Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Pipe hanger Tenders List

Latest Pipe hanger Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Pipe hanger tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Pipe hanger tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Pipe hanger Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Pipe hanger tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Pipe hanger Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Pipe hanger Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Pipe hanger Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Pipe hanger tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Pipe hanger Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Pipe hanger sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Pipe hanger tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Pipe hanger tenders.

Is EMD mandatory for all Pipe hanger tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Pipe hanger work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Pipe hanger tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Pipe hanger Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15894701
new Tender
Location : new delhi , delhi
Source : GEM Tenders
new Tender

tender for procurement of kbi spares connecting cable for anti skid valve make kbi , magnet valve of anti skid valve make kbi , compressor housing make kbi , minimum pressure valve make kbi , scavenge pipe make kbi , screw plug g1 by8a make kbi , screw plug g1 by4a make kbi , hexagonal nut m8 scavenge pipe make kbi , hexagonal nut m12 housing head make kbi , o ring thermostat stopper make kbi , stopper part no b89189 make kbi , o ring oil control block make kbi , stud m8x30 oil control unit kbi , hexagonal nut m8 oil control block make kbi , screw plug g3 by8a oil control block make kbi , adapter dome part no c66218 make kbi , gasket of main air compressor rs3 and rs9 make kbi , screw fitting part no c59093 by1 make kbi , oil pipe relief valve to compressor block make kbi , scroll casing part no i92325 by03 make kbi , admission ring part no b90701 make kbi , cooler cowl part no ii43792 make kbi , adapter housing part no ii45153 make kbi , reducing union compressor safety valve make kbi , oil drain valve part no i94700 by04 make kbi , screw plug g3 by8 cooler for radiator of main air comp rs3 and rs9 make kbi , stud m10x25 flange part no 452436 make kbi , screw plug g1a part no 451528 make kbi , compressor hub part no b91650 make kbi , setscrew m8x16 compressor hub part no 466661 make kbi , swivel t fitting part no c555142 by6 make kbi , screw fitting part no c54023 by14 make kbi , angle screw fitting part no c55556 by6 make kbi , screw fitting input to cooler part no c57324 by14 make kbi , pipe oil control unit to coller part no c66605 make kbi , pipe swivel t fitting to cooler part no c88709 make kbi , pipe oil control unit to swivelt fitting make kbi , angle screw fitting output from housing make kbi , compressed air pipe part no c66686 make kbi , screw fitting pressure switch part no c57324 by5 make kbi , angle screw fitting pressure switch make kbi , pipe housing to relief valve make kbi , angle screw fitting relief valve make kbi , screw plug g3 by8a compressor housing make kbi , screw plug g3 by4a compressor housing make kbi , protective grating part no c63211 make kbi , bracket two point mounting make kbi , bracket single point mounting make kbi , stud m10x25 resilient mounting make kbi , angle main air compressor make kbi , motor hub part no b91651 make kbi , setscrew m8x20 motor hub make kbi , cover dry type air filter make kbi , vane ring part no 8 000 8 923 720 4 make kbi , hexagonal nut dry type air filter make kbi , dust dischar valve part no 8 000 8 460 702 4 make kbi , air filter bracket part no ii41935 make kbi , holder dry type air filter part no c81101 make kbi , hose dry type air filter part no c70318 by2 make kbi , hose clamp dry type air filter make kbi , clamp part no c81114 by1 make kbi , electrical installation part no ii49776 make kbi , support part no ii14502 make kbi , temperature switch part no ii49742 by03 make kbi , closing parts part no i89979 by02 make kbi , washer 17 part no 450682 make kbi , rain hood part no b79455 by2 make kbi , elctromecanica part no stn3499 make kbi , connector for cab pneumatic valve 01008260 , duplex piston valve oem part no ii80663 oem kbi , anti skid valve gv 18 2 make kbi , check valve g3 by4 kb partno ii2556 make kbi , magnet valve part no i82554 by1110 make kbi , magnet valve wmv01 by5zg for rs 1 make kbi , l0wer guide rail assy left for saloon , air dryer unit byrs10 make kbi , main air compressor conditional oh kit for rs 3 make kbi , pressure reducing valve dmv 7 by7 5 make kbi , safety valve 15 bar part no ii40143 by8150 make kbi , lad03a card for becu byrs10 make kbi , kit for brake, connecting cable for anti skid valve make kbi, magnet valve of anti skid valve make kbi, compressor housing make kbi, minimum pressure valve make kbi, scavenge pipe make kbi, screw plug g1 by8a make kbi, screw plug g1 by4a make kbi, hexagonal nut m8 scavenge pipe make kbi, hexagonal nut m12 housing head make kbi, o ring thermostat stopper make kbi, stopper part no b89189 make kbi, o ring oil control block make kbi, stud m8x30 oil control unit kbi, hexagonal nut m8 oil control block make kbi, screw plug g3 by8a oil control block make kbi, adapter dome part no c66218 make kbi, gasket of main air compressor rs3 and rs9 make kbi, screw fitting part no c59093 by1 make kbi, oil pipe relief valve to compressor block make kbi, scroll casing part no i92325 by03 make kbi, admission ring part no b90701 make kbi, cooler cowl part no ii43792 make kbi, adapter housing part no ii45153 make kbi, reducing union compressor safety valve make kbi, oil drain valve part no i94700 by04 make kbi, screw plug g3 by8 cooler for radiator of main air comp rs3 and rs9 make kbi, stud m10x25 flange part no 452436 make kbi, screw plug g1a part no 451528 make kbi, compressor hub part no b91650 make kbi, setscrew m8x16 compressor hub part no 466661 make kbi, swivel t fitting part no c555142 by6 make kbi, screw fitting part no c54023 by14 make kbi, angle screw fitting part no c55556 by6 make kbi, screw fitting input to cooler part no c57324 by14 make kbi, pipe oil control unit to coller part no c66605 make kbi, pipe swivel t fitting to cooler part no c88709 make kbi, pipe oil control unit to swivelt fitting make kbi, angle screw fitting output from housing make kbi, compressed air pipe part no c66686 make kbi, screw fitting pressure switch part no c57324 by5 make kbi, angle screw fitting pressure switch make kbi, pipe housing to relief valve make kbi, angle screw fitting relief valve make kbi, screw plug g3 by8a compressor housing make kbi, screw plug g3 by4a compressor housing make kbi, protective grating part no c63211 make kbi, bracket two point mounting make kbi, bracket single point mounting make kbi, stud m10x25 resilient mounting make kbi, angle main air compressor make kbi, motor hub part no b91651 make kbi, setscrew m8x20 motor hub make kbi, cover dry type air filter make kbi, vane ring part no 8 000 8 923 720 4 make kbi, hexagonal nut dry type air filter make kbi, dust dischar valve part no 8 000 8 460 702 4 make kbi, air filter bracket part no ii41935 make kbi, holder dry type air filter part no c81101 make kbi, hose dry type air filter part no c70318 by2 make kbi, hose clamp dry type air filter make kbi, clamp part no c81114 by1 make kbi, electrical installation part no ii49776 make kbi, support part no ii14502 make kbi, temperature switch part no ii49742 by03 make kbi, closing parts part no i89979 by02 make kbi, washer 17 part no 450682 make kbi, rain hood part no b79455 by2 make kbi, elctromecanica part no stn3499 make kbi, connector for cab pneumatic valve 01008260, duplex piston valve oem part no ii80663 oem kbi, anti skid valve gv 18 2 make kbi, anti skid valve gv 18 2 make kbi, check valve g3 by4 kb partno ii2556 make kbi, magnet valve part no i82554 by1110 make kbi, magnet valve wmv01 by5zg for rs 1 make kbi, l0wer guide rail assy left for saloon, air dryer unit byrs10 make kbi, main air compressor conditional oh kit for rs 3 make kbi, pressure reducing valve dmv 7 by7 5 make kbi, safety valve 15 bar part no ii40143 by8150 make kbi, lad03a card for becu byrs10 make kbi, kit for brake hanger byrs 1 make-kbi


Tender Value : 26182576
Due Date : Jul 17, 2026
T18 Ref No : 15803432
live Tender
live Tender

Tender Value : 0
Due Date : Jun 22, 2026
T18 Ref No : 15602540
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

tender for 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp supply installation testing and commissioning , fp mcb 63 amp supply installation testing and commissioning , fp mcb 40 amp supply installation testing and commissioning , sp and n distribution board 12 way hvac idu , dp mcb 32 amp supply installation testing and commissioning , sp mcb 6 or 10 amp supply installation testing and commissioning , sfu 100a tpn at main switch board supply installation testing and commissioning , chemical earth electrode earthing arrangement supply installation testing and commissioning , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system, supply installation testing and commissioning of vrv type ac, supply and delivery of 14 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 20 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 24 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, installation testing and commissioning of 14 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 20 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 24 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, supply of 1.5 tr vrf 4 way cassette indoor unit with cooling capacity 12 kw and above power input 110 to 125 w airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature, supply of 4 tr vrf 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature as per specifications, installation testing and commissioning of 1.5 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, installation testing and commissioning of 4 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, supply of 3 tr split type direct expansion air conditioning system with 4 way ceiling mounted cassette indoor unit and matching air cooled outdoor unit hermetically sealed scroll compressor condenser and evaporator coil drain pump remote control suitable for 50 degree ambient, installation testing and commissioning of 3 tr split type cassette dx air conditioning system including mounting of indoor and outdoor units vibration isolation pads electrical termination control wiring drain piping nitrogen pressure testing vacuumization refrigerant charging and trial run, supply of centralized remote controller unit of same make as ac units for centralized control and monitoring of all connected vrf indoor and outdoor units complete with all accessories as recommended by manufacturer, installation testing and commissioning of centralized remote control unit for vrf system including all wiring connections configuration of connected indoor and outdoor units testing and commissioning complete as required, supply of 25.4 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 22.2 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 19 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 15.86 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 12.7 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 9.5 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, installation testing and commissioning including vacuumization and nitrogen testing of 25.4 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 22.2 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 19 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 15.86 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 12.7 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 9.5 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, supply of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer suitable for combination of indoor and outdoor machines for vrf system complete with all accessories, installation testing and commissioning of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer for vrf system complete with all accessories as required, supply and delivery of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, laying of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, supply of pvc condensate drain pipe of suitable size for ac indoor units with supports clamps and insulation as required complete with all accessories as per instructions, installation of pvc condensate drain piping for ac indoor units with supports clamps and all accessories as per site requirement and instructions complete as required, supply of ms table top stands for installing outdoor units vrf outdoor 10 units and dx outdoor 1 unit duly epoxy coated including supply of cowl piece for each outdoor machine as required, installation testing and commissioning of ms table top stands for outdoor units including installation testing and commissioning of cowl piece for each outdoor machine as required, supply and filling of refrigerant gas r410a as required for vrf and dx air conditioning systems complete with all accessories as per manufacturer recommendations and site requirements, supply of 4 core x 10 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, supply of 4 core x 16 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, laying testing and commissioning of 4 core x 10 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, laying testing and commissioning of 4 core x 16 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, providing fabricating and fixing aluminium anodized partition for air conditioning enclosure using approved aluminium sections with 15 micron anodized finish comprising fixed glazed panels and aluminium framed glazed doors with 5 mm clear float glass door shutters frames floor springs hinges handles locks rubber beading and all accessories, wiring in pvc casing and capping system using 2 x 1.5 sq mm fr pvc insulated copper conductor wire with modular type switches sockets surface mounting plastic frames for light point to be terminated in ceiling rose or batten or angle holder 6 amp 230 volts for led panel light fitting, supply and delivery of recess or surface mounted 2 x 2 luminaire 24 w with 150 lm per watt low glare and cri greater than 90 for hospital ward and corridor lighting as per instructions, installation testing and commissioning of led panel 2 x 2 24 watts to be installed at male and female ward and corridors of hospital as per instructions, supply and delivery of 4 core x 50 sq mm xlpe insulated armoured pvc sheathed heavy duty copper conductor cable 1100 volts grade conforming to is 1554 or is 7098 part 1 of 1988 complete as required, supply and delivery of galvanized iron wire size 8 swg for earthing and cable support as per specifications and instructions, installation charges for fixing and running armoured cables with copper conductors 1100 volts grade on even surfaced walls beams ceilings with appropriate gi saddles and gi spacers with gi wire from central switch chamber to ac power mcbdb at electrical switch room, cable end termination both ends for lv xlpe armoured 4 core x 50 sq mm cable including supply and fixing of double compression cable glands stripping of insulation tinned plated copper lugs for all phases crimping gi nut bolts and washers hdgi 80 micron one set per termination, supply installation testing and commissioning of three pole and neutral distribution board in sheet steel enclosure ip 43 powder coated double door horizontal surface or recess mounting with insulated tinned copper bus bars neutral links din channels earthing terminals 8 way 8 plus 24 way without mcb, supply installation testing and commissioning of four pole isolator 125 amp in suitable enclosure for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 63 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 40 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole and neutral consumer unit type distribution board in sheet steel enclosure powder coated single door with acrylic window surface or recess mounting with insulated tinned copper bus bar neutral link din channel 12 way 2 plus 10 way without mcb, supply installation testing and commissioning of double pole mcb 32 amp for hvac indoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole mcb 6 or 10 amp for hvac indoor unit distribution board as per specifications and instructions, supply delivery installation testing and commissioning of switch disconnector fuse unit sfu in sheet steel enclosure suitable for din type hrc fuses with isi mark 100amp tpn to be installed at main switch board in electrical switch room, supply installation testing and commissioning of chemical earth electrode for earthing complete with chemical powder 100 mm dia x 3 m long bore frp chamber 500 x 500 x 200 mm with frp cover earthing rod buried vertically 3 m deep resistance tested with calibrated earth resistance meter, comprehensive annual maintenance contract for air conditioning system first year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system second year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system third year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fourth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fifth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms


Agency / Dept : mumbai port trust MPT
Tender Value : 0
Due Date : Jun 25, 2026
T18 Ref No : 15792767
live Tender
Location : varanasi , uttar pradesh
Source : GEM Tenders
live Tender

tender for o and m with aicmc of hvac and vrv system at varanasi airport title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13 , title14 , title15 , title16 , title17 , title18 , title19 , title20 , title21 , title22 , title23 , title24 , title25 , title26 , title27 , title28 , title29 , title30 , title31 , title32 , title33 , title34 , title35 , title36 , title37 , title38 , title39 , title40 , title41 , title42 , title43 , title44 , title45 , title46 , title47 , title48 , title49 , title50, o and m with aicmc of hvac and vrv system at varanasi airport, operation and routine maintenance of water cooled chiller hvac system, 3x500tr i/c ahus and cooling tower, vrv system at various locations inside the terminal building and medical centre, various pumps and other installation of wtp and stp, ro, water coolers and split/tower/window ac units at various locations, water fountains inside the terminal building, ensuring serviceability/ satisfactory working condition of the systems i/c maintenance of records/logbook/ documents etc. on all days i/c saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following min. no. of man power- (a) supervisor (highly skilled) - 01 no. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 03 nos. (ie 01 no. round the clock on all days in every week for operation of chiller, reliever shall be provided on weekly off). (c) ac technician / mechanic (skilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of r.o., water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off). (d) asst. ac mechanic cum operator (semi skilled) - 09 nos. (i.e. 01 no. round the clock for operation of ahu, 01 no. round the clock for operation and maintenance of wtp, 01 no. round the clock for operation of stp on all days in every week, reliever shall be provided on weekly off). (e) asst. ac mechanic cum operator (semi skilled) - 01 no. (i.e. 01 no. in general shift for maintenance of stp, reliever shall be provided on weekly off). (f) helper (unskilled) - 03 nos. (i.e. 01 no. round the clock on all days in every week for hvac, reliever shall be provided on weekly off). (g) helper (unskilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of ro, water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off)., operation and routine maintenance of vrv system at ats cum technical block and precision air conditioning system at new mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) supervisor (highly skilled) - 01 nos. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 01 nos. (i.e. 01 no. in general shift on all days in every week for operation and routine maintenance of vrv system at ats cum technical block and pac system at new mssr building, reliever shall be provided on weekly off). (c) asst. ac mechanic cum operator (semi skilled) - 06 nos. (i.e. 01 no. round the clock for operation and routine maintenance of vrv system in ats block and 01 no. round the clock for operation and routine maintenance of pac system at new mssr building on all days in every week, reliever shall be provided on weekly off)., operation and routine maintenance of packaged air conditioning system at old mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) asst. ac mechanic cum operator (semi skilled) - 03 nos. (i.e. 01 no. round the clock for operation and routine maintenance of packaged air conditioning system at old mssr building on all days in every week, reliever shall be provided on weekly off)., annual all inclusive comprehensive maintenance contract of central ac plant (hvac) for 3x500tr (make- mcquay) centrifugal chiller type comprising of 3 no. cooling tower (make- advance) and 1no cooling tower (make- bell) with make-up tank, associated pumps as condenser water pump - 03 no(40hp), primary water pump - 03no (25hp), secondary water pump 12 hr - 03 no. (25hp), secondary water pump 24hr- 03 no. (15hp) with 06 no vfd with secondary pumps, hot water generator of 400kw (01 no) with in build panel for 8 zones , air handling unit (floor mounted) - 19 no. up to 100 tr and min 50tr capacity with 08 no vfds, ceiling suspended air handling unit - 17 no up to 3 to 5 tr with electrical starter panel in each hru 03 no of 4250 cmh, 4675 cmh, 2754 cmh with their electrical panels, ac risers - 82 no. with nozzles with respective ahus, ozone system of 06no of make- ruks canada ltd, electrical panel in plant room p1 , p2 and p3 for the operation of chillers, hot water generator and all associated pumps, water softening plant its electrical panel and pumps. above system complete including chiller pipe line, ac duct, grills diffusers, valves, gas charging, winding of motors, displays, instrumentations etc. complete as required related with hvac system. (the supply of consumable spares as mentioned in item-24 to 27 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive periodical maintenance of daikin make vrv system installed at new atc tower ,technical block and substation having total of 143 nos. vrv indoor units including ductable, high wall and cassette units of different capacities. total of outdoor units clubbed in 3 or 2 units together - 12 sets of total capacity of odu - 492 hp. maintenance work is inclusive of all spares required for repair, maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical equipment, safety controls and instrumentations, gas charging, fan , fan motors, thermal insulation, drain pumps, remote control console/units etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including saturday,sunday and holiday etc. as required., annual all inclusive comprehensive maintenance contract of 144hp vrv air-conditioning system installed in security hold area and passenger boarding bridge fixed finger (16hp - 09 set outdoor units model no-jrnu160lte5.apune, 4 tr- 16 set cassette type indoor units model number-jrnu48gtma4.apune, 6.3 tr - 04 set ductable type indoor units model number-jrnu76gb8a4.apune, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed in airlines/aai offices in departure area inside terminal building (20hp - 01 set outdoor units model no- ivrfb-20th, 1.7 tr- 10 set cassette type indoor units model number-vlc-20, makes-bluestar) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. upto 1.5 tr window/split ac, annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (2tr split/cassette/tower ac), annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (3.0 tr split/tower type ac), annual comprehensive maintenance of water coolers of all type, makes and capacities with providing necessary consumables, spares, compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers wherever connected etc. complete as required., annual comprehensive maintenance of water purifiers of aqua guard make including replacement of all defective components like uv lamp etc. and consumables and carrying out bimonthly servicing at installed position etc. complete as required.(the supply of consumable spares filters as mentioned in item no-40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro up to 50 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro above 50 up to 100 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39and40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), all inclusive comprehensive maintenance of 3 units each of 2x8tr capacity packaged air-conditioning plant installed at old mssr building (make - bluestar) including replacing defective components, carrying out preventive and breakdown maintenance like arresting of leakage, topping up of refrigerant gas, lubrication, rewinding/ replacing of all type of motors, repairing/ replacing of compressors, repairing / replacing of electrical components etc and other works required from time to time for proper maintenance of units including maintenance of records as per terms and condition all days including sundays and holidays., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at conference room and adjacent offices in terminal building including 2x 10hp outdoor units, 7x 2tr cassette type indoor units, make-daikin including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in passenger boarding bridge fixed link ( 1x 18 hp-02 set outdoor units model no-jrun180lls4, 4x 3tr-02set cassette type indoor units model number-rnu36gtna4, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 40hp vrv air-conditioning system installed in passenger boarding bridge fixed finger (1x 20hp-02 set outdoor units model no-jrun200lls4, 4x 3tr-02set cassette type indoor units model number-jrnu36gtna4 , makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in new fire station medical centre ( 3x 12 hp outdoor units, model no.-map1206ht8d-xa,cassette type indoor units 9x 2 tr, model no.- mmu-up0241hp-e and 3x1.5 tr, model no.-mmu-up0181hp-e make-toshiba) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of cold storage 40000 btu-02 set (make- bluestar) by providing quarterly visit and any number of break down as and when required including replacing/repairing compressor, condenser coil, temperature controller and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 3 x 15 tr (3 sets each of 01 no. indoor unit and 02 no. outdoor units) floor mounted, bottom discharge, top suction, air cooled dx type crac precision air-conditioning system units installed in new mssr building suitable to maintain equipment room temperature at 18 deg c plus minus 2 deg c (1x 15 tr - 03 set indoor units model no-pdx px054d, 2 no. x 03 set outdoor units model number-hcr-43 , makes-vertiv) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual comprehensive maintenance of drinking water fountain with chilling water fountain one at higher level and another at lower level to match disability compliance make oasis/haws/wae including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), cleaning of the solar module regularly two cycle in a month including minor repairing of tulu pump and monitoring of 600 kwp (500kwp+100kwp)grid connected roof top mounted solar photo voltaic power plant by deploying minimum one number unskilled man power in general shift excluding weekly off including maintaining records as per special conditions of the contract and as per direction of e-i-c. (consumables cleaning material like wiper duster, pvc flexible pipe etc. are to be provided by the agency. the solar module are under warrantee whereas inverter to be maintained by oem. the agency has to liaison with oem for repairing/replacement of defective parts)., supply of spares for hvac not include in cmc item no. 4 (pvc fills 600x300x150mm), supply of spares for hvac not include in cmc item no. 4 (resin 220 na(o) for softener plant), supply of spares for hvac not include in cmc item no. 4 (salt for softener plant), supply of spares for hvac not include in cmc item no. 4 (chlorine for dosing in stp), supply and installation of copper tubing of suitable size up to 3tr split air-conditioning for inlet and outlet of refrigerant gas complete with electrical cabling and insulation etc. complete as required during shifting of existing ac units., supply and installation of 20 mm dia pvc rigid drain pipe i/c all accessories like bends, couplers, tees etc. complete as required during shifting of existing ac units., supply and fixing of insulation of nitrile rubber in existing copper tubing for both inlet and outlet of existing installed air conditioner etc. complete as required during shifting of existing ac units as per direction of eic., dismantling of high wall split type air-conditioning unit, shifting, re-installation, testing and commissioning of capacity up to 3.00 tr air-conditioner units, fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required as per direction of eic., rewinding of 10/15 hp motor of submersible pump of (different stages ) different makes as per original size of insulated copper wire, sleeves complete with connection, interconnection etc as required., repairing of 10/15 hp submersible pump and motor (excluding rewinding of motor) of different stages and different makes i/c replacement of bearing bush, neck rings, bowl bush, running sleeve, key full, sand guard complete etc as required., repairing and rewinding of the existing water pump/ sewerage pump motor of capacity 0.75 hp to 3.0 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding, reinstallation the same, including testing and make the system in serviceable condition as required., repairing and rewinding of the existing blower motor/ filtered feed pump etc. of capacity 5 hp to 7.5 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding and reinstallation the same, including testing and make the system in serviceable condition as required., testing of stp incoming and treated water sample on quarterly basis from reputed govt. lab and submission of test reports as per technical specifications.(rate for each sample), dismantling, removal, lowering, reinstalling, testing and commissioning of submersible pumps of different makes and capacities including arranging of tripod stand, chain pulley block etc. as required., supply of 3.7 kw/ 5.0 hp submersible pump-motor set suitable for discharge 80mm delivery of minimum 250 lpm against static head 45mtr consisting of multistage pumps with suitable motor suitable for operation on 415 volt, 50 hz a/c supply. pumps and motors must be connected with alignment shafts etc. complete as required., supply of shield membrane which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-13,14 and 22 suitable for kent/ aqua guard/oasis/haws/wae up to 100 liter capacity etc. complete as required., supply of carbon / sediment filter which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-12,13,14 and 22 suitable for up to 100 liter capacity etc. complete as required., drinking water potability test quarterly basis as per technical specifications (rate for each sample)., supply of consumable urea for equalization tank of stp., supply of sand for sludge drying bed at stp., repairing/replacement of blower pipe tube at stp with suitable size pipe, elbow,socket and flange complete as required., supply of air blower filter at stp compatible to existing air blower., supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part -ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 300 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part- ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 250 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 200 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 150 mm dia, annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at pm safe house including 2x 10hp outdoor units with 6 x 2 tr, 2 x 1.5 tr and 1 x 1.1 tr high wall type indoor units, make-hitachi including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required.


Tender Value : 20741360
Due Date : Jul 03, 2026
T18 Ref No : 15750122
live Tender
Location : dabolim , goa
Source : GEM Tenders
live Tender

tender for centralied ac 14 hp outdoor unit , 1.3 tr , 1.5 tr , 2.0 tr , 3.0 tr , 3.5 tr , indoor outdoor y joints , remote controllers , 6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 3 core x 2.5 sq.mm for power supply of all vrf indoor units and scac outdoor units , 2 core x 1.5 sq. mm shielded for communication of vrf system , 4 core x 10 sq. mm , 20 mm , 150 mm width x 50 mm depth x 1.6 mm thickness , 300 mm width x 50 mm depth x 1.6 mm thickness , supply of 32 mm dia , supply of 40 mm dia , 3 inch x 3 inch c channel, supply of modular type variable refrigerant flow aircooled outdoor units suitable for cooling and heating, having 100 percentage hermetically sealed inverter type scroll compressor, supply of following minimum capacity 4-way flow vrf cassette type indoor ceiling mounted unit, supply of yor t or refnet or multi joints. joints shall be manufactured and supplied by same oem make as of odus and idus, supply of wireless remote controller with ir receivers for vrf individual indoor units., supply of following nominal sizes of soft or hard drawn copper refrigerant piping for vrf system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with xple class-o tubular insulation with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications, supply of following nominal sizes of soft or hard drawn copper refrigerant piping for vrf system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with xple class-o tubular insulation with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications, supply of following frls multi core control cables cum transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps/ supports, etc as reqd., supply of 4 core armoured pvc or xlpe insulated, pvc sheathed copper conductor cable of 1.1 kv grade with isi mark, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit, supplying and installing following size of perforated hot dipped galvenised iron cable tray withthickness not less than 50 microns with perforation not more than 17.5%, in convinient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including gi bolts & nuts, etc. complete as required., drain piping in hard pvc with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe., supply of ms fabricated outdoor units stand made up of c channel with proper first coat of zinc oxide and second coat of black colour oil based paint, installation, testing and commissioning of modular type variable refrigerant flow aircooled outdoor units suitable for cooling and heating, having 100 % hermetically sealed inverter type scroll compressor (s), minimum two compressors for above 14hp modules, installation, testing and commissioning of following minimum capacity 4-way flow vrf cassette type indoor ceiling mounted unit, installation, testing and commissioning of y or t or refnet or multi joints with required brazing, clamps & supports., installation, testing and commissioning of wireless remote controller with ir receivers for vrf individual indoor units., installation, testing and comissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for vrf system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with xple class-o tubular insulation with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications, installation, testing and commissioning of following frls multi core control cables cum transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or supports, installation, fixing and commissioning of following sizes of medium class pvc conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as required., installing and fixing following size of perforated galvenised iron cable tray with thickness not less than 50 microns with perforation not more than 17.5 percent, in convinient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including gi bolts & nuts, etc. complete as required., installation and testing of drain piping in hard pvc with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe., installation of ms fabricated outdoor units stand made up of c channel with proper first coat of zinc oxide and second coat of black colour oil based paint


Tender Value : 2355080
Due Date : Jun 30, 2026
T18 Ref No : 15823193
live Tender
Source : GEM Tenders
live Tender

Corrigendum Tender For OH of Main steam line valve V2 6 , OH of Steam by pass valve V2 27,15, and V2 7 , OH of ES 3,4,5,6 and 7 , OH of V2 -82-84 and V2-81-A to 81C , OH of HD-21, HD-29, HD-30 and HD-31 , OH of NRV of H.P. Heater and feed pump , OH of Group protection valve of HPH , OH of DW-4, 37,38,39,40,41 and CA 5 , OH of CST Makeup valve V6 60 , OH of AS-48 valve , OH of NRV of extraction line ES-8 , OH of suction valve of BFP , OH Condensate wtr throw off valve to condenser , OH throw off valve to cond and steam isolating of LPH2 , OH of Steam isolating valve of LPH 3, 4 , OH of Safety valve of aux PRDS or deaerator , OH of Safety valve of H.P. heater , OH of Safety valve of L.P. heater. , OH of Safety valve of CBD tank. , OH of Safety valve of flange or stud heatng , OH of Safety valve of warm up line. , Overhauling of actutator of AS 48 Valve , OH of Actr Feed line valveV2 81 or V2 82 or V2 83 or V2 84 , OH of Actr of V2 7 or V2 15 or V2 27 , OH of Actr Drip line valve and ext line valve , OH of Actr Valve connected to condenser , OH of Actr CST make valve , OH of Actr of MSV L and R , OH of Actr of steam isolating valve to LPH2 to 4 , OH of Actr steam throw off valve to condenser , CUT or WELD or REPL OF HP VALVE 15 to 50mm , CUT or WELD or REPL OF HP VALVE 51 to 100mm , CUT or WELD or REPL OF H P VALVE 101 to 150mm , OH of butterfly valve of condenser , OH of dea and FST with internal painting , Repair or replacement of broken hanger , Tightening of loose hangers , CUT or WELD or REPL OF L.P. VALVE 15 to 50mm , CUT or WELD or REPL OF L.P. VALVE 51 to 100mm , CUT or WELD or JOINT OF H.P. PIPE 15 to 50mm , CUT or WELD or JOINT OF H.P. PIPE 51 to 100mm , CUT or WELD or JOINT OF H.P. PIPE 101 to 150mm , CUT or WELD or JOINT OF H.P. PIPE 151 to 300mm , Lift or straight APRDS hdr by cutting weldding , O H of LPH 1A , 1B , O H of LPH 2 3 and 4 , OH and attend flange leakage of GC I or II , Clean of turbine oil or H2 Gas Cooler str , REPL OF DAMAGED SP. Valve V2 38 , REPL OF DAMAGED SPECIAL VALVE V2 27 , OH of turbine oil coolers , OH of main ejectors of turbine , OH of H.P. Heater , OH of LCV 3to15PCV-5, 14,16,17,TCV 8 , Repl bend of LP drip connected to Drip pump or Condenser , Cut damaged bend of HPH drip cont to dea , CUT WELD or REPL OF H.P. VALVE 151 to 300mm , Blank of CRH line for HT and normalizing , OH of H.P. Valve NRV in H.P. Line , OH of L.P. Valve NRV , OH of energy absorber of BFP , OH of DSS of Aux. PRDS., OH of valves during overhauling of unit 11, OH of Main steam line valve V2 6, OH of Steam by pass valve V2 27,15, and V2 7, OH of ES 3,4,5,6 and 7, OH of V2 -82-84 and V2-81-A to 81C, OH of HD-21, HD-29, HD-30 and HD-31, OH of NRV of H.P. Heater and feed pump, OH of Group protection valve of HPH, OH of DW-4, 37,38,39,40,41 and CA 5, OH of CST Makeup valve V6 60, OH of AS-48 valve, OH of NRV of extraction line ES-8, OH of suction valve of BFP, OH Condensate wtr throw off valve to condenser, OH throw off valve to cond and steam isolating of LPH2, OH of Steam isolating valve of LPH 3, 4, OH of Safety valve of aux PRDS or deaerator, OH of Safety valve of H.P. heater, OH of Safety valve of L.P. heater., OH of Safety valve of CBD tank., OH of Safety valve of flange or stud heatng, OH of Safety valve of warm up line., Overhauling of AS 48 Valve, OH of Actr Feed line valveV2 81 or V2 82 or V2 83 or V2 84, OH of Actr of V2 7 or V2 15 or V2 27, OH of Actr Drip line valve and ext line valve, OH of Actr Valve connected to condenser, OH of Actr CST make valve, OH of Actr of MSV L and R, OH of Actr of steam isolating valve to LPH2 to 4, OH of Actr steam throw off valve to condenser, CUT or WELD or REPL OF HP VALVE 15 to 50mm, CUT or WELD or REPL OF HP VALVE 51 to 100mm, CUT or WELD or REPL OF H P VALVE 101 to 150mm, OH of butterfly valve of condenser, OH of dea and FST with internal painting, Repair or replacement of broken hanger., Tightening of loose hangers., CUT or WELD or REPL OF L.P. VALVE 15 to 50mm, CUT or WELD or REPL OF L.P. VALVE 51 to 100mm, CUT or WELD or JOINT OF H.P. PIPE 15 to 50mm, CUT or WELD or JOINT OF H.P. PIPE 51 to 100mm, CUT or WELD or JOINT OF H.P. PIPE 101 to 150mm, CUT or WELD or JOINT OF H.P. PIPE 151 to 300mm, Lift or straight APRDS hdr by cutting weldding, O H of LPH 1A , 1B, O H of LPH 2 3 and 4, OH and attend flange leakage of GC I or II, Clean of turbine oil or H2 Gas Cooler str, REPL OF DAMAGED SP. Valve V2 38, REPL OF DAMAGED SPECIAL VALVE V2 27, OH of turbine oil coolers, OH of main ejectors of turbine, OH of H.P. Heater, OH of LCV 3to15PCV-5, 14,16,17,TCV 8, Repl bend of LP drip connected to Drip pump or Condenser, Cut damaged bend of HPH drip cont to dea, CUT WELD or REPL OF H.P. VALVE 151 to 300mm, Blank of CRH line for HT and normalizing, OH of H.P. Valve NRV in H.P. Line, OH of L.P. Valve NRV, OH of energy absorber of BFP, OH of DSS of Aux. PRDS.


Tender Value : 1097788
Due Date : Jun 22, 2026
T18 Ref No : 15861863
live Tender
Source : GEM Tenders
live Tender

corrigendum tender for oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia, oh of valves during ovehauling of unit 10, oh of main steam line valve v2 6, oh of steam by pass valve v2 27,15, and v2 7, oh of es 3,4,5,6 and 7, oh of v2 -82-84 and v2-81-a to 81c, oh of hd-21, hd-29, hd-30 and hd-31, oh of nrv of h.p. heater and feed pump, oh of group protection valve of hph, oh of dw-4, 37,38,39,40,41 and ca 5, oh of cst makeup valve v6 60, oh of as-48 valve, oh of nrv of extraction line es-8, oh of suction valve of bfp, oh condensate wtr throw off valve to condenser, oh throw off valve to cond and steam isolating of lph2, oh of steam isolating valve of lph 3, 4, oh of safety valve of aux prds or deaerator, oh of safety valve of h.p. heater, oh of safety valve of l.p. heater., oh of safety valve of cbd tank., oh of safety valve of flange or stud heatng, oh of safety valve of warm up line., overhauling of as 48 valve, oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84, oh of actr of v2 7 or v2 15 or v2 27, oh of actr drip line valve and ext line valve, oh of actr valve connected to condenser, oh of actr cst make valve, oh of actr of msv l and r, oh of actr of steam isolating valve to lph2 to 4, oh of actr steam throw off valve to condenser, cut or weld or repl of hp valve 15 to 50mm, cut or weld or repl of hp valve 51 to 100mm, cut or weld or repl of h p valve 101 to 150mm, oh of butterfly valve of condenser, oh of dea and fst with internal painting, repair or replacement of broken hanger., tightening of loose hangers., cut or weld or repl of l.p. valve 15 to 50mm, cut or weld or repl of l.p. valve 51 to 100mm, cut or weld or joint of h.p. pipe 15 to 50mm, cut or weld or joint of h.p. pipe 51 to 100mm, cut or weld or joint of h.p. pipe 101 to 150mm, cut or weld or joint of h.p. pipe 151 to 300mm, lift or straight aprds hdr by cutting weldding, o h of lph 1a , 1b, o h of lph 2 3 and 4, oh and attend flange leakage of gc i or ii, clean of turbine oil or h2 gas cooler str, repl of damaged sp. valve v2 38, repl of damaged special valve v2 27, oh of turbine oil coolers, oh of main ejectors of turbine, oh of h.p. heater, oh of lcv 3to15pcv-5, 14,16,17,tcv 8, repl bend of lp drip connected to drip pump or condenser, cut damaged bend of hph drip cont to dea, cut weld or repl of h.p. valve 151 to 300mm, blank of crh line for ht and normalizing, oh of h.p. valve nrv in h.p. line, oh of l.p. valve nrv, oh of energy absorber of bfp, oh of dss of aux. prds., 2coat paint bcw,clr,bfp,cep,drip pump and line, 2coat paint cst,bcw pump ,swc tank,line,valve, 2coat paint hcplg,sw,bcw,cw exc clr line, 2coat paint air washer sys,cep or phos or hyd coupling, 2coat spray paint syn super enamel lpc, 2coat spray paint front ped,barring gear, 2coat spray paint brg and housing turbine, 2coat spray paint cntl valve casing, 2coat spray paint condenser and line, 2coat spray paint main oil tank, 2coat spray paint main ejector, 2coat spray paint centrifuging machine, 2coat spray paint lube oil cooler, letter writing 2 inch size dia


Tender Value : 1456902
Due Date : Jun 24, 2026
T18 Ref No : 15864744
live Tender
Source : GEM Tenders
live Tender

corrigendum tender for ordinary portland cement grade 43 , stone aggregate shall be crushed stone 20mm , coarse sand , stone aggregate shall be crushed stone 40mm , rr stone , tmt steel bar 16mm dia , tmt steel bar 12mm dia , tmt steel bar 10mm dia , tmt steel bar 8 mm dia , binding wire 20 gauge 0 point 9mm , shuttering water proof plywood of size 8 feet x 4 feet and 12mm thickness , nails 2 inch , nails 3 inch , nails 5 inch , quick setting , 2nd class hardwood plain fillets , wooden ballies 75mm to 100 mm , pbs roll , bitumen or blown type , water proofing compound , hdpe film of 400 micron , loop hole of size 2130 x 1067 mm , wooden scantling 3 point 20m , steel door of size 900x1800 mm , lightning conductor , 8 pin cloth hanger , ms round pipe 150mm dia , ms round pipe 20mm , pre painted galvalume aluminum zinc coating gi based corrugated steel sheet 0 point 60mm thick , 75mm dia pvc pipe for weep hole make supreme or kissan or prince , ms plate 10 mm , ms plate 20 mm , shredded rubber 150 mm , pvc single core 1 point 5 sqmm , pvc single core 2 point 5 sqmm , cable pvc insulated and pvc 1100v grade , pvc conduit pipe round shape 50 mm dia and 3 point 00 mm , pvc l bend for 20 mm conduit pipe , pvc t 20 mm for conduit pipe , pvc square box 4 inch x 4 inch , pvc elbow 20 mm dia , dry wall screw 50 mm , mcb single pole 230v , switch piano flush type15 amp , pvc ceiling rose 2 or 3 terminal , insulation tape 25 mm , distribution box mcb box 12 way , stainless steel u clamp for 20 mm pvc conduit pipe , isolator 63 amp dp , earthing of building provided using 3 mm dia , tmt steel bar 16mm , tmt steel bar 12mm , tmt steel bar 10mm , tmt steel bar 8 mm , quick setting compound , bitumen , hdpe film of 400 micron thickness , synthetic enamel paint colour , turpentine oil , loop holes of size 600 x 500mm , steel door of size 900 x 1800 mm , lightning conductor made of copper tube 150 cm long x 25mm , ms plate 10 mm for roofing layer , ms plate 20 mm for roofing layer , 75mm dia pvc pipe for weep hole , cable pvc insulated and pvc 1100v , pvc conduit pipe round shape 50 mm , dry wall screw 50 mm long , insulation tape 25 mm width 9 mtr , distribution box mcb box 12 way factory made , isolator 63 amp dp make anchor or havells or phillips , earthing of building provided using 3 mm , stone aggregate shall be crushed stone 10mm to 12mm , coarse sand , supply and installation and testing of solar hybrid power plant of capacity 5kw bracket open 2 kw wind turbines and 3 kw solar bracket close, 04 x adl, store list items to be supplied as per technical specifications mentioned in pdf document, electric items to be supplied as per technical specifications mentioned in pdf document


Tender Value : 0
Due Date : Jun 20, 2026
Published By