tender document for detailed description, dismantling existing signal posts and equipment and transporting them to designated scrap locations refer tender document for detailed description, repairing and overhauling of mechanical interlocking system including rollers brackets locking system lubrication balancing testing and commissioning refer tender document for detailed description


Agency / Dept : mumbai port trust MPT
Tender Value : 1399700
Due Date : May 22, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15412289
Location : dehradun , uttarakhand
Source : GEM Tenders

tender for title1 , title2 , title3 , title4 , title5 , title6, supply installation testing and commissioning of self regulating heating tape cable, providing self regulating heat tape resistance heating cable suitable for freeze protection of pipelines and utilities having rated output of thirtyfive w per meter at two hundred twenty v ac supply the heating cable shall automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable shall be suitable for continuous operation in outdoor conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems, providing mtwenty threepin connector suitable for making secure electrical joints between self-regulating heat cable terminals designed for reliable power and signal continuity the connector shall be rated for operation at two hundred twenty v ac supply and compatible with heating cables of specified capacity it shall ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be constructed from high quality weather resistant materials suitable for continuous outdoor operation under varying environmental conditions it shall provide ease of installation with a compact and durable design for use at pipeline joints terminations and interconnections the mtwenty connector shall be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress, providing temperature differential controller with auto and manual operation housed in a robust ip sixty five rated enclosure suitable for controlling heat tracing systems to prevent freezing of pipelines and utilities the controller shall be designed to automatically switch the heat tape on oblique off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller shall include in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions, providing pt hundred temperature sensors with ten metres cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors shall be of platinum resistance type pt hundred ensuring high precision stability and repeatability over a wide temperature range.each sensor shall be supplied with a ten metre long high quality insulated cable suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable, flexible, and suitable for installation in outdoor and industrial environments, providing heat tape laying and installation services for self-regulating heat tracing systems including proper routing and fixing of heating cables along pipelines joints valves and exposed sections near utility areas the installation shall be carried out to ensure uniform heat distribution and effective freeze protection as per recommended practices, providing three core one point five sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications and rated for voltage grade up to eleven hundred volts the cable shall conform to the requirements of is six nine four and two thousand ten the conductors shall be made of high conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it shall be suitable for continuous operation in indoor and outdoor environments offering reliable performance electrical safety and long service life


Tender Value : 0
Due Date : Jun 08, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Signaling Cable Laying. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Signaling Cable Laying sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Signaling Cable Laying Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Signaling Cable Laying, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Signaling Cable Laying Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Signaling Cable Laying Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Signaling Cable Laying.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Signaling Cable Laying depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Signaling Cable Laying Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Signaling Cable Laying bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Signaling Cable Laying. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Signaling Cable Laying, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Signaling Cable Laying, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Signaling Cable Laying?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Signaling Cable Laying tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Signaling Cable Laying?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Signaling Cable Laying, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Signaling Cable Laying is declared L1 and is generally awarded the contract