Latest Tender Detail from airports authority of india AAI for the tender for refer soq, sh-i, item no. 1a - supply of bi-directional elevated high intensity led runway edge light fixture. a. clear and yellow , refer soq, sh-i, item no. 1- supply of bi- directional elevated high intensity led runway edge light fixure. b. clear and clear , refer soq, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting. , refer soq, sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting , refer soq, sh-i, item no. 4a. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. a.clear and yellow , refer soq, sh-i, item no. 4b. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. b. clear and clear , refer soq, sh-i, item no. 5a. supply of following rating 5000v, 50hz series isolating transformers. a. 45 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers. b. 100 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator. a. 7.5kw , refer soq, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator. b. 2.5 kw , refer soq, sh-i, item no. 7a. supply of following 5kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. a. 6 sq.mm , refer soq, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. b. 2c x 6 sq.mm , refer soq, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle. a. 6 sq.mm , refer soq, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63. a. 40mm dia , refer soq, sh-ii, item no. 1. itc of ccr including interconnection of existing power cable and control cable within 50m lead , refer soq, sh-ii, item no. 2a. itc of fitting type on the existing transformer housing boxes. a. hirl elevated type , refer soq, sh-ii, item no. 2b. itc of fitting type on the existing transformer housing boxes. b. sapl , refer soq, sh-ii, item no. 2c. itc of fitting type on the existing transformer housing boxes. c. threshold , refer soq, sh-ii, item no. 2d. itc of fitting type on the existing transformer housing boxes. d. end light , refer soq, sh-ii, item no. 2e. itc of fitting type on the existing transformer housing boxes. e. inset , refer soq, sh-ii, item no. 3. itc of airfield lighting cable. , refer soq, sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable. a. 6 sq.mm , refer soq, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade , refer soq, sh-ii, item no. 6. laying, jointing and coomissioning of 40 mm dia hdpe pipe. , refer soq, sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate including transportation to aai store. , refer soq, sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc. including transportation to aai store., supply installation testing and commissioning of led rwy elevated edgelight and cat i and sapl and inset fitting and iso transformer and ccr, sh-i item no. 1a. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. a. clear and yellow, sh-i, item no. 1b. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. b. clear and clear, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6a current, colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 4a. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. a. clear and yellow, sh-i, item no. 4b. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. b. clear and clear, sh-i, item no. 5a. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. a. 45 watt, 6.6a by 6.6a, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. b. 100 watt, 6.6a by 6.6a, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. a. 7.5 kw, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. b. 2.5 kw, sh-i, item no. 7a. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. a. 6 sq.mm, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. b. 2c x 6 sq.mm, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle of type i, class b primary connector kit with field attachment and suitable for 5 kv grade single core copper conductor, copper braided, xlpe insulated pe outer sheathed shielded cable, complete as required as per technical specifications. a. 6 sq.mm, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63 confirming to is 4984 2016 with latest amendment, complete with all associated accessories like couplers, bends, tee etc. complete as per site requirement as per technical specifications. a. 40 mm dia, sh-ii, item no. 1. installation testing and commissioning of ccr including interconnection of existing power cable and control cable within 50m lead and making foundation, for operating with the existing airfield lighting control and monitoring system alcms complete as required as per technical specifications., sh-ii, item no. 2a. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. a. hirl elevated type, sh-ii, item no. 2b. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. b. sapl, sh-ii, item no. 2c. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. c. threshold, sh-ii, item no. 2d. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. d. end light, sh-ii, item no. 2e. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. e. end light, sh-ii, item no. 3. installation, testing and commissioning of the undermentioned airfield lighting fixtures complete with base plate, transformer, support, interconnection, end termination earthing including ensuring original elevation of the fitting x-y-z of the fitting through checking or of measurement of the level or alignment with dgps and total station etc. as required., sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable including filling the gap with water sealent material, applying pvc insulation tape of bell or permacel etc. complete as required. a. 6 sq.mm, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade upto cable of size upto 25 sq.mm in existing pipe etc. as reqd., sh-ii, item no. 6. laying, jointing and commissioning of 40 mm dia hdpe pipe pn6 grade pe 63 confirming to is 4984-2016 by trenchless method by carrying out horizontal directional drilling hdd along or across various fexible or rigid pavement like runway or taxiway and service road or drain etc. at various site or location as per the drawing approved by aai including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct of various size as per the design invert level and providing baricades and necessary warning signal lights, restoration of paved surfaces or utilities etc. as required. 40 mm., sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required., sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required including measurment of the existing level of each fitting with calibrated dgps and total station by a certified survery etc, as required before dismentalling. including transportation to aai store as required. in imphal, manipur,. Reference number 16343707. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
| T18 Ref No: | 16343707 |
|---|---|
| Tender ID: | GEM/2026/B/7816839 |
| Tender Agency: | airports authority of india AAI |
| City: | imphal |
| State: | manipur |
| Tender Related Keywords : | pvc insulated copper conductor, airfield lighting cable, copper conductor cable, isolating transformer, airfield lighting, monitoring system, copper conductor, lighting control, conductor copper, conductor cable, stainless steel, end termination, insulation tape, lighting cable, remote control, shielded cable, light fixture, light fitting, control cable, plain washers, power cable, edge light, led module, base plate, cable lead, hdpe pipe, ring seal, nut bolts, o-ring, bolts |
| Description : | total quantity = 60611 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),compliance of boq specification and supporting document |
| T18 Ref No: | 16343707 | Tender Value: | Refer Document |
|---|---|---|---|
| Tender ID: | GEM/2026/B/7816839 | Tender EMD: | Refer Document |
| Tender Agency: | airports authority of india AAI | Tender Fee: | Refer Document |
| City: | imphal | Published Date: | Jul 21, 2026 |
| State: | manipur | Due Date: | Aug 04, 2026 |
| Tender Related Keywords : | pvc insulated copper conductor, airfield lighting cable, copper conductor cable, isolating transformer, airfield lighting, monitoring system, copper conductor, lighting control, conductor copper, conductor cable, stainless steel, end termination, insulation tape, lighting cable, remote control, shielded cable, light fixture, light fitting, control cable, plain washers, power cable, edge light, led module, base plate, cable lead, hdpe pipe, ring seal, nut bolts, o-ring, bolts | Tender Opening Date: | Aug 04, 2026 |
| Description : | total quantity = 60611 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),compliance of boq specification and supporting document | ||
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.