Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

16Latest Sound enclosure Tenders List

Latest Sound enclosure Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Sound enclosure tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Sound enclosure tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Sound enclosure Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Sound enclosure tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Sound enclosure Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Sound enclosure Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Sound enclosure Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Sound enclosure tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Sound enclosure Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Sound enclosure sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Sound enclosure tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Sound enclosure tenders.

Is EMD mandatory for all Sound enclosure tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Sound enclosure work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Sound enclosure tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Sound enclosure Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 16955128
Location : lucknow , uttar pradesh
Source : GEM Tenders
LIVE TENDER

Unlock Full Tender Access

Start Free Trial to download documents before deadline

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16344844
Location : kargil , ladakh
Source : GEM Tenders
tender for ofc 12 core armd , ip video phones , ip audio phones , digital display interactive panel 75 inch with stand , multimedia projector 4k uhd laser projector , video conferencing camera elite premium 12x , quadro with extn , wireless microphone cascade 4 with sound bar , ai laptop i7 cpu 32gb ram rtx 4060 8 gb 1 tb ssd , high-end ai workstation i9 13900k 128 gb ddr5 ram rtx 4090 24 gb 2tb ssd liquid cooling , broad band radio 8 km , ote 40 km , 8 port switch optical , 9u network rack , 8 port fxo fxs 4 eth 4e1 and 01x optical port , 8 port fxo fxs 4 eth 4e1 and 02 x optical port , heavy duty mfd , cleaver cutter for ofc , optical power meter , straight joint enclosure 12 cores , line interactive ups 1 kva with 30 min backup , utp cable cat 6 305 mtr roll , rj45 connector pkt of 100 nos , crimping tool , sc to lc 5 mtr patch cord , sc to sc 5 mtr patch cord , lc to lc 5 mtr patch cord , e2k to e2k 5 mtr patch cord , 5 meter optical fiber pigtail lc connector , 5 meter optical fiber pigtail sc connector , 5 meter optical fiber pigtail e2k connector , ofc connector lc fc and sc zero db pkt of 50 nos , ofc connector e2k zero db pkt of 50 nos, procurement of it infra for upgradation of networking equipment for seamless comn, ofc 12 core (a), ip video phones, ip audio phones, digital display interactive panel 75 inch with stand, multimedia projector (4k uhd laser projector), video conferencing camera elite premium 12x, quadro with extn, wireless microphone cascade 4 with sound bar, ai laptop (i7 cpu, 32gb ram, rtx 4060 8 gb, 1 tb ssd), high-end ai workstation (i9 13900k, 128 gb ddr5 ram, rtx 4090 24 gb, 2tb ssd, liquid cooling, broad band radio 8 km, ote (40 km), 8 port switch optical, 9u network rack, 8 port fxo/ fxs (4 eth+4e1 & 01x optical port), 8 port fxo/ fxs (4 eth+4e1 & 02x optical port), heavy duty mfd, cleaver cutter for ofc, optical power meter, straight joint enclosure 12 cores, line interactive ups 1 kva with 30 min backup, utp cable cat 6 (305 mtr roll), rj45 connector (pkt of 100 nos), crimping tool, sc to lc 5 mtr patch cord, sc to sc 5 mtr patch cord, lc to lc 5 mtr patch cord, e2k to e2k 5 mtr patch cord, 5 meter optical fiber pigtail lc connector, 5 meter optical fiber pigtail sc connector, 5 meter optical fiber pigtail e2k connector, ofc connector lc, fc & sc (zero db)(pkt of 50 nos), ofc connector e2k (zero db) (pkt of 50 nos)
T18 Ref No : 15875280
Location : ajmer , rajasthan
Source : GEM Tenders
tender for transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , transportation charges up to 50 km for alternator up to 55 kva , transportation charges more than 51 to 100 km for alternator up to 55 kva , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , rewinding of main stator winding of alternator more than 20 kva and upto 55 kva , rewinding of main rotor winding of alternator more than 20 kva and upto 55 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of power diode for rotating rectifier assembly , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mm direct in ground , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 2 x 10 sq. mm 19 mm , supply and making end termination for 4 x 16 sq. mm 28 mm , providing and fixing 6 swg dia g.i. wire , supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors ,, rc for repairing servicing shifting of dea sets at hub sites under ba udaipur, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter chain in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of techo drive unit in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), supplying & fixing of 12 volt battery charging alternator on the existing dg set i/c making connections testing etc. complete as reqd. ( make -autolek or similar superior make), repairing and servicing of the 12 volt battery charging alternator for dg set i/c greasing, oiling, making connections testing etc. complete as reqd., repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., dismentalling of existing up to 20 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., dismentalling of existing more than 20 kva & upto 55 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., extra for shifting of existing dea set up to 20 kva capacity from rooftop of the building to ground floor / loading vehicle with the help of chain pulley / crane by ensuring safety to the existing construction at site and reparing of any damage during shifting / dismentling by making good the same etc. complete as reqd., loading of existing up to 20 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., loading of existing more than 20 kva & upto 55 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., transportation of up to 20 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., transportation of more than 20 kva & upto 55 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., unloading of existing dea sets of up to 20 kva dea sets from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., unloading of existing dea sets of more than 20 kva & upto 55 kva dea from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., installation, testing and commissioning of existing dea sets of up to 20 kva dea sets on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., installation, testing and commissioning of existing dea sets of more than 20 kva & upto 55 kva dea on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., repairing of up to 20 kva dea sets crank shaft i/c grinding, lapping, bushing, allignement etc complete as reqd., transportation charges up to 50 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., transportation charges more than 51 to 100 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main stator winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of power diode for rotating rectifier assembly for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq. mm (19 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required., supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.
T18 Ref No : 16121822
Location : bardhaman , west bengal
Source : GEM Tenders
tender for supply laying testing and connecting xlpe sheathed pvc insulated screened pvc size 3.5 core 240 sqmm complete all as specified and as directed. , supply installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy sound level not more than 75db , m and l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth pit not less than 2.25mtr , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in soft loose soil complete all as specified and as directed. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified and as directed. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil complete all as specified and as directed. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches of 230mm , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable complete all as specified and as directed. , s and f galvanised iron pipe 80mm bore dia light grade for protection of ug cable laid in floors road crossing , s and f hdpe dwc double walled corrugated of diameter 90 mm including disconnection and connection of cable , material and labour for manufacturing installation testing and commissioning of factory made and tested cpri approved amf , m and l for surface excavation n.exc not exceeding 30 cm deep and averaging 15cm deep , m and l for hardcore using broken stone or boulders of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick , m and l for cement concrete in foundations filling and mass concrete type d2 1 4 8 , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work , m and l for excavating in post holes or similar holes each n exc 0.5 cu. m getting out returning filling in and ramming earth , s and f for steel work in tubular trusses cloumn purlin including special shaped washer nut bolt etc. , s and f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick , m and l for preparation of steel surfaces of any description over 10 cm , m and l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 , providing and laying at or near ground level factory made kerb stone of m25 grade , m and l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm , s and f 4pole 630 amp changeover switch with enclosure suitable for 415 v ac 3phase 4 wire , wrecking crow bar or claw bar as per is 706 (q3), supply, laying, testing and connecting xlpe sheathed,pvc insulated screened pvc bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 240 sqmm complete all as specified and as directed., supply, installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy (sound level not more than 75db at a distance of 1 mtr) 14 guage as per guidelines issued by central pollution control board (cpcb ivplus, 4plus), 415 volts, 3 phase, 50 hz supply complete, control panel suitable for giving an output of 250 kva and alternator of suitable capacity and rpm coupled with each other with flexible coupling mounted on anti vibration pads on foundation as recommended by manufacturer. the dg set shall comprise of self starter with batteries, turbocharger, water cooler and comprising all standard fittings, fixtures & all piping etc. as below (a) alternator directly coupled with engine and suitable to produce 415 volts, 3 phase, 4 wire system, 50 hz, 0.8 pf 1500 rpm of capacity 250 kva all as per is 13364 and upto date amendments with h class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball / roller bearing with damper winding in each pole, complete all as specified and directed. (b) engine water cooled diesel engine (cpcb norms iv compliance) developing 105 bhp having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per oem) as per is 10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 rpm industrial type as per bs 649 or is 1601 with ai electronic governor suitable to regulate speed of dg set from no load to full load complete with fuel tank of capacity as per manufacturer s recommendation, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer muffiers etc. for continuous operation and standard accessories, sump pre heaters, cold start kit etc., m&l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground, earth pit not less than 2.25mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by provision of 40mm bore gi pipe medium grade and including provision of concrete pit in pcc 1 2 4 type b 1 (using 20mm grade crushed stone aggregate) with 40mm thcik rcc (type b 1) cover reinforced with 8mm dia tmt bar both ways with 12mm dia round bar handle and frame of angle iron 25x25x3mm with lugs 02 nos and 20mm bore gi light grade watering pipe with funnel and wiremesh and filling common salt and charcol and test point with fixing arrangements and including necessary excavation in any type of soil, returning filling in and removing excavated soil to a distance of 50mtr from the site, complete all as shown on electrical plate no 3 of mes ssr part i and directed., excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil, complete all as specified and as directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed., removing excavated materials (soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil, complete all as specified and as directed., m&l sand cushioning (dry) in trenches for protection of ug cables (below, above and around the ug cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (note for the purpose of payment, punned thickness of sand cushioning only shall be measured and paid)., m&l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable, complete all as specified and as directed., s&f galvanised iron pipe 80mm bore (dia) light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., s & f hdpe dwc (double walled corrugated) of diameter 90 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., material and labour for manufacturing, installation testing and commissioning of factory made and tested, cpri approved amf panel for 250 kva dg set, indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 volts, 3 phase 4 wire 50hz ac supply system, conforming to is 5039, ip54 class protection and made of 3mm crca mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated al. bus bar 1000 amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for mccb with suitable capacity of al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments including necessary pcc in 1 2 4 type b1 using 20mm graded stone aggregate for platform of suitable size , prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following acessories incomer1 & 2 (main & dg) (a) busbars 1000a tpn 415volts 3phase 4 wire color coaded aluminium busbars 1 lot (b) mccb 630a fp edo 50ka microprocessor based ( o/c, s/c & e/f) release with motor, closing & shunt, aux. contact 4noplus4nc 2 nos. (c) amf relay (econ) 1 nos. (i) digital ammeter 1 nos. (ii) digital voltmeter 1 nos. (iii) ct 1000/5a cl1 10va 1 nos (iv) phase indication light red 230v ac 1 nos. (v) phase indication light yellow 230v ac 1 nos. (vi) phase indication light blue 230v ac 1 nos. (vii) indication lamp 22mm dia color red 240v ac (on) 2 nos. (viii) indication lamp 22mm dia color green 240v ac (off) 2 nos. (ix) indication lamp 22mm dia color amber 240v ac (trip) 2 nos. etc., m&l for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed., m&l for hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m&l for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed., s & f for steel work in tubular trusses, cloumn, purlin including special shaped washer, nut, bolt etc. complete using erw or induction butt welded tubes conforming to i.s.1161 1979 grade st.240 complete all as specified., s&f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, m & l for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified, m&l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 of 60 mm thickness, m35 grade with grey cement and pigment all as specified and directed., providing and laying at or near ground level factory made kerb stone of m25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1 3 (1 cement 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed., m&l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by engrincharge., s&f 4pole, 630 amp changeover switch with enclosure, suitable for 415 v ac, 3phase, 4wire, 50 hz system, for changeover between main supply and dg set. the switch shall be heavyduty, onload type conforming to is/iec 609473, with silver alloy contacts and adequate breaking capacity. the unit shall be mounted on a sturdy angle iron frame fixed over pcc block with necessary nuts, bolts and support structure. terminals shall be suitable for cable/busbar connection and provision for safe manual operation (or motorised operation, if required) shall be included complete with all accessories, mounting hardware all as specified and directed.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15982830
Location : rishikesh , uttarakhand
Source : GEM Tenders
tender for procurement of day to day electrical maintenance material electric male female connector , 6 amp 3 pin top , 16 amp 3 pin top , pvc insulation tape roll 3 meter , ht tape 3 meter , 6 sq mm ring type copper lugs , 6 sq mm pin type copper lugs , 10 sq mm pin type copper lugs , 10 sq mm ring type copper lugs , 16 sq mm ring type copper lugs , 16 sq mm ring type aluminium lugs , 25 sq mm ring type aluminium lugs , 35 sq mm ring type aluminium lugs , 50 sq mm ring type aluminium lugs , 150 sq mm ring type aluminium lugs , 300 sq mm ring type aluminium lugs , 16 sq mm tubular lugs copper , 16 sq mm tubular lugs aluminium , 63 amp 4 pole mccb 25k , 100 amp 4 pole mccb 36k , 125 amp 4 pole mccb 36k , 40 amp. mcb 4 pole , 63 amp. mcb 4 pole , 32 amp. mcb 2 pole , 40 amp. mcb 2 pole , 10 amp mcb 1 pole , 16 amp mcb 1 pole , 25 amp mcb 1 pole , 1.5 sq.mm copper wire frls r,y,b, black colour , 2.5 sq.mm copper wire frls r,y,b, black colour , 4 sq.mm copper wire frls r,y,b, black colour , 6 sq.mm copper wire frls r,y,b, black colour , 10 sq.mm copper wire frls r,y,b, black colour , 1.5 sq.mm 3 core copper flexible cable , 2.5 sq.mm 3 core copper flexible cable , 4 sq.mm 3 core copper flexible cable , 6 sq.mm 3 core copper flexible cable , 6 sq.mm 4 core copper flexible cable , 10 sq.mm 3 core aluminium flexible cable , 10 sq.mm 4 core aluminium flexible cable , 16 sqmm 4 core aluminium armoured power cable , 25 sqmm 4 core aluminium armoured power cable , 35 sqmm 4 core aluminium armoured power cable , 16 amp combined box , 6 amp combined box , 25 amp ac combined box with top , power extension board with 4 meter cord , multiplug 5 amp universal type , 32 amp mcb 1 pole , pvc batten 20 mm 6 feet each , pvc batten 25 mm 6 feet each , pvc batten 50 mm 6 feet each , pvc flexible conduit pipe 20 mm. 3 meter , pvc flexible conduit pipe 25 mm.3 meter , pvc flexible conduit pipe 32 mm. 3 meter , pvc cable clip 10 mm , 4 way tpn db. d.door , 8 way spn db d. door , 6 way spn db d. door , elen key set , hole saw cutter 10 to 300 sqmm , jonior hexa frame , jonior hexa blade , hexa frame , hexa blade , grinder machine , grinder blade , pin type anchor fastner 6x75 mm , pin type anchor fastner 8x100 mm , pin type anchor fastner 10x100 mm , m10 hexagon head red anchor fastener,10x100 mm , gypsum screw 1.5 inch , gypsum screw 2 inch , gypsum screw 4 inch , pvc gitti 35x8 50 nos per pkt , pvc gitti 50x8 50 nos per pkt , self screw 1.5 inch , batten nails 100 nos per pkt , pvc saddle 25mm 100 nos per pkt , pvc saddle 20mm 100 nos per pkt , pvc saddle 32mm 100 nos per pkt , mild steel span bolt and nut 12mmx 80mm , mild steel span bolt and nut 10 mmx 50 mm , mild steel span bolt and nut 18 mmx 80 mm , mild steel l-key bolt and nut 16 mmx 50 mm , flexible metalic conduit size 25-32 mm , nylon cable tie, length 200x3.6mm 100 nos perpkt , nylon cable tie, length 250 x 4.2 mm 100 nos per pkt , nylon cable tie, length 300mm x 4.6mm 100 nos per pkt , nylon cable tie, length 100 x 2.5 mm 100 nos per pkt , nylon cable tie, length 150 x 2.5 100 nos per pkt , led bulb 9w color temp 6500k , hammer bit 6mm , hammer bit 8mm , hammer bit 10mm , hammer 12mm , drill bit set 1.5-6mm , pvc bend pipe25mm 20 nos per packet , small size goti set 0.25 inch drive socket set , hydraulic crimping tool 16-300 sqmm , electric bell ding dong , uv light 18 watt 2 feet , exhaust fan 9 inch metallic body , exhaust fan 12 inch metallic body , geyser thermostat , contactor 4 pole 40a, 220v , analog timer, heavy duty plastic body, copper/brass contacts, 240v ac make- gm modular, anchor, mx, greatwhite, brass pins, heavy duty plastic body, isi marked make-gm, anchor, greatwhite, l&t, pvc electrical grade insulation tape, flame retardant make-steelgrip, 3m, agi, syska, high tension insulation tape, high dielectric strength make-steelgrip, 3m, agi, syska, tinned copper, crimping type, is 8309 make-dowells, jainson, comet, elora, ec grade aluminium, crimping type make-dowells, jainson, comet, elora, tinned copper, heavy duty tubular type make-dowells, jainson, comet, elora, ec grade aluminium tubular type make-dowells, jainson, comet, elora, 415v ac, 4 pole, 36ka breaking capacity, is/iec 60947-1 make-schneider electric, l&t, siemens, abb, 415v ac, 4 pole, 36ka breaking capacity, is/iec 60947-2 make-schneider electric, l&t, siemens, abb, 240/415v ac, 6/10ka breaking capacity, c curve make-schneider electric, havells, l&t, abb, 240v ac, 6ka breaking capacity make-schneider electric, havells, l&t, abb, annealed electrolytic copper, frls pvc insulated, 1100v grade, is 694, 70 c rating, color coded make-polycab, finolex, kei, havells, multi-strand copper conductor, pvc insulated & sheathed, 1100v grade, is 694/8130 make-polycab, finolex, kei, havells, stranded aluminium conductor, pvc insulated, 1100v grade, is 694 make-polycab, finolex, kei, havells, stranded aluminium conductor, xlpe insulated, pvc sheathed, steel armoured, 1.1kv grade, is 7098-1 make-polycab, finolex, kei, havells, fire retardant polycarbonate body, brass terminals, 240v ac rated make-gm, anchor, greatwhite, honeywell, heavy duty polycarbonate body, suitable for ac load, 240v ac make-gm, anchor, greatwhite, honeywell, pvc insulated flexible cord, multi socket outlet, 240v ac make-gm, anchor, greatwhite, honeywell, universal socket type, flame retardant body, brass contacts make-gm, anchor, greatwhite, honeywell, rigid pvc casing, flame retardant make- akg, precision, supreme, vectus, flexible pvc conduit, is 9537 make- akg, precision, supreme, vectus, heavy duty pvc clip make- akg, precision, supreme, vectus, crca sheet steel enclosure, powder coated, ip42 make-schneider electric, havells, l&t, abb, chrome vanadium steel, hardened make-taparia, stanley, bosch, jcb, bi-metal hole saw set make-bosch, stanley, addison, maxpro, steel frame for small hacksaw blade make-taparia, stanley, bosch, maxpro, hardened steel blade make-taparia, stanley, bosch, maxpro, heavy duty hacksaw frame make-taparia, stanley, bosch, maxpro, 750w motor, 10000+ rpm make- bosch, makita, stanley, dewalt, abrasive cutting disc make-bosch, norton, maxtech, 3m, high tensile steel, zinc plated make-fischer, canon, hilti, maxwell, high tensile steel, heavy duty concrete fixing make-fischer, canon, hilti, maxwell, hardened steel, zinc coated make-atul, gkw, sundram, fischer, plastic wall plug, 50 nos per pack make-akg, supreme, precision, vectus, self tapping, zinc coated make- atul, gkw, sundram, fischer, mild steel, corrosion resistant make- atul, gkw, sundram, fischer, heavy duty pvc saddle make-supreme, akg, precision, vectus, mild steel, zinc coated make-tvs, unbrako, atul, sundram, ( strip steel, bright, cold rolled and annealed andequivalent to is 513 o grade. sheet steelthickness shall be minimum 0.25mm),cold rolled annealed steel strip, min 0.25mm thick make-akg, precision, jainco, supreme, nylon 66, self locking, uv resistant make-panduit, dowells, rutronik, elora, 220v-240v ac, cool white, b22/e27 base, 15000+ hrs life make-philips, syska, havells, wipro, carbide tipped masonry bit make- bosch, taparia, makita, dewalt, high speed steel bits make- bosch, taparia, makita, dewalt, heavy duty pvc bend, 20 nos per packet make-akg, supreme, precision, vectus, chrome vanadium steel make- bosch, taparia, makita, dewalt, crimping range 16-300 sqmm type hand-operated hydraulic hexagonal die set included make-jainson, dowells, elmex, elora, voltage-220-240v ac sound type ding dong abs body wall mount type make-anchor, honeywell, gm, syska, wattage- 18w length- 2 feet tube type- uv fluorescent suitable for insect killer sterilizer unit make-philips, crompton, bajaj, havells, rated voltage- 220-240v ac frequency- 50 hz power consumption- 30-45 watts motor copper winding speed- approx 1200 rpm air delivery-minimum 350-450 cmh bearing double ball bearing body mounting wall window mount noise level- low noise operation standard is 2312 duty continuous make-crompton, bajaj, usha, havells, rated voltage-220-240v ac frequency-50 hz power consumption- 55-75 watts motor- copper winding motor speed-1300-1400 rpm air delivery- minimum 800-1000 cmh body- powder coated metal or heavy duty plastic shutter automatic gravity shutter if required bearing- ball bearing type standard- is 2312 make-crompton, bajaj, usha, havells, application- suitable for storage type electric water heater (geyser) rated voltage-220-240v ac frequency-50 hz current rating-15a / 16a temperature range-adjustable 30 c to 75c (approx)type- capillary type / rod type thermostat sensing element-copper capillary with temperature sensor bulb contact type- silver alloy contacts for long life cut-off mounting-screw fixing / flange mounting insulation- high temperature resistant insulation safety-compatible with thermal cut-out protection standard- is 302 (part 1) / iec equivalent suitable for- 10l, 15l, 25l storage geysers make-crompton, racold, havells, kelvinator, type-4 pole (4p) contactor poles- 4 normally open (as required) rated operational voltage (ue)- up to 415v ac rated insulation voltage (ui)- 690v frequency- 50/60 hz rated current (ie)- 25a / 40a / 63a / 100a (as per requirement) utilization category- ac-1 / ac-3 / ac-4 (as applicable) short circuit withstand capacity-as per manufacturer rating make-schneider electric, l&t, siemens, abb, rated voltage- 220-240v ac frequency-50/60 hz rated current- 16a (resistive load) switching capacity- 250v ac power consumption- low power coil consumption make-schneider electric, theben, l&t, hager, output voltage-12v dc output current options- 5a output power- based on current rating ripple & noise- 120mvp-p 5a,12v, make-mean well, delta, phoenix contact, tdk lambda, hi-light

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Sound Enclosure. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Sound Enclosure sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Sound Enclosure Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Sound Enclosure, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Sound Enclosure Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Sound Enclosure Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Sound Enclosure.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Sound Enclosure depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Sound Enclosure Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Sound Enclosure bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Sound Enclosure. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Sound Enclosure, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Sound Enclosure, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Sound Enclosure?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Sound Enclosure tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Sound Enclosure?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Sound Enclosure, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Sound Enclosure is declared L1 and is generally awarded the contract