Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

5Results forLatest Soil testing equipment repair Tenders List

Latest Soil testing equipment repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Soil testing equipment repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Soil testing equipment repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Soil testing equipment repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Soil testing equipment repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Soil testing equipment repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Soil testing equipment repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Soil testing equipment repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Soil testing equipment repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Soil testing equipment repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Soil testing equipment repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Soil testing equipment repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Soil testing equipment repair tenders.

Is EMD mandatory for all Soil testing equipment repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Soil testing equipment repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Soil testing equipment repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Soil testing equipment repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15286275
Source : GEM Tenders

tender for xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply, installing, testing and commissioning of pdb panel 800a, 415v. the panel shall be indoor wall mounted. it shall be completely made of crca sheet steel. , supply, installing, testing and commissioning of pf correction panel with rms 430kvar, 415v. panel indoor floor mounted, free standing with ip-31 degree of ip made of crca sheet steel. , material and labour for xlpe insulated, lt armoured electric sense cable with aluminiur star ded conductor 1100 volts grade, cross- sectional area 4 sqmm, 6 core , m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed , supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying cif cables, pipe lines, protection pipes , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed , material and labour for earthing complete with copper plate electrode 600mmx 600mmx. 3.1.5 mm thick buriel directely in ground vertically , supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , civil work rcc panel base slab size - 2000mm l x 1300mm w x 150mm thickness , warranty service amc by cmc including breakdown service for 1 year to ensure the safe, reliable, and efficient operation of the electrical panel, provision of solar factor correction for 1 mw solar plant, the enclosure shall have sturdy support structure with angle suppors as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the panel shall be suitably sized to accommodate all the compor ents, providing necessary air clearance between live and non-live parts, providing necessary working clearance. incomer shall pe al busbars. power outgoing shall be one 800a, 415v, 50ka, tp, mccb, tm. bus bar shall be of aluminium with 0.8a by sq. mm current dens ty. suitable indication lamps for - phase supply indication and circuit elreaker - trip indication should be provided. mccbs shall be with door inter ocking protection systems. bus bars shall have coloured pvc sleeves. 800a outgoing shall be used to feed the 430kvar, 415v step-less pf correction system complete all as specified anc directed, the enclosure shall have sturdy support structure with angle supports as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the step-leiss pf correctior panel system shall be without any pf correction passive capacitor banks, but single or mutiple module combination of static var generator, which can measure the actual requirement of reactive currents and produce and inject the same reactive currents inductive or capacit ve as per the system needs to compensate the reactive power demand individual phase -wise. there shall be one hill cum svg controller digital signal processor to sense the load current and operate the svg modules connected with the svg panel. reaction time of that dsp shall be 10 msec, so that cycle to cycle compensation to be established. the hmi display unit shall have 15channel oscilloscope to display live-status of the 3phase voltage, load current, grid current and svg currents, along with all major electrical pq parameters. svg modules should have efficiency of less than 98 percent and internal losses 2 percent of its full capacity. the svg modules shall have internal fan for heat dissipation by force air cooling method. maximum 50 no.s modules can be connected in parallel per ct set. the svg modules should be operated within the voltage range 350v to 480v. ambient temperature should be 0-45 temp c. noise level shall be 5db. built-in semiconductor-fuse protection for the svg modules is a must. load ct shall have 5a secoridary and in general it will be connected in close loop. full rating of individual static var generator moclule shall be 125kvar, 480v, 1504, which will output 107.8kvar at 415v ac. so, considering the 4nos of modules it will output 431.2kvar at 415v., laid in trenches by pipes by ducts by wall by boarings with necessary cable lugs and glands, nuts, bolts and washers etc and test ng complete all as specified and directed, m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed, supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover complete all as specified in ssr part-l and as directed, foundations etc and getting out in soft loose soil complete all as specified and directed., returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed, remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres belcw ground level, connected to and including coper strip of size 20 x 3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-l and gl watering pipe of 20 mm dia medium grade, gi funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1-3-6 lype c1, rcc cover 1-2-4 type b1, ncluding excavation by earth work in any strata and returning filling, removal of surplus soil anc testing for required value complete all as specified and directed., supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed, concrete grade -m25 mix ratio 1-2-1 - cement- sand- aggregate bot om reinforcement 12mm dia. tmt bars placed at - 150mm centre-to-centre spacing in both directions both ways top reinforcement- 10mm dia. tmt bars placed at 200mm centre-to-centre spacing in both directions both ways edge stirrups 8mm dia tmt bars placed at 200mm centre-to-centre spacing in both directions both way formwork proper shuttering to be provided to achieve specified dimensions and line and level. total load 700kg or 6.9kn. cable trench 300mmx300mm and ms chequered plate cover for trench. base plate- ms charinel by flat ismc 100 or 10mm thick plate. curing - minimum 7 cays of water curing or as per is 4-56 recommendat ons plastering over base slab plaster mix cement mortar 1-6 - cement- sand finish- surface to be finished with neat cement punning after plastering as required preparation surface to be cleaned and wetted before application. proper bonding and uniformity to be ensured cutting and mending in brick wall scope- cutting holes in brick walls for service entries pipes, cables, etc. maximum diameter up to 150mm mending work- all damages to be made good using cement mortar cernent consumption approx. 4 kg per meter of hole length as per estimate restoration to match existing finish plaster or paint, its associated systems through periodic inspection, testing, servicing, and emergency support over a period of one year after one year dlp duration one 1 years from the date of completion of dlp. services included scheduled quarterly site visits, visual inspection for overheating, corrosion, physical damage, cleaning of preventive maintenance panels dust, debris, moisture control, tightening of connections and torque testing of terminals, megger testing of insulation resistance, functional test of breakers and rcds corrective maintenance fault finding and diagnosis for reported issues, replacement of defective components, repair of wiring or damaged insulation, troubleshooting tripping or overloads emergency support on-site visit within 48 hours of call define sla clearly documentation and reporting maintenance logs and service reports after each visit annual performance summary report


Agency / Dept : indian army
Tender Value : 0
Due Date : May 18, 2026
T18 Ref No : 15286276
Location : kolkata , west bengal
Source : GEM Tenders

tender for xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply of power distribution panel 400a, 415v. the panel indoor type floor mounted and free standing designed for ip-4x ingress protection, made of crca sheet steel. , supply only pf correction panel with svg 430kvar. 415v panel indoor floor mounted, free standing with ip-31 degree of ingress protection made of crca sheet steel , material and labour for pvc insulated, lt unarmoured sheathed frlsh electric sense cable with copper multistanded conductor 1100 volts grade, cross-sectional area 4 sqmm, 6 core , material and labour for chemical earthing complete with copper bonded 250 micron electrode 1500mm long and 25 mm dia , materal and labour for earthing complete with gl earth plate 600mmx600mmx6mm thick electrode buried directly in ground vertically to a depth not less than 2.25 meter , material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 20x3mm galvanised iron or steel wire , material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 32x6mm galvanised iron strip , supply and fixing 40 mm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , material and labour for rcc 1-2-4 type b-1, using 20 mm graded stone aggregate as in foundation, including rafts, footing, foundation beams, , material and labour for steel reinforcement for concrete with ms tmt bar 10mm dia and over cut to length, bend to shape required including cranking, bending, , warranty service amc by cmc including breakdown service for 5 years to ensure the safe, reliable, and efficient operation of the electrical panel, provision of solar power plant factor of capacity 0 point 6 mwp, the enclosure shall have sturdy support structure with angle supports as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation, air aspiration louvers for proper air circulation shall be provided as necessary. the panel shall be suitably sized to accommodate all the components, providing necessary air clearance between live and non-live parts, providing necessary working clearance incomer mccb four pole 400a, 415v, 50ka with thermal magnetic protection having door interlocking to prevent operation while the panel door is open - 01 power outgong terminal shall be sitable for connection to down stream equipment, svg panel, distribution boards. bus bar shall be of alumintum with 0.8ab by sq.mm current density covered with pvc insulated sleeves and mounted on dmc insulators digital multifunction meter panel mounted suitable for measure voltage, current, active power (kw), reactive power kvar, apparent power kva, power factor pf, energy kwh, frequency hz with cts of appropriate class and accuracy and of suitable rating for 400a mccb outgoing mccb four pole 400a, 415v, 50ka with thermal magnetic protection having door interlocking to prevent operation while the panel door is open-01, the enclosure shall have sturdy support structure with angle supports as necessary enclosure shall be finished willt powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035 suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the step-less pf correction panel system shall be without any pf correction passive capacitor banks, but single or multiple module combination of static var generator, which measure the actual requirement of reactive currents and produce and inject the same reactive currents inductive or capacitive as per the system needs to compensate the reactive power demand individual phase wise there shall be one hmi cum svg controller digital signal processor to sense the load current and orerate the svg modules connected with the svg panel reaction time of that dsp shall be 10 msec, so that cicle to cycle compensation to be established the hmi display unit shall have 15channel oscilloscope to display live-status of the 3phase voltage, load current, grid current and svg currents, along with all major electrical pq parameters svg modules should have efficiency of 98 percentage and internal losses 2 percent of its full capacity the svg modules shall have intereal fan for heat dissipation by force air cooling method maximum 50 nos modules can be connected in parallel per ct set. the svg modules should be operated within the voltage range 350v to 480v ambient temperature should be 0-45 temp c. noise level shall be 65db. full rating of individual static var generator module shall be 125kvar 480v, 150a, which will output 107 8kvar at 415v ac so, considering the 4nos of modules it will output 430kvar at 415v using 4 nos. 125 var modules rated at 480v with compensation range 100kvar to +125 kvar step less hmi shall have provision of cloud connectivity to check live status of the system.complete all as specified and directed., laid in trenches by pipes by ducts by wall by boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed, with terminal size 40 x 6mm burmed in ground by digging a bore of 50mm dia surround by soil friendly backfill compound non soluble in water including connection with galvanized earth strip 32x6 making pcc pit of size 0.3mx0.3mx0 3m inner size in mix 1-3-6 type ci with rcc 1-2-4 type b1 40 mm thick cover forced with 6mm dia ms bars 3 nos both ways with lifting hook made out of 8 mm dia bar and testing on contction to achieve value not more than 10 ohm complete all as specified and directed, below normal ground level with top edge of earth plate not less than 1.5 meter below ground level connected to 32x6mm galvanised iron strip as earthing lead main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 with connected to earth test point and to main switch board with and including adequate quantity of charcol dust and common salt around earth plate and g1 pipe 20mm dia light grade for watering pipe with funnel & wire messn including necessary earthwork and 40 mrn dia medium grade gi pipe for protection of strip and pcc 1-3-6 type c-1 for earth pit thick pre-cast rcc cover in 1- 2-4 type b1 with 3 nos 8mm dia tmt bars both ways complete all as specified and directed by engineer-in-charge., material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 20x3mm galvanised iron or steel wire, material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 32x6mm galvanised iron strip, supply and fixing 40 mm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed, plinth beams columns etc under reamed piles and mass concrete, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or sequring with clips complete all as specified and directed, its associated systems through periodic inspection, testing, servicing, and emergency support over a period of one year after one year dlp duration one 1 years from the date of completion of dlp. services included scheduled quarterly site visits, visual inspection for overheating, corrosion, physical damage, cleaning of preventive maintenance panels dust, debris, moisture control, tightening of connections and torque testing of terminals, megger testing of insulation resistance, functional test of breakers and rcds corrective maintenance fault finding and diagnosis for reported issues, replacement of defective components, repair of wiring or damaged insulation, troubleshooting tripping or overloads emergency support on-site visit within 48 hours of call define sla clearly documentation and reporting maintenance logs and service reports after each visit annual performance summary report


Agency / Dept : indian army
Tender Value : 0
Due Date : May 18, 2026
T18 Ref No : 15300771
Location : barmer , rajasthan
Source : GEM Tenders

tender for s and f of ring main system for wss, supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc, supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc, supply and fix valve reflux with by pass arrangement 100mm 4 inches dia, supply and fix foot valve confirming to is 4038 100mm 4 inches dia, supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia, supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia, supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc, supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core, supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core, supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc, supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc, supply installation test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc, supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in cast iron water supply mains, excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc, returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge, removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc, boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure, cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special, cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special, di or ci special such as tee bend collar tail piece and other fitting as required, earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode, demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness, m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness, m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc, m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc


Agency / Dept : indian army
Tender Value : 0
Due Date : May 28, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15327818
Source : GEM Tenders

tender for spl repair for replacement of 2 transformer against ber transformers cable termination kit suitable for cables up to and including 33 kv (v2) (q3) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply installation testing commissioning of step down transformer voltage rating ht11 bye 0. 433 kv out door type of capacity 250 kva level 2 3 phase 4 wire 50 hz , supply, installation , testing and commissioning of step down transformer voltage rating ht11 by 0.433 kv, out door type of capacity 315 kva level 2, 3 phase, 4 wire,50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core.complete all as specified and directed in boq spec file , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , material and labour for earthing complete with copper plate electrode 600mmx 600mmx 3.15 mm thick buried directely in ground vertically.complete all as specified and directed in boq spec file , m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file , boaring holes horizontally under road without damaging the surface of road minimum1.0 mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable. , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file , disconnected all electrical connections and earth strip at existing transformerall connected accessories by cables and shifting of 11 kv by 0.433 volts 200 kva to 315 kva capacity transformer., spl repair for replacement of 2 transformer against ber transformers, oil cooled core type floor mounted delta bye star connected maximum losses as defined in vector group dyn 11 double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 250 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories guages first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639 to 1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings bye accessories fitted complete all as specified and directed, oil cooled, core type, floor mounted, delta by star connected maximum losses as defined in vector group dyn 11, double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 315 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories, guages, first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fitting by accessories fitted complete all as specified and directed., insulated screened pvc bedded galvanized steel strip or wire armoured electric power cables heavy duty with standard aluminium conductor 11000 volts earth garde of cross sectional area 3 core 120 sqmm completed all specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 matres below ground level connected to and including galvanised iron strip of size 32 x 6 mm from earth earth electrode to test point bye equipment or up to 7.5 metres whichever is less by means of gi bolts nuts, check nuts and washers all as per electrical plate no 3 of ssr pt 1 and gl watering pipe of 20 mm dia medium grade gi funnel with wire mesh including charcoal salt packed all around the earth electrode plate in layers pcc earth pit chamber 1 ratio 3 ratio 6 type c1 rcc cover 1 ratio 2 ratio 4 type b1 including all excavation bye earth work in any strata and returning filling removal of surplus soil and testing for required value complete all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres below ground level, connected to and including coper strip of size 20x3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-i and gl watering pipe of 20 mm dia medium grade, gl funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1 ratio 3 ratio 6 type c1,rcc cover 1 ratio 2 ratio 4 type b1, including excavation by earth work in any strata and returning filling, removal of surplus soil and testing for required value, m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file, supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in ssr part i and as directed, excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed in boq spec file, returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file, removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file, m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file, boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable all as specified and as directed, supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file, transportation safely by hydra by lifting vehicle including providing suitable carrying vehicle to proposed power houses or mes yard as per suitable directions of engr-in-charge and making all electrical connections properly with earth strip etc and to be re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such nuts, bolts, washers, lugs, sleevs etc and megger testing and complete all as specified and directed in boq spec file


Agency / Dept : indian army
Tender Value : 0
Due Date : May 21, 2026
T18 Ref No : 15379083
Location : mumbai , maharashtra
Source : GEM Tenders

corrigendum tender for main signal , shunt signal , panel servicing work , signaling cable , cable trench excavation , cable laying , main signal termination , shunt signal termination , hdpe pipe supply , pipe laying work , signal dismantling work , interlocking system overhaul, replacement of signal and interlocking system at mbpa railway yard wadala, main signal units including complete structure fittings and associated works as per standard specifications refer tender document for detailed description, shunt signal unit with all fittings wiring and accessories as per site requirements refer tender document for detailed description, overhauling and servicing of control panel including cleaning of relay base contacts racks and necessary maintenance work refer tender document for detailed description, 6 core 1 point 5 sq mm armoured copper signaling cable conforming to irs s 63 2014 specifications refer tender document for detailed description, excavation of trenches along track as per route plan including refilling after cable laying in specified soil conditions refer tender document for detailed description, laying of signaling telecom cables in trenches with proper depth route clearance and soil covering refer tender document for detailed description, termination of tail cables on main signals including wiring fixing lenses and required materials refer tender document for detailed description, termination of tail cables on shunt signals including wiring lenses fixing and associated work refer tender document for detailed description, supply of dwc hdpe pipes with couplers and o rings fire resistant and anti rodent as per rdso specifications refer tender document for detailed description, laying of dwc rcc pipes in trenches at track crossings roads and platforms including necessary fittings refer tender document for detailed description, dismantling existing signal posts and equipment and transporting them to designated scrap locations refer tender document for detailed description, repairing and overhauling of mechanical interlocking system including rollers brackets locking system lubrication balancing testing and commissioning refer tender document for detailed description


Agency / Dept : mumbai port trust MPT
Tender Value : 1399700
Due Date : May 22, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Soil Testing Equipment Repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Soil Testing Equipment Repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Soil Testing Equipment Repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Soil Testing Equipment Repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Soil Testing Equipment Repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Soil Testing Equipment Repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Soil Testing Equipment Repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Soil Testing Equipment Repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Soil Testing Equipment Repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Soil Testing Equipment Repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Soil Testing Equipment Repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Soil Testing Equipment Repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Soil Testing Equipment Repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Soil Testing Equipment Repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Soil Testing Equipment Repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Soil Testing Equipment Repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Soil Testing Equipment Repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Soil Testing Equipment Repair is declared L1 and is generally awarded the contract