Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

75Results forLatest Removing leakage Tenders List

Latest Removing leakage Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Removing leakage tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Removing leakage tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Removing leakage Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Removing leakage tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Removing leakage Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Removing leakage Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Removing leakage Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Removing leakage tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Removing leakage Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Removing leakage sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Removing leakage tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Removing leakage tenders.

Is EMD mandatory for all Removing leakage tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Removing leakage work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Removing leakage tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Removing leakage Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16264554
new Tender
Location : churu , rajasthan
new Tender

Agency / Dept : municipal corporation
Tender Value : 500000
Due Date : Jul 23, 2026
T18 Ref No : 16264555
new Tender
Location : churu , rajasthan
new Tender

Agency / Dept : municipal corporation
Tender Value : 500000
Due Date : Jul 23, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16174784
live Tender
Location : jammu , jammu & kashmir
Source : GEM Tenders
live Tender

corrigendum tender for rewind of submersible motor 7.5 hp , sub cable 4 sqmm 3 core complete. , gm bearing bush , water seal , cable seal , revolving disc , sand guard , dol bush , dol sleave , ss distance sleeve , rottar sleeve turning and grinding , coupling key , impellar key , t nut , guide bush , gm neck ring , nut bolts with washer , rubber packing flange of size 150 mm , cable jointing kit , painting of submersible pump set , ms column pipe 100 mm dia medium grade , labour charges for taking out and relowering , labour charges for opening cutting rewinding , supply installation testing and commissioning , material and labour for making , attending day to day emergency breakdowns , attending day to day emergency breakdowns complaints of damaged , material and labour pcc 1 , supply and fixing rotational moulded , material and labour for disconnecting , supply only anti friction heavy duty , material and labour for removing swt column pipes , material and labour for earthing , supply laying 50 mm bore steel water , supply and fixing in replacement , excavation in trenches not , returning filling in including spreading leveling , removing excavated soil to a distance, repair and replacement to submersible pump set, rewind of submersible motor 7.5 hp, sub cable 4 sqmm 3 core complete., gm bearing bush, water seal, cable seal, revolving disc, sand guard, dol bush, dol sleave, ss distance sleeve, rottar sleeve turning and grinding, coupling key, impellar key, t nut, guide bush, gm neck ring, nut bolts with washer 1 by 2 x 2 inch, rubber packing flange of size 150 mm, cable jointing kit, painting of submersible pump set, ms column pipe 100 mm dia medium grade of 3 mtr in length, labour charges for taking out and relowering the sub pump set from bore well, labour charges for opening cutting rewinding cleaning complete the sub pump for repairing and refixing the same after repairing, assembling testing complete, supply installation testing and commissioning in repairs of sathya sai dosing drum adjustable dozing pump including fixing complete, material and labour for making 100 percentage serviceable to the amf lt panel startor suitable for motors and submersible pump by tracing out defects and replacing unsv parts including control wiring complete. minor parts such as nuts, bolts, washers, thimbles etc shall be deemed to be included in the quoted rate., attending day to day emergency breakdowns complaints of damaged water supply lines of 15 to 25mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply., attending day to day emergency breakdowns complaints of damaged water supply lines of 40mm to 50mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply, attending day to day emergency breakdowns complaints of damaged water supply lines of 80mm to 150mm bore in distribution system and restoration of water supply by stopping the leakage occured by deputing skilled semi skilled man power for smooth functioning of water supply, material and labour pcc 1 ration 3 ratio 6 type c1 using 20 mm graded stone aggregate for platform of motor and water storage tank size 1.5 x 1.5 x 0.4m etc incl fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete., supply and fixing rotational moulded polyethylene water storage tank inner and out white five layers isi marked cylinderical vertical with closed top hoisted with threaded cap and fixed of capacity 2000 liters each including all accessories including taking down of old broken water tank complete., material and labour for disconnecting and removing the squirrel cage 3 phase 415 volts 50 hz induction motor of 7.5 hp capacity from its foundations by disconnecting electrical connections and motor couplers taking it to workshop for repair and dismantling and opening up of motor removing burnt out winding wires complete cleaning startor and rotor assembly, supply only anti friction heavy duty bearings suitable for 7.5 hp., material and labour for removing swt column pipes upto 100 mm dia with submersible flat cable of any type and dismantling and taking up down submersible pump and motor assembly of capacity 7.5 hp shifting to workshop and removing unserviceable spares replacing with new spares such impeller bushes distance bush seal etc of same specifications type model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets assembling back and testing for proper function including necessary machining works as required bringing back and reinstalling into the swt complete., material and labour for earthing in repalcement complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to and including 25 x 4 mm galvanised earth strip by means of bolts nuts check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical, supply laying 50 mm bore steel water tubing medium grade galvanised with all fittings including short lengths laid in trenches complete with all fittings such as bends elbows tee short pieces connectors back nuts diminishing pieces caps and plugs unions etc including taking down old unsv pipe any type complete, supply and fixing in replacement direct on line starter in sheet metal enclosure for motor rating 415 volts 3 phase 50 hz 9-14 amps relay maximum range of capacity 7.5 hp complete, excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts wells cesspits manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft loose soil complete, returning filling in including spreading leveling watering and well ramming in layer not exceeding 25 cms thick after laying and testing of cable complete, removing excavated soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete


Agency / Dept : indian army
Tender Value : 0
Due Date : Jul 21, 2026
T18 Ref No : 16174786
live Tender
Location : jammu , jammu & kashmir
Source : GEM Tenders
live Tender

corrigendum tender for taking down carefully copper aluminium point , material and labour for point wiring for light fan , material and labour complete for switch , material and labour complete for socket , material and labour complete for socket outlet , material and labour complete for switch socket , supply and fixing in replacement , supply and fixing switch modular , supply and fixing led tube light , supply and fixing led tube light fitting , supply and fixing 12 watts led bulb , supply and fixing in replacement of lam , supply and fixing of powder coated pressure , supply and fixing in replacement mccb , supply and fixing amp rating , supply and fixing amp rating 240v 10ka , supply and fixing exhaust fan steel body , supply and fixing mccb 4 pole , material and labour for comprehensive maintenece , replacement of old unseviceable damage , repalcement of old unsv damage pcb with new , material and labour for detecting the gas leakage , supply and fixing copper pipe , repair rewinding and maint of voltage stabilizer , earthing complete with copper earth plate, repair and maint of internal electric wiring and repair to air conditioning system, taking down carefully copper aluminium point wiring light fan bell socket or power complete including fixture and fittings such as switches ceiling roses pendents regulators sockets light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls floors etc . credit for above items should be made as per conditions separately., material and labour for point wiring for light fan bell with frls cable 1.5 sqmm pvc insulated red for phase and black for neutral unsheathed multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick pvc casing caping concealed with pvc conduit as per site requirment with all accessories and 1.50 sqmm green in colour pvc copper conductor cable for earth continuity connected to common earth dolly incl pvc box surface modular sunken box type with pvc sheet for mounting fittings such as switches sockets fan regulators etc complete all as specified and directed for one light/fan bell point controlled by one switch and making good to disturbed surface of wall etc, material and labour complete for switch piano flush button single pole one way 16 amp 240 volts., material and labour complete for socket outlet 2 in 1 2 and 3 pin 6 amp piano flush type 240 volts complete all as specified, material and labour complete for socket outlet 2 in 1 3 pin 6 amp and 16 amp piano flush type 240 volts complete all as specified, material and labour complete for switch socket combination 5a 16 a 5 in 1 flush type 240 volts complete all as specified, supply and fixing in replacement 36 watts recess pendant mounting ultraslim led flat panel 2 x 2 made of extruded aluminium frame with high leds and glare free opal diffuser ip20 incl taking down old unsv., supply and fixing switch modular piano flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed., supply and fixing led tube light fitting 1x18 20 watt wall mounted led batten with aluminum housing and integrated electronic driver incl taking down old unsv., supply and fixing led tube light fitting 1x10 watt wall mounted led batten with aluminum housing and integrated electronic driver incl taking down old unsv., supply and fixing 12 watts led bulb complete all as specified and directed., supply and fixing in replacement of lamp holder angle holder insulated body with black white plate for batten fittings including taking down unsv lamp holder complete all as specified and directed., supply and fixing of powder coated pressure die cast aluminium compact high power led street light fittings with heat resistant toughned glass with lense and top opening having 60 watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box fixed in repairs complete all as specified and as directed., supply and fixing in replacement mccb having current ratings 63 amps with rupturing cap 16 ka ac 415 volts three pole all as specified and directed including dismentling the existing u s mccbs with all connections and all as required at site or directed., supply and fixing amp rating 240v 10ka c curve spn miniature circuit breaker mcb and 32 amp current carrying capacity complete with connection testing and commissioning including taking down old unsv mcb complete., supply and fixing amp rating 240v 10ka c curve sp miniature circuit breaker mcb and 6 to 32 amp current carrying capacity complete with connection testing and commissioning including taking down old unsv mcb complete., supply and fixing exhaust fan steel body ac single phase. 230v of size 300mm sweep heavy duty with blades frame and louvers including making hole and suitable fixing avoid bird entred from outside complete all as specified and directed, supply and fixing mccb 4 pole 415 volts adjustable type 200 amps with breaking capacity 36 ka including old taking dwon and refixing with new complete all as specified directed., material and labour for comprehensive maintenece and servicing of split type air conditioner/window type unit of any capacity upto 2 ton outer and inner unit both of any make including cleaning the dust from body with blower cleaning of condenser and cooling coil checking all connections including functioning of metal clad socket dp switch function of relay capacitors overload protector thermostat fan motor fan blower drum electronic contol box, etc,, replacement of old unseviceable damage hermatic sealed compressor unit with new hermatic sealed unit 2 ton capacity and any specifications including taking down unsv hermatic sealed unit complete all as specified and directed., repalcement of old unsv damage pcb with new pcb for split air conditioner of capacity 2 ton and any type any specification including taking down old unsv pcb complete all as specified and directed., material and labour for detecting the gas leakage rectifying the defects including repair to condensor coil/evaporator coil by means of welding soldring etc vacumizing and charging topping up fresh freon gas and commissioning and testing for split type window type ac all as specified and directed, supply and fixing copper pipe 1 4 and also removing old unsv copper pipe from existing split acs any type any make complete all as specified and direceted., repair rewinding and maint of voltage stabilizer of any make and capacity up to 5 kva after disconnecting the voltage stabilizer from machine rewinding with super enamalled copper of existing gauge including replacement of unsv part like voltmetre amp metre cut out relay electric circuit indicator lamp top plug flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface complete all as specified and directed., earthing complete with copper earth plate electrode 60x60cmx3.15mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level connected to copper strip 20x3mm as earthing lead by means of bolts nuts check nuts and washers of copper brazing all as shown in electrical plate no. 3 connected to earthing test point including pcc earth pit with galavanised pit cover all as specified or indicated including testing on completion


Agency / Dept : indian army
Tender Value : 0
Due Date : Jul 21, 2026
T18 Ref No : 16239961
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for providing and fixing of 5 or 6 amps piano switch , providing and fixing of 15 or 16 amps piano switch , providing and fixing of 3 pin 5 or 6 amps piano socket , providing and fixing of 6 pin 15 or 16 amps piano socket , providing and fixing of 100watt step type electronic fan regulator , providing and fixing of call bell or buzzer , providing and fixing of 2.5mfd capacitor , providing and fixing of 36watt fl. tube light , providing and fixing of 20w aluminium led batten tubelight , repairing of ceiling fan upto 1400mm sweep , repairing of wall fan upto 450mm sweep , repairing of exhaust fan upto 450mm sweep , providing and fixing of 1400mm sweep, copper wound ceiling fan , replacement of faulty street light with new 45w high performance led street light , providing and fixing of 50mm dia heavy duty gun metal gate valve , painting of 16nos. compound light pole, 3nos. water pumps , providing and fixing of response indicator , providing and fixing of hammer and chain , rectification of fault in existing fd and fa system , replacement of hose pipe alongwith horn , providing and fixing of 0 to 100a range 96 sq.mm size ac ammeter , providing and fixing of 0 to 12kv range 96 sq.mm size ac voltmeter , providing and fixing of red or yellow or blue colour led indicating lamp , providing and fixing of ct pt operated 3 phase 3 wire or 4 wire ht trivector meter , providing and fixing of ammeter selecter switch , providing and fixing of 11kv ht potential transformer of 11kv by 110v ratio , servicing of 11kv, 400amp oil circuit breaker , providing and fixing of 11kv ht current transformer of 100 by 50 by 5 ratio , attending oil leakage of 500kva transformer , servicing and repairing of 800a to 1250a acb , providing and fixing of red or yellow or green colour led indicating lamp , providing and fixing of blue colour led indicating lamp , providing and fixing of 0 to 600v range ac voltmeter of 96 sq.mm size , providing and fixing of 6a vss with control wiring etc. , providing and fixing of under voltage coil suitable for 800a or 1250a acb , providing and fixing of shunt release coil suitable for 800a or 1250a acb , providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link , providing and fixing of 25kvar md xl type 440v capacitor , providing and fixing of 5kvar md xl type 440v capacitor , providing and fixing of 10kvar md xl type 440v capacitor , repairing of apfc relay of 100kvar capacitor panel , repairing of electrical and mechanical interlocking , providing and fixing of digital rpm cum hour meter , providing and fixing of 24v, 10a smps battery charger , providing and fixing of 0 to 600a range ac ammeter of 96 sq.mm size , providing and fixing of emmergency stop switch , attending diesel leakage from 380kva ea set , repairing of existing faulty control circuit card of 380 kva dg set , providing and fixing of 80 to 100 mfd starting capacitor , providing and fixing of 36 to 50 mfd running capacitor , providing and fixing of 4 to 6 mfd capacitor , providing and fixing of contactor relay , providing and fixing of starting relay , providing and fixing of thermostat , providing and fixing of selector switch in window ac , providing and fixing of remote for 1.5tr or 2tr split ac , supplying and charging of r 22 refrigerant gas, ocm of ems at bajirao rd pune sh attending defects in scope of satyam enterprises at risk and cost, providing and fixing of 5 or 6 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 15 or 16 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 3 pin 5 or 6 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 6 pin 15 or 16 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 100watt step type electronic fan regulator on existing switchboard complete etc. as reqd., providing and fixing of call bell or buzzer suitable for 230v, 1phase ac supply complete etc. as reqd., providing and fixing of 2.5mfd capacitor in existing fan complete etc. as reqd., providing and fixing of 36watt fluorescent tube light complete etc. as reqd., providing and fixing of 20w aluminium led batten tubelight with aluminium heat sink, 6500k cool day light, 2000 lumen for commercial use including testing commissioning etc complete as reqd, repairing of ceiling fan upto 1400mm sweep including removing, servicing, rewinding, varnishing, replacement of bearing, to and fro transportation, reinstallation testing etc complete as reqd., repairing of wall fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, repairing of exhaust fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 1400mm sweep, 80watt, 280 to 370rpm, copper wound ceiling fan incl. 3nos. blade, 30cm long down rod, 2no. canopies etc. suitable for 230v, 1ph ac supply etc. complete as reqd, replacement of faulty street light with new 45w high performance led street light having ip66 protection street optic lens including 1.5sqmm copper wiring from pole box to fitting etc complete as reqd, providing and fixing of 50mm dia heavy duty gun metal gate valve in discharge water line of pump set etc complete as required., painting of 16nos. compound light pole, 2nos. 5hp, 1no. 3hp capacity water pumps incl. surface cleaning and applying one or more coats of approved shade synthetic enamel paint complete etc. as reqd., providing and fixing of response indicator with metallic cover, 2nos. leds on existing surface or recess ms box including connection testing commissioning etc complete as required., providing and fixing of hammer and chain on existing surface or recess manual call point box etc complete as required., rectification of fault in existing fd and fa system incl. checking of control wiring, repairing of control cards in mcp or lcp, hooters, detectors, ri, pill box, pa system etc complete as required., replacement of hose pipe alongwith horn of 4.5kg co2 type fire extinguisher etc complete as required., providing and fixing of 0 to 100a range 144 sq.mm size suitable for ct ratio 100 by 50 by 5 ac ammeter in 11kv ht panel etc. complete as reqd., providing and fixing of 0 to 12kv range 144 sq.mm size suitable for pt ratio 11kv by 110v ac voltmeter in 11kv ht panel etc. complete as reqd., providing and fixing of red or yellow or blue colour led indicating lamp suitable for 110v ac supply in 11kv ht panel including connection, testing, commissioning etc. as reqd., providing and fixing of ct pt operated 3 phase 3 wire or 4 wire ht trivector meter in 11kv ht panel etc. complete as reqd., providing and fixing of ammeter selecter switch with control wiring in 11kv ht panel etc. complete as reqd., providing and fixing of 11kv ht potential transformer of 11kv by 110v ratio in 11kv ht panel etc. complete as reqd., servicing of 11kv, 400amp oil circuit breaker incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of 11kv ht current transformer of 100 by 50 by 5 ratio in 11kv ht panel etc. complete as reqd., attending oil leakage through ht and lt bushing, oil tank of 500kva transformer, side glass incl. replacement of gasket etc complete as reqd, servicing and repairing of 800a to 1250a acb incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of red or yellow or green colour led indicating lamp for mv panel including connection, testing, commissioning etc. as reqd., providing and fixing of blue colour led indicating lamp for mv panel including connection, testing, commissioning etc. as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in mv panel including connection testing commissioning complete etc. as reqd., providing and fixing of 3 pole and off 6a, voltmeter selector switch with control wiring in mv panel etc. complete as reqd., providing and fixing of under voltage coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of shunt release coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 25kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 5kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 10kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., repairing of apfc relay of 100kvar capacitor panel including calibration, testing on load and auto mode operation, testing, commissioning etc. as reqd., repairing of electrical and mechanical interlocking between 4nos. incomers and 1no. bus coupler including replacing mechanical locks, wiring, connection, testing, commissioning etc. as reqd., providing and fixing of digital rpm cum hour meter suitable for existing 380kva ea set including connection testing commissioning etc. complete as reqd., providing and fixing of 24v, 10a smps battery charger in existing existing 380kva ea set control panel including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in 380kva ea set control panel including connection testing commissioning complete etc. as reqd., providing and fixing of emmergency stop switch on 380kva ea set including connection testing commissioning complete etc. as reqd., attending diesel leakage in fuel tank, fuel valves, fuel hoses etc. of 380kva ea set with suitable means complete etc. as reqd., repairing of existing faulty control circuit card of volvo penta make tad1230d model 380 kva dg set including to and fro transportation and reinstallation, testing on load etc. complete as reqd., providing and fixing of 80 to 100 mfd starting capacitor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 36 to 50 mfd running capacitor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 4 to 6 mfd capacitor for condenser fan motor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of contactor relay in outdoor unit of split ac including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of starting relay in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of thermostat in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of selector switch in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of remote for 1.5tr or 2tr split ac unit including testing etc. complete as reqd., supplying and charging of r 22 refrigerant gas in existing window or split ac unit refrigerant circuit etc complete as required.


Tender Value : 0
Due Date : Aug 04, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16239963
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for providing and fixing of 5 or 6 amps piano switch , providing and fixing of 15 or 16 amps piano switch , providing and fixing of 3 pin 5 or 6 amps piano socket , providing and fixing of 6 pin 15 or 16 amps piano socket , providing and fixing of 100watt step type electronic fan regulator , providing and fixing of call bell or buzzer , providing and fixing of 2.5mfd capacitor , providing and fixing of 36watt fl. tube light , providing and fixing of 20w aluminium led batten tubelight , repairing of ceiling fan upto 1400mm sweep , repairing of wall fan upto 450mm sweep , repairing of exhaust fan upto 450mm sweep , providing and fixing of 1400mm sweep, copper wound ceiling fan , repairing of faulty compound light fitting , providing and fixing of 40mm dia heavy duty isi marked brass foot valve , providing and fixing of 50mm dia heavy duty isi marked brass foot valve , providing and fixing of 40mm dia heavy duty upvc pipe , providing and fixing of 50mm dia heavy duty upvc pipe , painting of 16nos. compound light pole, 7nos. water pumps , repairing of 3hp centrifugal water pump , providing and fixing of 12v, 7ah smf battery , providing and fixing of response indicator , providing and fixing of hammer and chain , rectification of fault in existing fd and fa system , replacement of hose pipe alongwith horn , refilling of existing 4.5kg, co2 type fire extinguisher , providing and fixing of space heater , providing and fixing of red or yellow or green colour led indicating lamp , servicing of 11kv, 400amp oil circuit breaker , attending oil leakage of 500kva transformer , servicing and repairing of 800a to 1250a acb , providing and fixing of blue colour led indicating lamp , providing and fixing of 0 to 600v range ac voltmeter of 96 sq.mm size , providing and fixing of 6a vss with control wiring etc. , providing and fixing of operating handle suitable for 1250a acb , providing and fixing of under voltage coil suitable for 800a or 1250a acb , providing and fixing of shunt release coil suitable for 800a or 1250a acb , providing and fixing of 32a, 4way tpn connector , providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link , providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link , providing and fixing of 25kvar md xl type 440v capacitor , providing and fixing of 5kvar md xl type 440v capacitor , providing and fixing of 10kvar md xl type 440v capacitor , repairing of apfc relay of 100kvar capacitor panel , repairing of electrical and mechanical interlocking , providing and fixing of hp cutout , providing and fixing of lp cutout , providing and fixing of hp gauge , providing and fixing of lp gauge , providing and fixing of thermostat , providing and fixing of condenser fan blade , providing and fixing of blower bearing , providing and fixing of mpr d2 overload relay , providing and fixing of 230v a.c. hooter , carrying out nitrogen pressure testing , supplying and charging of r 22 refrigerant gas , providing and fixing of 0.5 hp, 230v a.c. condenser fan motor , providing and fixing of v belt suitable for charging alternator , providing and fixing of 24v dc hooter for dg set panel , attending engine oil leakage, ocm of ems at model colony pune sh attending defects in scope of satyam enterprises at risk and cost, providing and fixing of 5 or 6 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 15 or 16 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 3 pin 5 or 6 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 6 pin 15 or 16 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 100watt step type electronic fan regulator on existing switchboard complete etc. as reqd., providing and fixing of call bell or buzzer suitable for 230v, 1phase ac supply complete etc. as reqd., providing and fixing of 2.5mfd capacitor in existing fan complete etc. as reqd., providing and fixing of 36watt fluorescent tube light complete etc. as reqd., providing and fixing of 20w aluminium led batten tubelight with aluminium heat sink, 6500k cool day light, 2000 lumen for commercial use including testing commissioning etc complete as reqd, repairing of ceiling fan upto 1400mm sweep including removing, servicing, rewinding, varnishing, replacement of bearing, to and fro transportation, reinstallation testing etc complete as reqd., repairing of wall fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, repairing of exhaust fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 1400mm sweep, 80watt, 280 to 370rpm, copper wound ceiling fan incl. 3nos. blade, 30cm long down rod, 2no. canopies etc. suitable for 230v, 1ph ac supply etc. complete as reqd, repairing of faulty compound light fitting incl. supplying and fixing high performance cool daylight 40watts led bulb, alongwith 1.5sqmm copper wiring from pole box to fitting etc complete as reqd, providing and fixing of 40mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 50mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 40mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, providing and fixing of 50mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, painting of 16nos. compound light pole, 7nos. 1hp to 10hp capacity water pumps incl. surface cleaning and applying one or more coats of approved shade synthetic enamel paint complete etc. as reqd., repairing of 3hp centrifugal water pump incl. rewinding, varnishing, greasing, replacement of bearings, nutbolts, gland packing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 12v, 7ah semi maintenance free battery in the existing fire detection panel including connection testing commissioning etc complete as required., providing and fixing of response indicator with metallic cover, 2nos. leds on existing surface or recess ms box including connection testing commissioning etc complete as required., providing and fixing of hammer and chain on existing surface or recess manual call point box etc complete as required., rectification of fault in existing fd and fa system incl. checking of control wiring, repairing of control cards in mcp or lcp, hooters, detectors, ri, pill box, pa system etc complete as required., replacement of hose pipe alongwith horn of 4.5kg co2 type fire extinguisher etc complete as required., refilling of existing 4.5kg, co2 type fire extinguisher including transportation to and fro, hydrualic pressure, testing, cleaning, labling etc. complete as required., providing and fixing of space heater for 11kv ht panel inclding connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp suitable for 110v ac supply in 11kv ht panel including connection, testing, commissioning etc. as reqd., servicing of 11kv, 400amp oil circuit breaker incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, attending oil leakage through tap changer, oil tank of 500kva transformer incl. replacement of gasket, cleaning of oil level guage side glass and fixing of marshalling box cover etc complete as reqd, servicing and repairing of 800a to 1250a acb incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of blue colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in lt panel including connection testing commissioning complete etc. as reqd., providing and fixing of 3 pole and off 6a, voltmeter selector switch with control wiring in lt panel etc. complete as reqd., providing and fixing of operating handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of drawout handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of under voltage coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of shunt release coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of 32a, 4way tpn connector in lt panel with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 25kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 5kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 10kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., repairing of apfc relay of 100kvar capacitor panel including calibration, testing on load and auto mode operation, testing, commissioning etc. as reqd., repairing of electrical and mechanical interlocking between 4nos. incomers and 1no. bus coupler including replacing mechanical locks, wiring, connection, testing, commissioning etc. as reqd., providing and fixing of hp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of hp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of thermostat in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of condenser fan blade in condenser of 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of blower bearing in 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of mpr d2 overload relay in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of 230v a.c. hooter in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., carrying out nitrogen pressure testing and attending leackage of 7tr package ac refrigerant circuit incl. leak testing, flaring, brazing, flushing, vacuumising, purging etc. complete as reqd., supplying and charging of r 22 refrigerant gas in existing 7tr conventional package ac refrigerant circuit etc complete as required., providing and fixing of 0.5 hp, 230v a.c. condenser fan motor suitable for fixing in condenser of sidwal or singhsons make 7tr or 10tr ac pkg unit incl. connection testing comm. etc complete as reqd., providing and fixing of v belt suitable for charging alternator of 500kva cummins make vt 1710g model ea set etc complete as reqd., providing and fixing of 24v dc hooter for dg set panel including connection testing commissioning etc. complete as reqd., attending engine oil leakage at top head and rocker cover, fuel pump etc. incl. replacement of tappet gasket, rubber o rings, mounting washer, high temp. rtv silicone sealant, fuel hoses etc. as reqd.


Tender Value : 0
Due Date : Aug 04, 2026
T18 Ref No : 16247630
live Tender
Location : bangalore , karnataka
live Tender

Tender Value : 0
Due Date : Jul 27, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Removing Leakage. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Removing Leakage sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Removing Leakage Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Removing Leakage, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Removing Leakage Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Removing Leakage Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Removing Leakage.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Removing Leakage depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Removing Leakage Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Removing Leakage bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Removing Leakage. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Removing Leakage, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Removing Leakage, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Removing Leakage?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Removing Leakage tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Removing Leakage?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Removing Leakage, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Removing Leakage is declared L1 and is generally awarded the contract