corrigendum tender for supply of 1.5 tr inverter type 5 star rated split air- conditioner unit , dismantling of existing 1.5 tr split ac unit , installation, testing and commissioning of the split ac unit , supplying and fixing extra copper pipe line , supplying and laying 4 core 2.5 sq. mm pvc insulated and pvc sheathed flexible copper cable , supplying and fixing of powder coated ms frame stand , supplying and fixing of 20 mm dia heavy duty pvc pipe with accessories for drain water connection , supplying and laying of pvc insulated and pvc round sheathed, 3 core ,2.5 sqmm, 1.1kv copper cable , supplying and fixing dp sheet steel enclosure on surface or recess along with 25,32a 240v, supply installation testing and commissioning of split ac units at cto kolkata, supply of 1.5 tr inverter type 5 star rated split air-conditioner unit as per bee star rating, (as per new bee rating valid for 1st january 2026 to 31 december 2027 ) with remote control unit, filters, rotary type compressor, copper tubes for both indoor and outdoor unit, refrigerant gas with topping up of refrigerant if required, transportation of all of the above to the various sites and supplying the following up to the length of 3 mtrs etc. as required. (1) hot and cold refrigerant piping (2) suitable connecting electrical cable between indoor and outdoor unit. note-- 1) the manufacturers / suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation, which is earlier. thereafter 9 years (108 months) additional warranty on the compressor., dismantling of existing 1.5 tr split ac unit - indoor and outdoor units alongwith interconnecting cu pipe and cable , power connection cable etc - and storing at place shown by exch in charge etc as reqd, installation, testing and commissioning of the split ac unit at a specified location by mounting and fitting indoor and outdoor units at their respective locations , laying and fixing of both liquid and hot gas lines, interconnecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene foam tubing unit , leak testing entire system ,charging refrigerant gas in the unit ,making power supply connections from the power point etc complete as required., supplying and fixing extra copper pipe line both 1/4 inch for gas line and 5/8 inch for liquid line or suitable dia to match with the pipeline of the new unit along with suitable size rubber foam/insulation on surface of the wall i/c necessary flare nuts, suitably brazing with the existing pipe clamping, making holes in walls, same etc., as per site requirement. note - the length of refrigerant pipes supplied with each ac units is 3 mtr. extra length shall be paid extra for which firm shall quote their unit rates., supplying and laying 4 core 2.5sq.mm pvc insulated and pvc sheathed flexible copper cable along refrigerant pipe or on existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc, as required . (make- any isi mark ) . note- the length of copper cable supplied with each unit is 3 mtr . extra length shall be paid extra., supplying and fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good damages etc as per site requirement ., supplying and fixing of 20 mm dia heavy duty pvc pipe with accessories for drain water connection where ever required etc. complete as required.(make- any isi mark ) ., supplying and laying of pvc insulated and pvc round sheathed, 3 core ,2.5 sqmm, 1.1kv copper cable ( un-aoumerd ) including connection , testing checking etc as complete as required, supplying and fixing dp sheet steel enclosure on surface or recess along with 25,32a 240v c curve dp mcb complete with connections ,testing and commissioning etc. as complete as reqd.

Latest Tender Detail from bharat sanchar nigam limited BSNL for the corrigendum tender for supply of 1.5 tr inverter type 5 star rated split air- conditioner unit , dismantling of existing 1.5 tr split ac unit , installation, testing and commissioning of the split ac unit , supplying and fixing extra copper pipe line , supplying and laying 4 core 2.5 sq. mm pvc insulated and pvc sheathed flexible copper cable , supplying and fixing of powder coated ms frame stand , supplying and fixing of 20 mm dia heavy duty pvc pipe with accessories for drain water connection , supplying and laying of pvc insulated and pvc round sheathed, 3 core ,2.5 sqmm, 1.1kv copper cable , supplying and fixing dp sheet steel enclosure on surface or recess along with 25,32a 240v, supply installation testing and commissioning of split ac units at cto kolkata, supply of 1.5 tr inverter type 5 star rated split air-conditioner unit as per bee star rating, (as per new bee rating valid for 1st january 2026 to 31 december 2027 ) with remote control unit, filters, rotary type compressor, copper tubes for both indoor and outdoor unit, refrigerant gas with topping up of refrigerant if required, transportation of all of the above to the various sites and supplying the following up to the length of 3 mtrs etc. as required. (1) hot and cold refrigerant piping (2) suitable connecting electrical cable between indoor and outdoor unit. note-- 1) the manufacturers / suppliers shall give a warranty of the air conditioner for 15 months from date of supply or 12 months from date of installation, which is earlier. thereafter 9 years (108 months) additional warranty on the compressor., dismantling of existing 1.5 tr split ac unit - indoor and outdoor units alongwith interconnecting cu pipe and cable , power connection cable etc - and storing at place shown by exch in charge etc as reqd, installation, testing and commissioning of the split ac unit at a specified location by mounting and fitting indoor and outdoor units at their respective locations , laying and fixing of both liquid and hot gas lines, interconnecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene foam tubing unit , leak testing entire system ,charging refrigerant gas in the unit ,making power supply connections from the power point etc complete as required., supplying and fixing extra copper pipe line both 1/4 inch for gas line and 5/8 inch for liquid line or suitable dia to match with the pipeline of the new unit along with suitable size rubber foam/insulation on surface of the wall i/c necessary flare nuts, suitably brazing with the existing pipe clamping, making holes in walls, same etc., as per site requirement. note - the length of refrigerant pipes supplied with each ac units is 3 mtr. extra length shall be paid extra for which firm shall quote their unit rates., supplying and laying 4 core 2.5sq.mm pvc insulated and pvc sheathed flexible copper cable along refrigerant pipe or on existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc, as required . (make- any isi mark ) . note- the length of copper cable supplied with each unit is 3 mtr . extra length shall be paid extra., supplying and fixing of powder coated ms frame stand comprising of two numbers bracket made of heavy duty ms sheet to accommodate the condenser (outdoor) unit for fixing on the wall with suitable diameter and length of anchor fast bolts and making good damages etc as per site requirement ., supplying and fixing of 20 mm dia heavy duty pvc pipe with accessories for drain water connection where ever required etc. complete as required.(make- any isi mark ) ., supplying and laying of pvc insulated and pvc round sheathed, 3 core ,2.5 sqmm, 1.1kv copper cable ( un-aoumerd ) including connection , testing checking etc as complete as required, supplying and fixing dp sheet steel enclosure on surface or recess along with 25,32a 240v c curve dp mcb complete with connections ,testing and commissioning etc. as complete as reqd. in kolkata, west bengal,. Reference number 15423685. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15423685
Tender ID:GEM/2026/B/7503921
Tender Agency:bharat sanchar nigam limited BSNL
City:kolkata
State:west bengal
Tender Related Keywords :systems, service
Description :total quantity = 126 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),additional doc 4 (requested in atc) ----- evaluation method = total value wise evaluation
Tender Value:330438
Tender EMD:Refer Document
Tender Fee:Refer Document
Published Date:May 19, 2026
Due Date:May 22, 2026
Tender Opening Date:May 22, 2026
Tender DocumentsDownload Document
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Inquiry