Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

10Results forPetrol pump service Tenders List

Latest Petrol pump service Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Petrol pump service tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Petrol pump service tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Petrol pump service Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Petrol pump service tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Petrol pump service Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Petrol pump service Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Petrol pump service Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Petrol pump service tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Petrol pump service Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Petrol pump service sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Petrol pump service tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Petrol pump service tenders.

Is EMD mandatory for all Petrol pump service tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Petrol pump service work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Petrol pump service tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Petrol pump service Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15875280
live Tender
Location : ajmer , rajasthan
Source : GEM Tenders
live Tender

tender for transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , transportation charges up to 50 km for alternator up to 55 kva , transportation charges more than 51 to 100 km for alternator up to 55 kva , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , rewinding of main stator winding of alternator more than 20 kva and upto 55 kva , rewinding of main rotor winding of alternator more than 20 kva and upto 55 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of power diode for rotating rectifier assembly , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mm direct in ground , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 2 x 10 sq. mm 19 mm , supply and making end termination for 4 x 16 sq. mm 28 mm , providing and fixing 6 swg dia g.i. wire , supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors ,, rc for repairing servicing shifting of dea sets at hub sites under ba udaipur, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter chain in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of techo drive unit in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), supplying & fixing of 12 volt battery charging alternator on the existing dg set i/c making connections testing etc. complete as reqd. ( make -autolek or similar superior make), repairing and servicing of the 12 volt battery charging alternator for dg set i/c greasing, oiling, making connections testing etc. complete as reqd., repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., dismentalling of existing up to 20 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., dismentalling of existing more than 20 kva & upto 55 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., extra for shifting of existing dea set up to 20 kva capacity from rooftop of the building to ground floor / loading vehicle with the help of chain pulley / crane by ensuring safety to the existing construction at site and reparing of any damage during shifting / dismentling by making good the same etc. complete as reqd., loading of existing up to 20 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., loading of existing more than 20 kva & upto 55 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., transportation of up to 20 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., transportation of more than 20 kva & upto 55 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., unloading of existing dea sets of up to 20 kva dea sets from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., unloading of existing dea sets of more than 20 kva & upto 55 kva dea from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., installation, testing and commissioning of existing dea sets of up to 20 kva dea sets on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., installation, testing and commissioning of existing dea sets of more than 20 kva & upto 55 kva dea on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., repairing of up to 20 kva dea sets crank shaft i/c grinding, lapping, bushing, allignement etc complete as reqd., transportation charges up to 50 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., transportation charges more than 51 to 100 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main stator winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of power diode for rotating rectifier assembly for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq. mm (19 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required., supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.


Tender Value : 0
Due Date : Jun 29, 2026
T18 Ref No : 15875281
live Tender
Location : ajmer , rajasthan
Source : GEM Tenders
live Tender

tender for visit charges to attend fault of dea set , general servicing of the up to 20 kva dea sets , general servicing of more than 20 kva and upto 32.5 kva dea sets , general servicing of more than 32.5 kva and up to 55 kva dea sets , replacement of diesel filter element set 1 ltr , replacement of oil filter element 1 by 2 ltr , replacement of oil filter element 1 ltr , replacement of diesel filter element set 1 by 2 ltr , replacement of oil filter set suitable for ea set of 50 to 55 kva , replacement of lubricating oil multi grade 20w40 , replacement of steel wire braided fuel pipe line , replacement of stop solenoid 12 volt , replacement of starting key with switch , replacement of battery leads red and black , replacement of coolant for radiator of superior quality , replacement of v belt , replacement of hose pipe set with clips , replacement of fuel feed pump assembly , replacement of solid state smps or scr based battery chargers , replacement of push button switch for start or stop or reset , replacement of 12 v dc or 220 v ac hr meter counter type , supply and fixing of 12 volt battery operated self starter , repairing and general servicing of the existing faulty radiator up to 55 kva , pdg general servicing and repairing of 12 volts engine starting self , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , transportation charges for alternator of various capacity up to 55 kva up to 50km , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 4 x 16 sq. mm 28 mm , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors , supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery, rc for repairing servicing of various capacity dea sets at hub sites under ba ajmer, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., transportation charges for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismantling, loading, unloading, transportation, safe handling & i/c reinstallation, making connections, power and control cable connections etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd up to 50km., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.


Tender Value : 0
Due Date : Jun 29, 2026
T18 Ref No : 15072929
Location : etah , uttar pradesh
Source : GEM Tenders

tender for boq cisf 0707 floating pump , 0707 high expansion foam generator , 0707 aluminium fire suit , 0707 suction hose 100mm , 0707 smoke blower cum exhauster. , 0707stretcher , 0707lifebuoy , 0707life jacket , 0707 celling hook , 0707fire beater , 0707ejector pump , 0707 hydraulic ram , 0707hydraulic cutter , 0707hydraulic spreader , 0707 medium expansion generator , 0706 co2 fire extinguisher 4.5kg , 0706 co2 fire extinguisher 6.5kg , 0706 dcpfire extin. cartridg type-06 kg , 0706 dcpfire extin. cartridg type-09 kg , 0707 branch london type, boq cisf, 0707 floating pump specification--pump and engine specification casing-powder coated anodized aluminum as per is 617 impeller -bronze impeller 3. engine specification. engine shall meet applicable environmental norms and emission standard of govt. of india. 4 stroke air cooled petrol engine power output -not less than 5.9 hp ignition system -transistorized magneto starting system-recoil type of pump -single suction, centrifugal outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float controlled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped with fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam. 23outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float controlled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped with fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam, 0707 high expansion foam generator specification - high expansion foam generator shall driven by water pressure and used for coverage for large spill of hydrocarbon liquids,total flooding of voluminous enclosure such as cable ducts and in accessible locations. it should be light weight, compact, suitable for groundoperation and easy movement. it should have arrangement for smoke extraction also. it should have pressure gauge of suitable rating at inlet for measuring pressure of water flow. a carrying handles and wheels should be provided for easy and smooth carriage.body -ss or frp materials to be specified by indentor 2. nozzle -gun metal 3. foam screen -ss 4. piping and foam inductor -light weight material with anti corrosive treatment 5. fan -fibre reinforced plastic - frp-or ss-material to be specified by indentor- 6. coupling -gun metal 7. foam duct -nylon or polythene - material to be specified by indentor- 6.0 dimension of the body - shell-and attachment- 1. depth -450 - 500 mm 2. width -900- 950 mm 3. height -900- 1000 mm 4. foam duct -10 meter long 5. smoke duct -10 meter long 6. coupling diameter -63 mm - instantaneous type- 7. maximum unit weight -50 kg, 0707 aluminium fire suit specification - the suit shall allow the wearer to expose himself and withstand point source approximately at 900 degc for 4-5 minutes, 700 degc for 15 minutes and 500 degc for 5 hours without adversely affecting the wearer .the fabrication of fire proximity or approach suit shall be made out of non-flammable, light weight, non-toxic flexible and heat reflecting material. the fabric shall be of impermeable aluminized coated oxidized penotex carbon fiber and shall have thermal insulation lining capable of resisting high temperature not less than 900 degc.max.wt-9.0 kg., 0707 suction hose 100mm specification - suction hose synthetic of 100 mm internal dia and length 2.5 mtr. confirming to is 3549 latest revision. it must be fully wire embedded suction hose, which can be used from suction side of the pump from source to pump in-let. the suction hose mostly binded with copper wire with isi marked male and female threaded coupling as per is 902 - latest revision-and shall have 04 lugs. the hose shall be subjected to an internal hydraulic pressure of 8 kg or cm2 for a period of three minutes and there shall be no sign of leakage or failure. the working vacuum shall be down to 635 mm of mercury without collapse. coupling must be tested for hydraulic pressure test at 21 kg or cm2 for a period of 02 minutes. the suction hose must be protected against oil, fungus, chemicals, acid and alkalis., 0707 smoke blower cum exhauster. specification - it should be portable, high output smoke exhauster, petrol driven engine - 5.5 hp-and should be of size 18 inch or above. 2. it should be able to provide both positive and negative pressure ventilation to serve dual application i.e. as a blower as well as suction for clearance of smoke or gases even in confined or closed non ventilated areas 3. the exhauster should be compact in dimension or size and should not measure more than 20 - height-x 20 - width-x 15 - depth-with a tolerance of + or -10 percent so that it can be easily placed in the fire tender compartment if so required. 4. the exhauster unit should be light in weight and weigh less than 35 kg with a tolerance of + or - 10 percent . 5. the exhauster should have high output airflow for effective de smoking operations. 6. the fan size should be 18 diameter with many turbo blades to generate strong air force. 7. the dimensions should not exceed 18 inch in depth, 24 inch in width and 24 inch in height blade - - 18 diameter assembly should made up of aluminium or air flex fiberglass reinforced polyamide blades frame - - it should formed and welded sheet metal construction with powder -coat finish. grille - - should continuous circular wound external -weld steel wire with 4 tie points for additional safety - steel is zinc-plated with a clear chromate finish, 0707stretcher specification - stretcher sl parameters value 1. unfolded size of the stretcher - l x w x h -not less than 201 x 53 x 13 - cm-with tolerance of +- 2 mm 2. number of folds which can be made not less than 02 3. material of the stretcher frame aluminium or powder coated mild steel 4. material of the support bed of the foldable stretcher vinyl coated nylon fabric or tetron canvas 5. the foldable stretcher shall fold lengthwise and cross wise and shall fold flat for compact storage and asy transportation yes 6. support bed of the foldable stretcher shall be stain and water resistant and easy to clean and antifungal yes 7. foldable stretcher shall have aluminium feet to prevent stretcher bed from touching the floor yes 8. aluminium poles shall have rubber hand grips to keep a firm grasp on the stretcher yes 9. minimum load carrying capacity of the foldable stretcher no less than 160 kg 10. weight of the foldable stretcher not more than 20 kg 11. foldable stretcher should have patient restrain strap with double locking quick release safety buckets yes 12. vertical hoisting sling to be provided yes, 0707lifebuoy specification - 2. technical requirement- - a-the lifebuoy shall be irs approved. - b-lifebuoy shall be made up of, high visibility, impact resistant orange pe material filled with high density soft polyurethane - pu-foam which gives high floatability. - c-lifebuoy shall be provided with a grab line attached at four equally spaced points. - d-lifebuoy shall have solas retro- reflective tape stuck at four equally spaced places. - e-lifebuoy should be suitable for major application is rescue during floods and sea mishaps. - f-lifebuoy should have od 71 +- 1 cms,id 45 +- 1 cms. - g-lifebuoy should have buoyancy more than 17 kg. - h-lifebuoy shall be moisture proof and non-inflammable. 3. approvals- - a-lifebuoy shall be irs approved. - b-lifebuoy shall conforms to solas 74 as amended reg. iii or 4,iii or 7.1,iii or 34,x or 3 lsa code reg. i or 1.2 and ii or 2.1.1 imo resolution msc.81 - 70 - , msc. 200 - 80 - , msc.97 - 73-8.1,8.3., 0707life jacket specification - technical requirement- - a-it shall be made up of high visibility nylon orange coloured cloth filled with high density soft polyethylene foam to provide high floatability. - b-jacket shall be provided with suitable plastic quick lock buckle and velcro for tightening. - c-irs approved water activated life jacket light should be provided with life jacket. - d-whistle shall be attached with jacket and solas approved retro- reflective tape stitched at visible locations covering a total area not less than 400cm. - e-it shall be suitable for major application is floods and sea or river mishaps. - f-life jacket shall have size not less than 68 x 42 x 10 cm. - g-floatability shall not be less than 16.5kgs. - h-weight of jacket shall not be more than 750gms - + or -100gm - ., 0707 celling hook specification - specification of fire hook standard is 927 - 2008 the function of fire hook is to pierce celling to allow the water on the upper floor to drain away, to pull down thatched roofs or roofs made out of matting, pulling out bales and bags of various commodities from a distance,opening and closing down of doors and various similar jobs technical features - material shall steel to be used for hook conform is 2004 - 1978 - handle shall be made of bamboo of length not less than 3 m - the edges shall be well shaped and finished - forgings shall be free from seams ,burrs cracks and other surface defect - hook shall be treated with suitable anti corrosive paint - hook shall be engaged to horizontal bar and weight of 140kg shall be applied vertically to the handle .the test hall be repeated ten times .the hook shall not bend and or or dent during the test. - standard is 927 - 2008 marking each hook shall be cleary and permanently marked with the following information - manufacturer s name or trade mark - size of handle - year of manufacture - marked with standard mark note - the equipment should be procured from the manufacturers - manufacturer needs to have all test or evaluation facility in house failing which the test evaluation should got done from govt. lab or govt. approved nabl accredited lab only - pre dispatch inspection-pdi clause is mandatory and to be incorporated at the time of indent of above fire equipment. the cisf representative for inspection or pdi shall be detailed by fire directorate new delhi, standard is 8096 - 1992 fire beaters are often used for putting off small fires such as wild grass, shrubs, dry vegetation, hay, plastic, coal which can be easily put out by beating and smothering. this piece of equipment finds much application in rural areas and in those places where there is a scarcity of water components 1. handle - i-the handle shall be made of solid bamboo having 1800 mm length and 30 + 5 mm diameter or of some alternative material of heat insulate properties provided. the handle shall be finished smooth. - ii-the handle before fitting into the socket made in shank shall be liberally swabbed with termite resistant composition comprising 10 percent solution of acid-chromate composition in water. it will then be allowed to dry for at least 24 hours. - iii-the free end of the bamboo handle shall be protected from disintegrating by fitting with a hollow close ended cap made of chrome plated mild steel or aluminium. the protective cap shall have knurling made on its outer surface to enhance grip at least 5 mm of the round edges of this knurled protective cap shall be chamfered all round at 45 degree to reduce sharpness 2. blade the blade of the fire beater shall consist of a rectangular piece of expanded mild steel or steel or steel wire mesh measuring 452 mm x 352 mm, covered fully on both sides with stretched fire resistant canvas olive green in colour placed between two frames and securely fixed in position with hexagonal nut-bolts using spring washers all-round the frame the two pieces frame shall be made of 1 mm thick mild steel. the width of frame shall be 30 mm. the shank portion of the blade shall also be in two pieces made of 1 mm thick spring steel. the frame shall be welded at diagonals as per is 819-1957 assembling the blade so made shall be fixed with bamboo handle through a two piece shank. the socket part of the shank shall be tightly screwed to the bamboo handle by two bolts, nu, 0707ejector pump specification - specification 1. material of construction -aluminium alloy 2. maximum working pressure -10kg or cm2 3. minimum working pressure -5kg or cm2 4. test pressure -21kg or cm2 5. inlet diameter -100 mm - is - 902 - , male round threaded 6. outlet diameter -100 mm - is - 902 - , male round threaded 7. inst. inlet -63 mm - is - 903-instantaneous male 8. discharge -650lpm at 7kg or cm2 9. max suction depth -10 meters, 0707 hydraulic ram specification - 4. hydraulic spreader sl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent -3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707hydraulic cutter specification - technical specification or data -- hydraulic cutter should have the following specifications. a cutting force upto not less than 690 kn b capable of cutting round bar not less than 40mm dia steel rod of 500 550 mpa strength c blade opening at tips not less than 200 mm. d weight not more than 20 kg accessories -- 01. tool kit for changing curved and straight blades with spare blade. 02. connecting hoses of at least 5 meter for connecting pumps. 03. compatible pumps to achieve above mention performance of equipments., 0707hydraulic spreader specification - sl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent- 3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707 medium expansion generator specification - foam expansion ration within the range of 1 - 300 to 1 - 600.foam output lpm-100-150 m3 or min weight-weight within the range of 20 kg to 25 kg inlet water pressure - bar-- 8 to 10 smoke exhauster-100-120 m3 or min at 08 to 10 bar inlet pressure material of construction-body or shell -s.s - 304 grade - , nozzle-g.m, foam screen-knitted fabric or s.s, fan - ,alloy aluminum, turbine-g.m., foam duct - 30 m long-- polythene, carrying handle and stand-s.s, smoke trunk-7.5 mtrs. long special construction., as per is 15683 - 2018 -with latest amendments - 1. type of extinguisher isi marked stored pressure type co2 4.5 kg capacity fire extinguisher, conforming to is 15683 - 2018 -with latest amendments - .2. extinguishing media carbon dioxide based - as per is 15222 - 3. expelling medium co2 extinguishing medium. 4. type of extinguisher high pressure extinguisher - service pressure greater than 19 bar- 5. feature of fire extinguishers yes, safety devices - mandatory for high pressure extinguisher - , rechargeable andcarrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is 15683-2018. 6. class of fire for which fire extinguisher is suitable. class-b and c 7. minimum effective discharge time-minimum 8 sec - as per 7.2.2 of is 15683 - 2018- 8. material specification for the body of highpressure extinguisher- steel body - as per latest is 7285- 9. carbon dioxide based fire extinguisher capacity in kg. 4.5 kgs. 10. operating temperature temperature range as mentioned in clause no.7.1of is 15683 - 2018. 11. fire ratings of different class of fires-minimum 34b - higher acceptable- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory. additional technical parameters- 1. marking required as per clause 10.2 of is 15683 - 2018 2. valve high pressure control valve as per is-3224 bearing isi mark and peso - ccoe - , nagpur approved. 3. test report and peso or bis certificate- a-test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. b-peso - formerly ccoe - , nagpur approval certific, 0706 co2 fire extinguisher 6.5kg specification - specification for co2 6.5 kg capacity fire extinguisher - trolley mounted- isi marked 6.5kg capacity co2 trolley mounted portable fire extinguisher confirming to is - 16018-2012 having typical shape, showing the cylinder, concave base shall be completed with following -- technical data 1. temperature working range shall be -300 c to +550 c 2. co2 fire extinguisher should be as per is-16018 - latest revision - . with isi mark. 3. filled carbon dioxide gas shall be as per is-15222 - latest revision - . 4. extinguisher should be provided with ms trolley with solid rubber wheels, handle, control discharge m e c h a n i s m with discharge hose, rubber grip, hanging clamp and n o n metallic discharge horn. 5. the minimum bursting pressure of discharge hose - wire braided-shall be 275 bar. 6. extinguisher should be class b, c and electrical fires, fire rating 55b. 7. seamless cylinder should be as per is 7285 - latest revision-with isi mark and should be approved by peso. 8. discharge valve should be wheel type as per is 3224 - latest revision-with isi mark. 9. safety device should be as per is 5903 and safety device conforming to is-5903 - latest revision-shall be in-built in discharge valve conforming to is-3224. 10. siphon tube should be of brass alloy no. 2 as per is 407. 11. finishing of paint shall be with po red as per is-5 - shade 538- 12. inspection and testing of the extinguisher shall be as per approved qap, fire extinguisher, as per is 15683 - 2018 -with latest amendments - 1. type-cartridge type with 01 spare cartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is -1568 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher shall be painted withp.o. red color conforming to shade no. 536 or, fire extinguisher, as per is 15683 - 2018 -with latest amendments- 1. type-cartridge type with 01 spare cartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure- 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is - 15683 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters- 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher s, 0707 branch london type specification - multipurpose nozzle 500 lpm 1. technical requirements- - a-flow rate - selectable-- 150-250-350-500 lpm. - b-light in weight and easy to handle. - c-weight of the nozzle - 2.5 kg. - d-the calibrated flow rates are easily selectable through an indexed ring and the maximum rate is indicated by a raised lug. - e-the stream patterns are also changed by rotating the diffuser head ring with tactile marking - straight jet, spray and fog - . - f-nozzle should have flush feature for flushing any foreign items like wood or stone etc. - g-nozzle should also have metal partitions inside to restrict entry of foreign particle of bigger size. - h-nozzle should be having pistol grip, shut off ball valve opening and made of aluminium alloy. - i-nozzle shall meet the operational requirement as per en standard. - j-the head is protected with polyurethane bumper guard. the elastomers of bumper guard does not melt under heat. the teeth of nozzle should be of steel. - k-it should be of pok or elkhart or akron or rosenbaur make. - l-nozzle should have 3 stream pattern - straight jet, flash over and wide angle fog- - m-fog angle should be 130 degree. - n-inlet of the nozzle should of swivel inlet to avoid any kinking of hose 2. warranty-warranty - 1 years. service warranty - 5 years 3. pre dispatch inspection- - a-pre dispatch inspection shall be carried out at vendor s or oem site where all testing facilities as per relevant standard are available.


Tender Value : 3614370.28
Due Date : May 02, 2026
T18 Ref No : 15289539
Source : GEM Tenders

tender for soq1 , soq2 , soq3 , soq4 , soq5 , soq6 , soq7 , soq8 , soq9 , soq10 , soq11 , soq12 , soq13 , soq14 , soq15 , soq16 , soq17 , soq18 , soq19 , soq20 , soq21 , soq22 , soq23 , soq24 , soq25 , soq26 , soq27 , soq28, armo of e and m installation at kushinagar international airport kushinagar for one year, periodical maintenance and operation of electrical and mechanical installations involving operation, repairs and maintenance, attending to complaints/faults/ breakdowns and taking rectification action, ensuring serviceability/satisfactory working condition of the systems, carrying-out preventive maintenance, maintenance of records/ documents etc. under this contract on all working days including saturdays, sundays and holidays as per tender specifications, terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (special repair supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement., carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai., servicing of l&t make, model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts, releases etc, checking the hardware for wear & tear, checking of termination & tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope), regreasing of the acb parts as recommended by oem, refixing the acb, testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head., one time servicing, maintenance, testing, overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv, 630 a, 21ka/3sec, 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p, 630a, drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering, relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer, rmu, ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete., carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine, di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil., supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement., one time servicing, maintenance, testing, overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv, 630 a, 21ka/3sec, 3way non extensible sf6 insulated rmucomprising of 02 nos. 630a manual load breaker switch and 01 no. 630a manual vacuum circuit breaker. transformer - 11kv/0.433kv , 630 kva dry type transformer -01 nos lv componenet - 4p, 1250a, drawout acb-01 nos, 4p 630 a mccb-02 nos. & 3p 400 a mccb-01 nos. capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering, relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer, rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete., decoration of terminal building and atc cum admin building with decorative lights on the occasion of independence day, republic day and any other occasions as decided by eic for 04 days on each occasion on hiring (rental) basis with following type of lights and decoration accessories with provision for operation as per national flag theme (tricolour)/ occasion themes for indoor & outdoor use, including supply and installation of lights on selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. a) minimum 450 nos. led series riser pixel light bright (each riser of approx. 30 feet. length) (tri- colour pattern) b) minimum 30 nos. outdoor led focus/spot light for illumination of pillars/glazing etc. note - the installation & testing of lighting systems and decoration accessories shall be completed by 0500 pm, 02 day prior to the occasion., providing and installations of decoraed themed selfie points along with focus lights on the occasion of independence day, republic day and any other occasions as decided by eic for 03 days on each occasion on hiring (rental) basis with following type of decoration accessories (selfie point) with provision for operation as per national flag theme (tricolour)/ occassion themes for indoor use, including supply and installation of selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. selfie point strength and material should be sufficient enough to sustain it for required days. (a) selfie point having inscription of the occasion as decided by e.i.c. of minimum size 7 x 5 x 5 feet including provision of 02 nos led focus light to focus it. note - 1. the installation & fixing of selfie points shall be completed by 0500 pm, one day prior to the occasion. 2. one location comprising selfie point etc. shall be measured as qty-1 each, decoration of terminal & atc cum admin building with decorative lights on the occasion of christmas day & newyear for 10 days on hiring (rental) basis with following type of lights and decoration accessories with provision for operation for indoor & outdoor use, including supply and installation of lights with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. a) minimum 450 nos. led series riser pixel light bright (each riser of approx. 30 feet. length) b) minimum 30 nos. outdoor led focus/spot light for illumination of pillars/glazing etc. note - the installation & testing of lighting systems and decoration accessories shall be completed by 0500 pm, 02 day prior to the occasion. (pattern and colour of light as decided by eic)., decoration of terminal building with christmas tree on the occasion of christmas day/new year for 10 days on hiring (rental) basis with following type of decoration accessories (selfie point) with provision for operation for indoor use, including supply and installation of selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. selfie point strength and material should be sufficient enough to sustain it for required days. christmas tree/selfie point having inscription of the occasion as decided by e.i.c. of minimum size 7 x 5 x 5 feet including provision of 02 nos led focus light to focus it. note - 1. the installation & fixing of selfie points shall be completed by 0500 pm, one day prior to the occasion. 2. one location comprising selfie point etc. shall be measure as qty-1 each, annual comprehensive maintenance contract of existing automatic bi-parting (2 leafs) sliding doors including servicing, repairing, supply and replacement of spares as per the requirement and to attend breakdown calls and quarterly visit for preventive maintenance by ensuring safe and smooth functioning of automatic sliding doors to the satisfaction of eic including technical support and spares from oem authorized service er. or equivalent manufacturer approved by eic. the automatic sliding door consists of automation systems make by geze (motor,controller,electronic components, power transmitting device, belt clamp , rollers, cable winder, cables, all safety devices, stoppers etc and i/c all other accessories and parts. the work involves quarterly visit and as and when required by service engineer for doors, carrying out preventive and scheduled maintenance as per oem recommendation and special condition of contract., annual comprehensive maintenance contract of existing 1x20 kva alpha-33 ups (pegasus make unle190361) through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares(except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem or oem authorised dealer only strictly as per the scope of work of special condition of contract., annual comprehensive maintenance contract of existing 20 kva ups (riello make ups s3t 20cpt model) through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares (except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem or oem authorised dealer only strictly as per the scope of work of special condition of contract., annual comprehensive maintenance contract of existing 100 kva ups (vertiv make ups liebert exm series model) in substation for glf through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares (except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem only strictly as per the scope of work of special condition of contract., rewinding of ceiling fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of ceiling fan for 06 months and dismantled material shall be the property of tenderer., rewinding of wall mount fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of wall mount fan for 06 months and dismantled material shall be the property of tenderer., rewinding of exhaust fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of exhaust fan for 06 months and dismantled material shall be the property of tenderer., rewinding of monoblock pump upto 1 hp capacity as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of monoblock pump upto 1 hp capacity for 06 months and dismantled material shall be the property of tenderer., rewinding of sewage / mud pump upto 2 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of sewage / mud pump upto 2 hp for 06 months and dismantled material shall be the property of tenderer., rewinding of submersible motor pump upto 2 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of submersible motor pump upto 2 hp for 06 months and dismantled material shall be the property of tenderer., rewinding of submersible motor pump more than 2 hp & upto 5 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (to be carried out as & when required). note - agency shall be responsible for rewinding and repairing of submersible motor pump more than 2 hp & upto 5 hp for 06 months and dismantled material shall be the property of tenderer., lifting and lowering of submersible pump motor set upto 5hp capacity from the depth upto 80 feet including dismantling of the column pipe, cable etc and reinstallation of pump and motor set in the bore well along with all necessary work like providing and fixing of required gasket & nut bolts, and welding & threading of gi pipe and flange etc as required and making connection to the discharge line after dry revolution test complete as required., re-calibration of available clinometer of ama make from the original equipment manufacturer (oem) for papi calibration, including packing, forwarding, transit insurance, and transportation charges for both dispatch and return at kushinagar international airport, kushinagar., sampling and testing of inlet and treated water from stp at kushinagar airport through a government-approved/authorized laboratory on quarterly basis. analysis to include the following parameters- ph, bod, cod, tss, oil & grease, total dissolved solids (tds), bacteriological - e. coli. submission of detailed test report., repainting of existing cylinderical steel electric poles of perimeter lights with round bracket (up to 3 m height) with one coat epoxy primer and two coats epoxy paint by spray machine or manual by labour , including surface preparation, removal of rust/old paint, cleaning, curing, ladders/scaffolding, protection of nearby fittings, and all labour, materials and equipment, complete as per specifications and engineer-in-charges direction., repainting of existing lt panel with one coat epoxy primer and two coats epoxy paint by spray machine, including surface preparation, removal of rust/old paint, cleaning, curing, protection of adjacent equipment, and all labour, materials, tools & tackles, complete as per specifications without hampering the operations and engineer-in-charges direction., execution of works as per cpwd carrying out any item of dsr (e&m)-2022 works as per site requirement complete as required for attending repair and maintenance, breakdowns and upkeep of internal and external electrical installations as per direction of engineer-in-charge at all locations under kushinagar international airport conforming to cpwd general specifications for electrical works part-i (internal) 2013, part-ii (external) 1994 and part -iv (substation) 2013, and also to relevant bis specifications. the bidder shall quote the rate in inr only for the job corresponding to the base rate (rs. 1,00,000 i/c gst as per proposed estimate) and percentage (percentage) above / below shall be calculated by aai based on quoted rate w.r.t base rate and will be paid as per payment methodology given in annexure- b. for example - if agency desires to quote 5 percentage above on dsr-2022 rates, the rate column shall be filled as rs. 1,05,000.00 i/c gst & if agency desires to quote 5 percentage below on dsr-2022 rates, the rate column shall be filled as rs.95,000.00 i/c gst. note - payment on dsr work shall be paid as per payment methodology given at page no. as annexure-b.


Tender Value : 12659634
Due Date : May 19, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to petrol pump service. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the petrol pump service sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the petrol pump service Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in petrol pump service, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our petrol pump service Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For petrol pump service Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for petrol pump service.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for petrol pump service depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For petrol pump service Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for petrol pump service bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of petrol pump service. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for petrol pump service, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to petrol pump service, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in petrol pump service?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based petrol pump service tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for petrol pump service?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for petrol pump service, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for petrol pump service is declared L1 and is generally awarded the contract