Search Tenders
Filters
Reset All
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

20Latest Pre cooling transformer Tenders List

Latest Pre cooling transformer Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Pre cooling transformer tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Pre cooling transformer tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Pre cooling transformer Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Pre cooling transformer tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Pre cooling transformer Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Pre cooling transformer Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Pre cooling transformer Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Pre cooling transformer tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Pre cooling transformer Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Pre cooling transformer sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Pre cooling transformer tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Pre cooling transformer tenders.

Is EMD mandatory for all Pre cooling transformer tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Pre cooling transformer work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Pre cooling transformer tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Pre cooling transformer Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16517818
Location : imphal , manipur
Source : GEM Tenders
NEW TENDER
corrigendum tender for refer soq, sh-i, item no. 1a - supply of bi-directional elevated high intensity led runway edge light fixture. a. clear and yellow , refer soq, sh-i, item no. 1- supply of bi- directional elevated high intensity led runway edge light fixure. b. clear and clear , refer soq, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting. , refer soq, sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting , refer soq, sh-i, item no. 4a. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. a.clear and yellow , refer soq, sh-i, item no. 4b. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. b. clear and clear , refer soq, sh-i, item no. 5a. supply of following rating 5000v, 50hz series isolating transformers. a. 45 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers. b. 100 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator. a. 7.5kw , refer soq, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator. b. 2.5 kw , refer soq, sh-i, item no. 7a. supply of following 5kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. a. 6 sq.mm , refer soq, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. b. 2c x 6 sq.mm , refer soq, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle. a. 6 sq.mm , refer soq, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63. a. 40mm dia , refer soq, sh-ii, item no. 1. itc of ccr including interconnection of existing power cable and control cable within 50m lead , refer soq, sh-ii, item no. 2a. itc of fitting type on the existing transformer housing boxes. a. hirl elevated type , refer soq, sh-ii, item no. 2b. itc of fitting type on the existing transformer housing boxes. b. sapl , refer soq, sh-ii, item no. 2c. itc of fitting type on the existing transformer housing boxes. c. threshold , refer soq, sh-ii, item no. 2d. itc of fitting type on the existing transformer housing boxes. d. end light , refer soq, sh-ii, item no. 2e. itc of fitting type on the existing transformer housing boxes. e. inset , refer soq, sh-ii, item no. 3. itc of airfield lighting cable. , refer soq, sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable. a. 6 sq.mm , refer soq, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade , refer soq, sh-ii, item no. 6. laying, jointing and coomissioning of 40 mm dia hdpe pipe. , refer soq, sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate including transportation to aai store. , refer soq, sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc. including transportation to aai store., supply installation testing and commissioning of led rwy elevated edgelight and cat i and sapl and inset fitting and iso transformer and ccr, sh-i item no. 1a. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. a. clear and yellow, sh-i, item no. 1b. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. b. clear and clear, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6a current, colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 4a. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. a. clear and yellow, sh-i, item no. 4b. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. b. clear and clear, sh-i, item no. 5a. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. a. 45 watt, 6.6a by 6.6a, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. b. 100 watt, 6.6a by 6.6a, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. a. 7.5 kw, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. b. 2.5 kw, sh-i, item no. 7a. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. a. 6 sq.mm, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. b. 2c x 6 sq.mm, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle of type i, class b primary connector kit with field attachment and suitable for 5 kv grade single core copper conductor, copper braided, xlpe insulated pe outer sheathed shielded cable, complete as required as per technical specifications. a. 6 sq.mm, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63 confirming to is 4984 2016 with latest amendment, complete with all associated accessories like couplers, bends, tee etc. complete as per site requirement as per technical specifications. a. 40 mm dia, sh-ii, item no. 1. installation testing and commissioning of ccr including interconnection of existing power cable and control cable within 50m lead and making foundation, for operating with the existing airfield lighting control and monitoring system alcms complete as required as per technical specifications., sh-ii, item no. 2a. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. a. hirl elevated type, sh-ii, item no. 2b. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. b. sapl, sh-ii, item no. 2c. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. c. threshold, sh-ii, item no. 2d. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. d. end light, sh-ii, item no. 2e. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. e. end light, sh-ii, item no. 3. installation, testing and commissioning of the undermentioned airfield lighting fixtures complete with base plate, transformer, support, interconnection, end termination earthing including ensuring original elevation of the fitting x-y-z of the fitting through checking or of measurement of the level or alignment with dgps and total station etc. as required., sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable including filling the gap with water sealent material, applying pvc insulation tape of bell or permacel etc. complete as required. a. 6 sq.mm, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade upto cable of size upto 25 sq.mm in existing pipe etc. as reqd., sh-ii, item no. 6. laying, jointing and commissioning of 40 mm dia hdpe pipe pn6 grade pe 63 confirming to is 4984-2016 by trenchless method by carrying out horizontal directional drilling hdd along or across various fexible or rigid pavement like runway or taxiway and service road or drain etc. at various site or location as per the drawing approved by aai including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct of various size as per the design invert level and providing baricades and necessary warning signal lights, restoration of paved surfaces or utilities etc. as required. 40 mm., sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required., sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required including measurment of the existing level of each fitting with calibrated dgps and total station by a certified survery etc, as required before dismentalling. including transportation to aai store as required.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16343707
Location : imphal , manipur
Source : GEM Tenders
LIVE TENDER
tender for refer soq, sh-i, item no. 1a - supply of bi-directional elevated high intensity led runway edge light fixture. a. clear and yellow , refer soq, sh-i, item no. 1- supply of bi- directional elevated high intensity led runway edge light fixure. b. clear and clear , refer soq, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting. , refer soq, sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting , refer soq, sh-i, item no. 4a. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. a.clear and yellow , refer soq, sh-i, item no. 4b. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. b. clear and clear , refer soq, sh-i, item no. 5a. supply of following rating 5000v, 50hz series isolating transformers. a. 45 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers. b. 100 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator. a. 7.5kw , refer soq, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator. b. 2.5 kw , refer soq, sh-i, item no. 7a. supply of following 5kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. a. 6 sq.mm , refer soq, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. b. 2c x 6 sq.mm , refer soq, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle. a. 6 sq.mm , refer soq, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63. a. 40mm dia , refer soq, sh-ii, item no. 1. itc of ccr including interconnection of existing power cable and control cable within 50m lead , refer soq, sh-ii, item no. 2a. itc of fitting type on the existing transformer housing boxes. a. hirl elevated type , refer soq, sh-ii, item no. 2b. itc of fitting type on the existing transformer housing boxes. b. sapl , refer soq, sh-ii, item no. 2c. itc of fitting type on the existing transformer housing boxes. c. threshold , refer soq, sh-ii, item no. 2d. itc of fitting type on the existing transformer housing boxes. d. end light , refer soq, sh-ii, item no. 2e. itc of fitting type on the existing transformer housing boxes. e. inset , refer soq, sh-ii, item no. 3. itc of airfield lighting cable. , refer soq, sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable. a. 6 sq.mm , refer soq, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade , refer soq, sh-ii, item no. 6. laying, jointing and coomissioning of 40 mm dia hdpe pipe. , refer soq, sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate including transportation to aai store. , refer soq, sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc. including transportation to aai store., supply installation testing and commissioning of led rwy elevated edgelight and cat i and sapl and inset fitting and iso transformer and ccr, sh-i item no. 1a. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. a. clear and yellow, sh-i, item no. 1b. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. b. clear and clear, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6a current, colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 4a. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. a. clear and yellow, sh-i, item no. 4b. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. b. clear and clear, sh-i, item no. 5a. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. a. 45 watt, 6.6a by 6.6a, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. b. 100 watt, 6.6a by 6.6a, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. a. 7.5 kw, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. b. 2.5 kw, sh-i, item no. 7a. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. a. 6 sq.mm, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. b. 2c x 6 sq.mm, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle of type i, class b primary connector kit with field attachment and suitable for 5 kv grade single core copper conductor, copper braided, xlpe insulated pe outer sheathed shielded cable, complete as required as per technical specifications. a. 6 sq.mm, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63 confirming to is 4984 2016 with latest amendment, complete with all associated accessories like couplers, bends, tee etc. complete as per site requirement as per technical specifications. a. 40 mm dia, sh-ii, item no. 1. installation testing and commissioning of ccr including interconnection of existing power cable and control cable within 50m lead and making foundation, for operating with the existing airfield lighting control and monitoring system alcms complete as required as per technical specifications., sh-ii, item no. 2a. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. a. hirl elevated type, sh-ii, item no. 2b. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. b. sapl, sh-ii, item no. 2c. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. c. threshold, sh-ii, item no. 2d. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. d. end light, sh-ii, item no. 2e. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. e. end light, sh-ii, item no. 3. installation, testing and commissioning of the undermentioned airfield lighting fixtures complete with base plate, transformer, support, interconnection, end termination earthing including ensuring original elevation of the fitting x-y-z of the fitting through checking or of measurement of the level or alignment with dgps and total station etc. as required., sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable including filling the gap with water sealent material, applying pvc insulation tape of bell or permacel etc. complete as required. a. 6 sq.mm, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade upto cable of size upto 25 sq.mm in existing pipe etc. as reqd., sh-ii, item no. 6. laying, jointing and commissioning of 40 mm dia hdpe pipe pn6 grade pe 63 confirming to is 4984-2016 by trenchless method by carrying out horizontal directional drilling hdd along or across various fexible or rigid pavement like runway or taxiway and service road or drain etc. at various site or location as per the drawing approved by aai including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct of various size as per the design invert level and providing baricades and necessary warning signal lights, restoration of paved surfaces or utilities etc. as required. 40 mm., sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required., sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required including measurment of the existing level of each fitting with calibrated dgps and total station by a certified survery etc, as required before dismentalling. including transportation to aai store as required.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15289435
Location : mumbai , maharashtra
Source : GEM Tenders
tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer
T18 Ref No : 15602515
Location : mumbai , maharashtra
Source : GEM Tenders
corrigendum tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Pre Cooling Transformer. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Pre Cooling Transformer sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Pre Cooling Transformer Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Pre Cooling Transformer, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Pre Cooling Transformer Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Pre Cooling Transformer Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Pre Cooling Transformer.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Pre Cooling Transformer depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Pre Cooling Transformer Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Pre Cooling Transformer bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Pre Cooling Transformer. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Pre Cooling Transformer, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Pre Cooling Transformer, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Pre Cooling Transformer?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Pre Cooling Transformer tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Pre Cooling Transformer?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Pre Cooling Transformer, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Pre Cooling Transformer is declared L1 and is generally awarded the contract