corrigendum tender for 676201010013 , 676080301010 , 676060320001 , 676060370000 , 676080371002 , 676000371018 , 676015461006 , 676000481006 , 676060466000 , 676015700006 , 401104061004 , 610120005681 , 610105001008 , 460145040001 , 460145048267 , 846001500002 , 401125701003 , 750170626009 , 750170626007 , 685800059885 , 650110070008 , 511020045547 , 740115007650 , 681515110000 , 681515121010 , 763313996930 , 746205151121 , 674003418229 , 674010431004 , 674003418231 , 674003414613 , 674003418227 , 674003418221 , 674003411067 , 674003410076 , 674003410060 , 674003410068 , 677015200025 , 677001230001 , 677510109924 , 678004100002 , 677510109954 , 630501341113 , 733020991028, procurement of miscellaneous items for electrical at dvc rtps, as per attached specification hrc fuse4a; breaking capacity-80 ka; type: hg; sizef1;415v ac, isi marked;, 10 amp, 415 v, hrc fuses type: ns, minimum breaking capacity: 80 ka, as per is:13703 (part ii), hrc fuse16a; breaking capacity-80 ka; type: hf; size14x51;415v ac, isi marked;, hrc fuse -32a, breaking capacity-80 ka, type-hf, size- 14 x 51; 415v ac, isi marked;, hrc fuse, ns type cylindrical knife type, 415v ac, rated 32a, breaking capacity 80kamp., hrc fuse, din type, 415v ac, rating 32a, breaking capacity 80ka, size 00, hrc fuse rating 63a, din type, size-00, hrc fuse, din type, 415v ac, rating 80 amp, breaking capacity 80ka, size 00., hrc fuse offset bolted tag, gg/a3/63a/500v ac/ 80 ka, type:tis., hrc fuse-400a,415v, size-2, breaking capacity-100ka, gg, type-hn, is:13703(part ii), iec:60269-2., 1) selfbonding ht insulation tape .2) ethylene propylene rubber based material. 3) excellent moisture resistance and high dielectric strength. 4) the product should be used for high voltage (upto 35 kv) applications 5) package type: role. 6) dimension: (for one roll) thickness- 0.7 to 0.8 mm with- 35 to 39 mm length: 8 to 10 mtrs, heat shrinkable insulation tube for use in 11kv switchboard, size 100/40. details dimension sheet attached., equivalent to type heat sinkable ht insulator sleeve/ tube, size: 30/12 with minimum bdv-3.3 kv, 1 no of 50 mtr length., welding receptacle of 63 amp (3p +n+e) including plug socket with tpn mcb made of high quality thermoplastic polycarbonate dust and jet water proof, chemical, acid corrosion, weather, impact, insulated and shock proof with internally embedded gasket., welding receptacle of 125amp, 415 volts, 3 phase 5 pin ip67 including plug&socket with enclosure-thermoplastic polycarbonate, degree of protection ip65, system voltage-415v, 50hz, 4 wire+e, hypoxy steel bond ( 454 gram pack ), 750 ml bottle of polyurethane expandable foam gap filler., indicating lamp for panel cutouts, led based rated voltage: 240v ac/dc led indication lamp lense colour: red lamp suitable for panel cutout sizes (in mm): 22.5mm shape of indication lamp: round., indicating lamp for panel cutouts, led based rated voltage: 240v ac/dc led indication lamp lense colour: green lamp suitable for panel cutout sizes (in mm): 22.5mm shape of indication lamp: round., clear view silica gel breather filled with blue silica gel (08-10 mesh), 0.5kg capacity,3/4 inch (bsp threaded), pvc sheathed copper flexible cable, 4cx6 sqmm, 1100v grade, pvc/xlpe/e pr insulated, ,suited for trailing cable of electrical hoist, conformity to is 694, is:7098 (part 1): 1988 latest, type of outer sheath : pvc-st2 & is:5831:1984 latest, pendent with 6 no push button and emergency stop button.one indication lamp (red colour)., solid state rectifier,type- st 2018, 415v ac/190 vdc, 2 amp, 6 terminal, suitable for hoist control panel, control transformer, 415 v ac/110 v ac, 250 va, suitable for reva make hoist control panel, control transformer 415/240v ac, 2kva, suitable for mill lop motor control panel, electrical transducer,type: current(trms), model: rish con i, input:0...5a, output: 4...20ma, supply: 60 to 300 v ac/dc, v ac/dc,duel output, din rail mounting. make: rishabh, rtd pt 100 (without thermowell) insertion length- 150mm, three wire., 220v dc,two pole mcb 2amp., 220v dc, two pole mcb 63amp, short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., 240/415v ac;, 240/415v ac;, 240/415v ac, 240v ac, single pole mcb 16amp/250v short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., 02 pole ,16a mcb ,suitable for 240 / 415 v ac,curve- c, rated short circuit capacity- 10ka as per is/iec 60898 : part 1:2015, 415v ac,three pole mcb 16amp, short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., no of pole: triple pole rated voltage (in volts): 240 / 415 v, ac rated current (in ampere): 32a instantaneous tripping current type: type c rated short circuit capacity (in ampere): 10ka mcb as per is/iec 60898 : part 1:2015 latest, power contactor 18a-440v, 3p, ac-3, coil voltage- 110v ac, with 1no (in built ), 50/60hz, height- 85mm, width- 45mm, depth- 92mm, din rail mounted, power contactor 32a-440v, 3p, ac-3, coil voltage- 110v ac, with 1no (in built ), 50/60hz, height- 85mm, width- 45mm, depth- 92mm, din rail mounted, thermal o/l relay, 1-1.6a, 415v, 3p, 1no-1nc, height-66mm, width-45mm, depth-70mm, din rail mounted, thermal overload relay, range- 2.5-4 a, model: lrd08, direct mounting, conformity to international standard- iec, ul, csa, thermal o/l relay, 16-24a, 415v, 3p, 1no-1nc, height-66mm, width-45mm, depth-70mm,din rail mounted, capacity: 415v-420kv, feature: non-contact work by proximity,indication: acoustic and visual indicators, length of insulated stick: minimum 4 mtr, insulated stick type: telescopic and compatible with most hot sticks, self-test: automatic self-test function to verify function of detector, site requirement: lig weight, robust & compact, suitability: suitable for indoor and outdoor use, other detection features: low battery indication and capable to detect live and induction voltage, distance for detection: line voltage detection (400kv) shall be less than 6 meters with respect to live conductor, safety standard: en 61326-1, en 61000-4-2, en 61000-4-3, en 55011; central govt/nabl/tlac accredited lab test report: to be submitted with bid., sealed lead acid battery, 12v, 7ah

Latest Tender Detail from damodar valley corporation DVC for the corrigendum tender for 676201010013 , 676080301010 , 676060320001 , 676060370000 , 676080371002 , 676000371018 , 676015461006 , 676000481006 , 676060466000 , 676015700006 , 401104061004 , 610120005681 , 610105001008 , 460145040001 , 460145048267 , 846001500002 , 401125701003 , 750170626009 , 750170626007 , 685800059885 , 650110070008 , 511020045547 , 740115007650 , 681515110000 , 681515121010 , 763313996930 , 746205151121 , 674003418229 , 674010431004 , 674003418231 , 674003414613 , 674003418227 , 674003418221 , 674003411067 , 674003410076 , 674003410060 , 674003410068 , 677015200025 , 677001230001 , 677510109924 , 678004100002 , 677510109954 , 630501341113 , 733020991028, procurement of miscellaneous items for electrical at dvc rtps, as per attached specification hrc fuse4a; breaking capacity-80 ka; type: hg; sizef1;415v ac, isi marked;, 10 amp, 415 v, hrc fuses type: ns, minimum breaking capacity: 80 ka, as per is:13703 (part ii), hrc fuse16a; breaking capacity-80 ka; type: hf; size14x51;415v ac, isi marked;, hrc fuse -32a, breaking capacity-80 ka, type-hf, size- 14 x 51; 415v ac, isi marked;, hrc fuse, ns type cylindrical knife type, 415v ac, rated 32a, breaking capacity 80kamp., hrc fuse, din type, 415v ac, rating 32a, breaking capacity 80ka, size 00, hrc fuse rating 63a, din type, size-00, hrc fuse, din type, 415v ac, rating 80 amp, breaking capacity 80ka, size 00., hrc fuse offset bolted tag, gg/a3/63a/500v ac/ 80 ka, type:tis., hrc fuse-400a,415v, size-2, breaking capacity-100ka, gg, type-hn, is:13703(part ii), iec:60269-2., 1) selfbonding ht insulation tape .2) ethylene propylene rubber based material. 3) excellent moisture resistance and high dielectric strength. 4) the product should be used for high voltage (upto 35 kv) applications 5) package type: role. 6) dimension: (for one roll) thickness- 0.7 to 0.8 mm with- 35 to 39 mm length: 8 to 10 mtrs, heat shrinkable insulation tube for use in 11kv switchboard, size 100/40. details dimension sheet attached., equivalent to type heat sinkable ht insulator sleeve/ tube, size: 30/12 with minimum bdv-3.3 kv, 1 no of 50 mtr length., welding receptacle of 63 amp (3p +n+e) including plug socket with tpn mcb made of high quality thermoplastic polycarbonate dust and jet water proof, chemical, acid corrosion, weather, impact, insulated and shock proof with internally embedded gasket., welding receptacle of 125amp, 415 volts, 3 phase 5 pin ip67 including plug&socket with enclosure-thermoplastic polycarbonate, degree of protection ip65, system voltage-415v, 50hz, 4 wire+e, hypoxy steel bond ( 454 gram pack ), 750 ml bottle of polyurethane expandable foam gap filler., indicating lamp for panel cutouts, led based rated voltage: 240v ac/dc led indication lamp lense colour: red lamp suitable for panel cutout sizes (in mm): 22.5mm shape of indication lamp: round., indicating lamp for panel cutouts, led based rated voltage: 240v ac/dc led indication lamp lense colour: green lamp suitable for panel cutout sizes (in mm): 22.5mm shape of indication lamp: round., clear view silica gel breather filled with blue silica gel (08-10 mesh), 0.5kg capacity,3/4 inch (bsp threaded), pvc sheathed copper flexible cable, 4cx6 sqmm, 1100v grade, pvc/xlpe/e pr insulated, ,suited for trailing cable of electrical hoist, conformity to is 694, is:7098 (part 1): 1988 latest, type of outer sheath : pvc-st2 & is:5831:1984 latest, pendent with 6 no push button and emergency stop button.one indication lamp (red colour)., solid state rectifier,type- st 2018, 415v ac/190 vdc, 2 amp, 6 terminal, suitable for hoist control panel, control transformer, 415 v ac/110 v ac, 250 va, suitable for reva make hoist control panel, control transformer 415/240v ac, 2kva, suitable for mill lop motor control panel, electrical transducer,type: current(trms), model: rish con i, input:0...5a, output: 4...20ma, supply: 60 to 300 v ac/dc, v ac/dc,duel output, din rail mounting. make: rishabh, rtd pt 100 (without thermowell) insertion length- 150mm, three wire., 220v dc,two pole mcb 2amp., 220v dc, two pole mcb 63amp, short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., 240/415v ac;, 240/415v ac;, 240/415v ac, 240v ac, single pole mcb 16amp/250v short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., 02 pole ,16a mcb ,suitable for 240 / 415 v ac,curve- c, rated short circuit capacity- 10ka as per is/iec 60898 : part 1:2015, 415v ac,three pole mcb 16amp, short circuit breaking capacity: 10 ka minimum. tripping characteristic curve: type "c"., no of pole: triple pole rated voltage (in volts): 240 / 415 v, ac rated current (in ampere): 32a instantaneous tripping current type: type c rated short circuit capacity (in ampere): 10ka mcb as per is/iec 60898 : part 1:2015 latest, power contactor 18a-440v, 3p, ac-3, coil voltage- 110v ac, with 1no (in built ), 50/60hz, height- 85mm, width- 45mm, depth- 92mm, din rail mounted, power contactor 32a-440v, 3p, ac-3, coil voltage- 110v ac, with 1no (in built ), 50/60hz, height- 85mm, width- 45mm, depth- 92mm, din rail mounted, thermal o/l relay, 1-1.6a, 415v, 3p, 1no-1nc, height-66mm, width-45mm, depth-70mm, din rail mounted, thermal overload relay, range- 2.5-4 a, model: lrd08, direct mounting, conformity to international standard- iec, ul, csa, thermal o/l relay, 16-24a, 415v, 3p, 1no-1nc, height-66mm, width-45mm, depth-70mm,din rail mounted, capacity: 415v-420kv, feature: non-contact work by proximity,indication: acoustic and visual indicators, length of insulated stick: minimum 4 mtr, insulated stick type: telescopic and compatible with most hot sticks, self-test: automatic self-test function to verify function of detector, site requirement: lig weight, robust & compact, suitability: suitable for indoor and outdoor use, other detection features: low battery indication and capable to detect live and induction voltage, distance for detection: line voltage detection (400kv) shall be less than 6 meters with respect to live conductor, safety standard: en 61326-1, en 61000-4-2, en 61000-4-3, en 55011; central govt/nabl/tlac accredited lab test report: to be submitted with bid., sealed lead acid battery, 12v, 7ah in raghuathpur, west bengal,. Reference number 15424126. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15424126
Tender ID:GEM/2026/B/7457094
Tender Agency:damodar valley corporation DVC
City:raghuathpur
State:west bengal
Tender Related Keywords :socket, valve
Description :total quantity = 1756
Tender Value:1045918.21
Tender EMD:Refer Document
Tender Fee:Refer Document
Published Date:May 18, 2026
Due Date:May 25, 2026
Tender Opening Date:May 25, 2026
Tender DocumentsDownload Document
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Inquiry