Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

8Latest Fire alarm control panel repair Tenders List

Latest Fire alarm control panel repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Fire alarm control panel repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Fire alarm control panel repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Fire alarm control panel repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Fire alarm control panel repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Fire alarm control panel repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Fire alarm control panel repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Fire alarm control panel repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Fire alarm control panel repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Fire alarm control panel repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Fire alarm control panel repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Fire alarm control panel repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Fire alarm control panel repair tenders.

Is EMD mandatory for all Fire alarm control panel repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Fire alarm control panel repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Fire alarm control panel repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Fire alarm control panel repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 17520397
Location : lucknow , uttar pradesh
Source : GEM Tenders
LIVE TENDER
tender for main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , s and fixing internal hydrant valve , supply and fixing of external yard hydrant valve , sfc of butterfly valve , s and fixing of orifice plate , pitc non return valve , pitc of stainless steel y strainer , s and fixing of 15 m hose pipe , s and fixing first aid hose reel , s and fixing 63 mm dia gun metal short branch pipe , s and fixing of fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , installation control valve of cast iron body , s and f of hose cabinet , cutting holes , supply of cable , laying of cable , s and m end termination , s and f fire cable , cable tray , g i plate earthing , p and f gi strip , gi strip for looping , p and f gi earth wire , p and f gi pipe, supply installation testing and commissioning of firefighting with wet riser system, sh 1 wet riser system main fire pump a supplying, installation, testing and commissioning of electric driven main fire pump conforming to is 12469 2019 suitable for automatic peration and consisting of following complete in all respects as required. b horizontal type multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft fire pump capable for delivery of 2280 lpm against atotal head of 70 mtrs approximately while running at 1450 1500 rpm mechanical seal as required bsnl approved make. c suitable hp squirrel cage induction motor tefc synchronous speed 1500 rpm suitable for operation on 415 volts 3 phase 50 hz ac supply with ip 55 protection for enclosure horizontal foot mounted type with class. f insulation conforming to is 12615 2018. d m.s. fabricated common base plate coupling,coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered with anti vibration pads note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank. 2280 lpm at 70 m head, diesel driven pump a supplying, installation, testing and commissioning of die sel engine driven main fire pump conforming to is 12469 019 suitable for automatic operation and consisting of following, complete in all respects, as required diesel driven pump b horizontal pe, stage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 lpm against atoatl head of 70 mtrs approxi as required.c suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe xtended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential ilencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.d. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as quired. e suitable cement concrete foundation duly plastered and with anti vibration pads. note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank. 2280 lpm at 70 m head., jockey pump a supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects as required jockey pump b horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c)suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) suitable cement concrete foundation duly plastered and with anti vibration pads. note the pump room is situated on the underground water tank. 180 lpm at 70 m head, supplying, installation, testing and commissioning of electric driven terrace pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects, as required terrace pump. b horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m head., control panels fabrication supply installation testing and commissioning of electrical control panel of cubical construction floor mounted type fabricated out of 2mm thick crca, artmentalised with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring earth terminals, numbering etc. complete, suitable for main fire pump, pressurisation pump and diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required. incoming 250a, 50ka 4 pole mccb, ic equal to 100 percent icu rating digital voltmeter 0 500v with selector switch digital ammeter 0 250 a with selector swtich and cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 300a. outgoing note all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps main fire pump 125 a, 50katpn mccb, ics is equal to 100 percent icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation. jockey pump jockey pump 63 a, 50ka tpn mccb, icsis equal to 100 percent icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, note may please be see at atc of special repair no. 5, supply installation testing and commissioning of fully automatic dol starter for terrace pump terrace pump siutable for operation on 3 phase 415 volt ac supply i/c making inter connection testing etc as requiored at site., sh ii pipes and accessories. providing laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia wall thickness 6.3 mm, supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required.single headed gunmetal, supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required. single headed gunmetal, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required . 50mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .80 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .100 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .150 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .200 mm dia, supplying and fixing orifice plate made out of 6 mm thick stainless steel grade 304 with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required., providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 50mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 80 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 100 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 150 mm dia., providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia, supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and femalecouplings duly bound with gi wire, rivets etc. conforming to is 636 type a as required. gun metal, supplying and fixing first aid hose reel with ms construction spray painted in post office red,conforming to is 884 complete with the following as required. a 20 mm nominal internal dia water hose thermoplastic textile reinforced type 2 as per is 12585 b 20 mm nominal internal dia gun metal globe valve and nozzle. c drum and brackets for fixing the equipmets on wall. d connections from riser with 25 mm dia stop gun metal valve and m.s. pipe and socket. 30 mtrs, supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required. gun meta, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 2 way 100 mm dia m.s. pipe, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 4 way 150 mm dia m.s. pipe, providing, installation, testing and commissioning of c.i flanged swing type foot valve isi marked of following sizes confirming to is 4038 complete with all acessories complete etc as required.200 mm dia, supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required., providing and fixing of pressure switch in m.s. pipe line including connection etc. as required., providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. as required., providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required. 150 mm dia, supplying and fixing of hose cabinet of size 750x mm x 600 mm x 250 mm made of 2 mm thick ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 nos . 15 mtr. long hose pipe, 1 no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required., cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 2 4 1 cement 2 coarse sand 4 graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof., sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 4 core 16 sqmm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988 . 3.5 core 25 sq. mm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 3.5 core x 70 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 35 sq. mm and upto 95 sq. mm clamped with 25 mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 185 sq. mm and upto 400 sq. mm clamped with 40mm and 3mm ms flat clamp, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq. mm clamped with 1mm thick saddle., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 35 sq. mm and upto 95 sq. mm clamped with 25mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 185 sq. mm and upto 400 sq. mm clamped with 40mm 3mm ms flat clamp, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.mm above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 4 core 16 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 25 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 70 sq. mm size 38mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 300 sq. mm size 70mm, supplying and laying of 2core 1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring and frls/hffr outer sheath complete as required., supplying and installaton following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5 percent, in convenient sections, joined with connectors, suspended from the ceiling with two numbers ms/gi suspenders including base of suitable size ms/gi angle, bolts and nuts, painting suspenders, fastener etc as required. 100 mm wide , 50 mm depth , 1.6 mm thickness, earthing with g.i. earth plate 600 mm length x 600 width and 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip on surface or in recess for connections etc. as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., providing and fixing following sizes g.i. pipes complete with g.i. fittings including trenching and refilling etc. 80 mm dia nominal bore

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16898313
Location : new delhi , delhi
Source : GEM Tenders
corrigendum tender for repair and maintenance of internal and external installation incl supply of spares at old area sap manpower , amc of 1.5 tr window type ac , amc of 1.5 or 2.0 tr split type ac , amc of 2.0 or 3.0 tr cassette or tower type ac , amc of 60 or 80 ltrs. water cooler with inbuilt water purification , amc of 60 or 120 ltrs. water cooler with inbuilt water purification , amc of 150 or 150 ltrs. water cooler with inbuilt water purification , 13mm thick closed cell elastomeric nitrile rubber or expanded polythene , rigid pvc piping , fuel cost for 650 kva dg sets , acmc of fire alarm and detection system , servicing of desert cooler , providing and fixing wood wool pads , spray painting of desert cooler or room coolers , spray painting of feeder pillers and distribution panels , providing and replacement of 2 inch gi b class pipe , providing and replacement of 3 inch gi b class pipe , rewinding of the ceiling fan, exhaust fan, wall fan , rewinding of the desert cooler fan motor , rewinding of the medium weight ceiling fan , rewinding of 450mm to 600mm exhaust fan , rewinding and repairing of 1 hp single phase mono block pump motor , rewinding and repairing of 2 hp single phase submersible pump motor , rewinding and repairing of 2 hp three phase mono block pump set , rewinding and repairing of 5 hp three phase submersible pump motor , rewinding and repairing of 5 hp three phase rain water pump motor , rewinding and repairing of 12.5 hp three phase submersible sewage pump motor , labour charges for lifting, dismantling of submersible or sewage motor- pump set , painting of 9 mtr. pole , detection of lt cable fault , 5 amp switch-piano type , 20 amp switch-piano type , 6 or 16 amp uni socket-piano type , 6 or 16 amp uni socket-modular type , 20 amp switch-modular type , 5 and 6 amp plug top , 15 and 16 amp plug top , 20 and 10 amp uni switch socket combined , 100w mini fan regulator rotary step type , desert cooler motor pump set 18w, 1.5m head , 40 amp dp 10ka c-series mcb , 63 amp dp 10ka c-series mcb , 40 amp tpn 10ka c-series mcb , 63 amp tpn 10ka c-series mcb , 06-32 amp sp 10ka c-series mcb , 20amp 230v spn industrial type metal clad plug top , 20amp 230v spn industrial type metal clad socket , 1.5 sqmm 3 core of copper conductor , 2 core having 1.5sqmm. of copper conductor , 3 core having 2.5sqmm. copper conductor , 1.5 sqmm frlsh pvc copper conductor , 2.5 sqmm frlsh pvc copper conductor , 4.0 sqmm frlsh pvc copper conductor , 6.0 sqmm frlsh pvc copper conductor , 3x4sqmm cu. submersible flat cable , 12 volt, 180 ah storage lead acid battery , 108 litre capacity m. s. body powder coated sliding 3 rack hot case , distilled battery water suitable for top-up of electrolyte level in battery , capacitor 1.20 mfd , capacitor 2.25 mfd , self adhesive ht insulation tape , self adhesive pvc insulating tape , dol starter 7.5 hp , electronic remote bell with one no. remote switch , pvc gang box for the 1 no. 5 amp switch. , pvc gang box for the 2 no. 5 amp switch , pvc gang box for the 1 no. 5 amp switch and 1 no. 5 amp socket , pvc gang box for the 2 no. 5 amp switch and 1 no. 5 amp socket , supply of 6 or 16 amp ss combine with shutter , 20 mm pvc channel , 25 mm pvc channel , 32 mm pvc channel , single phase energy meter , electric kettles 1.2 litre , ding dong bell , rechargeable torch , capacitor 4.0 mfd , desert cooler motor pump set , analogue addressable multi criteria detectors , addressable control module or relay module , addressable manual call point , addressable hooter cum strobe , fault isolator module , response indicators for all, detailed boq sh-i, item no. 1.00 (attached in tender documents), detailed boq sh-i, item no. 2.00 (attached in tender documents), detailed boq sh-i, item no. 3.00 (attached in tender documents), detailed boq sh-i, item no. 4.00 (attached in tender documents), detailed boq sh-i, item no. 5.00 (attached in tender documents), detailed boq sh-i, item no. 6.00 (attached in tender documents), detailed boq sh-i, item no. 7.00 (attached in tender documents), detailed boq sh-i, item no. 8.00 (attached in tender documents), detailed boq sh-i, item no. 9.00 (attached in tender documents), detailed boq sh-i, item no. 10.00 (attached in tender documents), detailed boq sh-i, detailed boq item no. 11.01 (attached in tender documents), detailed boq sh-i, item no. 12 (a) (attached in tender documents), detailed boq sh-i, item no. 12 (b) (attached in tender documents), detailed boq sh-i, item no. 12 (c) (attached in tender documents), detailed boq sh-ii, item no. 1.00 (attached in tender documents), detailed boq sh-ii, item no. 2.00 (attached in tender documents), detailed boq sh-ii, item no. 3.00 (attached in tender documents), detailed boq sh-ii, item no. 4.00 (attached in tender documents), detailed boq sh-ii, item no. 5 (a) (attached in tender documents), detailed boq sh-ii, item no. 5 (b) (attached in tender documents), detailed boq sh-ii, item no. 6 (a) (attached in tender documents), detailed boq sh-ii, item no. 6 (b) (attached in tender documents), detailed boq sh-ii, item no. 6 (c) (attached in tender documents), detailed boq sh-ii, item no. 6 (d) (attached in tender documents), detailed boq sh-ii, item no. 7 (a) (attached in tender documents), detailed boq sh-ii, item no. 7 (b) (attached in tender documents), detailed boq sh-ii, item no. 7 (c) (attached in tender documents), detailed boq sh-ii, item no. 7 (d) (attached in tender documents), detailed boq sh-ii, item no. 7 (e) (attached in tender documents), detailed boq sh-ii, item no. 7 (f) (attached in tender documents), detailed boq sh-ii, item no. 8.00 (attached in tender documents), detailed boq sh-ii, item no. 9.00 (attached in tender documents), detailed boq sh-ii, item no. 10.00 (attached in tender documents), detailed boq sh-iii, item no. 1.00 (attached in tender documents), detailed boq sh-iii, item no. 2.00 (attached in tender documents), detailed boq sh-iii, item no. 3.00 (attached in tender documents), detailed boq sh-iii, item no. 4.00 (attached in tender documents), detailed boq sh-iii, item no. 5.00 (attached in tender documents), detailed boq sh-iii, item no. 6.00 (attached in tender documents), detailed boq sh-iii, item no. 7.00 (attached in tender documents), detailed boq sh-iii, item no. 8.00 (attached in tender documents), detailed boq sh-iii, item no. 9.00 (attached in tender documents), detailed boq sh-iii, item no. 10.00 (attached in tender documents), detailed boq sh-iii, item no. 11.00 (attached in tender documents), detailed boq sh-iii, item no. 12.00 (attached in tender documents), detailed boq sh-iii, item no. 13.00 (attached in tender documents), detailed boq sh-iii, item no. 14.00 (attached in tender documents), detailed boq sh-iii, item no. 15.00 (attached in tender documents), detailed boq sh-iii, item no. 16.00 (attached in tender documents), detailed boq sh-iii, item no. 17.00 (attached in tender documents), detailed boq sh-iii, item no. 18.00 (attached in tender documents), detailed boq sh-iii, item no. 19.00 (attached in tender documents), detailed boq sh-iii, item no. 20.00 (attached in tender documents), detailed boq sh-iii, item no. 21.00 (attached in tender documents), detailed boq sh-iii, item no. 22.00 (attached in tender documents), detailed boq sh-iii, item no. 23.00 (attached in tender documents), detailed boq sh-iii, item no. 24.00 (attached in tender documents), detailed boq sh-iii, item no. 25.00 (attached in tender documents), detailed boq sh-iii, item no. 26 (attached in tender documents), detailed boq sh-iii, item no. 27 (attached in tender documents), detailed boq sh-iii, item no. 28 (attached in tender documents), detailed boq sh-iii, item no. 29 (attached in tender documents), detailed boq sh-iii, item no. 30 (attached in tender documents), detailed boq sh-iii, item no. 31 (attached in tender documents), detailed boq sh-iii, item no. 32 (attached in tender documents), detailed boq sh-iii, item no. 33 (attached in tender documents), detailed boq sh-iii, item no. 34 (attached in tender documents), detailed boq sh-iii, item no. 35 (i) (attached in tender documents), detailed boq sh-iii, item no. 35 (ii) (attached in tender documents), detailed boq sh-iii, item no. 35 (iii) (attached in tender documents), detailed boq sh-iii, item no. 35 (iv) (attached in tender documents), detailed boq sh-iii, item no. 36 (attached in tender documents), detailed boq sh-iii, item no. 37 (i) (attached in tender documents), detailed boq sh-iii, item no. 37 (ii) (attached in tender documents), detailed boq sh-iii, item no. 37 (iii) (attached in tender documents), detailed boq sh-iii, item no. 38.00 (attached in tender documents), detailed boq sh-iii, item no. 39.00 (attached in tender documents), detailed boq sh-iii, item no. 40.00 (attached in tender documents), detailed boq sh-iii, item no. 41.00 (attached in tender documents), detailed boq sh-iii, item no. 42.00 (attached in tender documents), detailed boq sh-iii, item no. 43.00 (attached in tender documents), detailed boq sh-iii, item no. 44.00 (attached in tender documents), detailed boq sh-iii, item no. 45.00 (attached in tender documents), detailed boq sh-iii, item no. 46.00 (attached in tender documents), detailed boq sh-iii, item no. 47.00 (attached in tender documents), detailed boq sh-iii, item no. 48.00 (attached in tender documents), detailed boq sh-iii, item no. 49.00 (attached in tender documents), detailed boq sh-iii, item no. 50.00 (attached in tender documents), detailed boq sh-iv, item no. 1.00 (attached in tender documents)
T18 Ref No : 17170274
Location : mumbai , maharashtra
Source : GEM Tenders
tender for a. dismantling disposal and civil works - dismantling and disposal of existing facility , civil work - wall repair and repainting , b. clean room panel system walls ceiling and flooring - wall cladding - partition panel system , coving at wall-to-wall wall-to-ceiling and floor-to-wall junctions , ra return air riser at partition base , rcc beam and ceiling cladding - return air plenum areas , false ceiling , esd anti-static pvc vinyl flooring , double-glazed vision - view panels , double-glazed vision - view panels - count , c. doors - clean-room compatible doors general - equipment movement , emergency exit door , face-biometric access control system at main entry , d. lighting and fixtures - clean-room grade led light fixtures , e. hvac system - ahu - treated fresh air tfa unit - supply installation testing and commissioning , ductwork - gi-aluminium- insulated- clean- room compatible , terminal hepa fan filter units -ffu , exhaust air system - chemical room , f. electrical- power- gas and plumbing services - electrical switches - 16-5a- wall-mounted , three-phase power connection points , wiring and fixtures , power backup - dedicated ups port , grounding system - copper strip , gas line - commercial nitrogen -n2 , gas line - compressed air , gas line - blank- spare line , water chiller inlet and outlet piping , process chilled water -pcw- piping network , ss316 ep tubing for gases with fittings , user utility points -water- gas- air- with fittings , g. building management system -bms- bms - central monitoring station , direct digital control -ddc- panel , field and room sensors with cabling , bms integration- programming and validation , h. electrification -distribution and luminaires- distribution boards -lighting- power- ups-emergency , cable management system , wires- cables- lighting- power- lan and communication , switch-sockets and mcbs , clean-room bottom-accessible led luminaires , led luminaires - grey- plenum areas , i. safety and surveillance systems - smoke detection system , electronic surveillance -cctv- system , biometric access control system , j. furniture and fixtures - air shower -if required , cross-over bench with shoe rack underneath , dressing cupboard , dry nitrogen and water gun , esd-compatible work table , ss stools , clean-room compatible chairs , emergency eye wash cum safety shower , shoe cover dispenser , k. utility systems - air curtain at clean room entry , motion sensor cctv cabling , fire alarm and smoke detector relocation , l. post-installation testing- validation and certification - clean room - hvac validation and performance qualification, renovation, the detailed specifications are mentioned in the atc documents.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 17333788
Location : tiruchendur , tamil nadu
Source : GEM Tenders
tender for operation and maintenance of electrical and mechanical installations ref atc pg.no soq 1 to 6 , items under electrical and mechanical dsr 2025 as per requirement ref atc pg.no soq 1 to 6 , installation of ci housing box ref atc pg.no soq 1 to 6 , laying of hdpe pipe upto 63mm dia in ground ref atc pg.no soq 1 to 6 , drawing of agl cables of 6 or 16sqmm cable ref atc pg.no soq 1 to 6 , annual servicing of 22kv 3 nos of ht breakers vcb ref atc pg.no soq 1 to 6 , annual servicing of 13 nos of l and t acbs ref atc pg.no soq 1 to 6 , main contact assembly fixed and moving for 1600a omega model acbs ref atc pg.no soq 1 to 6 , main contact assembly fixed and moving for 1250a omega model acbs ref atc pg.no soq 1 to 6 , shunt release operating voltage of 240v for omega model acbs ref atc pg.no soq 1 to 6 , closing coil 240v for l and t make omega model acb ref atc pg.no soq 1 to 6 , electrical charging device for l and t make omega model acb ref atc pg.no soq 1 to 6 , cradle facia for 1250a l and t make omega model acb ref atc ref atc pg.no soq 1 to 6 , spring charging handle l and t make omega model acb ref atc ref atc pg.no soq 1 to 6 , front facia for 1250a l and t make omega model acb ref atc ref atc pg.no soq 1 to 6 , frame 1, 4p main mechanism for 1250a l and t make omega model acb ref atc pg.no soq 1 to 6 , base plate assembly frame 4p for 1250a l and t make omega model acb ref atc pg.no soq 1 to 6 , under voltage release 415v for l and t make omega model acb ref atc pg.no soq 1 to 6 , annual calibration of 1 no clinometer and 1 no angle setting tools ref atc pg.no soq 1 to 6 , annual calibration of8 nos over current relay and earth fault relay ref atc pg.no soq 1 to 6 , annual calibration of 3 nos feeder protection relay ref atc pg.no soq 1 to 6 , conducting photometric field test of airfield ground lighting ref atc pg.no soq 1 to 6 , servicing and repairing of 16 mtr high mast pole ref atc pg.no soq 1 to 6 , servicing and repairing of 20 mtr high mast pole ref atc pg.no soq 1 to 6 , servicing and repairing of 30 mtr high mast pole ref atc pg.no soq 1 to 6 , supply of 6 corex 2 sqmm epr insulated copper cable ref atc pg.no soq 1 to 6 , supply of 5 core x 4 sqmm epr insulated copper cable ref atc pg.no soq 1 to 6 , supply of 6mm dia ss wire rope ss 304 7 x 19 ref atc pg.no soq 1 to 6 , repairing of high mast motor gear and winch assembly ref atc pg.no soq 1 to 6 , providing decorative lighting at terminal building garden etc ref atc pg.no soq 1 to 6 , extra for additional days for providing decorative lighting ref atc pg.no soq 1 to 6 , painting of electrical ht or lt panels with synthetic enamel paint ref atc pg.no soq 1 to 6 , painting of electrical ht or lt panels with epoxy primer ref atc pg.no soq 1 to 6 , painting of existing runway edge lights turn pad taxiway light ref atc pg.no soq 1 to 6 , painting of existing elevated approach lights ref atc pg.no soq 1 to 6 , numbering of agl light fixtures ref atc pg.no soq 1 to 6 , hiring of electrical and diesel operated 2 hp pumps ref atc pg.no soq 1 to 6 , hiring of electrical and diesel operated 3 hp pumps ref atc pg.no soq 1 to 6 , hiring of electrical and diesel operated 5 hp pumps ref atc pg.no soq 1 to 6 , hiring of hydraulic telescopic boom mobile crane ref atc pg.no soq 1 to 6 , hiring of wheel mounted hydraulic backehoe loader ref atc pg.no soq 1 to 6 , hiring of unskilled labours as per requirement ref atc pg.no soq 1 to 6, amc of airfield ground lighting, job contract for operation, preventive and breakdown maintenance of various electrical and mechanical installations, such as airport ground lighting, old power house, nav-aids and ancillary building, fire detection and alarm system at thoothukudi airport as detailed on the tender document on round the clock basis / as per need basis in line with the requirements indicated in the tender document and as required including providing tools and tackles, consumables, annual calibration of measuring instruments complete etc as detailed in the special conditions/technical specification of the contract., execution of items of schedule of rates e and m cpwd dsr-2025 as and when required for attending breakdowns, repair and maintenance and upkeep of internal and external electrical installations at different locations of thoothukudi airport as per direction of e-i-c. the bidder shall quote percentage (percentage) above / below the dsr 2025 rates in the form of multiplication factor. i.e. (for eg - if the bidder desires to quote 5percentage above on dsr 2025 rates, the rate column shall be filled as 1.05 and 5percentage below, the rate column shall be filled as 0.95). (note dsr-2025 is inclusive of gst)., installation of ci housing box along with cover plate of size 330 mm dia and depth up to 450 mm as per drawing i/c excavation of hard rock/pavement of all types/ concrete/bitumen etc. and all kinds of soil to the required depth, as per specifications, refilling the side surface, sloping and making good the same as original, providing cement concrete foundation of ratio 136 ( 1 cement, 3. coarse sand and 6 graded stone of 40 mm nominal size) and thickness of concrete at 75 mm in all sides i/c bottom dressing of earth, with brick and finishing with 13 mm thick cement plaster of ratio 13 on exposed surface and neat cement finishing on top etc. as required., laying of one number hdpe /pvc pipe upto 63mm dia direct in ground upto depth of 80cm including excauation and refilling, leveling etc.,, drawing of agl cables of 6/16 sq.mm size of cable in hdpe/gi/hume pipe, servicing of 22kv, 3 nos of ht breakers (vcb) (abb make model vd4/w 36.12.32, 36kv,1250a vcb) provided at various power houses/substations, by deploying authorized service personnel of manufacturer / service dealer / specialized service engineers experienced in similar nature of work, including drawing out of the vcb, opening the same, inspection, servicing, cleaning of contact surfaces, overhauling of operating mechanism, lubrication of moving parts, cleaning of cts and measuring of contact resistance, meggering, testing of on-off time, testing and of operation etc. as required. ( servicing of three breaker is considered as one job), annual inspection /overhauling/servicing of 13 nos acbs of l andt make of various capacities (acbs make l andt,model omega ( u-power ) fp, 2000a-3 nos, 1250 a-10 nos ) provided in the various lt panels at old powerhouses/substations by deploying authorised service personnel of manufacturer/service dealer/specialised agencies experienced in servicing of acbs including cleaning of acbs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, checking of uv coils, trip circuits, checking of control circuits, replacement of defective components and spares supplied by aai, testing and commissioning etc as required., main contact assembly (fixed moving) for 1600a acbs, main contact assembly (fixed and moving) for 1250a acbs, shunt release suitable for operating voltage of 240v for l and t make omega model acb, closing coil 240v for l and t make omega model acb, electrical charging device for l and t make omega model acb, cradle facia for 1250a l and t make omega model acb, spring charging handle l and t make omega model acb, front facia for 1250a l and t make omega model acb, frame 1, 4p main mechanism for 1250a l and t make omega model acb, base plate assembly frame 4p for 1250a l and t make omega model acb, under voltage release 415v for l and t make omega model acb, annual calibration of 1 no clinometer (model pro3600) and 1 no of approach light fittings angle setting tool from oem (m/s vardhaman pvt. ltd., delhi), including transportation, calibration certificate, and all incidental charges. (calibration of 2 nos of meters is consider as one job ), annual calibration of 8 nos of over current relay and earth fault relay (make c ands, model no. ec2), including transportation, calibration certificate, testing, and all incidental charges. (calibration of 8 nos of relay is consider as one job ), annual calibration of 3 nos of feeder protection relays (make c ands model no. cse pro f-300) ), including transportation, testing,calibration certificate, and all incidental charges. (calibration of 3 nos of relay is consider as one job ), conducting photometric field test of airfield ground lighting for measurement of intensity, beam spread and orientation (4cs - configuration colour,candala and coverage )as per the requirement of car/icao(annexure-14)using a vehicle-mounted or suitable photometric calibration system, including all tools and plants such as vehicle, high lift for elevated approach lights and trained manpower etc as required and submission of test reports., servicing and repairing of high mast poles of the following sizes , including dismantling,lowering and raising of the mast with a crane of suitable capacity, cleaning, greasing/oiling of moving parts, replacement of damaged parts excluding motors gear assembly , testing, and making the high mast system functional, complete as directed by the engineer-in-charge. (the rate is exclusive of supply of cable and rope .) 16mtrs high mast make dyaus poles, servicing and repairing of high mast poles of the following sizes , including dismantling,lowering and raising of the mast with a crane of suitable capacity, cleaning, greasing/oiling of moving parts, replacement of damaged parts excluding motors gear assembly , testing, and making the high mast system functional, complete as directed by the engineer-in-charge. (the rate is exclusive of supply of cable and rope .) servicing and repaiting of 20 mtr high mast pole ref atc, servicing and repairing of high mast poles of the following sizes , including dismantling,lowering and raising of the mast with a crane of suitable capacity, cleaning, greasing/oiling of moving parts, replacement of damaged parts excluding motors gear assembly , testing, and making the high mast system functional, complete as directed by the engineer-in-charge. (the rate is exclusive of supply of cable and rope .) servicing and repaiting of 30 mtr high mast pole, supply of 6 core x 2.5sqm epr insulated ,frls pvc sheated , flexible copper cable of 1.1kv grade, supply of 5corex 4sq.mm epr insulated ,frls pvc sheated , flexible copper cable of 1.1kv grade, supply of 6 mm dia ss wire rope ss 304 7 19 construction suitable for high mast lighting systems, including unloading, and all incidental charges etc. as required, repairing of high mast motor gear and winch assembly, including dismantling at site, safe transportation to the repair workshop, inspection, repair replacement of defective components reassembly, transportation back to site, re installation, alignment, testing, commissioning, and satisfactory operation of the high mast lighting system., hire charges for providing coloured led serial lighting sets (minimum 500 nos and each consisting of minimum 50 nos of led lamps), 50 nos of 150wattage rgb led par light etc for decorating terminal building, technical building, city side areas etc during events or occasions like independence day / republic day /other festive occasions as per the direction of aai including all other related accessories like circuit / sub main wiring along with earth wire from nearest supply point as required and maintaining the same by deploying suitable manpower with tools, tackles, ladders etc on round the clock etc complete as per actual site requirements, removing and taking back the same after completion of occasion period. (one event is taken as 3days,which will treated as 1 job), extra for each additional day of illumination with same lighting as previous items, painting of electrical ht/lt panels (indoor/outdoor types), earth pit covers etc installed at various locations of thoothukudi airport, with two or more coats of spray painting with synthetic enamel paint of approved brand (as per list of approved makes annex-lam) to give an even shade, including cleaning of surface etc, applying one coat primer of required color as per the instruction of engineer-in-charge complete as required., painting of electrical ht/lt panels (indoor/outdoor types), installed at various locations of thoothukudi airport, with one coat of spray painting with epoxy primer of approved brand(as per list of approved makes annex-lam) to give an even shade, including cleaning of surface using scrubber/wet/dry sandpaper etc, as per the instruction of engineer-in-charge complete as required., painting of existing runway edge lights,turn pad/ taxiway light with base plate. cleaning the existing runway edge light fittings by removing dust, dirt, rust, grease, and loose paint. surface preparation shall be carried out two coats of aviation yellow, weather-resistant epoxy paint of the approved colour. care shall be taken to ensure that the light lens, optical components, gaskets, and identification markings are not painted or damaged. the work shall include masking, touch-up, cleaning of the work area, and restoration of the fitting to its original operating condition, complete in all respects as directed by the engineer-in-charge. (runway elevated edge light -193 nos, taxiway/turn pad edge light -258 nos ), painting of existing elevated approach lights,cleaning the existing approach light fittings by removing dust, dirt, rust, grease, and loose paint. surface preparation shall be carried out two coats of aviation yellow, weather-resistant epoxy paint of the approved colour (as per list of approved makes annex-lam). care shall be taken to ensure that the light lens, optical components, gaskets, and identification markings are not painted or damaged. the work shall include masking, touch-up, cleaning of the work area, and restoration of the fitting to its original operating condition including working arrangements in fitting at height upto 11 mtr suitable for the cat-i and sapl approach lights as installed in the thoothukudi airport, complete in all respects as directed by the engineer-in-charge., numbering of agl light fixtures (runway circuits, taxiways, approach lights, and threshold lights) shall be carried out with yellow letters on a black background using floor guard paint and stencil, as per the directions of the engineering in-charge, hiring of following rating of electrical/diesel operated submersible / monoblock / selfprimed pumps with suction and delivery hose including transportation and fuels charges , labour charges etc as required 2hp pump, hiring of following rating of electrical/diesel operated submersible / monoblock / selfprimed pumps with suction and delivery hose including transportation and fuels charges , labour charges etc as required 3hp pump, hiring of following rating of electrical/diesel operated submersible / monoblock / selfprimed pumps with suction and delivery hose including transportation and fuels charges , labour charges etc as required 5hp pump, hiring of hydraulic telescopic boom mobile crane (minimum 32 m boom with fly jib) on hourly basis, complete with licensed operator, valid third-party inspection (tpi) safety certificate, helper/rigger, fuel (hsd), lubricants, mobilization and demobilization, maintenance, insurance, all statutory compliances, airport entry, temporary driver pass, vehicle pass, and all other incidental charges, complete as directed by the engineer-in-charge., hiring of wheel-mounted hydraulic backhoe loader (jcb 3dx or equivalent) on hourly basis for excavation, site clearance, loading, unloading, backfilling, and allied works, complete with licensed operator, fuel (hsd), lubricants, maintenance, insurance, mobilization/demobilization, airport entry temporary driver pass, vehicle pass, and all other statutory permissions, taxes, and incidental charges, complete as directed by the engineer-in-charge., hiring of unskilled labour , providing and deploying unskilled labour on an as-and-when-required call basis to meet fluctuating site requirements, within 24 hours of written or verbal notice by the engineer-in-charge. the labour shall be deployed for manual tasks including site cleaning, material handling, and construction assistance. one quantity is considered on deploying one man power for 8 hours.
T18 Ref No : 17398451
Location : mumbai , maharashtra
Source : GEM Tenders
Corrigendum Tender For A. DISMANTLING DISPOSAL AND CIVIL WORKS - Dismantling and disposal of existing facility , Civil work - wall repair and repainting , B. CLEAN ROOM PANEL SYSTEM WALLS CEILING AND FLOORING - Wall cladding - partition panel system , Coving at wall-to-wall wall-to-ceiling and floor-to-wall junctions , RA Return Air riser at partition base , RCC beam and ceiling cladding - Return Air Plenum areas , False ceiling , ESD anti-static PVC vinyl flooring , Double-glazed vision - view panels , Double-glazed vision - view panels - count , C. DOORS - Clean-room compatible doors general - equipment movement , Emergency exit door , Face-biometric access control system at main entry , D. LIGHTING and FIXTURES - Clean-room grade LED light fixtures , E. HVAC SYSTEM - AHU - Treated Fresh Air TFA unit - supply installation testing and commissioning , Ductwork - GI-Aluminium- insulated- clean- room compatible , Terminal HEPA Fan Filter Units -FFU , Exhaust air system - chemical room , F. ELECTRICAL- POWER- GAS and PLUMBING SERVICES - Electrical switches - 16-5A- wall-mounted , Three-phase power connection points , Wiring and fixtures , Power backup - dedicated UPS port , Grounding system - copper strip , Gas line - Commercial Nitrogen -N2 , Gas line - Compressed air , Gas line - Blank- spare line , Water chiller inlet and outlet piping , Process Chilled Water -PCW- piping network , SS316 EP tubing for gases with fittings , User utility points -water- gas- air- with fittings , G. BUILDING MANAGEMENT SYSTEM -BMS- BMS - central monitoring station , Direct Digital Control -DDC- panel , Field and room sensors with cabling , BMS integration- programming and validation , H. ELECTRIFICATION -DISTRIBUTION and LUMINAIRES- Distribution boards -lighting- power- UPS-emergency , Cable management system , Wires- cables- lighting- power- LAN and communication , Switch-sockets and MCBs , Clean-room bottom-accessible LED luminaires , LED luminaires - grey- plenum areas , I. SAFETY and SURVEILLANCE SYSTEMS - Smoke detection system , Electronic surveillance -CCTV- system , Biometric access control system , J. FURNITURE and FIXTURES - Air shower -if required , Cross-over bench with shoe rack underneath , Dressing cupboard , Dry nitrogen and water gun , ESD-compatible work table , SS stools , Clean-room compatible chairs , Emergency eye wash cum safety shower , Shoe cover dispenser , K. UTILITY SYSTEMS - Air curtain at clean room entry , Motion sensor CCTV cabling , Fire alarm and smoke detector relocation , L. POST-INSTALLATION TESTING- VALIDATION and CERTIFICATION - Clean room - HVAC validation and performance qualification, RENOVATION, The detailed specifications are mentioned in the ATC documents.

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Fire Alarm Control Panel Repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Fire Alarm Control Panel Repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Fire Alarm Control Panel Repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Fire Alarm Control Panel Repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Fire Alarm Control Panel Repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Fire Alarm Control Panel Repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Fire Alarm Control Panel Repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Fire Alarm Control Panel Repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Fire Alarm Control Panel Repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Fire Alarm Control Panel Repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Fire Alarm Control Panel Repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Fire Alarm Control Panel Repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Fire Alarm Control Panel Repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Fire Alarm Control Panel Repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Fire Alarm Control Panel Repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Fire Alarm Control Panel Repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Fire Alarm Control Panel Repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Fire Alarm Control Panel Repair is declared L1 and is generally awarded the contract