tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989

Latest Tender Detail from state bank of india SBI for the tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989 in kolkata, west bengal,. Reference number 16813309. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

Description :
total quantity = 574 ----- document required from seller = experience criteria,past performance,bidder turnover,oem authorization certificate,oem annual turnover,compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation
T18 Ref No.
16813309
Tender ID
GEM/2026/B/7924724
Tender Value
25.36L
Tender EMD
21.5K
Tender Fee
Refer Document
Published Date
Aug 17, 2026
Due Date
Aug 27, 2026
Tender Opening Date
Aug 27, 2026
Description :
total quantity = 574 ----- document required from seller = experience criteria,past performance,bidder turnover,oem authorization certificate,oem annual turnover,compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation

Get Complete Tender Documents to Participate

Tender NoticeBOQEligibilityEMD DetailsImportant Dates
We take all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Browse GeM Portal Tenders

This Government Tender has been Published  by State Bank Of India SBI for work related to automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac in Kolkata, West Bengal. The Tender work is tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like State Bank Of India SBI usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Kolkata , West Bengal tender on a single page. Businesses involved in automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989 from Kolkata, West Bengal may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by State Bank Of India SBI in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for supply installation testing and commissioning of 1.5 tr hi-wall split systems , supply installation testing and commissioning of 2.0tr cassette type split systems , copper refrigerant piping for 1.5tr hi-wall split ac , copper refrigerant piping for 2.0tr cassette type split units , drain pipe , outdoor stand for 1.5tr hi-wall split ac , outdoor stand for 2.0tr cassette type split units , voltage stabilizer for 1.5 tr split systems , voltage stabilizer for 2.0 tr cassette systems, supply installation testing and commissioning of hiwall and cassette air condition systems, supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete withindoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr(idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotarycompressor. the system shall be able to deliver 100% of the rated capacity upto 42 degree c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730,hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is - 1391 part ii 2023. the system shall be able to operate up to 50 degree c (out door ambient temperature). inverter type cooling with 5 star bee rating, minimum value of iseer 5.6, supplying, installation, testing and commissioning of air cooled cassette type air conditioners complete with indoor unit(idu), out door unit (odu), r-32/r410a/r-407 green refrigerant, wireless remote, inbuilt drain pump, suitable for 400/230v, 50 hz ,1 /3 phase ac supply, including surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 mtr (idu to odu), copper power and control cable upto 5.5 mtr (idu to odu) including drain pipe, the system shall be capable of performing cooling,dehumidification, air circulation, filteration & ventilation of following capacity with scroll/rotary compressor with min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb) as specified. the system shall be able to deliver 100% of the rated capacity as per relevant is code. the lab testing reports as per is -1391 shall be submitted from national accreditation board for testing and calibration laboratories (nabl) accredited as per international electrotechnical commission (iec) 17025 standards/central power research institute (cpri)/ electrical research and development association (erda)with original equipment manufacturer (oem) etc. complete as per cpwd specification and as per is 1391 as required. inverter type cooling with 5 star bee rating , minimum value of iseer 5.6, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, along with electrical flexible copper 4core cable all accessoriesas per specifications etc. as required 6.4 mm dia (od) (soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 1.5 tr hi - wall split, supplying, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines,along with electrical flexible copper 4core with all accessoriesas per specifications etc. as required 9.5 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (od) (soft drawn) with tube thickness 1.2 mm for 2.0 tr cassette type split units, supply and fixing of duly insulated 25mm upvc drain pipe, supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 tr hi-wall split ac., supplying , installation, testing and commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 tr cassette type split units., supplying, installation, testing and commissioning of stabliser with rated 4kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989, supplying, installation, testing and commissioning of stabliser with rated 5kva,input voltage range 130-260 voltage ,output voltgae range 195-245 voltage ,metalic encloser,100% copper winding,wall mounting type,digital type voltmeter,class b type insulation temperature and furnish all test report and certificate.the product with minimum 2 yrs of warranty,automatic line voltage correctors (step type) as per is-8448 1989 issued by State Bank Of India SBI for automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac related work in Kolkata, West Bengal? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac parameters and guide you on how to coordinate efficiently with the procurement team of State Bank Of India SBI

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989 . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by State Bank Of India SBI.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989 in West Bengal.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Kolkata.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by State Bank Of India SBI

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac contracts, companies must prepare their core compliance documents. Vendors operating across West Bengal must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality automatic line voltage correctors,calibration laboratories,printed circuit board,hermetic compressor,voltage stabilizer,rotary compressor,air conditioners,electrical cable,remote control,heat exchanger,air condition,control cable,power cable,lab testing,development,drain pipe,drain pump,split ac solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Kolkata region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989 by State Bank Of India SBI

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989 within the West Bengal jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for Tender For Supply Installation Testing And Commissioning Of 1.5 Tr Hi-wall Split Systems , Supply Installation Testing And Commissioning Of 2.0tr Cassette Type Split Systems , Copper Refrigerant Piping For 1.5tr Hi-wall Split Ac , Copper Refrigerant Piping For 2.0tr Cassette Type Split Units , Drain Pipe , Outdoor Stand For 1.5tr Hi-wall Split Ac , Outdoor Stand For 2.0tr Cassette Type Split Units , Voltage Stabilizer For 1.5 Tr Split Systems , Voltage Stabilizer For 2.0 Tr Cassette Systems, Supply Installation Testing And Commissioning Of Hiwall And Cassette Air Condition Systems, Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(idu), Out Door Unit (odu), Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(idu To Odu), Copper Power Cable Upto 3.5 Mtr (idu To Odu) I/c Drain Pipe R-32/r-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260v With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/international Electrotechnical Commission (iec) 60730,hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(idu), Out Door Unit (odu), R-32/r410a/r-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230v, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (idu To Odu), Copper Power And Control Cable Upto 5.5 Mtr (idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/rotary Compressor With Min 5 Year Original Equipment Manufacturer (oem) Warranty Both Compressor And Printed Circuit Board (pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (nabl) Accredited As Per International Electrotechnical Commission (iec) 17025 Standards/central Power Research Institute (cpri)/ Electrical Research And Development Association (erda)with Original Equipment Manufacturer (oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Minimum Value Of Iseer 5.6, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, Along With Electrical Flexible Copper 4core Cable All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split, Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/brazing Including Accessories, Insulated With Xple Class-o Tubular Insulation/with Class-o Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines,along With Electrical Flexible Copper 4core With All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (od) (soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units, Supply And Fixing Of Duly Insulated 25mm Upvc Drain Pipe, Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-wall Split Ac., Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units., Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 4kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989, Supplying, Installation, Testing And Commissioning Of Stabliser With Rated 5kva,input Voltage Range 130-260 Voltage ,output Voltgae Range 195-245 Voltage ,metalic Encloser,100% Copper Winding,wall Mounting Type,digital Type Voltmeter,class B Type Insulation Temperature And Furnish All Test Report And Certificate.the Product With Minimum 2 Yrs Of Warranty,automatic Line Voltage Correctors (step Type) As Per Is-8448 1989 are available inside the detailed notification files. Bidders planning to target this contract in Kolkata should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Get Expert Tender Bidding Support

Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.

Call Our Expert: +91 7069661818
Your Information Is 100% Secure & Confidential