tender for annual operation and maintenance of electrical and mechanical installations manpower , inspection, servicing and testing of 3 ph 11kv 400a ht vaccum circuit breaker vcb , servicing, testing, checking and replacement of defective parts or spares of 500 kva, 11 kv or 433 kv crompton make onan cooled transformer , servicing, checking and testing of the lt air circuit breakers up to 800 amp rating , inspection, servicing, calibration and testing of electrical metering and safety device including amp meter, volt meter, mfm and relays of ht and lt panels , dehydration and filtration of transformer oil of 11 kv or 433v, 500 kva onan transformer from specialized agency , supply of new transformer oil , rewinding of monobloc pumps of 1 hp capacity , rewinding of submersible pump of 0.5 hp capacity , rewinding of submersible pump of 5 hp incl lowering and lifting , rewinding of ceiling fan of all makes and models. , rewinding of exhaust fan of sweep upto 300mm of all makes and model , rewinding of wall fan of size up to 450mm.of all makes and model , spray painting of sheet metal enclosures, lt panels, feeder pillars, dg exhaust pipes or control panel , decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on independence day , decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on diwali , decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on republic day , decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on aai foundation day , painting of ht structure including fencing , comprehensive maintenance contract for automatic sliding door double leaf type , inspection, servicing and complete overhauling of 20 mts. bajaj make apron flood light high mast , execution of complete items from cpwd delhi schedule of rates 2025 electrical as and when required basis, annual operation and maintenance for the e and m installation at bhuj airport, annual operation and maintenance of electrical and mechanical installations, power house installations including ht panels, transformers, terminal building, dg sets, bhs system, operational area or apron, city side car parking area, aai residential colony, cisf barrack, rooftop solar plant, water supply pumps in three shifts on all working days as per specification and condition attached, attending to complaints or faults or breakdowns, ensuring serviceability and satisfactory working condition of the system, performing preventive maintenance, maintenance of records or documentation etc. as per the detailed specifications, terms and conditions covered under this contract, on all days including sundays and holidays and also as and when required basis. highly skilled 2, skilled 7, semi skilled 6, un skilled 5., inspection, servicing and testing of 3 ph 11kv 400a ht vaccum circuit breaker vcb panel make crompton greaves, model 12v x 12 xl as per recommended standards of oem and as specified in the scc including testing of connected cts and pts, wiring wherever as required, minor repairing works and replacement of defective parts or spares documenting the testing, submitting the same to aai etc compelete as required. the above activity shall be carried out through oem or authorized service dealer of oem etc. complete as required. 3 nos. vcbs x 2 year equalto 6 job, servicing, testing, checking and replacement of defective parts or spares of 500 kva, 11 kv or 433 kv crompton make onan cooled transformer including testing of wiring, minor repairing works as per recommended standard and submission of report complete as required through authorised service agency of oem or agency approved by engineer in charge. testing should include insulation resistance test, voltage ratio and tap continuity test, magnetic balance test, vector group test, accessories working etc. as required.
note if required, spares of transformer shall be arrange by agency for the replacement of the defective components or spares aai shall paid extra for the same. 2 nos. x 2 year equalto 4 job, servicing, checking and testing of the lt air circuit breakers up to 800 amp rating including testing of wiring of breaker and minor repairing works complete as required including documenting the testing as per recommended standards and as mentined in the scc through oem or authorised agency of oem followed with submission of test report to aai. make l and t, model cn cs 800 s. 8 nos. x 2 years equalto 16 job, inspection, servicing, calibration and testing of electrical metering and safety device including amp meter, volt meter, mfm and relays of ht and lt panels, performing relay construction of ordination of the relays, checking wiring, including submission of reports on the related calculations for relay setting etc. as required. the activity shall be carried out through the oem or authorized specialized agencies with appropriate licenses and experiences etc. as required.
a idmt relays 2oc and ef 7 nos and auxiliary and tripping relays type vaa21z98501fch 4 nos. and the total installed amp meter, volt meter, mfm details are as per tender document, dehydration and filtration of transformer oil of 11 kv or 433v, 500 kva onan transformer from specialized agency. the filtration of the oil is to be done as per relevant is or ie rule and the value of bdv, ph and acidity is to be checked and recorded before and after the filteration. the bdv value after filtration should be as per relevant is code or oem standard. the agency is required to arrange the filteration machine at site at his own cost etc as required. the timing of filteration has to be decided in consultation with engineer in charge keeping in veiw of operational requirement. app. qty of transformer oil equalto 420ltr. replacement of new silica gel is also included in this item, supply of new transformer oil complying with is 335 208 for toping up the transformer as required., rewinding of the 3 phase or single phase 50 hz ac electric motor pumps incl dismantling, transportation to workshop and back to site , of following capacity
monobloc pumps of 1 hp capacity, rewinding of the 3 phase or single phase 50 hz ac electric motor pumps incl dismantling, transportation to workshop and back to site , of following capacity
submersible pump of 0.5 hp capacity, rewinding of the 3 phase or single phase 50 hz ac electric motor pumps incl dismantling, transportation to workshop and back to site , of following capacity
submersible pump of 5 hp incl. lowering and lifting, rewinding of the following type fans incl dismantling, transportation to workshop and back to site.
ceiling fan of all makes and models., rewinding of the following type fans incl dismantling, transportation to workshop and back to site.
exhaust fan of sweep upto 300mm of all makes and model, rewinding of the following type fans incl dismantling, transportation to workshop and back to site.
wall fan of size up to 450mm.of all makes and model, spray painting of sheet metal enclosures or lt panels or feeder pillars or dg exhaust pipes or control panel with two coats of synthetic or enamel paint of grey or any other colour as approved by aai, including cleaning the surface , rewriting the identification of the circuit. the electrical accessories shall be covered and protected from dust during painting as required., decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on special occassions or nationally important days or festivals as per the requirements shown below.
a minimum no. of led serial lighting not less than 10000 led lights.
b rgb pattern lighting for pillars of terminal building 25 nos. rgb par lights shall be used
c pixel chaser light batten with minimum 12 colour combinations running linearly on the top of the building for a length of not more than 400 m.
independence day starting from 18.00 hrs on day before independence day to 06.00 hrs on the day after independence day each occasion in an year shall be treated as one job., decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on special occassions or nationally important days or festivals as per the requirements shown below.
a minimum no. of led serial lighting not less than 10000 led lights.
b rgb pattern lighting for pillars of terminal building 25 nos. rgb par lights shall be used
c pixel chaser light batten with minimum 12 colour combinations running linearly on the top of the building for a length of not more than 400 m.
diwali four days starting from 18.00 hrs. on day before diwali, diwali day, gujarati new year day and bhai dhooj day , till 06.00 hrs on day after bhai dhooj day each occasion in an year shall be treated as one job., decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on special occassions or nationally important days or festivals as per the requirements shown below.
a minimum no. of led serial lighting not less than 10000 led lights.
b rgb pattern lighting for pillars of terminal building 25 nos. rgb par lights shall be used
c pixel chaser light batten with minimum 12 colour combinations running linearly on the top of the building for a length of not more than 400 m.
republic day starting from 18.00 hrs on day before republic day to 06.00 hrs on the day after republic day each occasion in an year shall be treated as one job., decoration of terminal building, main gate facia with led serial lighting and rgb pattern lighting on special occassions or nationally important days or festivals as per the requirements shown below.
a minimum no. of led serial lighting not less than 10000 led lights.
b rgb pattern lighting for pillars of terminal building 25 nos. rgb par lights shall be used
c pixel chaser light batten with minimum 12 colour combinations running linearly on the top of the building for a length of not more than 400 m.
aai foundation day starting from 18.00 hrs on day before foundation day to 06.00 hrs on the day after foundation day, painting of ht structure including fencing approximate 6 sq.mtr. with two coats of aluminium or enamel paint including cleaning, scraping and applying approved steel primer where ever required similar to the existing colours and shade complete as required., comprehensive maintenance contract for automatic sliding door double leaf type for overall opening up to 3650 mm and clear passage height up to 2600 with dc motor , microcontroller , infrared sensor and safety light barriers including air curtain integrated with the automatic sliding door as per scc. make security technocrats
location 1 arrival area entry
location 2 arrival area exit
location 3 boarding gate 1
location 4 boarding gate 2
location 5 checkin area entry 1
location 6 checkin area entry 2, inspection, servicing and complete overhauling of 20 mts. bajaj make apron flood light high mast,wire rope, lantern carrage ,winch assembley ,tralining cable incl repairing, replacement of defective parts of winch assembly if required through oem or authorised service provider of oem, tightening of nut bolts of foundation , painting with anti corrosive paint , complete with testing and commissioning all as per site requirement., execution of complete items from cpwd delhi schedule of rates electrical 2025 as and when required basis. up to a ceiling limit of rs. 2,00,000.00 . the materials used for executing the dsr items shall be as per the preferred make list of aai, as enclosed with the tender document. please refer the clause 44 of the scc at page no scc 148 for the guideline for quoting the rate
the rate shall be quoted for this item as per examples given below
i if bidder wants to quote the rates at par with rates of dsr 2025 e and m, then bidder has to quote 1.00 in the rate column.
ii if bidder wants to quote the rate 10 percentage above on rate of dsr 2025 e and m, then bidder has to quote 1.10 in the rate column.
iii if bidder wants to quote the rate 10 percentage below on rate of dsr 2025 e and m, then bidder has to quote 0.90 in the rate column.