tender for following digital kwh meter for 750 kva cummins ea etc as reqd , supplying, replacement and fixing digital multi function meter for 750 kva cummins ea set as reqd , supplying and fixing yellow or red or green led indicators lamp 750 kva cummins ea set as reqd , supplying, replacement and fixing blue led indicators lamp for 750 kva cummins ea set as reqd , supplying, replacement and fixing auto manual selector switch for 750 kva cummins ea set as reqd , supplying, replacement and fixing ac voltmeter 96 sq.mm 0 to 500 volt for 750 kva ea set as reqd , supplying, replacement and fixing ac ammeter 96 sq.mm 0 to 1200 a for 750 kva ea set as required , supplying, replacement and fixing 6a selecter switch with control wiring, ass or vss for 750 kva ea. , supplying, replacement and fixing faulty fuel level gauge for 750 kva ea set complete as reqd , supplying, replacement and fixing 6 a to 32a , 230 v, sp mcb c series as reqd. , supplying, replacement and fixing on existing pole or bracket 45 watt led street light. , rewinding and installation of 10 hp monoblock water pump set incl. connection etc reqd. , attending defects in existing fd and fa incl. repairing of faulty , detectors etc, as reqd. , refilling of 4.5 kg co2 type fire extinguishers upto standard pressure, valve leakage test as reqd. , gi fire bucket and suitable bracket, note one set comprises 3 nos buckets , supply installation testing and commissioning of starting capacitor 80 to 100 mfd compatible with 1.5 and 2 tr split ac system as required , supply installation testing and commissioning of running capacitor 36 to 50 mfd compatible with 1.5 or 2 tr split ac system as required , supply installation testing and commissioning of capacitor for condenser fan 4 to 6 mfd compatible with 1.5 or 2.0 tr split ac system reqd , supply installation testing and commissioning of sensor for split ac unit compatible with 1.5 or 2.0 tr split ac system as reqd , supply installation testing and commissioning of contactor relay for split ac outdoor unit, for 1.5 or 2.0 tr split ac system as reqd , supply installation testing and commissioning of starting relay of same make and model compatible with 1.5 or 2 tr split ac as reqd , supply installation testing and commissioning of thermostat same make and model compatible with 1.5 or 2 tr split ac system as required , supply installation testing and commissioning of selector switch of same make and model compatible, ocm of ems at telecom compound bhavanipeth pune attending defects, supplying , replacement and toping transformer oil compatible with 11 kv by 415 v, 750 kva outdoor tye plint mounted onan cooled tfr , kirloskar make complete as required ., supplying, replacement and fixing breather and silica gel, same make and model compatible with 11 kv by 415 v , 750 kva outdoor type plint mounted onan cooled, kirloskar make complete as required, attending transformer oil leakage in bush, body, side glass, including replacement of gasket of 11 kv by 415 v,750 kva outdoor tye plint mounted onan cooled, kirloskar make etc as reqd., supplying, replacement and fixing 11 kv air break gang operated switch , 1 set equal to 3 poles of same make and model compatible with 11 kv by 415v, 750 kva trf od type plint mounted as reqd, supplying, replacement and fixing lightning arrester, 1 set comprises 3 nos, of same make and model compatible with 11 kv by 415v, 750 kva tfr outdoor type plint mounted onan cooled, as required, servicing of 800 a to 1250 a , 415 v, ge make air circuit breaker incl. calibration of relay, contacts tension checking, etc complete as required, supplying, replacement and fixing uv coil of same make and model for air circuit breaker etc complete as required, supplying, replacement and fixing shunt coil of same make and model compatible for air circuit breaker etc complete as required, supplying, replacement and fixing 32a , 415 v, tpn or tp switch or sdf switch etc complete as required ., supplying, replacement and fixing 63a, 415 v, tpn or tp switch or sdf switch etc complete as required, supplying, replacement and fixing 125 a, 415 v, tpn or tp switch or sdf switch etc complete as required, supplying, replacement and fixing cylindrical fuse links suitable for type fn 63, fnx 63 sdf and for hc 63 fuse base, 40 to 63 a etc complete as required, supplying, replacement and fixing 25 kvar md xl capacitor etc complete as required, supplying, replacement and fixing 20 kvar md xl capacitor etc complete as required, supplying, replacement and fixing 10 kvar md xl capacitor etc complete as required, repairing of electrical and mechanical interlocking between the incomers including replacement of mechanical locks, wiring and testing etc complete as required, supplying, replacement and fixing digital ammeter same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing digital voltmeter of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing digital frequency meter of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing following digital kwh meter of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing digital multi function meter of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying and fixing yellow or red or green led indicators lamp of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing blue led indicators lamp same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing auto manual selector switch of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing ac voltmeter 96 sq.mm and 0 to 500 volt of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing ac ammeter 96 sq.mm 0 to 1200 a of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing of 6a selecter switch with control wiring. ass or vss , same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing faulty fuel level gauge of same make and model compatible with 750 kva cummins ea set with canopy complete as required, supplying, replacement and fixing 6 a to 32a , 230 v, sp mcb c series of same make and model compatible with ei and fans complete as required, suppying, replacement and fixing on existing pole or bracket 45 watt led street light, housing made up of die cast alluminium with street optic lens and polycarbonate diffuser and ip66 protection, rewinding and installation of 10 hp monoblock water pump set incl. connection of suction, delivery line, cable connection, t and c with s and f motor pump end cover,replacing gland packing etc reqd., attending defects in existing fire detection and fire alarm system incl. repairing of control cards, faulty hooters, detectors, ri, mcp and control wiring of panels to existing system etc. as reqd., refilling of 4.5 kg co2 type fire extinguishers upto standard pressure, valve leakage test as per is 2190 2024 incl. replacement of horn and pressure pipe, handling, to and fro transport, etc as reqd., gi fire bucket and suitable bracke, note one set comprises 3 nos buckets, supply installation testing and commissioning of starting capacitor 80 to 100 mfd of same make and model compatible with 1.5 and 2.0 tr split ac system complete as required, supply installation testing and commissioning of running capacitor 36 to 50 mfd of same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of capacitor for condenser fan 4 to 6 mfd of same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of sensor for split ac unit of same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of contactor relay for split ac outdoor unit same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of starting relay of same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of thermostat same make and model compatible with 1.5 or 2.0 tr split ac system complete as required, supply installation testing and commissioning of selector switch of same make and model compatible with 1.5 or 2.0 tr split ac system complete as required