Latest Tender Detail from canara bank for the tender for supply installation testing and commissioning vrf outdoor unit of 12 hp capacity , supply installation testing and commissioning vrf outdoor unit of 18 hp capacity , supply installation testing and commissioning of vrf indoor units , supply of individual cassette unit , lifting and shifting of outdoor unit , lifting and shifting of vrf indoor units , control cabling , refrigerant piping , drain piping , power cable , plug top , pressure testing and gas topup , fabrication works for odus , testing, installation and commission of individual cassette ac unit , refrigerant piping for individual cassette ac unit , interconnecting control cables for individual cassette ac unit , drain piping for individual cassette ac unit , stand for individual cassette ac unit, vrf ac for canara bank pune circle office, supply, transportation, testing and commissioning of 12 hp (side dischrge cooling only) aircooled type vrv/vrf minimum of one/two/three/four outdoor units comprising of dc scroll/dc twin rotary, inverter driven compressor, air cooled condenser operation on 410a refrigerant gas and on 415v, 50hz, 3 phase ac supply. the multiple compressors offered shall have independent refrigerant circuit, also shall cut off automatically in part load condition. the unit shall have microprocessor controls. the out door units shall be installed on the space alloted in the drawings and scope shall include all supports for the out door units. units shall be factory assembled and only the refrigerant piping shall be carriedout at the site. the noise levels for the out door unit shall be less than 70db(a). the price shall include the vibration isolator, all types of outdoor units connection piping (t- shape and y-shape) kits, required number of outdoor refnurt joints, in pair excluding refrigerant pipe and refregirent gas for the mentioned capacity., supply, transportation, testing and commissioning of 18 hp (top dischrge cooling only) aircooled type vrv/vrf minimum of one/two/three/four outdoor units comprising of dc scroll/dc twin rotary, inverter driven compressor, air cooled condenser operation on 410a refrigerant gas and on 415v, 50hz, 3 phase ac supply. the multiple compressors offered shall have independent refrigerant circuit, also shall cut off automatically in part load condition. the unit shall have microprocessor controls. the out door units shall be installed on the space alloted in the drawings and scope shall include all supports for the out door units. units shall be factory assembled and only the refrigerant piping shall be carriedout at the site. the noise levels for the out door unit shall be less than 70db(a). the price shall include the vibration isolator, all types of outdoor units connection piping (t- shape and y-shape) kits, required number of outdoor refnurt joints, in pair excluding refrigerant pipe and refregirent gas for the mentioned capacity., supply of 1.30 tr round flow vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 1.67 tr round flow vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 2.10 tr round flow vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 2.67 tr round flow vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 0.80 tr round flow compact vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 1.67 tr one way flow vrf cassette unit type indoor units comprising with pre-filter, fan section with low noise fan 3/4 multi speed motor, coil section with dx coil, outer cabinet, drain water lift-up mechanism, insulation, pipe connections etc. of various capacities as per specifications and drawings. panel size should be not more than 950mm square. the rate must include cost of providing wireless remote and required indoor refnurt joints, supply of 2.0 tr cassette type ac unit with copper evaporator coil having 4 way round air flow including all necessary fittings and mountings as specified by the manufacturer. min. 3 star or equivalent energy saving latest model inverter type of toshiba, mitsubhishi, hitachi, daikin, lg, bluestar, carrier, voltas with cordless remote controller with 9 mm thick nitrile rubber pipe insulation with fan and fan motor, machine control panel improved refrigerant joints., lifting, shifting, positioning and installation of 12hp vrf outdoor units from ground floor to terrace of building (g+4) or to the desired location as directed by employer, lifting, shifting, positioning and installation of 18hp vrf outdoor units from ground floor to terrace of building (g+4) or to the desired location as directed by employer, lifting, shifting, positioning of indoor units as mentioned above suitable for vrv/vrf system, from ground level to the desired location on the required floor of the building and their installation, testing and commissioning including providing necessary y joints, supply and installation of control cabling with copper conductor cable (2 core 0.75 sqmm ) with end termination for indoor units, hard copper refrigerant piping of required size for gas suction and liquid. the piping must be supported at every 1.75m with 300mm wide gi perforated cable trays in indoor ducts, shafts wherever required with proper supports, hangers from ceiling, wall as required at site and approved by consultant and duly insulated with closed cell elastomeric nitrile insulation of 19mm thick for pipes above 1 in. and 13mm thick for pipes below 1 in. as per requirement of machines. gi cover to be provided for cable tray on outdoor areas like open terrace and ducts to protect refrigerant piping and insulation. the quoted rates must include for core cutting, chipping, chasing and plastering the wall openings in cement 1 morter 6 of 15 mm thick finishing to line and level with sand facied finishing at all levels, including all leads and lifts, scaffolding, curing etc complete for copper pipe openings in all rooms etc., supply and erection of hard 32mm dia pvc condenseted drain piping for branch connections complete with 9mm thick nitrile insulated including support and wall opening. the piping system supported at every 1.75m with 300mm wide gi perforated cable tray in indoor ducts, shafts wherever required with proper supports, hangers from ceiling, wall as required at site and approved by consultant. gi cover to be provided for cable tray on outdoor areas like open terrace and ducts to protect piping. the quoted rates must include for core cutting, chipping, chasing and plastering the wall openings in cement (1) morter (6) of 15 mm thick finishing to line and level with sand facied finishing at all levels, including all leads and lifts, scaffolding, curing etc. complete for drain openings in all rooms etc., supply and erection of hard 50mm dia pvc condenseted drain piping for header line complete with 9mm thick nitrile insulated including support and wall opening. the piping system supported at every 1.75m with 300mm wide gi perforated cable tray in indoor ducts, shafts wherever required with proper supports, hangers from ceiling, wall as required at site and approved by consultant. gi cover to be provided for cable tray on outdoor areas like open terrace and ducts to protect refrigerant piping, insulation. the quoted rates must include for core cutting, chipping, chasing and plastering the wall openings in cement (1) morter (6) of 15 mm thick finishing to line and level with sand facied finishing at all levels, including all leads and lifts, scaffolding, curing etc. complete for drain openings in all rooms etc., supply and installation of flexible frlsh power cable with end termination for all idu units ( 2/3 rmt for each units ) ( 3 core x 1.5 sqmm ), supply installation testing and commissioning of 15a power plug top of approved make, vacuuming the system, gas topping up of r410a, pressure testing and commissioning of above system, outdoor flat form/stand work for mounting of outdoor units on terrace. if required, ductable units and angle supports to be provided with two red oxide with animal paint, fabrication work for wall hanging mounting stand for outdoor units. if required, ductable units and angle supports to be provided with two red oxide with animal paint, itc of individual 2.0 ton cassette ac unit and fittings duly insulated with 9 mm thick nitrile rubber pipe insulation with, fan and fan motor, machine control panel improved refrigerant joints, .air conditioners shall be fitted with hermetically sealed type suction cooled reciprocating or discharge cooled rotary compressor or scroll compressor. compressor unit operating on -410. all complete as per drawing, approval and instructions of the employer, supplying and laying of extra copper refrigerant piping with nitrile rubber pipe insulation, both of size as specified by the manufacturer suitable for 2.0 tr cassette ac from indoor to outdoor units., supplying and laying of extra electrical interconnecting control cables from indoor to outdoor of size as specified by the manufacturer suitable for 2.0 trcassette type ac., providing and fixing 32mm drain piping up to drain as directed by the engineer in charge with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc. complete job including cutting chiseling in walls, fixing with gi clamps,floor and making good of all chases/ cuts etc. and discharging the drain into a floor trap/ gully as per site conditions with insulation, both as specified by the manufacturer., providing and fixing, rigidly at desired location, powder coated readymade stands for odu of 2.0 ton cassette ac in pune, maharashtra,. Reference number 17356370. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.