tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document.

Latest Tender Detail from chennai port trust for the tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document. in chennai, tamil nadu,. Reference number 16356653. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:16356653
Tender ID:GEM/2026/B/7821829
Tender Agency:chennai port trust
City:chennai
State:tamil nadu
Tender Related Keywords :
Description :
total quantity = 57 ----- evaluation method = item wise evaluation
T18 Ref No:16356653Tender Value:Refer Document
Tender ID:GEM/2026/B/7821829Tender EMD:Refer Document
Tender Agency:chennai port trustTender Fee:Refer Document
City:chennaiPublished Date:Jul 22, 2026
State:tamil naduDue Date:Aug 12, 2026
Tender Related Keywords :high frequency radio surgery unit, syringe infusion pump, bio safety cabinet, medical equipments, multipara monitor, led light source, cautery machine, safety cabinet, exhaust system, infusion pump, syringe pump, medical care, alarm system, power supply, light source, ecg machine, hepa filter, led light, ac power, batteryTender Opening Date:Aug 12, 2026
Description :total quantity = 57 ----- evaluation method = item wise evaluation

Get Complete Tender Documents to Participate

Tender NoticeBOQEligibilityEMD DetailsImportant Dates
We take all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Browse GeM Portal Tenders

This Government Tender has been Published  by Chennai Port Trust for work related to high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery in Chennai, Tamil Nadu. The Tender work is tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document.. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document., bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Chennai Port Trust usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Chennai , Tamil Nadu tender on a single page. Businesses involved in high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document. from Chennai, Tamil Nadu may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Chennai Port Trust in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for multipara monitor , ecg machine , bio safety cabinet , syringe pump , high frequency radio surgery unit - rf , mobile endoscopy unit, purchase of 6 medical equipments, multipara monitor - specificaitons - type of monitor - pre- configured, monitoring parameters - ecg ,hr,respiration rate, spo2, pulse rate nibp,temperature ,ibp length of time of full, disclosure of patient data in hr - greater than or equal to 24, length of time of trending in hr - greater than or equal to 72, number of leads of ecg - 5, ecg waveform number of leads display - 7, respiration rate measurement range 0- 150 bpm or more, spo2 measurement range 70 - 100 percentage, systolic blood pressure monitoring range 40 - 250 mmhg or more, diastolic blood pressure monitoring range 10 - 200 mmhg or more, type of probe - skin, number of channels for ibp - 2, sensor type - na, display size in inches - 12, traces of display - greater than 10 and user interface of display - touchscreen and rotary knob. refer schedule a of tender document., ecg machine - specifications - description of function - ecg machine is a primary equipment to record ecg signal in various configurations, 12 channels with interpretation is required for recording and analysing the waveforms with special software. it should have the optional facility to measure and display waveforms of 6 more ec of back and right chest region. general requirements - 1. the ecg machine should be able to acquire all 12 leads simultaneously for both adult and paediatric patients. 2. should have facility to interpret 12 lead and derive 6 more ecg of back - v7, v8 and 9 and right chest region - v3r, v4r, v5r. 3. must be able to display all 12 lead ecg and other data on bright colour backlit lcd with minimum 7 inch display. 4.should display all ecg waveforms patient information, heart rate, qrs mark, error message - 12 lead ecg display with print preview - qtc interval - hrv analysis, recording speed change option. 5. should be easy to operate, compact and lightweight not exceeding 5 kg including battery. 6. should have alpha-numeric keyboard for patient data entry. refer schedule a of tender document., bio safety cabinet - specifications- 1. class i is the most basic bio-safety cabinet that provide protection to the environment and the laboratory personnel. 2. it does not however provide protection to the product as the un-sterilised room air is drawn over the work surface. 3. class i bio-safety cabinets are typically used to either enclose specific equipment like centrifuge or for procedures like aerating cultures that might potentially generate aerosols. 4. bio-safety cabinets of this class are either ducted -connected to the building exhaust system- or unducted -re-circulating filtered exhaust back into the laboratory. 5. in the class i bio-safety cabinet, the room air is drawn in through the opening that also allows the entry of the operator arm during work. 6. the air inside the cabinet then takes the aerosol particles that may have been generated and moves it away from the operator toward the hepa filter. 7. the air moving out of the cabinet i thus, sterilised via the hepa filters before its discharge to the environment. 8. in this way, cabinet protect the operator and the environment from the aerosol but not the sample. refer schedule a of tender document., syringe pump - specifications- the syringe infusion pump provides uniform flow of fluid by precisely driving the plunger of a syringe down its barrel. it provides accurate and continuous flow rate for precise delivery of i.v. medication in critical medical care. i. operational requirements - l. the syringe pump should be programmable, user friendly, safe to use and should have battery backup and comprehensive alarm system. 2. demonstration of the equipment is a must. ii. technical specifications - 1 . flow rate programmable from 0.1 to 300 ml per hr or more in steps of 0.1 ml per hr with user selectable flow set rate option. save last infusion rate even when the ac power is switched off. 2.bolus rate should be programmable to 300 - 1200 ml per hr or more with infused volume display. reminder audio after every 0.5 ml delivered bolus. save last bolus rate even when the ac power is switched off. 3.display of drug name with a provision of memorizing names by the operator, 4.keep vein open -kvo must be available 1.0 ml per hr or set rate if lower than 1.0 ml. user should have choice to disable kvo whenever desired, etc. refer schedule a of tender document., high frequency radio surgery unit -rf, high frequency radio surgery unit -rf cautery, small cautery machine. specifications - operating frequency - 2 mega hertz frequency - 50 hz, electrodes - insulated , dimensions - 250 x 300 x 150 mm, weight - lesser than or equal to 7 kg, power supply - 230 volt, output power - 100 watt. refer schedule a of tender document., mobile endoscopy unit - mobile endoscopy unit-portable endoscopy unit. specification - integrated camera-led light source - 1. 1-3 inch lcd image sensor, 2. 19 mm endocarpler, 3. hi-portable led light source, 4. light weigh camera head with auto iris aperture and osd, 5. adjustable led brightness -off-mid-high display -1. 12-13 inch display size 2. resolution- 1024 x768p- 60 hz 3. lcd menu -brightness, sharpness, contrast, gamma. 4. composite video 5. osd function with key pad 6.portable carry case with safety lock. refer schedule a of tender document. issued by Chennai Port Trust for high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery related work in Chennai, Tamil Nadu? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery parameters and guide you on how to coordinate efficiently with the procurement team of Chennai Port Trust

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document. . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Chennai Port Trust.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document. in Tamil Nadu.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document.. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Chennai.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Chennai Port Trust

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery contracts, companies must prepare their core compliance documents. Vendors operating across Tamil Nadu must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality high frequency radio surgery unit,syringe infusion pump,bio safety cabinet,medical equipments,multipara monitor,led light source,cautery machine,safety cabinet,exhaust system,infusion pump,syringe pump,medical care,alarm system,power supply,light source,ecg machine,hepa filter,led light,ac power,battery solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Chennai region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document. by Chennai Port Trust

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document. within the Tamil Nadu jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for Tender For Multipara Monitor , Ecg Machine , Bio Safety Cabinet , Syringe Pump , High Frequency Radio Surgery Unit - Rf , Mobile Endoscopy Unit, Purchase Of 6 Medical Equipments, Multipara Monitor - Specificaitons - Type Of Monitor - Pre- Configured, Monitoring Parameters - Ecg ,hr,respiration Rate, Spo2, Pulse Rate Nibp,temperature ,ibp Length Of Time Of Full, Disclosure Of Patient Data In Hr - Greater Than Or Equal To 24, Length Of Time Of Trending In Hr - Greater Than Or Equal To 72, Number Of Leads Of Ecg - 5, Ecg Waveform Number Of Leads Display - 7, Respiration Rate Measurement Range 0- 150 Bpm Or More, Spo2 Measurement Range 70 - 100 Percentage, Systolic Blood Pressure Monitoring Range 40 - 250 Mmhg Or More, Diastolic Blood Pressure Monitoring Range 10 - 200 Mmhg Or More, Type Of Probe - Skin, Number Of Channels For Ibp - 2, Sensor Type - Na, Display Size In Inches - 12, Traces Of Display - Greater Than 10 And User Interface Of Display - Touchscreen And Rotary Knob. Refer Schedule A Of Tender Document., Ecg Machine - Specifications - Description Of Function - Ecg Machine Is A Primary Equipment To Record Ecg Signal In Various Configurations, 12 Channels With Interpretation Is Required For Recording And Analysing The Waveforms With Special Software. It Should Have The Optional Facility To Measure And Display Waveforms Of 6 More Ec Of Back And Right Chest Region. General Requirements - 1. The Ecg Machine Should Be Able To Acquire All 12 Leads Simultaneously For Both Adult And Paediatric Patients. 2. Should Have Facility To Interpret 12 Lead And Derive 6 More Ecg Of Back - V7, V8 And 9 And Right Chest Region - V3r, V4r, V5r. 3. Must Be Able To Display All 12 Lead Ecg And Other Data On Bright Colour Backlit Lcd With Minimum 7 Inch Display. 4.should Display All Ecg Waveforms Patient Information, Heart Rate, Qrs Mark, Error Message - 12 Lead Ecg Display With Print Preview - Qtc Interval - Hrv Analysis, Recording Speed Change Option. 5. Should Be Easy To Operate, Compact And Lightweight Not Exceeding 5 Kg Including Battery. 6. Should Have Alpha-numeric Keyboard For Patient Data Entry. Refer Schedule A Of Tender Document., Bio Safety Cabinet - Specifications- 1. Class I Is The Most Basic Bio-safety Cabinet That Provide Protection To The Environment And The Laboratory Personnel. 2. It Does Not However Provide Protection To The Product As The Un-sterilised Room Air Is Drawn Over The Work Surface. 3. Class I Bio-safety Cabinets Are Typically Used To Either Enclose Specific Equipment Like Centrifuge Or For Procedures Like Aerating Cultures That Might Potentially Generate Aerosols. 4. Bio-safety Cabinets Of This Class Are Either Ducted -connected To The Building Exhaust System- Or Unducted -re-circulating Filtered Exhaust Back Into The Laboratory. 5. In The Class I Bio-safety Cabinet, The Room Air Is Drawn In Through The Opening That Also Allows The Entry Of The Operator Arm During Work. 6. The Air Inside The Cabinet Then Takes The Aerosol Particles That May Have Been Generated And Moves It Away From The Operator Toward The Hepa Filter. 7. The Air Moving Out Of The Cabinet I Thus, Sterilised Via The Hepa Filters Before Its Discharge To The Environment. 8. In This Way, Cabinet Protect The Operator And The Environment From The Aerosol But Not The Sample. Refer Schedule A Of Tender Document., Syringe Pump - Specifications- The Syringe Infusion Pump Provides Uniform Flow Of Fluid By Precisely Driving The Plunger Of A Syringe Down Its Barrel. It Provides Accurate And Continuous Flow Rate For Precise Delivery Of I.v. Medication In Critical Medical Care. I. Operational Requirements - L. The Syringe Pump Should Be Programmable, User Friendly, Safe To Use And Should Have Battery Backup And Comprehensive Alarm System. 2. Demonstration Of The Equipment Is A Must. Ii. Technical Specifications - 1 . Flow Rate Programmable From 0.1 To 300 Ml Per Hr Or More In Steps Of 0.1 Ml Per Hr With User Selectable Flow Set Rate Option. Save Last Infusion Rate Even When The Ac Power Is Switched Off. 2.bolus Rate Should Be Programmable To 300 - 1200 Ml Per Hr Or More With Infused Volume Display. Reminder Audio After Every 0.5 Ml Delivered Bolus. Save Last Bolus Rate Even When The Ac Power Is Switched Off. 3.display Of Drug Name With A Provision Of Memorizing Names By The Operator, 4.keep Vein Open -kvo Must Be Available 1.0 Ml Per Hr Or Set Rate If Lower Than 1.0 Ml. User Should Have Choice To Disable Kvo Whenever Desired, Etc. Refer Schedule A Of Tender Document., High Frequency Radio Surgery Unit -rf, High Frequency Radio Surgery Unit -rf Cautery, Small Cautery Machine. Specifications - Operating Frequency - 2 Mega Hertz Frequency - 50 Hz, Electrodes - Insulated , Dimensions - 250 X 300 X 150 Mm, Weight - Lesser Than Or Equal To 7 Kg, Power Supply - 230 Volt, Output Power - 100 Watt. Refer Schedule A Of Tender Document., Mobile Endoscopy Unit - Mobile Endoscopy Unit-portable Endoscopy Unit. Specification - Integrated Camera-led Light Source - 1. 1-3 Inch Lcd Image Sensor, 2. 19 Mm Endocarpler, 3. Hi-portable Led Light Source, 4. Light Weigh Camera Head With Auto Iris Aperture And Osd, 5. Adjustable Led Brightness -off-mid-high Display -1. 12-13 Inch Display Size 2. Resolution- 1024 X768p- 60 Hz 3. Lcd Menu -brightness, Sharpness, Contrast, Gamma. 4. Composite Video 5. Osd Function With Key Pad 6.portable Carry Case With Safety Lock. Refer Schedule A Of Tender Document. are available inside the detailed notification files. Bidders planning to target this contract in Chennai should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Get Expert Tender Bidding Support

Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.

Call Our Expert: +91 7069661818
Your Information Is 100% Secure & Confidential