Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

7Results forLatest Off load tap changer Tenders List

Latest Off load tap changer Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Off load tap changer tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Off load tap changer tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Off load tap changer Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Off load tap changer tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Off load tap changer Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Off load tap changer Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Off load tap changer Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Off load tap changer tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Off load tap changer Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Off load tap changer sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Off load tap changer tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Off load tap changer tenders.

Is EMD mandatory for all Off load tap changer tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Off load tap changer work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Off load tap changer tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Off load tap changer Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16239963
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for providing and fixing of 5 or 6 amps piano switch , providing and fixing of 15 or 16 amps piano switch , providing and fixing of 3 pin 5 or 6 amps piano socket , providing and fixing of 6 pin 15 or 16 amps piano socket , providing and fixing of 100watt step type electronic fan regulator , providing and fixing of call bell or buzzer , providing and fixing of 2.5mfd capacitor , providing and fixing of 36watt fl. tube light , providing and fixing of 20w aluminium led batten tubelight , repairing of ceiling fan upto 1400mm sweep , repairing of wall fan upto 450mm sweep , repairing of exhaust fan upto 450mm sweep , providing and fixing of 1400mm sweep, copper wound ceiling fan , repairing of faulty compound light fitting , providing and fixing of 40mm dia heavy duty isi marked brass foot valve , providing and fixing of 50mm dia heavy duty isi marked brass foot valve , providing and fixing of 40mm dia heavy duty upvc pipe , providing and fixing of 50mm dia heavy duty upvc pipe , painting of 16nos. compound light pole, 7nos. water pumps , repairing of 3hp centrifugal water pump , providing and fixing of 12v, 7ah smf battery , providing and fixing of response indicator , providing and fixing of hammer and chain , rectification of fault in existing fd and fa system , replacement of hose pipe alongwith horn , refilling of existing 4.5kg, co2 type fire extinguisher , providing and fixing of space heater , providing and fixing of red or yellow or green colour led indicating lamp , servicing of 11kv, 400amp oil circuit breaker , attending oil leakage of 500kva transformer , servicing and repairing of 800a to 1250a acb , providing and fixing of blue colour led indicating lamp , providing and fixing of 0 to 600v range ac voltmeter of 96 sq.mm size , providing and fixing of 6a vss with control wiring etc. , providing and fixing of operating handle suitable for 1250a acb , providing and fixing of under voltage coil suitable for 800a or 1250a acb , providing and fixing of shunt release coil suitable for 800a or 1250a acb , providing and fixing of 32a, 4way tpn connector , providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link , providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link , providing and fixing of 25kvar md xl type 440v capacitor , providing and fixing of 5kvar md xl type 440v capacitor , providing and fixing of 10kvar md xl type 440v capacitor , repairing of apfc relay of 100kvar capacitor panel , repairing of electrical and mechanical interlocking , providing and fixing of hp cutout , providing and fixing of lp cutout , providing and fixing of hp gauge , providing and fixing of lp gauge , providing and fixing of thermostat , providing and fixing of condenser fan blade , providing and fixing of blower bearing , providing and fixing of mpr d2 overload relay , providing and fixing of 230v a.c. hooter , carrying out nitrogen pressure testing , supplying and charging of r 22 refrigerant gas , providing and fixing of 0.5 hp, 230v a.c. condenser fan motor , providing and fixing of v belt suitable for charging alternator , providing and fixing of 24v dc hooter for dg set panel , attending engine oil leakage, ocm of ems at model colony pune sh attending defects in scope of satyam enterprises at risk and cost, providing and fixing of 5 or 6 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 15 or 16 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 3 pin 5 or 6 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 6 pin 15 or 16 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 100watt step type electronic fan regulator on existing switchboard complete etc. as reqd., providing and fixing of call bell or buzzer suitable for 230v, 1phase ac supply complete etc. as reqd., providing and fixing of 2.5mfd capacitor in existing fan complete etc. as reqd., providing and fixing of 36watt fluorescent tube light complete etc. as reqd., providing and fixing of 20w aluminium led batten tubelight with aluminium heat sink, 6500k cool day light, 2000 lumen for commercial use including testing commissioning etc complete as reqd, repairing of ceiling fan upto 1400mm sweep including removing, servicing, rewinding, varnishing, replacement of bearing, to and fro transportation, reinstallation testing etc complete as reqd., repairing of wall fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, repairing of exhaust fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 1400mm sweep, 80watt, 280 to 370rpm, copper wound ceiling fan incl. 3nos. blade, 30cm long down rod, 2no. canopies etc. suitable for 230v, 1ph ac supply etc. complete as reqd, repairing of faulty compound light fitting incl. supplying and fixing high performance cool daylight 40watts led bulb, alongwith 1.5sqmm copper wiring from pole box to fitting etc complete as reqd, providing and fixing of 40mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 50mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 40mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, providing and fixing of 50mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, painting of 16nos. compound light pole, 7nos. 1hp to 10hp capacity water pumps incl. surface cleaning and applying one or more coats of approved shade synthetic enamel paint complete etc. as reqd., repairing of 3hp centrifugal water pump incl. rewinding, varnishing, greasing, replacement of bearings, nutbolts, gland packing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 12v, 7ah semi maintenance free battery in the existing fire detection panel including connection testing commissioning etc complete as required., providing and fixing of response indicator with metallic cover, 2nos. leds on existing surface or recess ms box including connection testing commissioning etc complete as required., providing and fixing of hammer and chain on existing surface or recess manual call point box etc complete as required., rectification of fault in existing fd and fa system incl. checking of control wiring, repairing of control cards in mcp or lcp, hooters, detectors, ri, pill box, pa system etc complete as required., replacement of hose pipe alongwith horn of 4.5kg co2 type fire extinguisher etc complete as required., refilling of existing 4.5kg, co2 type fire extinguisher including transportation to and fro, hydrualic pressure, testing, cleaning, labling etc. complete as required., providing and fixing of space heater for 11kv ht panel inclding connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp suitable for 110v ac supply in 11kv ht panel including connection, testing, commissioning etc. as reqd., servicing of 11kv, 400amp oil circuit breaker incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, attending oil leakage through tap changer, oil tank of 500kva transformer incl. replacement of gasket, cleaning of oil level guage side glass and fixing of marshalling box cover etc complete as reqd, servicing and repairing of 800a to 1250a acb incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of blue colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in lt panel including connection testing commissioning complete etc. as reqd., providing and fixing of 3 pole and off 6a, voltmeter selector switch with control wiring in lt panel etc. complete as reqd., providing and fixing of operating handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of drawout handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of under voltage coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of shunt release coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of 32a, 4way tpn connector in lt panel with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 25kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 5kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 10kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., repairing of apfc relay of 100kvar capacitor panel including calibration, testing on load and auto mode operation, testing, commissioning etc. as reqd., repairing of electrical and mechanical interlocking between 4nos. incomers and 1no. bus coupler including replacing mechanical locks, wiring, connection, testing, commissioning etc. as reqd., providing and fixing of hp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of hp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of thermostat in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of condenser fan blade in condenser of 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of blower bearing in 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of mpr d2 overload relay in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of 230v a.c. hooter in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., carrying out nitrogen pressure testing and attending leackage of 7tr package ac refrigerant circuit incl. leak testing, flaring, brazing, flushing, vacuumising, purging etc. complete as reqd., supplying and charging of r 22 refrigerant gas in existing 7tr conventional package ac refrigerant circuit etc complete as required., providing and fixing of 0.5 hp, 230v a.c. condenser fan motor suitable for fixing in condenser of sidwal or singhsons make 7tr or 10tr ac pkg unit incl. connection testing comm. etc complete as reqd., providing and fixing of v belt suitable for charging alternator of 500kva cummins make vt 1710g model ea set etc complete as reqd., providing and fixing of 24v dc hooter for dg set panel including connection testing commissioning etc. complete as reqd., attending engine oil leakage at top head and rocker cover, fuel pump etc. incl. replacement of tappet gasket, rubber o rings, mounting washer, high temp. rtv silicone sealant, fuel hoses etc. as reqd.


Tender Value : 0
Due Date : Aug 04, 2026
T18 Ref No : 15714914
Location : kharagpur , west bengal

tender for distribution transformer of rating 250 kva, distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10 % in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank bo dy and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector s ymbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2, 3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). termi nal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/ iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with c able entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with s upply of material: (i) type test report of transformer having same rating, make (& model if any) and desig n from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (par t 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest . detailed specification attached as annexure a. - warranty period: 30 months after the date of delivery pl code : 472005570015


Tender Value : 0
Due Date : Jun 25, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15327818
Source : GEM Tenders

tender for spl repair for replacement of 2 transformer against ber transformers cable termination kit suitable for cables up to and including 33 kv (v2) (q3) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply installation testing commissioning of step down transformer voltage rating ht11 bye 0. 433 kv out door type of capacity 250 kva level 2 3 phase 4 wire 50 hz , supply, installation , testing and commissioning of step down transformer voltage rating ht11 by 0.433 kv, out door type of capacity 315 kva level 2, 3 phase, 4 wire,50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core.complete all as specified and directed in boq spec file , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , material and labour for earthing complete with copper plate electrode 600mmx 600mmx 3.15 mm thick buried directely in ground vertically.complete all as specified and directed in boq spec file , m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file , boaring holes horizontally under road without damaging the surface of road minimum1.0 mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable. , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file , disconnected all electrical connections and earth strip at existing transformerall connected accessories by cables and shifting of 11 kv by 0.433 volts 200 kva to 315 kva capacity transformer., spl repair for replacement of 2 transformer against ber transformers, oil cooled core type floor mounted delta bye star connected maximum losses as defined in vector group dyn 11 double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 250 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories guages first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639 to 1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings bye accessories fitted complete all as specified and directed, oil cooled, core type, floor mounted, delta by star connected maximum losses as defined in vector group dyn 11, double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 315 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories, guages, first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fitting by accessories fitted complete all as specified and directed., insulated screened pvc bedded galvanized steel strip or wire armoured electric power cables heavy duty with standard aluminium conductor 11000 volts earth garde of cross sectional area 3 core 120 sqmm completed all specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 matres below ground level connected to and including galvanised iron strip of size 32 x 6 mm from earth earth electrode to test point bye equipment or up to 7.5 metres whichever is less by means of gi bolts nuts, check nuts and washers all as per electrical plate no 3 of ssr pt 1 and gl watering pipe of 20 mm dia medium grade gi funnel with wire mesh including charcoal salt packed all around the earth electrode plate in layers pcc earth pit chamber 1 ratio 3 ratio 6 type c1 rcc cover 1 ratio 2 ratio 4 type b1 including all excavation bye earth work in any strata and returning filling removal of surplus soil and testing for required value complete all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres below ground level, connected to and including coper strip of size 20x3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-i and gl watering pipe of 20 mm dia medium grade, gl funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1 ratio 3 ratio 6 type c1,rcc cover 1 ratio 2 ratio 4 type b1, including excavation by earth work in any strata and returning filling, removal of surplus soil and testing for required value, m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file, supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in ssr part i and as directed, excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed in boq spec file, returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file, removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file, m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file, boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable all as specified and as directed, supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file, transportation safely by hydra by lifting vehicle including providing suitable carrying vehicle to proposed power houses or mes yard as per suitable directions of engr-in-charge and making all electrical connections properly with earth strip etc and to be re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such nuts, bolts, washers, lugs, sleevs etc and megger testing and complete all as specified and directed in boq spec file


Agency / Dept : indian army
Tender Value : 0
Due Date : May 21, 2026
T18 Ref No : 15669406
Location : budgam , jammu & kashmir
Source : GEM Tenders

tender for procurement of stores for maintenance of tengible assets m sand free from moisture and organic , brick, common burnt clay building bricks , aggregate 20 mm , aggregate 40 mm , pcc solid blocks 400 mm x 200 mm x 200 mm , load bearing concrete hollow blocks , led bulb 7 w confirming to is 16102 , led bulb 9 w confirming to is 16102 , led bulb 12 w confirming to is 16102 , led bulb 18 w confirming to is 16102 , led tube light fitting 1 x 12 w 2 feet long as per is 10322 , led tube light fitting 1 x 18 or 22 w 4 feet long is 10322 , pvc exhaust fan 250mm sweep confirming to is 2312 , plastic body wall mounting fan 450mm sweep - is 374 , ceiling fan sweep 1400mm as per to is 374 , flexible wire pvc insulated twin core with copper conductor , pvc insulated cable 1.5 sqmm single core copper , cable pvc insulated, unsheathed , single core , cable pvc insulated and unsheathed single core , pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809 , switch socket combination 3 or 5 pin 6 amp as per is 3854 , switch socket combination 3 or 5 pin 16 amp -is 3854 , socket 3 pin 5 or 6 amps confirming to is 1293 , socket 3 pin 15 or 16 amps confirming to is 1293 , plug top 3 pin 5 or 6 amp confirming to is 1293 , plug top 3 pin 15 or 16 amp confirming to is 1293 , mcb 16 amp sp confirming to is 60898 , mcb 32 amp sp confirming to is 1293 , mcb 16 amp dp confirming to is 1293 , mcb 32 amp dp confirming to is 1293 , mcb 63 amp dp confirming to is 1293 , bed switch on and off switch as per is 3854 , piano switch one way 6 amps as per is 3854 , piano switch one way 15 or 16 amps as per is 3854 , pvc casing capping 25x16 mm , pvc casing capping square box 4 inch x 4 inch , pendent holder confirming to is 1258 colon 2005 , angle holder with skirt confirming to is 1258 , angle holder confirming to is 1258 , residual circuit current breaker 32 amp dp , residual circuit current breaker 63 amp dp , geyser 15 ltrs with complete accessories , heating device kerosene based heating device , kero heater wicks large confirming to is 1109 , led security light 36w or 40w confirming to is 10322 , led security light 60 or 70w confirming to is 10322 , pvc insulated cable 6 sqmm twin core as per is 694 , pvc insulated service cable aluminium conductor 10 sqmm , mcb distribution bd sheet metal 2 way as per is 13032 , mcb distribution bd sheet metal 4 way confirming to is 13032 , mcb distribution bd sheet metal 8 way confirming to is 13032 , change over switch 32 amp 2 pole confirming to is 13947 , change over switch 63 amp 4 pole confirming to is 13947 , change over 100 amp 4 pole confirming to is 13947 , gi pipe 15mm dia, med grade confirming to is 1239 , gi pipe 20mm dia, med grade confirming to is 1239 , gi elbow 15mm confirming to is 1239 , gi tee 15mm confirming to is 1239 , gi socket 15mm confirming to is 1239 , gi union 15mm confirming to is 1239 , gi nipple 15mm 6 inch long confirming to is 1239 , gi end plug 15mm confirming to is 1239 , gi elbow 20mm confirming to is 1239 part 2 , gi tee 20mm confirming to is 1239 part 2 , gi socket 25mm confirming to is 1239 , gi union 20mm confirming to is 1239 , gi nipple 20 mm dia and 10 cm long confirming to is 1239 , gi tee reducer 20 or 15mm confirming to is 1239 , gi socket reducer 20 or 25mm confirming to is 1239 , gi tank nipple 15 or 20mm confirming to is 1239 , ppr pipe 20mm dia 3 mtr long confirming to is 15801 , ppr elbow 20mm confirming to is 15801 , ppr tee 20mm confirming to is 15801 , ppr socket 20mm confirming to is 15801 , ppr elbow reducer 20 or 25mm confirming to is 15801 , ppr tee reducer 20 or 15mm confirming to is 15801 , ppr union 20mm confirming to is 15801 colon 2008 , ppr end plug 20mm confirming to is 15801 colon 2008 , ppr tank connector 20mm with check nut and washer is 15801 , towel rail cp 750mm long confirming to is 8931colon 2021 , towel ring steel confirming to is 8931colon 2021 , ball brass float valve 15mm confirming to is 1703 colon 2000 , ball brass float valve 20mm confirming to is 1703 colon 2000 , rotational moulded polyethylene water storage tank double layer 1000 ltr , pvc connection pipe 450mm to 650 mm long confirming to is 10124 , brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021 , pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021 , ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021 , wc indian type confirming to is 2556 part 3 colon 2004 , vitreous china wash hand basin white flat back size 550x400 mm , snow white colour european wc with s or p trap size 650x405x770m , stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick , pvc valve less symphonic action type low level flushing cistern 10 ltr , pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021 , upvc 110mm dia single tee confirming to is 13902 colon 2013 , 110mm dia pvc pipe l bend confirming to is 13592 colon 2013 , pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209 , m seal 100 gm each pkt complete confirming to is 9197 colon 1979 , looking mirror 600mm x 450mm confirming to is 3438 colon 2023 , self taping screw 25mm or 1 inch confirming to is 18480 , self taping screw 35mm or 1.5 inch confirming to is 18480 , self taping screw 50mm or 2 inch confirming to is 18480 colon 2025 , self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025 , self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025 , nails 3 inch confirming to is 723 colon 2023, m sand free from moisture and organic, brick, common burnt clay building bricks, aggregate 20 mm, aggregate 40 mm, pcc solid blocks 400 mm x 200 mm x 200 mm, load bearing concrete hollow blocks, led bulb 7 w confirming to is 16102, led bulb 9 w confirming to is 16102, led bulb 12 w confirming to is 16102, led bulb 18 w confirming to is 16102, led tube light fitting 1 x 12 w 2 feet long as per is 10322, led tube light fitting 1 x 18 or 22 w 4 feet long is 10322, pvc exhaust fan 250mm sweep confirming to is 2312, plastic body wall mounting fan 450mm sweep - is 374, ceiling fan sweep 1400mm as per to is 374, flexible wire pvc insulated twin core with copper conductor, pvc insulated cable 1.5 sqmm single core copper, cable pvc insulated, unsheathed , single core, cable pvc insulated and unsheathed single core, pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809, switch socket combination 3 or 5 pin 6 amp as per is 3854, switch socket combination 3 or 5 pin 16 amp -is 3854, socket 3 pin 5 or 6 amps confirming to is 1293, socket 3 pin 15 or 16 amps confirming to is 1293, plug top 3 pin 5 or 6 amp confirming to is 1293, plug top 3 pin 15 or 16 amp confirming to is 1293, mcb 16 amp sp confirming to is 60898, mcb 32 amp sp confirming to is 1293, mcb 16 amp dp confirming to is 1293, mcb 32 amp dp confirming to is 1293, mcb 63 amp dp confirming to is 1293, bed switch on and off switch as per is 3854, piano switch one way 6 amps as per is 3854, piano switch one way 15 or 16 amps as per is 3854, pvc casing capping 25x16 mm, pvc casing capping square box 4 inch x 4 inch, pendent holder confirming to is 1258 colon 2005, angle holder with skirt confirming to is 1258, angle holder confirming to is 1258, residual circuit current breaker 32 amp dp, residual circuit current breaker 63 amp dp, geyser 15 ltrs with complete accessories, heating device kerosene based heating device, kero heater wicks large confirming to is 1109, led security light 36w or 40w confirming to is 10322, led security light 60 or 70w confirming to is 10322, pvc insulated cable 6 sqmm twin core as per is 694, pvc insulated service cable aluminium conductor 10 sqmm, mcb distribution bd sheet metal 2 way as per is 13032, mcb distribution bd sheet metal 4 way confirming to is 13032, mcb distribution bd sheet metal 8 way confirming to is 13032, change over switch 32 amp 2 pole confirming to is 13947, change over switch 63 amp 4 pole confirming to is 13947, change over 100 amp 4 pole confirming to is 13947, gi pipe 15mm dia, med grade confirming to is 1239, gi pipe 20mm dia, med grade confirming to is 1239, gi elbow 15mm confirming to is 1239, gi tee 15mm confirming to is 1239, gi socket 15mm confirming to is 1239, gi union 15mm confirming to is 1239, gi nipple 15mm 6 inch long confirming to is 1239, gi end plug 15mm confirming to is 1239, gi elbow 20mm confirming to is 1239 part 2, gi tee 20mm confirming to is 1239 part 2, gi socket 25mm confirming to is 1239, gi union 20mm confirming to is 1239, gi nipple 20 mm dia and 10 cm long confirming to is 1239, gi tee reducer 20 or 15mm confirming to is 1239, gi socket reducer 20 or 25mm confirming to is 1239, gi tank nipple 15 or 20mm confirming to is 1239, ppr pipe 20mm dia 3 mtr long confirming to is 15801, ppr elbow 20mm confirming to is 15801, ppr tee 20mm confirming to is 15801, ppr socket 20mm confirming to is 15801, ppr elbow reducer 20 or 25mm confirming to is 15801, ppr tee reducer 20 or 15mm confirming to is 15801, ppr union 20mm confirming to is 15801 colon 2008, ppr end plug 20mm confirming to is 15801 colon 2008, ppr tank connector 20mm with check nut and washer is 15801, towel rail cp 750mm long confirming to is 8931colon 2021, towel ring steel confirming to is 8931colon 2021, ball brass float valve 15mm confirming to is 1703 colon 2000, ball brass float valve 20mm confirming to is 1703 colon 2000, rotational moulded polyethylene water storage tank double layer 1000 ltr, pvc connection pipe 450mm to 650 mm long confirming to is 10124, brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021, pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021, ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021, wc indian type confirming to is 2556 part 3 colon 2004, vitreous china wash hand basin white flat back size 550x400 mm, snow white colour european wc with s or p trap size 650x405x770m, stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick, pvc valve less symphonic action type low level flushing cistern 10 ltr, pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021, upvc 110mm dia single tee confirming to is 13902 colon 2013, 110mm dia pvc pipe l bend confirming to is 13592 colon 2013, pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209, m seal 100 gm each pkt complete confirming to is 9197 colon 1979, looking mirror 600mm x 450mm confirming to is 3438 colon 2023, self taping screw 25mm or 1 inch confirming to is 18480, self taping screw 35mm or 1.5 inch confirming to is 18480, self taping screw 50mm or 2 inch confirming to is 18480 colon 2025, self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025, self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025, nails 3 inch confirming to is 723 colon 2023, nails 5 inch confirming to is 723 colon 2023, ms screw 25mm 100 per pkt confirming to is 1367 part 1, ms binding wire not less than 0.9mm dia confirming to is 280, ppgi sheet 10 feet x 3 feet x 0.50mm confirming to is 14246 colon 2024, ppgi sheet 12 feet x 3 feet x0.50mm confirming to is 14246 colon 2024, welding rod confirming to is 814 colon 2004 reaffirmed 2021, door hinges size 4 inch long medium weight steel 100mm as per is 1341, tower bolt 150mm confirming to is 204 colon part 1, ss locking door latches confirming to is 16015 colon 2022, door handle steel 8 inch confirming to is 208 colon 2020, bow handle 100mm confirming to is 208 colon 2020, door stopper confirming to is 281 colon 2009, hydraulic door closer confirming to is 3564 colon 2025, hdpe laminated sand bag of size 75 x 40 cm as per is 9755, measuring tape 5m length steel confirming to is 1269, synthetic enamel paint colour black confirming to is 2932, synthetic enamel paint colour white confirming to is 2932, synthetic enamel paint colour og confirming to is 2932, synthetic enamel paint colour green confirming to is 2932, white cement confirming to is 8042, tiles ceramic 300x300mm, 7-8mm thick confirming to is 15322, tiles ceramic 400x400mm, 7-8mm thick confirming to is 15322, tiles ceramic 600x600mm, 7-8mm thick confirming to is 15322, 60mm thick pcc inter locking coloured tiles machine pressed of m 35 grade, acrylic sheet 4 feetx3 feet x3mm confirming to is 10146, acrylic sheet 6 feet x4 feet x4mm confirming to is 10146, pbs roll self finished tarfelt grade i as per is 1322, cgi sheet 810 x 3050 mm long, 0.63mm thick 10 feet as per is 277, cgi sheet 810 x 3657 mm long, 0.63mm thick 12 feet as per is 277, ply wood 8 feet x 4 feet x 6mm thick as per is 303, ply wood 8 feet x 4 feet x 8mm thick as per is 303, ply wood 8 feet x 4 feet x 12mm thick as per is 303, ply wood 6 feet x 3 feet x 12mm thick as per is 303


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 06, 2026
T18 Ref No : 15674587
Location : budgam , jammu & kashmir
Source : GEM Tenders

corrigendum tender for procurement of stores for maintenance of tengible assets m sand free from moisture and organic , brick, common burnt clay building bricks , aggregate 20 mm , aggregate 40 mm , pcc solid blocks 400 mm x 200 mm x 200 mm , load bearing concrete hollow blocks , led bulb 7 w confirming to is 16102 , led bulb 9 w confirming to is 16102 , led bulb 12 w confirming to is 16102 , led bulb 18 w confirming to is 16102 , led tube light fitting 1 x 12 w 2 feet long as per is 10322 , led tube light fitting 1 x 18 or 22 w 4 feet long is 10322 , pvc exhaust fan 250mm sweep confirming to is 2312 , plastic body wall mounting fan 450mm sweep - is 374 , ceiling fan sweep 1400mm as per to is 374 , flexible wire pvc insulated twin core with copper conductor , pvc insulated cable 1.5 sqmm single core copper , cable pvc insulated, unsheathed , single core , cable pvc insulated and unsheathed single core , pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809 , switch socket combination 3 or 5 pin 6 amp as per is 3854 , switch socket combination 3 or 5 pin 16 amp -is 3854 , socket 3 pin 5 or 6 amps confirming to is 1293 , socket 3 pin 15 or 16 amps confirming to is 1293 , plug top 3 pin 5 or 6 amp confirming to is 1293 , plug top 3 pin 15 or 16 amp confirming to is 1293 , mcb 16 amp sp confirming to is 60898 , mcb 32 amp sp confirming to is 1293 , mcb 16 amp dp confirming to is 1293 , mcb 32 amp dp confirming to is 1293 , mcb 63 amp dp confirming to is 1293 , bed switch on and off switch as per is 3854 , piano switch one way 6 amps as per is 3854 , piano switch one way 15 or 16 amps as per is 3854 , pvc casing capping 25x16 mm , pvc casing capping square box 4 inch x 4 inch , pendent holder confirming to is 1258 colon 2005 , angle holder with skirt confirming to is 1258 , angle holder confirming to is 1258 , residual circuit current breaker 32 amp dp , residual circuit current breaker 63 amp dp , geyser 15 ltrs with complete accessories , heating device kerosene based heating device , kero heater wicks large confirming to is 1109 , led security light 36w or 40w confirming to is 10322 , led security light 60 or 70w confirming to is 10322 , pvc insulated cable 6 sqmm twin core as per is 694 , pvc insulated service cable aluminium conductor 10 sqmm , mcb distribution bd sheet metal 2 way as per is 13032 , mcb distribution bd sheet metal 4 way confirming to is 13032 , mcb distribution bd sheet metal 8 way confirming to is 13032 , change over switch 32 amp 2 pole confirming to is 13947 , change over switch 63 amp 4 pole confirming to is 13947 , change over 100 amp 4 pole confirming to is 13947 , gi pipe 15mm dia, med grade confirming to is 1239 , gi pipe 20mm dia, med grade confirming to is 1239 , gi elbow 15mm confirming to is 1239 , gi tee 15mm confirming to is 1239 , gi socket 15mm confirming to is 1239 , gi union 15mm confirming to is 1239 , gi nipple 15mm 6 inch long confirming to is 1239 , gi end plug 15mm confirming to is 1239 , gi elbow 20mm confirming to is 1239 part 2 , gi tee 20mm confirming to is 1239 part 2 , gi socket 25mm confirming to is 1239 , gi union 20mm confirming to is 1239 , gi nipple 20 mm dia and 10 cm long confirming to is 1239 , gi tee reducer 20 or 15mm confirming to is 1239 , gi socket reducer 20 or 25mm confirming to is 1239 , gi tank nipple 15 or 20mm confirming to is 1239 , ppr pipe 20mm dia 3 mtr long confirming to is 15801 , ppr elbow 20mm confirming to is 15801 , ppr tee 20mm confirming to is 15801 , ppr socket 20mm confirming to is 15801 , ppr elbow reducer 20 or 25mm confirming to is 15801 , ppr tee reducer 20 or 15mm confirming to is 15801 , ppr union 20mm confirming to is 15801 colon 2008 , ppr end plug 20mm confirming to is 15801 colon 2008 , ppr tank connector 20mm with check nut and washer is 15801 , towel rail cp 750mm long confirming to is 8931colon 2021 , towel ring steel confirming to is 8931colon 2021 , ball brass float valve 15mm confirming to is 1703 colon 2000 , ball brass float valve 20mm confirming to is 1703 colon 2000 , rotational moulded polyethylene water storage tank double layer 1000 ltr , pvc connection pipe 450mm to 650 mm long confirming to is 10124 , brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021 , pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021 , ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021 , wc indian type confirming to is 2556 part 3 colon 2004 , vitreous china wash hand basin white flat back size 550x400 mm , snow white colour european wc with s or p trap size 650x405x770m , stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick , pvc valve less symphonic action type low level flushing cistern 10 ltr , pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021 , upvc 110mm dia single tee confirming to is 13902 colon 2013 , 110mm dia pvc pipe l bend confirming to is 13592 colon 2013 , pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209 , m seal 100 gm each pkt complete confirming to is 9197 colon 1979 , looking mirror 600mm x 450mm confirming to is 3438 colon 2023 , self taping screw 25mm or 1 inch confirming to is 18480 , self taping screw 35mm or 1.5 inch confirming to is 18480 , self taping screw 50mm or 2 inch confirming to is 18480 colon 2025 , self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025 , self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025 , nails 3 inch confirming to is 723 colon 2023, m sand free from moisture and organic, brick, common burnt clay building bricks, aggregate 20 mm, aggregate 40 mm, pcc solid blocks 400 mm x 200 mm x 200 mm, load bearing concrete hollow blocks, led bulb 7 w confirming to is 16102, led bulb 9 w confirming to is 16102, led bulb 12 w confirming to is 16102, led bulb 18 w confirming to is 16102, led tube light fitting 1 x 12 w 2 feet long as per is 10322, led tube light fitting 1 x 18 or 22 w 4 feet long is 10322, pvc exhaust fan 250mm sweep confirming to is 2312, plastic body wall mounting fan 450mm sweep - is 374, ceiling fan sweep 1400mm as per to is 374, flexible wire pvc insulated twin core with copper conductor, pvc insulated cable 1.5 sqmm single core copper, cable pvc insulated, unsheathed , single core, cable pvc insulated and unsheathed single core, pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809, switch socket combination 3 or 5 pin 6 amp as per is 3854, switch socket combination 3 or 5 pin 16 amp -is 3854, socket 3 pin 5 or 6 amps confirming to is 1293, socket 3 pin 15 or 16 amps confirming to is 1293, plug top 3 pin 5 or 6 amp confirming to is 1293, plug top 3 pin 15 or 16 amp confirming to is 1293, mcb 16 amp sp confirming to is 60898, mcb 32 amp sp confirming to is 1293, mcb 16 amp dp confirming to is 1293, mcb 32 amp dp confirming to is 1293, mcb 63 amp dp confirming to is 1293, bed switch on and off switch as per is 3854, piano switch one way 6 amps as per is 3854, piano switch one way 15 or 16 amps as per is 3854, pvc casing capping 25x16 mm, pvc casing capping square box 4 inch x 4 inch, pendent holder confirming to is 1258 colon 2005, angle holder with skirt confirming to is 1258, angle holder confirming to is 1258, residual circuit current breaker 32 amp dp, residual circuit current breaker 63 amp dp, geyser 15 ltrs with complete accessories, heating device kerosene based heating device, kero heater wicks large confirming to is 1109, led security light 36w or 40w confirming to is 10322, led security light 60 or 70w confirming to is 10322, pvc insulated cable 6 sqmm twin core as per is 694, pvc insulated service cable aluminium conductor 10 sqmm, mcb distribution bd sheet metal 2 way as per is 13032, mcb distribution bd sheet metal 4 way confirming to is 13032, mcb distribution bd sheet metal 8 way confirming to is 13032, change over switch 32 amp 2 pole confirming to is 13947, change over switch 63 amp 4 pole confirming to is 13947, change over 100 amp 4 pole confirming to is 13947, gi pipe 15mm dia, med grade confirming to is 1239, gi pipe 20mm dia, med grade confirming to is 1239, gi elbow 15mm confirming to is 1239, gi tee 15mm confirming to is 1239, gi socket 15mm confirming to is 1239, gi union 15mm confirming to is 1239, gi nipple 15mm 6 inch long confirming to is 1239, gi end plug 15mm confirming to is 1239, gi elbow 20mm confirming to is 1239 part 2, gi tee 20mm confirming to is 1239 part 2, gi socket 25mm confirming to is 1239, gi union 20mm confirming to is 1239, gi nipple 20 mm dia and 10 cm long confirming to is 1239, gi tee reducer 20 or 15mm confirming to is 1239, gi socket reducer 20 or 25mm confirming to is 1239, gi tank nipple 15 or 20mm confirming to is 1239, ppr pipe 20mm dia 3 mtr long confirming to is 15801, ppr elbow 20mm confirming to is 15801, ppr tee 20mm confirming to is 15801, ppr socket 20mm confirming to is 15801, ppr elbow reducer 20 or 25mm confirming to is 15801, ppr tee reducer 20 or 15mm confirming to is 15801, ppr union 20mm confirming to is 15801 colon 2008, ppr end plug 20mm confirming to is 15801 colon 2008, ppr tank connector 20mm with check nut and washer is 15801, towel rail cp 750mm long confirming to is 8931colon 2021, towel ring steel confirming to is 8931colon 2021, ball brass float valve 15mm confirming to is 1703 colon 2000, ball brass float valve 20mm confirming to is 1703 colon 2000, rotational moulded polyethylene water storage tank double layer 1000 ltr, pvc connection pipe 450mm to 650 mm long confirming to is 10124, brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021, pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021, ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021, wc indian type confirming to is 2556 part 3 colon 2004, vitreous china wash hand basin white flat back size 550x400 mm, snow white colour european wc with s or p trap size 650x405x770m, stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick, pvc valve less symphonic action type low level flushing cistern 10 ltr, pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021, upvc 110mm dia single tee confirming to is 13902 colon 2013, 110mm dia pvc pipe l bend confirming to is 13592 colon 2013, pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209, m seal 100 gm each pkt complete confirming to is 9197 colon 1979, looking mirror 600mm x 450mm confirming to is 3438 colon 2023, self taping screw 25mm or 1 inch confirming to is 18480, self taping screw 35mm or 1.5 inch confirming to is 18480, self taping screw 50mm or 2 inch confirming to is 18480 colon 2025, self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025, self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025, nails 3 inch confirming to is 723 colon 2023, nails 5 inch confirming to is 723 colon 2023, ms screw 25mm 100 per pkt confirming to is 1367 part 1, ms binding wire not less than 0.9mm dia confirming to is 280, ppgi sheet 10 feet x 3 feet x 0.50mm confirming to is 14246 colon 2024, ppgi sheet 12 feet x 3 feet x0.50mm confirming to is 14246 colon 2024, welding rod confirming to is 814 colon 2004 reaffirmed 2021, door hinges size 4 inch long medium weight steel 100mm as per is 1341, tower bolt 150mm confirming to is 204 colon part 1, ss locking door latches confirming to is 16015 colon 2022, door handle steel 8 inch confirming to is 208 colon 2020, bow handle 100mm confirming to is 208 colon 2020, door stopper confirming to is 281 colon 2009, hydraulic door closer confirming to is 3564 colon 2025, hdpe laminated sand bag of size 75 x 40 cm as per is 9755, measuring tape 5m length steel confirming to is 1269, synthetic enamel paint colour black confirming to is 2932, synthetic enamel paint colour white confirming to is 2932, synthetic enamel paint colour og confirming to is 2932, synthetic enamel paint colour green confirming to is 2932, white cement confirming to is 8042, tiles ceramic 300x300mm, 7-8mm thick confirming to is 15322, tiles ceramic 400x400mm, 7-8mm thick confirming to is 15322, tiles ceramic 600x600mm, 7-8mm thick confirming to is 15322, 60mm thick pcc inter locking coloured tiles machine pressed of m 35 grade, acrylic sheet 4 feetx3 feet x3mm confirming to is 10146, acrylic sheet 6 feet x4 feet x4mm confirming to is 10146, pbs roll self finished tarfelt grade i as per is 1322, cgi sheet 810 x 3050 mm long, 0.63mm thick 10 feet as per is 277, cgi sheet 810 x 3657 mm long, 0.63mm thick 12 feet as per is 277, ply wood 8 feet x 4 feet x 6mm thick as per is 303, ply wood 8 feet x 4 feet x 8mm thick as per is 303, ply wood 8 feet x 4 feet x 12mm thick as per is 303, ply wood 6 feet x 3 feet x 12mm thick as per is 303


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 10, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15702800
Location : budgam , jammu & kashmir
Source : GEM Tenders

corrigendum tender for procurement of stores for maintenance of tengible assets m sand free from moisture and organic , brick, common burnt clay building bricks , aggregate 20 mm , aggregate 40 mm , pcc solid blocks 400 mm x 200 mm x 200 mm , load bearing concrete hollow blocks , led bulb 7 w confirming to is 16102 , led bulb 9 w confirming to is 16102 , led bulb 12 w confirming to is 16102 , led bulb 18 w confirming to is 16102 , led tube light fitting 1 x 12 w 2 feet long as per is 10322 , led tube light fitting 1 x 18 or 22 w 4 feet long is 10322 , pvc exhaust fan 250mm sweep confirming to is 2312 , plastic body wall mounting fan 450mm sweep - is 374 , ceiling fan sweep 1400mm as per to is 374 , flexible wire pvc insulated twin core with copper conductor , pvc insulated cable 1.5 sqmm single core copper , cable pvc insulated, unsheathed , single core , cable pvc insulated and unsheathed single core , pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809 , switch socket combination 3 or 5 pin 6 amp as per is 3854 , switch socket combination 3 or 5 pin 16 amp -is 3854 , socket 3 pin 5 or 6 amps confirming to is 1293 , socket 3 pin 15 or 16 amps confirming to is 1293 , plug top 3 pin 5 or 6 amp confirming to is 1293 , plug top 3 pin 15 or 16 amp confirming to is 1293 , mcb 16 amp sp confirming to is 60898 , mcb 32 amp sp confirming to is 1293 , mcb 16 amp dp confirming to is 1293 , mcb 32 amp dp confirming to is 1293 , mcb 63 amp dp confirming to is 1293 , bed switch on and off switch as per is 3854 , piano switch one way 6 amps as per is 3854 , piano switch one way 15 or 16 amps as per is 3854 , pvc casing capping 25x16 mm , pvc casing capping square box 4 inch x 4 inch , pendent holder confirming to is 1258 colon 2005 , angle holder with skirt confirming to is 1258 , angle holder confirming to is 1258 , residual circuit current breaker 32 amp dp , residual circuit current breaker 63 amp dp , geyser 15 ltrs with complete accessories , heating device kerosene based heating device , kero heater wicks large confirming to is 1109 , led security light 36w or 40w confirming to is 10322 , led security light 60 or 70w confirming to is 10322 , pvc insulated cable 6 sqmm twin core as per is 694 , pvc insulated service cable aluminium conductor 10 sqmm , mcb distribution bd sheet metal 2 way as per is 13032 , mcb distribution bd sheet metal 4 way confirming to is 13032 , mcb distribution bd sheet metal 8 way confirming to is 13032 , change over switch 32 amp 2 pole confirming to is 13947 , change over switch 63 amp 4 pole confirming to is 13947 , change over 100 amp 4 pole confirming to is 13947 , gi pipe 15mm dia, med grade confirming to is 1239 , gi pipe 20mm dia, med grade confirming to is 1239 , gi elbow 15mm confirming to is 1239 , gi tee 15mm confirming to is 1239 , gi socket 15mm confirming to is 1239 , gi union 15mm confirming to is 1239 , gi nipple 15mm 6 inch long confirming to is 1239 , gi end plug 15mm confirming to is 1239 , gi elbow 20mm confirming to is 1239 part 2 , gi tee 20mm confirming to is 1239 part 2 , gi socket 25mm confirming to is 1239 , gi union 20mm confirming to is 1239 , gi nipple 20 mm dia and 10 cm long confirming to is 1239 , gi tee reducer 20 or 15mm confirming to is 1239 , gi socket reducer 20 or 25mm confirming to is 1239 , gi tank nipple 15 or 20mm confirming to is 1239 , ppr pipe 20mm dia 3 mtr long confirming to is 15801 , ppr elbow 20mm confirming to is 15801 , ppr tee 20mm confirming to is 15801 , ppr socket 20mm confirming to is 15801 , ppr elbow reducer 20 or 25mm confirming to is 15801 , ppr tee reducer 20 or 15mm confirming to is 15801 , ppr union 20mm confirming to is 15801 colon 2008 , ppr end plug 20mm confirming to is 15801 colon 2008 , ppr tank connector 20mm with check nut and washer is 15801 , towel rail cp 750mm long confirming to is 8931colon 2021 , towel ring steel confirming to is 8931colon 2021 , ball brass float valve 15mm confirming to is 1703 colon 2000 , ball brass float valve 20mm confirming to is 1703 colon 2000 , rotational moulded polyethylene water storage tank double layer 1000 ltr , pvc connection pipe 450mm to 650 mm long confirming to is 10124 , brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021 , pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021 , ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021 , wc indian type confirming to is 2556 part 3 colon 2004 , vitreous china wash hand basin white flat back size 550x400 mm , snow white colour european wc with s or p trap size 650x405x770m , stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick , pvc valve less symphonic action type low level flushing cistern 10 ltr , pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021 , upvc 110mm dia single tee confirming to is 13902 colon 2013 , 110mm dia pvc pipe l bend confirming to is 13592 colon 2013 , pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209 , m seal 100 gm each pkt complete confirming to is 9197 colon 1979 , looking mirror 600mm x 450mm confirming to is 3438 colon 2023 , self taping screw 25mm or 1 inch confirming to is 18480 , self taping screw 35mm or 1.5 inch confirming to is 18480 , self taping screw 50mm or 2 inch confirming to is 18480 colon 2025 , self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025 , self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025 , nails 3 inch confirming to is 723 colon 2023, m sand free from moisture and organic, brick, common burnt clay building bricks, aggregate 20 mm, aggregate 40 mm, pcc solid blocks 400 mm x 200 mm x 200 mm, load bearing concrete hollow blocks, led bulb 7 w confirming to is 16102, led bulb 9 w confirming to is 16102, led bulb 12 w confirming to is 16102, led bulb 18 w confirming to is 16102, led tube light fitting 1 x 12 w 2 feet long as per is 10322, led tube light fitting 1 x 18 or 22 w 4 feet long is 10322, pvc exhaust fan 250mm sweep confirming to is 2312, plastic body wall mounting fan 450mm sweep - is 374, ceiling fan sweep 1400mm as per to is 374, flexible wire pvc insulated twin core with copper conductor, pvc insulated cable 1.5 sqmm single core copper, cable pvc insulated, unsheathed , single core, cable pvc insulated and unsheathed single core, pvc insulation tape 2 cm wide 10 mtrs long confirming to is 7809, switch socket combination 3 or 5 pin 6 amp as per is 3854, switch socket combination 3 or 5 pin 16 amp -is 3854, socket 3 pin 5 or 6 amps confirming to is 1293, socket 3 pin 15 or 16 amps confirming to is 1293, plug top 3 pin 5 or 6 amp confirming to is 1293, plug top 3 pin 15 or 16 amp confirming to is 1293, mcb 16 amp sp confirming to is 60898, mcb 32 amp sp confirming to is 1293, mcb 16 amp dp confirming to is 1293, mcb 32 amp dp confirming to is 1293, mcb 63 amp dp confirming to is 1293, bed switch on and off switch as per is 3854, piano switch one way 6 amps as per is 3854, piano switch one way 15 or 16 amps as per is 3854, pvc casing capping 25x16 mm, pvc casing capping square box 4 inch x 4 inch, pendent holder confirming to is 1258 colon 2005, angle holder with skirt confirming to is 1258, angle holder confirming to is 1258, residual circuit current breaker 32 amp dp, residual circuit current breaker 63 amp dp, geyser 15 ltrs with complete accessories, heating device kerosene based heating device, kero heater wicks large confirming to is 1109, led security light 36w or 40w confirming to is 10322, led security light 60 or 70w confirming to is 10322, pvc insulated cable 6 sqmm twin core as per is 694, pvc insulated service cable aluminium conductor 10 sqmm, mcb distribution bd sheet metal 2 way as per is 13032, mcb distribution bd sheet metal 4 way confirming to is 13032, mcb distribution bd sheet metal 8 way confirming to is 13032, change over switch 32 amp 2 pole confirming to is 13947, change over switch 63 amp 4 pole confirming to is 13947, change over 100 amp 4 pole confirming to is 13947, gi pipe 15mm dia, med grade confirming to is 1239, gi pipe 20mm dia, med grade confirming to is 1239, gi elbow 15mm confirming to is 1239, gi tee 15mm confirming to is 1239, gi socket 15mm confirming to is 1239, gi union 15mm confirming to is 1239, gi nipple 15mm 6 inch long confirming to is 1239, gi end plug 15mm confirming to is 1239, gi elbow 20mm confirming to is 1239 part 2, gi tee 20mm confirming to is 1239 part 2, gi socket 25mm confirming to is 1239, gi union 20mm confirming to is 1239, gi nipple 20 mm dia and 10 cm long confirming to is 1239, gi tee reducer 20 or 15mm confirming to is 1239, gi socket reducer 20 or 25mm confirming to is 1239, gi tank nipple 15 or 20mm confirming to is 1239, ppr pipe 20mm dia 3 mtr long confirming to is 15801, ppr elbow 20mm confirming to is 15801, ppr tee 20mm confirming to is 15801, ppr socket 20mm confirming to is 15801, ppr elbow reducer 20 or 25mm confirming to is 15801, ppr tee reducer 20 or 15mm confirming to is 15801, ppr union 20mm confirming to is 15801 colon 2008, ppr end plug 20mm confirming to is 15801 colon 2008, ppr tank connector 20mm with check nut and washer is 15801, towel rail cp 750mm long confirming to is 8931colon 2021, towel ring steel confirming to is 8931colon 2021, ball brass float valve 15mm confirming to is 1703 colon 2000, ball brass float valve 20mm confirming to is 1703 colon 2000, rotational moulded polyethylene water storage tank double layer 1000 ltr, pvc connection pipe 450mm to 650 mm long confirming to is 10124, brass bib cock 15mm confirming to is 8931 colon 1978 reaffirmed 2021, pvc bib cock 15mm confirming to is 9763 colon 2020 reaffirmed 2021, ptmt bib cock 15 mm confirming to is 9763 colon 2020 reaffirmed 2021, wc indian type confirming to is 2556 part 3 colon 2004, vitreous china wash hand basin white flat back size 550x400 mm, snow white colour european wc with s or p trap size 650x405x770m, stainless steel lavatory pan of size 550 mm x 480 mm x 1mm thick, pvc valve less symphonic action type low level flushing cistern 10 ltr, pvc pipe 4 inch or 110mm dia 3 mtr long confirming to is 4985 colon 2021, upvc 110mm dia single tee confirming to is 13902 colon 2013, 110mm dia pvc pipe l bend confirming to is 13592 colon 2013, pvc socket 110 mm confirming to is 10124 part 1 to 13 colon 209, m seal 100 gm each pkt complete confirming to is 9197 colon 1979, looking mirror 600mm x 450mm confirming to is 3438 colon 2023, self taping screw 25mm or 1 inch confirming to is 18480, self taping screw 35mm or 1.5 inch confirming to is 18480, self taping screw 50mm or 2 inch confirming to is 18480 colon 2025, self tapping screw 75mm or 3 inch confirming to is 18480 colon 2025, self tapping screw 100mm or 4 inch confirming to is 18480 colon 2025, nails 3 inch confirming to is 723 colon 2023, nails 5 inch confirming to is 723 colon 2023, ms screw 25mm 100 per pkt confirming to is 1367 part 1, ms binding wire not less than 0.9mm dia confirming to is 280, ppgi sheet 10 feet x 3 feet x 0.50mm confirming to is 14246 colon 2024, ppgi sheet 12 feet x 3 feet x0.50mm confirming to is 14246 colon 2024, welding rod confirming to is 814 colon 2004 reaffirmed 2021, door hinges size 4 inch long medium weight steel 100mm as per is 1341, tower bolt 150mm confirming to is 204 colon part 1, ss locking door latches confirming to is 16015 colon 2022, door handle steel 8 inch confirming to is 208 colon 2020, bow handle 100mm confirming to is 208 colon 2020, door stopper confirming to is 281 colon 2009, hydraulic door closer confirming to is 3564 colon 2025, hdpe laminated sand bag of size 75 x 40 cm as per is 9755, measuring tape 5m length steel confirming to is 1269, synthetic enamel paint colour black confirming to is 2932, synthetic enamel paint colour white confirming to is 2932, synthetic enamel paint colour og confirming to is 2932, synthetic enamel paint colour green confirming to is 2932, white cement confirming to is 8042, tiles ceramic 300x300mm, 7-8mm thick confirming to is 15322, tiles ceramic 400x400mm, 7-8mm thick confirming to is 15322, tiles ceramic 600x600mm, 7-8mm thick confirming to is 15322, 60mm thick pcc inter locking coloured tiles machine pressed of m 35 grade, acrylic sheet 4 feetx3 feet x3mm confirming to is 10146, acrylic sheet 6 feet x4 feet x4mm confirming to is 10146, pbs roll self finished tarfelt grade i as per is 1322, cgi sheet 810 x 3050 mm long, 0.63mm thick 10 feet as per is 277, cgi sheet 810 x 3657 mm long, 0.63mm thick 12 feet as per is 277, ply wood 8 feet x 4 feet x 6mm thick as per is 303, ply wood 8 feet x 4 feet x 8mm thick as per is 303, ply wood 8 feet x 4 feet x 12mm thick as per is 303, ply wood 6 feet x 3 feet x 12mm thick as per is 303


Agency / Dept :
Tender Value : 0
Due Date : Jun 12, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Off Load Tap Changer. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Off Load Tap Changer sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Off Load Tap Changer Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Off Load Tap Changer, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Off Load Tap Changer Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Off Load Tap Changer Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Off Load Tap Changer.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Off Load Tap Changer depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Off Load Tap Changer Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Off Load Tap Changer bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Off Load Tap Changer. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Off Load Tap Changer, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Off Load Tap Changer, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Off Load Tap Changer?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Off Load Tap Changer tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Off Load Tap Changer?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Off Load Tap Changer, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Off Load Tap Changer is declared L1 and is generally awarded the contract