Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

17Latest Refrigerant r410a Tenders List

Latest Refrigerant r410a Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Refrigerant r410a tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Refrigerant r410a tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Refrigerant r410a Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Refrigerant r410a tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Refrigerant r410a Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Refrigerant r410a Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Refrigerant r410a Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Refrigerant r410a tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Refrigerant r410a Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Refrigerant r410a sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Refrigerant r410a tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Refrigerant r410a tenders.

Is EMD mandatory for all Refrigerant r410a tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Refrigerant r410a work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Refrigerant r410a tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Refrigerant r410a Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 16877656
Location : krishnagar , west bengal
Source : GEM Tenders
LIVE TENDER
tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0 tr hi- wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , supply installation testing and commissioning of 3.0tr cassette type split systems , copper refrigerant piping for 1.5tr and 2.0tr hi-wall split ac , copper refrigerant piping for 2.0tr and 3.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr and 2.0 tr hi-wall split ac , outdoor stand for 2.0tr and 3.0 tr cassette type split units , 4 inch dia pvc pipe , supply and laying of suitable flexible cable from outdoor to indoor, airconditioners for mini racpc, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating,isser value minimum value 5.6, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, isser value minimum value 5.6 ., supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , isser value minimum value 5.6 ., supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is 1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required.inverter type cooling with 5 star bee rating, isser value minimum value 5.6 ., supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supply ,installation of minimum 4 inch dia heavy duty pvc pipe with all hanging supports required at regular intervals for laying copper and drain piping in banking, supply and fixing of four core cable
T18 Ref No : 16857959
Location : uppal , telangana
Source : GEM Tenders
LIVE TENDER
tender for routine dry service of split ac , wet chemical service of split ac , refrigerant gas charging r22, r32, r410a , leak detection and rectification , supply and installation of compressor 1.5 ton , supply and installation of indoor pcb , supply and installation of outdoor pcb , supply and installation of capacitor , supply and installation of relay, contactor , supply and installation of outdoor fan motor , supply and installation of indoor blower motor , supply and installation of blower fan , supply and installation of cooling sensor , supply and installation of thermostat , supply and installation of display board , supply and installation of evaporator coil , supply and installation of outdoor condenser coil , supply and installation of copper pipe 3 by 8 in , supply and installation of copper pipe 5 by 8 in , supply and installation of pipe insulation , supply and installation of drain pipe , supply of compatible remote controller , breakdown maintenance visit inspection, fault diagnosis and testing , replacement of ahu pre filter , replacement of ahu fine filter , repair replacement of 5.5 kw ahu fan motor , replacement of bearings or belts or couplings , amc visit of hvac system half-yearly, r and m of ac hvac at hcpl crs, routine dry service of split ac, wet chemical service of split ac, refrigerant gas charging r22, r32, r410a, leak detection and rectification, supply and installation of compressor 1.5 ton, supply and installation of indoor pcb, supply and installation of outdoor pcb, supply and installation of capacitor, supply and installation of relay, contactor, supply and installation of outdoor fan motor, supply and installation of indoor blower motor, supply and installation of blower fan, supply and installation of cooling sensor, supply and installation of thermostat, supply and installation of display board, supply and installation of evaporator coil, supply and installation of outdoor condenser coil, supply and installation of copper pipe 3 by 8 in, supply and installation of copper pipe 5 by 8 in, supply and installation of pipe insulation, supply and installation of drain pipe, supply of compatible remote controller, breakdown maintenance visit inspection, fault diagnosis and testing, replacement of ahu pre filter, replacement of ahu fine filter, repair replacement of 5.5 kw ahu fan motor, replacement of bearings or belts or couplings, amc visit of hvac system half-yearly
T18 Ref No : 16668999
Location : dungarpur , rajasthan
Source : GEM Tenders
LIVE TENDER
tender for 1.5 ton split inverter air conditioner , inverter with battery set , electric iron press , ironing table iron table , shoe polish machine, boq titl, wall mounted split inverter air conditioner, cooling only type, with 1.5 ton capacity and cooling capacity of approximately 5000 watt or higher. the air conditioner shall have bee 3 star rating or above with the latest valid bee label, wherever applicable. it shall be equipped with 100 percent copper condenser coil and r32, r410a, or the latest environment friendly refrigerant as per applicable norms. the unit shall operate on 230 volt ac, 50 hertz, single phase power supply and provide high ambient cooling at 48 degrees celsius or above. the air conditioner shall include anti dust filter, auto restart, sleep mode, remote control, indoor unit, and outdoor unit. the standard installation kit shall include a minimum 3 meter copper pipe, drain pipe, electrical wire, remote control, user manual, and outdoor unit stand or bracket. the product shall carry a minimum one year comprehensive warranty and compressor warranty as per oem standard, complete inverter battery set consisting of one pure sine wave inverter and a lithium iron phosphate battery bank. the inverter capacity shall be minimum 3.5 kva, 48 volt or higher and shall be fully compatible with the supplied lithium battery bank. the system shall have 230 volt ac input and 230 volt ac output with 10 percent permissible variation at 50 hertz frequency. the inverter shall be equipped with overload protection, short circuit protection, battery deep discharge protection, overcharging protection, mcb or fuse protection and led or lcd display for mains supply, battery level, charging and overload status. the battery bank shall be lithium iron phosphate type with minimum 48 volt and 150 ampere hour capacity, inbuilt battery management system, low maintenance and suitable for inverter application. lead acid and tall tubular batteries shall not be accepted. the lithium battery shall carry a minimum warranty of 36 months or higher. the complete set shall be supplied with a suitable battery rack or trolley, required battery cables, connectors, safety accessories and installation material. the supplier shall installation , test and demonstrate the complete working of the inverter and lithium battery system at the consignee location., electric dry iron suitable for regular institutional use, foldable ironing table suitable for domestic, automatic shoe polish machine suitable for office

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16086325
Location : bangalore , karnataka
Source : GEM Tenders
corrigendum tender for supply installation testing and comissioning of vrf , supply installation testing and comissioning of indoor unit , supply installation testing and comissioning of joints , supply of cables , supply installation testing and comissioning of switch boxes , supply installation testing and comissioning of copper pipes , drain pipe , refrigerant , material shifting , supply installation of cable tray , core cutting , s i of distribution box , laying of cable , termination of cable , dismantelling , pop gypsum work, casset ac installation for rtamc, supplying, installation, testing & commissioning of variable refrigerant flow/variable refrigerant volume air cooled outdoor units alongwith outdoor stand as per ts for cooling --10hp, supplying, installation, testing and commissioning of following minimum capacity 4 way cassette type indoor ceiling mounted unit including wireless remote as per ts (make will be same as of outdoor)--3.2 tr, supplying, installation, testing and commissioning of y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supply of 3c x 2.5sqmm flexible cable for idu power, supplying, installation, testing and commissioning of 5amps switch box (5a switch+5a socket on 3 module box), supply of 4c x 16sqmm pvc/xlpe armoured copper cable, supply & installation/laying of copper pipe for refrigerant with insulation and support etc., as required, supply & laying of 2 core 1.0-1.5 sqmm communication cable between idu and odu inside rigid/flexible pvc conduit wherever required, supply & fixing cpvc drain pipe 25/32mm with supports as per site conditions, supply and topping up refrigerant r410a/r32 as applicable (if required), lifting & shifting of 01 nos odu with crane/manually to site as per direction of eic with complete safety, supply & installation/laying of 100/200mm cable tray with closure as per site conditions with complete safety, core cutting works as per site condition, supply and installation of ip-65/66 stainless steel (304 grade) or powder-coated galvanized steel outdoor distribution box of appropriate size (should be spacious) near odu with 63a - 2 nos mcb and accessories (ie lugs cable tie wires screws bn etc), laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size in the existing masonry open/close duct as required.-upto 35 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. -upto 35 sq. mm (clamped with 1mm thick saddle), supplying and making end termination with brass/aluminium compression gland and copper lugs for following size of pvc insulated and pvc sheathed / xlpe copper conductor cable of 1.1 kv grade as required.--4 x 16 sq. mm (28mm), service charges for dismantling handing over of an existing cassette idu(samsung make) - 1.2 or 1.3tr(pump down pressure testing refilling of gas), dismantling/cutting out of existing pop/gypsum ceiling and shifting the debris outside powergrid campus, supply and installation of pop/gypsum work includes gypsum board, pop powder, putty and paint etc., (for making ceiling as per its earlier form)
T18 Ref No : 16172946
Location : bangalore , karnataka
Source : GEM Tenders
corrigendum tender for supply installation testing and comissioning of vrf , supply installation testing and comissioning of indoor unit , supply installation testing and comissioning of joints , supply of cables , supply installation testing and comissioning of switch boxes , supply installation testing and comissioning of copper pipes , drain pipe , refrigerant , material shifting , supply installation of cable tray , core cutting , s i of distribution box , laying of cable , termination of cable , dismantelling , pop gypsum work, casset ac installation for rtamc, supplying, installation, testing & commissioning of variable refrigerant flow/variable refrigerant volume air cooled outdoor units alongwith outdoor stand as per ts for cooling --10hp, supplying, installation, testing and commissioning of following minimum capacity 4 way cassette type indoor ceiling mounted unit including wireless remote as per ts (make will be same as of outdoor)--3.2 tr, supplying, installation, testing and commissioning of y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supply of 3c x 2.5sqmm flexible cable for idu power, supplying, installation, testing and commissioning of 5amps switch box (5a switch+5a socket on 3 module box), supply of 4c x 16sqmm pvc/xlpe armoured copper cable, supply & installation/laying of copper pipe for refrigerant with insulation and support etc., as required, supply & laying of 2 core 1.0-1.5 sqmm communication cable between idu and odu inside rigid/flexible pvc conduit wherever required, supply & fixing cpvc drain pipe 25/32mm with supports as per site conditions, supply and topping up refrigerant r410a/r32 as applicable (if required), lifting & shifting of 01 nos odu with crane/manually to site as per direction of eic with complete safety, supply & installation/laying of 100/200mm cable tray with closure as per site conditions with complete safety, core cutting works as per site condition, supply and installation of ip-65/66 stainless steel (304 grade) or powder-coated galvanized steel outdoor distribution box of appropriate size (should be spacious) near odu with 63a - 2 nos mcb and accessories (ie lugs cable tie wires screws bn etc), laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size in the existing masonry open/close duct as required.-upto 35 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. -upto 35 sq. mm (clamped with 1mm thick saddle), supplying and making end termination with brass/aluminium compression gland and copper lugs for following size of pvc insulated and pvc sheathed / xlpe copper conductor cable of 1.1 kv grade as required.--4 x 16 sq. mm (28mm), service charges for dismantling handing over of an existing cassette idu(samsung make) - 1.2 or 1.3tr(pump down pressure testing refilling of gas), dismantling/cutting out of existing pop/gypsum ceiling and shifting the debris outside powergrid campus, supply and installation of pop/gypsum work includes gypsum board, pop powder, putty and paint etc., (for making ceiling as per its earlier form)
T18 Ref No : 15826870
Location : kamrup , assam
Source : GEM Tenders
tender for odu 1 , odu 2 , 4-way cassette unit 1 , 4-way cassette unit 2 , y joints 1 , y joints 2 , cu piping , damper , actuator , nitrile rubber , wiring , mccb , mcb db 1 , mcb db 2 , mcb , allied electrical works , dx coil unit , 4-way cassette unit 3 , ahu , ahu kit , ref gas , control cable , drain pipe , ducting , acoustic nitrile rubber , vfd , strip heater , pdp , al cable 1 , al cable 2, supply installation testing and commissioning of vrf based air conditioning system, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 14 hp, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 10 hp, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.56 tr, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.0 tr, supplying, installation, testing and commissioning of odu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supplying, installation, testing and commissioning of idu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, refrigerant piping for vrf system - supply , installation , testing and commissioning of copper piping in brazed construciton, complete with nitrile rubber insulation, supports/suspenders, as per enclosed specifications. refrigerant piping for suction gas with 19mm thick nitrile insulation & refrigerant piping for liquid gas with 13mm thick nitrile insulation (various capacities as per boq of nit document, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - damper, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - actuator, supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (class-o) insulation on existing duct as per nit specifications - 25mm, wiring for circuit/ submain wiring along with earth wire as per nit specifications, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board as per nit specifications, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing following way, tpn, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka mcbs as per boq enclosed with nit document, allied electrical works as per as per boq enclosed with nit document including supply installation testing and commissioning of panels, supply, installation, testing and commissioning of approved make direct expansion (dx) type cooling coil unit for air handling unit (ahu) as per boq/ specifications enclosed with nit document, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 3.2 tr, supply and itc of sheet metal sectionalised construction double skin ahu for vrf/vrv system as per boq/ specifications enclosed with nit document, supply and itc of ahu kit, refrigerent gas - supply and top-up of refrigerent gas r410a., control cable - supply, installation, testing & commissioining of control cum transmission cabling between odu & idu 2c x 1.0 sqmm cu cable in rigid pvc conduit duly supported., drain piping - supply, installation and commissioning of upvc drain piping with 6/9 mm thick closed cell nitrile rubber insulation with all fittings, solvent, necessary accessories and supports. thermal insulation sleeve joints shall be sealed with black tape - 25 mm/32 mm, supply, installation, balancing and commissioning of factory/hand fabricated aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required - thickness 0.8 mm, supplying and fixing of following thickness open cell acoustic nitrile rubber insulation on existing duct after applying suitable adhesive for nitrile rubber. as per specifications and as required - thickness 10mm., supply, installation,testing, & commissioning of variable friquency drive, supply,installation,testing & commissioning of strip heater along with controller, supply of power distribution panel ac distribution panel board - ip65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, without mcbs etc. as required to be made of customised requirment for outdoor fixing., supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 16 sqmm, supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 35 sqmm

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15781582
Location : bangalore , karnataka
Source : GEM Tenders
tender for supply installation testing and comissioning of vrf , supply installation testing and comissioning of indoor unit , supply installation testing and comissioning of joints , supply of cables , supply installation testing and comissioning of switch boxes , supply installation testing and comissioning of copper pipes , drain pipe , refrigerant , material shifting , supply installation of cable tray , core cutting , s i of distribution box , laying of cable , termination of cable , dismantelling , pop gypsum work, casset ac installation for rtamc, supplying, installation, testing & commissioning of variable refrigerant flow/variable refrigerant volume air cooled outdoor units alongwith outdoor stand as per ts for cooling --10hp, supplying, installation, testing and commissioning of following minimum capacity 4 way cassette type indoor ceiling mounted unit including wireless remote as per ts (make will be same as of outdoor)--3.2 tr, supplying, installation, testing and commissioning of y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supply of 3c x 2.5sqmm flexible cable for idu power, supplying, installation, testing and commissioning of 5amps switch box (5a switch+5a socket on 3 module box), supply of 4c x 16sqmm pvc/xlpe armoured copper cable, supply & installation/laying of copper pipe for refrigerant with insulation and support etc., as required, supply & laying of 2 core 1.0-1.5 sqmm communication cable between idu and odu inside rigid/flexible pvc conduit wherever required, supply & fixing cpvc drain pipe 25/32mm with supports as per site conditions, supply and topping up refrigerant r410a/r32 as applicable (if required), lifting & shifting of 01 nos odu with crane/manually to site as per direction of eic with complete safety, supply & installation/laying of 100/200mm cable tray with closure as per site conditions with complete safety, core cutting works as per site condition, supply and installation of ip-65/66 stainless steel (304 grade) or powder-coated galvanized steel outdoor distribution box of appropriate size (should be spacious) near odu with 63a - 2 nos mcb and accessories (ie lugs cable tie wires screws bn etc), laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade offollowing size in the existing masonry open/close duct as required.-upto 35 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. -upto 35 sq. mm (clamped with 1mm thick saddle), supplying and making end termination with brass/aluminium compression gland and copper lugs for following size of pvc insulated and pvc sheathed / xlpe copper conductor cable of 1.1 kv grade as required.--4 x 16 sq. mm (28mm), service charges for dismantling handing over of an existing cassette idu(samsung make) - 1.2 or 1.3tr(pump down pressure testing refilling of gas), dismantling/cutting out of existing pop/gypsum ceiling and shifting the debris outside powergrid campus, supply and installation of pop/gypsum work includes gypsum board, pop powder, putty and paint etc., (for making ceiling as per its earlier form)
T18 Ref No : 16139514
Location : kamrup , assam
Source : GEM Tenders
tender for odu 1 , odu 2 , 4-way cassette unit 1 , 4-way cassette unit 2 , y joints 1 , y joints 2 , cu piping , damper , actuator , nitrile rubber , wiring , mccb , mcb db 1 , mcb db 2 , mcb , allied electrical works , dx coil unit , 4-way cassette unit 3 , ahu , ahu kit , ref gas , control cable , drain pipe , ducting , acoustic nitrile rubber , vfd , strip heater , pdp , al cable 1 , al cable 2, supply installation testing and commissioning of vrf based air conditioning system, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 14 hp, supply and itc of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin rotary/scroll compressor(s), minimum two compressors (with individual seperate pcb) for above 6 hp modules/non module, microprocessor based controller, top discharge type condensing unit(s), with r-410-a refrigerant or equivalent, vibration isolators with suitable foundation etc. complete as required, as per nit specifications - 10 hp, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.56 tr, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 2.0 tr, supplying, installation, testing and commissioning of odu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, supplying, installation, testing and commissioning of idu y/t/multi joints. joints shall be of same original equipment manufacturer (oem) make as of odus and idus, refrigerant piping for vrf system - supply , installation , testing and commissioning of copper piping in brazed construciton, complete with nitrile rubber insulation, supports/suspenders, as per enclosed specifications. refrigerant piping for suction gas with 19mm thick nitrile insulation & refrigerant piping for liquid gas with 13mm thick nitrile insulation (various capacities as per boq of nit document, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - damper, supply, installation, testing and commissioning of motorized (on-off type) duct mounted gi volume control damper with enthalpy sensor and necessary control wire for integration within ahu room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to smacna/is and as per specifications complete etc. as required - actuator, supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (class-o) insulation on existing duct as per nit specifications - 25mm, wiring for circuit/ submain wiring along with earth wire as per nit specifications, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board as per nit specifications, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing following way, tpn, sheet steel, mcb distribution board, 240 v, on surface/ recess as per nit specifications, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka mcbs as per boq enclosed with nit document, allied electrical works as per as per boq enclosed with nit document including supply installation testing and commissioning of panels, supply, installation, testing and commissioning of approved make direct expansion (dx) type cooling coil unit for air handling unit (ahu) as per boq/ specifications enclosed with nit document, supply and itc of following minimum capacity 4 way cassette type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with dx copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc as per nit specifications - 3.2 tr, supply and itc of sheet metal sectionalised construction double skin ahu for vrf/vrv system as per boq/ specifications enclosed with nit document, supply and itc of ahu kit, refrigerent gas - supply and top-up of refrigerent gas r410a., control cable - supply, installation, testing & commissioining of control cum transmission cabling between odu & idu 2c x 1.0 sqmm cu cable in rigid pvc conduit duly supported., drain piping - supply, installation and commissioning of upvc drain piping with 6/9 mm thick closed cell nitrile rubber insulation with all fittings, solvent, necessary accessories and supports. thermal insulation sleeve joints shall be sealed with black tape - 25 mm/32 mm, supply, installation, balancing and commissioning of factory/hand fabricated aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required - thickness 0.8 mm, supplying and fixing of following thickness open cell acoustic nitrile rubber insulation on existing duct after applying suitable adhesive for nitrile rubber. as per specifications and as required - thickness 10mm., supply, installation,testing, & commissioning of variable friquency drive, supply,installation,testing & commissioning of strip heater along with controller, supply of power distribution panel ac distribution panel board - ip65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, without mcbs etc. as required to be made of customised requirment for outdoor fixing., supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 16 sqmm, supply of lt armoured aluminium cable (1.1kv) as per boq/ specifications enclosed with the nit document - 35 sqmm
T18 Ref No : 16838602
Location : kolkata , west bengal
Source : GEM Tenders
tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0 tr hi- wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , supply installation testing and commissioning of 3.0tr cassette type split systems , copper refrigerant piping for 1.5tr and 2.0tr hi-wall split ac , copper refrigerant piping for 2.0tr and 3.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr and 2.0 tr hi-wall split ac , outdoor stand for 2.0tr and 3.0 tr cassette type split units , 4 inch dia pvc pipe , supply and laying of suitable flexible cable from outdoor to indoor , dismantling of old air conditioning, supply installation testing and commissioning of air conditioner, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating,isser value minimum value 5.6, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, isser value minimum value 5.6 ., supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , isser value minimum value 5.6 ., supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is 1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required.inverter type cooling with 5 star bee rating, isser value minimum value 5.6 ., supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supply ,installation of minimum 4 inch dia heavy duty pvc pipe with all hanging supports required at regular intervals for laying copper and drain piping in banking, supply and fixing of four core cable, dismantling of existing air conditioner

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Refrigerant R410a. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Refrigerant R410a sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Refrigerant R410a Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Refrigerant R410a, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Refrigerant R410a Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Refrigerant R410a Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Refrigerant R410a.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Refrigerant R410a depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Refrigerant R410a Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Refrigerant R410a bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Refrigerant R410a. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Refrigerant R410a, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Refrigerant R410a, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Refrigerant R410a?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Refrigerant R410a tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Refrigerant R410a?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Refrigerant R410a, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Refrigerant R410a is declared L1 and is generally awarded the contract