Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

30Results forTerminal building repair Tenders List

Latest Terminal building repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Terminal building repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Terminal building repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Terminal building repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Terminal building repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Terminal building repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Terminal building repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Terminal building repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Terminal building repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Terminal building repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Terminal building repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Terminal building repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Terminal building repair tenders.

Is EMD mandatory for all Terminal building repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Terminal building repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Terminal building repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Terminal building repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15792767
live Tender
Location : varanasi , uttar pradesh
Source : GEM Tenders
live Tender

tender for o and m with aicmc of hvac and vrv system at varanasi airport title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13 , title14 , title15 , title16 , title17 , title18 , title19 , title20 , title21 , title22 , title23 , title24 , title25 , title26 , title27 , title28 , title29 , title30 , title31 , title32 , title33 , title34 , title35 , title36 , title37 , title38 , title39 , title40 , title41 , title42 , title43 , title44 , title45 , title46 , title47 , title48 , title49 , title50, o and m with aicmc of hvac and vrv system at varanasi airport, operation and routine maintenance of water cooled chiller hvac system, 3x500tr i/c ahus and cooling tower, vrv system at various locations inside the terminal building and medical centre, various pumps and other installation of wtp and stp, ro, water coolers and split/tower/window ac units at various locations, water fountains inside the terminal building, ensuring serviceability/ satisfactory working condition of the systems i/c maintenance of records/logbook/ documents etc. on all days i/c saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following min. no. of man power- (a) supervisor (highly skilled) - 01 no. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 03 nos. (ie 01 no. round the clock on all days in every week for operation of chiller, reliever shall be provided on weekly off). (c) ac technician / mechanic (skilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of r.o., water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off). (d) asst. ac mechanic cum operator (semi skilled) - 09 nos. (i.e. 01 no. round the clock for operation of ahu, 01 no. round the clock for operation and maintenance of wtp, 01 no. round the clock for operation of stp on all days in every week, reliever shall be provided on weekly off). (e) asst. ac mechanic cum operator (semi skilled) - 01 no. (i.e. 01 no. in general shift for maintenance of stp, reliever shall be provided on weekly off). (f) helper (unskilled) - 03 nos. (i.e. 01 no. round the clock on all days in every week for hvac, reliever shall be provided on weekly off). (g) helper (unskilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of ro, water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off)., operation and routine maintenance of vrv system at ats cum technical block and precision air conditioning system at new mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) supervisor (highly skilled) - 01 nos. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 01 nos. (i.e. 01 no. in general shift on all days in every week for operation and routine maintenance of vrv system at ats cum technical block and pac system at new mssr building, reliever shall be provided on weekly off). (c) asst. ac mechanic cum operator (semi skilled) - 06 nos. (i.e. 01 no. round the clock for operation and routine maintenance of vrv system in ats block and 01 no. round the clock for operation and routine maintenance of pac system at new mssr building on all days in every week, reliever shall be provided on weekly off)., operation and routine maintenance of packaged air conditioning system at old mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) asst. ac mechanic cum operator (semi skilled) - 03 nos. (i.e. 01 no. round the clock for operation and routine maintenance of packaged air conditioning system at old mssr building on all days in every week, reliever shall be provided on weekly off)., annual all inclusive comprehensive maintenance contract of central ac plant (hvac) for 3x500tr (make- mcquay) centrifugal chiller type comprising of 3 no. cooling tower (make- advance) and 1no cooling tower (make- bell) with make-up tank, associated pumps as condenser water pump - 03 no(40hp), primary water pump - 03no (25hp), secondary water pump 12 hr - 03 no. (25hp), secondary water pump 24hr- 03 no. (15hp) with 06 no vfd with secondary pumps, hot water generator of 400kw (01 no) with in build panel for 8 zones , air handling unit (floor mounted) - 19 no. up to 100 tr and min 50tr capacity with 08 no vfds, ceiling suspended air handling unit - 17 no up to 3 to 5 tr with electrical starter panel in each hru 03 no of 4250 cmh, 4675 cmh, 2754 cmh with their electrical panels, ac risers - 82 no. with nozzles with respective ahus, ozone system of 06no of make- ruks canada ltd, electrical panel in plant room p1 , p2 and p3 for the operation of chillers, hot water generator and all associated pumps, water softening plant its electrical panel and pumps. above system complete including chiller pipe line, ac duct, grills diffusers, valves, gas charging, winding of motors, displays, instrumentations etc. complete as required related with hvac system. (the supply of consumable spares as mentioned in item-24 to 27 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive periodical maintenance of daikin make vrv system installed at new atc tower ,technical block and substation having total of 143 nos. vrv indoor units including ductable, high wall and cassette units of different capacities. total of outdoor units clubbed in 3 or 2 units together - 12 sets of total capacity of odu - 492 hp. maintenance work is inclusive of all spares required for repair, maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical equipment, safety controls and instrumentations, gas charging, fan , fan motors, thermal insulation, drain pumps, remote control console/units etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including saturday,sunday and holiday etc. as required., annual all inclusive comprehensive maintenance contract of 144hp vrv air-conditioning system installed in security hold area and passenger boarding bridge fixed finger (16hp - 09 set outdoor units model no-jrnu160lte5.apune, 4 tr- 16 set cassette type indoor units model number-jrnu48gtma4.apune, 6.3 tr - 04 set ductable type indoor units model number-jrnu76gb8a4.apune, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed in airlines/aai offices in departure area inside terminal building (20hp - 01 set outdoor units model no- ivrfb-20th, 1.7 tr- 10 set cassette type indoor units model number-vlc-20, makes-bluestar) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. upto 1.5 tr window/split ac, annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (2tr split/cassette/tower ac), annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (3.0 tr split/tower type ac), annual comprehensive maintenance of water coolers of all type, makes and capacities with providing necessary consumables, spares, compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers wherever connected etc. complete as required., annual comprehensive maintenance of water purifiers of aqua guard make including replacement of all defective components like uv lamp etc. and consumables and carrying out bimonthly servicing at installed position etc. complete as required.(the supply of consumable spares filters as mentioned in item no-40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro up to 50 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro above 50 up to 100 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39and40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), all inclusive comprehensive maintenance of 3 units each of 2x8tr capacity packaged air-conditioning plant installed at old mssr building (make - bluestar) including replacing defective components, carrying out preventive and breakdown maintenance like arresting of leakage, topping up of refrigerant gas, lubrication, rewinding/ replacing of all type of motors, repairing/ replacing of compressors, repairing / replacing of electrical components etc and other works required from time to time for proper maintenance of units including maintenance of records as per terms and condition all days including sundays and holidays., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at conference room and adjacent offices in terminal building including 2x 10hp outdoor units, 7x 2tr cassette type indoor units, make-daikin including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in passenger boarding bridge fixed link ( 1x 18 hp-02 set outdoor units model no-jrun180lls4, 4x 3tr-02set cassette type indoor units model number-rnu36gtna4, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 40hp vrv air-conditioning system installed in passenger boarding bridge fixed finger (1x 20hp-02 set outdoor units model no-jrun200lls4, 4x 3tr-02set cassette type indoor units model number-jrnu36gtna4 , makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in new fire station medical centre ( 3x 12 hp outdoor units, model no.-map1206ht8d-xa,cassette type indoor units 9x 2 tr, model no.- mmu-up0241hp-e and 3x1.5 tr, model no.-mmu-up0181hp-e make-toshiba) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of cold storage 40000 btu-02 set (make- bluestar) by providing quarterly visit and any number of break down as and when required including replacing/repairing compressor, condenser coil, temperature controller and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 3 x 15 tr (3 sets each of 01 no. indoor unit and 02 no. outdoor units) floor mounted, bottom discharge, top suction, air cooled dx type crac precision air-conditioning system units installed in new mssr building suitable to maintain equipment room temperature at 18 deg c plus minus 2 deg c (1x 15 tr - 03 set indoor units model no-pdx px054d, 2 no. x 03 set outdoor units model number-hcr-43 , makes-vertiv) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual comprehensive maintenance of drinking water fountain with chilling water fountain one at higher level and another at lower level to match disability compliance make oasis/haws/wae including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), cleaning of the solar module regularly two cycle in a month including minor repairing of tulu pump and monitoring of 600 kwp (500kwp+100kwp)grid connected roof top mounted solar photo voltaic power plant by deploying minimum one number unskilled man power in general shift excluding weekly off including maintaining records as per special conditions of the contract and as per direction of e-i-c. (consumables cleaning material like wiper duster, pvc flexible pipe etc. are to be provided by the agency. the solar module are under warrantee whereas inverter to be maintained by oem. the agency has to liaison with oem for repairing/replacement of defective parts)., supply of spares for hvac not include in cmc item no. 4 (pvc fills 600x300x150mm), supply of spares for hvac not include in cmc item no. 4 (resin 220 na(o) for softener plant), supply of spares for hvac not include in cmc item no. 4 (salt for softener plant), supply of spares for hvac not include in cmc item no. 4 (chlorine for dosing in stp), supply and installation of copper tubing of suitable size up to 3tr split air-conditioning for inlet and outlet of refrigerant gas complete with electrical cabling and insulation etc. complete as required during shifting of existing ac units., supply and installation of 20 mm dia pvc rigid drain pipe i/c all accessories like bends, couplers, tees etc. complete as required during shifting of existing ac units., supply and fixing of insulation of nitrile rubber in existing copper tubing for both inlet and outlet of existing installed air conditioner etc. complete as required during shifting of existing ac units as per direction of eic., dismantling of high wall split type air-conditioning unit, shifting, re-installation, testing and commissioning of capacity up to 3.00 tr air-conditioner units, fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required as per direction of eic., rewinding of 10/15 hp motor of submersible pump of (different stages ) different makes as per original size of insulated copper wire, sleeves complete with connection, interconnection etc as required., repairing of 10/15 hp submersible pump and motor (excluding rewinding of motor) of different stages and different makes i/c replacement of bearing bush, neck rings, bowl bush, running sleeve, key full, sand guard complete etc as required., repairing and rewinding of the existing water pump/ sewerage pump motor of capacity 0.75 hp to 3.0 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding, reinstallation the same, including testing and make the system in serviceable condition as required., repairing and rewinding of the existing blower motor/ filtered feed pump etc. of capacity 5 hp to 7.5 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding and reinstallation the same, including testing and make the system in serviceable condition as required., testing of stp incoming and treated water sample on quarterly basis from reputed govt. lab and submission of test reports as per technical specifications.(rate for each sample), dismantling, removal, lowering, reinstalling, testing and commissioning of submersible pumps of different makes and capacities including arranging of tripod stand, chain pulley block etc. as required., supply of 3.7 kw/ 5.0 hp submersible pump-motor set suitable for discharge 80mm delivery of minimum 250 lpm against static head 45mtr consisting of multistage pumps with suitable motor suitable for operation on 415 volt, 50 hz a/c supply. pumps and motors must be connected with alignment shafts etc. complete as required., supply of shield membrane which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-13,14 and 22 suitable for kent/ aqua guard/oasis/haws/wae up to 100 liter capacity etc. complete as required., supply of carbon / sediment filter which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-12,13,14 and 22 suitable for up to 100 liter capacity etc. complete as required., drinking water potability test quarterly basis as per technical specifications (rate for each sample)., supply of consumable urea for equalization tank of stp., supply of sand for sludge drying bed at stp., repairing/replacement of blower pipe tube at stp with suitable size pipe, elbow,socket and flange complete as required., supply of air blower filter at stp compatible to existing air blower., supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part -ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 300 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part- ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 250 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 200 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 150 mm dia, annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at pm safe house including 2x 10hp outdoor units with 6 x 2 tr, 2 x 1.5 tr and 1 x 1.1 tr high wall type indoor units, make-hitachi including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required.


Tender Value : 20741360
Due Date : Jul 03, 2026
T18 Ref No : 15875280
live Tender
Location : ajmer , rajasthan
Source : GEM Tenders
live Tender

tender for transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , transportation charges up to 50 km for alternator up to 55 kva , transportation charges more than 51 to 100 km for alternator up to 55 kva , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , rewinding of main stator winding of alternator more than 20 kva and upto 55 kva , rewinding of main rotor winding of alternator more than 20 kva and upto 55 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of power diode for rotating rectifier assembly , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mm direct in ground , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 2 x 10 sq. mm 19 mm , supply and making end termination for 4 x 16 sq. mm 28 mm , providing and fixing 6 swg dia g.i. wire , supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors ,, rc for repairing servicing shifting of dea sets at hub sites under ba udaipur, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter chain in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of techo drive unit in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), supplying & fixing of 12 volt battery charging alternator on the existing dg set i/c making connections testing etc. complete as reqd. ( make -autolek or similar superior make), repairing and servicing of the 12 volt battery charging alternator for dg set i/c greasing, oiling, making connections testing etc. complete as reqd., repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., dismentalling of existing up to 20 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., dismentalling of existing more than 20 kva & upto 55 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., extra for shifting of existing dea set up to 20 kva capacity from rooftop of the building to ground floor / loading vehicle with the help of chain pulley / crane by ensuring safety to the existing construction at site and reparing of any damage during shifting / dismentling by making good the same etc. complete as reqd., loading of existing up to 20 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., loading of existing more than 20 kva & upto 55 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., transportation of up to 20 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., transportation of more than 20 kva & upto 55 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., unloading of existing dea sets of up to 20 kva dea sets from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., unloading of existing dea sets of more than 20 kva & upto 55 kva dea from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., installation, testing and commissioning of existing dea sets of up to 20 kva dea sets on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., installation, testing and commissioning of existing dea sets of more than 20 kva & upto 55 kva dea on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., repairing of up to 20 kva dea sets crank shaft i/c grinding, lapping, bushing, allignement etc complete as reqd., transportation charges up to 50 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., transportation charges more than 51 to 100 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main stator winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of power diode for rotating rectifier assembly for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq. mm (19 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required., supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.


Tender Value : 0
Due Date : Jun 29, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to terminal building repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the terminal building repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the terminal building repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in terminal building repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our terminal building repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For terminal building repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for terminal building repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for terminal building repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For terminal building repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for terminal building repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of terminal building repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for terminal building repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to terminal building repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in terminal building repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based terminal building repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for terminal building repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for terminal building repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for terminal building repair is declared L1 and is generally awarded the contract