Latest Tender Detail from bharat heavy electricals limited BHEL for the tender for e4963040 11kv cts and 6.6kv pts 01-sg4950169270-11 kv slot ct ratio- 650_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it-01. , 02-sg4950169297- 11 kv wound ct ratio-650-300_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it-02. , 03- sg4950169300-11 kv wound ct ratio- 650-300_slash_1- 1a core-i-5va 5p20 core-ii- 5va 0.5 as per ann-a it-03. , 04-sg4950169319-11 kv wound ct ratio- 300_slash_1- 1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it- 04. , 05-sg4950169327-11 kv wound ct ratio- 250_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.2 as per ann-a it-05. , 06-sg4950169335-11 kv wound ct ratio- 200_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-06. , 07-sg4950169343-11 kv wound ct ratio- 200-250_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-07. , 08-sg4950169351-11 kv wound ct ratio- 150_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-08. , 09-sg4950169360- 11 kv wound ct ratio- 60_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-09. , 10-sg4950169378- 11 kv wound ct ratio- 50_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-10. , 11-sg4950169386- 11 kv slot ct ratio- 2500_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-11. , 12-sg4950169394- 11 kv slot ct ratio- 2500_slash_1-1a core-i- cl-ps vk_greateq_520v at rct_lesseq_20 ohm im_lesseq_60ma at vk_slash_2 core-ii- cl-ps vk_greateq_520v at rct as per ann-a it-12. , 13-sg4950169408-11 kv slot ct ratio- 650_slash_1a core-i- cl-ps vk_greateq_300 rct_lesseq_4 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-13. , 14-sg4950169416-11 kv slot ct ratio- 650-300_slash_1a tapping 1- 650_slash_1a vk_greateq_300v rct_lesseq_4 ohm tapping 2- 300_slash_1a vk_greateq_250v rct as per ann-a it-14. , 15-sg4950169424-11 kv wound ct ratio- 300_slash_1a core-i- cl-ps vk_greateq_250v rct_lesseq_3 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-15. , 16- sg4950169432-11 kv wound ct ratio- 150_slash_1a core-i- cl-ps vk_greateq_200v rct_lesseq_1 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-16. , 17- sg4950169440-6.6kv 1 ph 1 pole pt ratio- 6600_slash_r3_slash_110_slash_r3_slash_110_slash_3v wdg-i-100va 0.2_slash_3p wdg-ii-50va 3p as per ann-b it-17 , 18-sg4950169459-6.6kv 1 ph 2 pole pt ratio- 6600_slash_110v wdg-i- 50va 0.5_slash_3p as per ann-b it-18, e4963040 for cts and pts for hindalco project, e4963040 11kv cts and 6.6kv pts 01-sg4950169270-11 kv slot ct ratio- 650_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it-01., 02-sg4950169297-11 kv wound ct ratio-650-300_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it-02., 03-sg4950169300-11 kv wound ct ratio- 650-300_slash_1-1a core-i-5va 5p20 core-ii- 5va 0.5 as per ann-a it-03., 04-sg4950169319-11 kv wound ct ratio- 300_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.5 as per ann-a it-04., 05-sg4950169327-11 kv wound ct ratio- 250_slash_1-1a core-i-10va 5p20 core-ii- 10va 0.2 as per ann-a it-05., 06-sg4950169335-11 kv wound ct ratio- 200_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-06., 07-sg4950169343-11 kv wound ct ratio- 200-250_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-07., 08-sg4950169351-11 kv wound ct ratio- 150_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-08., 09-sg4950169360-11 kv wound ct ratio- 60_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-09., 10-sg4950169378-11 kv wound ct ratio- 50_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.5 as per ann-a it-10., 11-sg4950169386-11 kv slot ct ratio- 2500_slash_1-1a core-i- 10va 5p20 core-ii- 10va 0.2 as per ann-a it-11., 12-sg4950169394-11 kv slot ct ratio- 2500_slash_1-1a core-i- cl-ps vk_greateq_520v at rct_lesseq_20 ohm im_lesseq_60ma at vk_slash_2 core-ii- cl-ps vk_greateq_520v at rct_lesseq_20 ohm im_lesseq_60ma at vk_slash_2 as per ann-a it-12., 13-sg4950169408-11 kv slot ct ratio- 650_slash_1a core-i- cl-ps vk_greateq_300 rct_lesseq_4 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-13., 14-sg4950169416-11 kv slot ct ratio-650-300_slash_1a tapping 1- 650_slash_1a vk_greateq_300v rct_lesseq_4 ohm tapping 2- 300_slash_1a vk_greateq_250v rct_lesseq_3 ohm im_lesseq_30ma at vk_slash_2 for both tapping as per ann-a it-14., 15-sg4950169424-11 kv wound ct ratio- 300_slash_1a core-i- cl-ps vk_greateq_250v rct_lesseq_3 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-15., 16-sg4950169432-11 kv wound ct ratio- 150_slash_1a core-i- cl-ps vk_greateq_200v rct_lesseq_1 ohm im_lesseq_30ma at vk_slash_2 as per ann-a it-16., 17-sg4950169440-6.6kv 1 ph 1 pole pt ratio- 6600_slash_r3_slash_110_slash_r3_slash_110_slash_3v wdg-i-100va 0.2_slash_3p wdg-ii-50va 3p as per ann-b it-17, 18-sg4950169459-6.6kv 1 ph 2 pole pt ratio- 6600_slash_110v wdg-i- 50va 0.5_slash_3p as per ann-b it-18 in huzur, madhya pradesh,. Reference number 16356354. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
| T18 Ref No: | 16356354 |
|---|---|
| Tender ID: | GEM/2026/B/7818145 |
| Tender Agency: | bharat heavy electricals limited BHEL |
| City: | huzur |
| State: | madhya pradesh |
| Description : | total quantity = 148 ----- document required from seller = certificate (requested in atc),additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),compliance of boq specification and supporting document |
| T18 Ref No: | 16356354 | Tender Value: | Refer Document |
|---|---|---|---|
| Tender ID: | GEM/2026/B/7818145 | Tender EMD: | Refer Document |
| Tender Agency: | bharat heavy electricals limited BHEL | Tender Fee: | Refer Document |
| City: | huzur | Published Date: | Jul 22, 2026 |
| State: | madhya pradesh | Due Date: | Aug 01, 2026 |
| Tender Related Keywords : | - | Tender Opening Date: | Aug 01, 2026 |
| Description : | total quantity = 148 ----- document required from seller = certificate (requested in atc),additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),compliance of boq specification and supporting document | ||
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.