Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

11Results forLatest Floor covering repair Tenders List

Latest Floor covering repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Floor covering repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Floor covering repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Floor covering repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Floor covering repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Floor covering repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Floor covering repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Floor covering repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Floor covering repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Floor covering repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Floor covering repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Floor covering repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Floor covering repair tenders.

Is EMD mandatory for all Floor covering repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Floor covering repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Floor covering repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Floor covering repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15247132
Location : new delhi , delhi
Source : GEM Tenders

tender for operation of microprocessor based hvac system , all inclusive comprehensive maintenance , replacement of damaged and worn out control and power wiring , dismantling and replacement of existing faulty 2 amp dp mcb , dismantling and replacement of existing faulty mpcb ms 116 , replacement of burnt broken and rusted terminal block , dismantling and replacement of following sizes of existing worn out faulty pipe 200mm dia 32 mm thick insulation , 150mm dia 32 mm thick insulation , 125mm dia 32 mm thick insulation , 100mm dia 32 mm thick insulation , 80mm dia 32 mm thick insulation , 65mm dia 32 mm thick insulation , dismantling and replacement of following sizes of existing worn out ndustrial type pressure gauges , providing and fixing in position the mercury in glass industrial type thermometers , butterfly valve manual with c i body ss disc a 150 mm dia , 100 mm dia , dismantling and replacement of following existing worn out faulty tpmccb 100 a 16 ka tpmccb , 200 a 25 ka tpmccb , 630 a 50 ka tpmccb , 800 a 50 ka tpmccb , making suitable modification replacement of overheated existing aluminium bus bar , dismantling and replacement of existing worn out faulty paddle type water flow , attending leakage in the existing chilled water pipeline , replacement of the following items of existing electrical panels mnx 32 contactor make l andtac plant room , mnx 25 contactor make l andt , 2noplus2 nc add on blockmake l andt , overload relay mn 2 of range 9 to 15 amps make l andt , single phase preventer , on off push button with elements , led indication lampr y b g , 3 way selector switch , star delta timer , digital voltmetermake select or ss , digital ammeter make select or ss , v belt , painting of existing old electrical panel, om hvac bsb janpath nd, operation of microprocessor based hvac system of capacity 5 x 100 tr chilling machines with screw compressors and air cooled condensers as detailed in annexure a and ductable tower type split ac and split ac as detailed in annexure b by deputing the following staff skilled semi skilled unskilled 6 am to 2pm 1 1 2 2 pm to 10 pm 1 1 2 general shift 9 am to 5 pm 1 0 0 notes 1 staff may be asked to work in any shift and any day without any extra cost 2 bill processed receipt proof online salary transfer account epf esi contr presently 12 perct and 3 25 perct ofpay respas reqt 3 if esi and epf contributions rescission work initiated 4 staff deployed enrolled attendance system 5 the contractor ensure personnel meet defined standards f 6 operation of the pumps 7 operation of ahus and tfa 8 oper electrical panels 9 recording readings chillers ahus pumps digital temperature meter 10 to attend the floor complaints 11 weekly washing ahus filters and ahus room 12 chemical cleaning ahus cooling coil 13 general checking testing and attending minor faults 14 out of skill manpower one skill operator electrician 15 to carry out leak test compressors condenser coil with soap items are as per schedule of work item 1, all inclusive comprehensive maintenance of following items as per inventory at per annexure b given in relevant sections up to the required standards etc as per specification the items are 1 ductable ac units 2 tower split ac units 3 split ac units items are as per schedule of work item 2, replacement of damaged and worn out control and power wiring of star delta starter panel for one motor in existing ahus electrical panel with new pvc insulated copper conductor wires of suitable size including providing and fixing of thimbles ferrules and new insulated fiber sheet for proper insulation removing of existing contactors cleaning and re fixing the same in position after proper checking and tightening of all connections complete as required items are as per schedule of work item 3, dismantling and replacement of existing faulty 2 amp dp mcbs in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 4, dismantling and replacement of existing faulty mpcb ms 116 in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 5, replacement of burnt broken and rusted terminal block 63 amp rating along with 2 nos lugs in the existing electrical panel of ahu s chilled water pump s etc complete as required items are as per schedule of work item 6, dismantling and replacement of following sizes of existing worn out faulty pipe at different floors levels i c supplying laying fixing testing and commissioning of nominal sizes of chilled water piping inside the building with necessary clamps vibration isolators and fittings but excluding valves strainers gauges etc duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg cu m density thermal conductivity 0 037 w mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc as per specifications and as required complete in all respect note the pipes of sizes 150mm and below shall be m s c class as per is 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is 3589 from minimum 6 35mm thick m s sheet for pipes upto 350 mm dia and from minimum 7mm thick ms sheet for pipes of 400 mm dia and above a 200mm dia 32 mm thick insulation items are as per schedule of work item 7 a, 150mm dia 32 mm thick insulation items are as per schedule of work item 7 b, 125mm dia 32 mm thick insulation items are as per schedule of work item 7 c, 100mm dia 32 mm thick insulation items are as per schedule of work item 7 d, 80mm dia 32 mm thick insulation items are as per schedule of work item 7 e, 65mm dia 32 mm thick insulation items are as per schedule of work item 7 f, dismantling and replacement of following sizes of existing worn out faulty components at different floors levels i c supplying fixing testing and commissioning of valves gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications 8 1 providing and fixing in position the industrial type pressure gauges with gun metal brass valves complete as required items are as per schedule of work item 8 1, providing and fixing in position the mercury in glass industrial type thermometers items are as per schedule of work item 8 2, butterfly valve manual with c i body ss disc nitrile rubber seal and o ring pn 16 pressure rating for chilled water hot eater circulation as specified a 150 mm dia items are as per schedule of work item 8 3 a, 100 mm dia items are as per schedule of work item 8 3 b, dismantling and replacement of following existing worn out faulty tpmccb at different floors levels i c fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections ics100 perc icu and operational voltage 690v etc as required 100 a 16 ka tpmccb items are as per schedule of work item 9 a, 200 a 25 ka tpmccb items are as per schedule of work item 9 b, 630 a 50 ka tpmccb items are as per schedule of work item 9 c, 800 a 50 ka tpmccb items are as per schedule of work item 9 d, making suitable modification replacement of overheated existing aluminium bus bar links suitable to fit 630 800ampcapacity tp mccb i c cutting bending pvc sleeving testing commissioning etc complete as per site requirement items are as per schedule of work item 10, dismantling and replacement of existing worn out faulty paddle type water flow switch at different floors levels i c installation testing and commissioning with micro switch contacts and retard mechanism complete in all respects as required items are as per schedule of work item 11, attending leakage in the existing chilled water pipeline of various diameters including cutting of damaged portion edge preparation welding testing and making the pipeline operational including providing and fixing necessary scaffolding ladders safety arrangements for working at heights ranging from 15 feet to 100 feet in shaft area cleaning the pipe surface applying anti corrosive paint on welded joints and restoring the system to its original condition complete as required items are as per schedule of work item 12, replacement of the following items of existing electrical panels i c identifying and rectifying the fault dismantling of existing defective parts fixing connections testing etc as required a mnx 32 contactor make l andt ac plant room items are as per schedule of work item 13 a, mnx 25 contactor make l andt items are as per schedule of work item 13 b, 2noplus2 nc add on block make l andt items are as per schedule of work item 13 c, overload relay mn 2 of range 9 to 15 amps make l andt items are as per schedule of work item 13 d, single phase preventer items are as per schedule of work item 13 e, on off push button with elements items are as per schedule of work item 13 f, led indication lamp r y b g items are as per schedule of work item 13 g, 3 way selector switch items are as per schedule of work item 13 h, star delta timer items are as per schedule of work item 13 i, digital voltmeter make select or ss items are as per schedule of work item 13 j, digital ammeter make select or ss items are as per schedule of work item 13 k, v belt items are as per schedule of work item 13 l, painting of existing old electrical panel without dismantling including masking covering of indicators meters switches surface cleaning rust removal 1 coat red oxide primer plus synthetic enamel spray paint and finishing etc as required items are as per schedule of work item 14


Tender Value : 7391777
Due Date : May 19, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15286275
Source : GEM Tenders

tender for xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply, installing, testing and commissioning of pdb panel 800a, 415v. the panel shall be indoor wall mounted. it shall be completely made of crca sheet steel. , supply, installing, testing and commissioning of pf correction panel with rms 430kvar, 415v. panel indoor floor mounted, free standing with ip-31 degree of ip made of crca sheet steel. , material and labour for xlpe insulated, lt armoured electric sense cable with aluminiur star ded conductor 1100 volts grade, cross- sectional area 4 sqmm, 6 core , m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed , supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying cif cables, pipe lines, protection pipes , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed , material and labour for earthing complete with copper plate electrode 600mmx 600mmx. 3.1.5 mm thick buriel directely in ground vertically , supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , civil work rcc panel base slab size - 2000mm l x 1300mm w x 150mm thickness , warranty service amc by cmc including breakdown service for 1 year to ensure the safe, reliable, and efficient operation of the electrical panel, provision of solar factor correction for 1 mw solar plant, the enclosure shall have sturdy support structure with angle suppors as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the panel shall be suitably sized to accommodate all the compor ents, providing necessary air clearance between live and non-live parts, providing necessary working clearance. incomer shall pe al busbars. power outgoing shall be one 800a, 415v, 50ka, tp, mccb, tm. bus bar shall be of aluminium with 0.8a by sq. mm current dens ty. suitable indication lamps for - phase supply indication and circuit elreaker - trip indication should be provided. mccbs shall be with door inter ocking protection systems. bus bars shall have coloured pvc sleeves. 800a outgoing shall be used to feed the 430kvar, 415v step-less pf correction system complete all as specified anc directed, the enclosure shall have sturdy support structure with angle supports as necessary. enclosure shall be finished with powder coating, after finishing 10 tanks chemical treatment. paint shed shall be ral-7035. suitable provisions shall be made in the panel for proper heat dissipation. air aspiration louvers for proper air circulation shall be provided as necessary. the step-leiss pf correctior panel system shall be without any pf correction passive capacitor banks, but single or mutiple module combination of static var generator, which can measure the actual requirement of reactive currents and produce and inject the same reactive currents inductive or capacit ve as per the system needs to compensate the reactive power demand individual phase -wise. there shall be one hill cum svg controller digital signal processor to sense the load current and operate the svg modules connected with the svg panel. reaction time of that dsp shall be 10 msec, so that cycle to cycle compensation to be established. the hmi display unit shall have 15channel oscilloscope to display live-status of the 3phase voltage, load current, grid current and svg currents, along with all major electrical pq parameters. svg modules should have efficiency of less than 98 percent and internal losses 2 percent of its full capacity. the svg modules shall have internal fan for heat dissipation by force air cooling method. maximum 50 no.s modules can be connected in parallel per ct set. the svg modules should be operated within the voltage range 350v to 480v. ambient temperature should be 0-45 temp c. noise level shall be 5db. built-in semiconductor-fuse protection for the svg modules is a must. load ct shall have 5a secoridary and in general it will be connected in close loop. full rating of individual static var generator moclule shall be 125kvar, 480v, 1504, which will output 107.8kvar at 415v ac. so, considering the 4nos of modules it will output 431.2kvar at 415v., laid in trenches by pipes by ducts by wall by boarings with necessary cable lugs and glands, nuts, bolts and washers etc and test ng complete all as specified and directed, m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed, supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover complete all as specified in ssr part-l and as directed, foundations etc and getting out in soft loose soil complete all as specified and directed., returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed, remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres belcw ground level, connected to and including coper strip of size 20 x 3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-l and gl watering pipe of 20 mm dia medium grade, gi funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1-3-6 lype c1, rcc cover 1-2-4 type b1, ncluding excavation by earth work in any strata and returning filling, removal of surplus soil anc testing for required value complete all as specified and directed., supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed, concrete grade -m25 mix ratio 1-2-1 - cement- sand- aggregate bot om reinforcement 12mm dia. tmt bars placed at - 150mm centre-to-centre spacing in both directions both ways top reinforcement- 10mm dia. tmt bars placed at 200mm centre-to-centre spacing in both directions both ways edge stirrups 8mm dia tmt bars placed at 200mm centre-to-centre spacing in both directions both way formwork proper shuttering to be provided to achieve specified dimensions and line and level. total load 700kg or 6.9kn. cable trench 300mmx300mm and ms chequered plate cover for trench. base plate- ms charinel by flat ismc 100 or 10mm thick plate. curing - minimum 7 cays of water curing or as per is 4-56 recommendat ons plastering over base slab plaster mix cement mortar 1-6 - cement- sand finish- surface to be finished with neat cement punning after plastering as required preparation surface to be cleaned and wetted before application. proper bonding and uniformity to be ensured cutting and mending in brick wall scope- cutting holes in brick walls for service entries pipes, cables, etc. maximum diameter up to 150mm mending work- all damages to be made good using cement mortar cernent consumption approx. 4 kg per meter of hole length as per estimate restoration to match existing finish plaster or paint, its associated systems through periodic inspection, testing, servicing, and emergency support over a period of one year after one year dlp duration one 1 years from the date of completion of dlp. services included scheduled quarterly site visits, visual inspection for overheating, corrosion, physical damage, cleaning of preventive maintenance panels dust, debris, moisture control, tightening of connections and torque testing of terminals, megger testing of insulation resistance, functional test of breakers and rcds corrective maintenance fault finding and diagnosis for reported issues, replacement of defective components, repair of wiring or damaged insulation, troubleshooting tripping or overloads emergency support on-site visit within 48 hours of call define sla clearly documentation and reporting maintenance logs and service reports after each visit annual performance summary report


Agency / Dept : indian army
Tender Value : 0
Due Date : May 18, 2026
T18 Ref No : 15327818
Source : GEM Tenders

tender for spl repair for replacement of 2 transformer against ber transformers cable termination kit suitable for cables up to and including 33 kv (v2) (q3) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply installation testing commissioning of step down transformer voltage rating ht11 bye 0. 433 kv out door type of capacity 250 kva level 2 3 phase 4 wire 50 hz , supply, installation , testing and commissioning of step down transformer voltage rating ht11 by 0.433 kv, out door type of capacity 315 kva level 2, 3 phase, 4 wire,50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core.complete all as specified and directed in boq spec file , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , material and labour for earthing complete with copper plate electrode 600mmx 600mmx 3.15 mm thick buried directely in ground vertically.complete all as specified and directed in boq spec file , m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file , boaring holes horizontally under road without damaging the surface of road minimum1.0 mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable. , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file , disconnected all electrical connections and earth strip at existing transformerall connected accessories by cables and shifting of 11 kv by 0.433 volts 200 kva to 315 kva capacity transformer., spl repair for replacement of 2 transformer against ber transformers, oil cooled core type floor mounted delta bye star connected maximum losses as defined in vector group dyn 11 double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 250 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories guages first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639 to 1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings bye accessories fitted complete all as specified and directed, oil cooled, core type, floor mounted, delta by star connected maximum losses as defined in vector group dyn 11, double copper wound onan manual type off load tap changing facility on ht side to vary secondary voltage from minus 7.5 percent to plus 7.5 percent in steps of 2.5 percent continuous rating of capacity 315 kva incl cable box on both ht and lt side the transformer shall be completed with all standard fittings and accessories, guages, first fill transformer oil as as per indication level etc and confirming to is1180 and fittings and accessories of transformers shall confirm to is 3639-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fitting by accessories fitted complete all as specified and directed., insulated screened pvc bedded galvanized steel strip or wire armoured electric power cables heavy duty with standard aluminium conductor 11000 volts earth garde of cross sectional area 3 core 120 sqmm completed all specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 matres below ground level connected to and including galvanised iron strip of size 32 x 6 mm from earth earth electrode to test point bye equipment or up to 7.5 metres whichever is less by means of gi bolts nuts, check nuts and washers all as per electrical plate no 3 of ssr pt 1 and gl watering pipe of 20 mm dia medium grade gi funnel with wire mesh including charcoal salt packed all around the earth electrode plate in layers pcc earth pit chamber 1 ratio 3 ratio 6 type c1 rcc cover 1 ratio 2 ratio 4 type b1 including all excavation bye earth work in any strata and returning filling removal of surplus soil and testing for required value complete all as specified and directed, earth pit not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metres below ground level, connected to and including coper strip of size 20x3 mm from earth electrode to test point by equipment or up to 7.5 metres whichever is less by means of bolts, nuts, check nuts and washers all as per electrical plate no 3 of ssr pt-i and gl watering pipe of 20 mm dia medium grade, gl funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, pcc earth pit chamber 1 ratio 3 ratio 6 type c1,rcc cover 1 ratio 2 ratio 4 type b1, including excavation by earth work in any strata and returning filling, removal of surplus soil and testing for required value, m and l for brick sub class b, 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cable complete all as specified and directed in boq specification file, supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in ssr part i and as directed, excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed in boq spec file, returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed in boq spec file, removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed in boq spec file, m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed in boq spec file, boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable all as specified and as directed, supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed in boq spec file, transportation safely by hydra by lifting vehicle including providing suitable carrying vehicle to proposed power houses or mes yard as per suitable directions of engr-in-charge and making all electrical connections properly with earth strip etc and to be re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such nuts, bolts, washers, lugs, sleevs etc and megger testing and complete all as specified and directed in boq spec file


Agency / Dept : indian army
Tender Value : 0
Due Date : May 21, 2026
T18 Ref No : 15875280
Location : ajmer , rajasthan
Source : GEM Tenders

tender for transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , transportation charges up to 50 km for alternator up to 55 kva , transportation charges more than 51 to 100 km for alternator up to 55 kva , rewinding of main stator winding of alternator up to 20 kva , rewinding of main rotor winding of alternator up to 20 kva , rewinding of main stator winding of alternator more than 20 kva and upto 55 kva , rewinding of main rotor winding of alternator more than 20 kva and upto 55 kva , exciter stator winding of alternator up to 55 kva , exciter rotor winding of alternator up to 55 kva , replacement or repairing of avr , replacement or repairing of power diode for rotating rectifier assembly , replacement or repairing of bearing suitable for above 20 kva alternator , providing of 2 core 16 sqmm , providing of 4 core 16 sqmm , laying of one no upto 35 sq. mm on wall surface , laying of one no upto 35 sq. mm direct in ground , laying of one no upto 35 sq. mmin the existing rcc or hume or metal pipe , supply and making end termination for 2 x 10 sq. mm 19 mm , supply and making end termination for 4 x 16 sq. mm 28 mm , providing and fixing 6 swg dia g.i. wire , supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch , supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch , providing and fixing 63 amp tpn disconnector fuse switch unit , repairing of fuel injection pump fip, nozzle and injectors ,, rc for repairing servicing shifting of dea sets at hub sites under ba udaipur, visit charges to attend fault of dea set on call basis / complaint basis on behalf of written job order from sde(e) concerned for different te / bts sites under jurisidication including attending the minor faults involving no material and submit detailed report for major fault to the engineering -in-charge i/c fare charges to visit the site from hq etc complete as reqd., pdg & making of general servicing of the up to 20 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 20 kva & upto 32.5 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., pdg & making of general servicing of the more than 32.5 kva & up to 55 kva dea sets of different make and model installed at te/bts sites comprising of following jobs i/c fare and labour charge i/c complete checking of e/a set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd., replacement of diesel filter element set ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1/2 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter element ( 1 ltr ) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of oil filter set suitable for e/a set of 50/55 kva in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of lubricating oil multi grade ( 20w40) in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of steel wire braided fuel pipe line in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of stop solenoid 12 volt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of starting key with switch in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of mechanical type rpm cum hr meter chain in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of battery leads red & black standard length & size i/c terminals in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of coolant for radiator of superior quality or as recommended by manufacturer in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of v-belt in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of hose pipe set with clips in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of techo drive unit in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of fuel feed pump assembly in existing different capacity and make of engines i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of solid state smps or scr based battery chargers in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of push button switch for start/ stop/reset in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), replacement of 12 v dc / 220 v ac hr meter counter type in existing different capacity and make e/a set amf / manual control panels i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( note- make and model as per manufacturer recommendation ), supplying & fixing of 12 volt battery operated self starter suitable for starting of engine i/c fixing the same on the dg set making connections testing etc. complete as reqd. ( make- autolek or similar superior make), supplying & fixing of 12 volt battery charging alternator on the existing dg set i/c making connections testing etc. complete as reqd. ( make -autolek or similar superior make), repairing and servicing of the 12 volt battery charging alternator for dg set i/c greasing, oiling, making connections testing etc. complete as reqd., repairing & general servicing of the existing faulty radiator up to 55 kva diesel engine alternator set by repairing of leakage and cleaning of copper tubes with help of cleaning agents, dismentling of radiator assembly including transportation, brazing and testing for leakage and re-installation after repairing the same etc. reqd., pdg general servicing and repairing of 12 volts engine starting self that i/c dismentalling of equipments, greasing and oiling of bearing and other parts , cleaning of self with petrol , replacement of carbon brush , housing etc. complete checking of self and testing and fixing with proper alignment with gears etc complete as reqd., dismentalling of existing up to 20 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., dismentalling of existing more than 20 kva & upto 55 kva dea sets in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc. set from existing position of te / bts site under ed jaipur etc. and reparing of any damage during dismentling by making good the same etc. complete as reqd., extra for shifting of existing dea set up to 20 kva capacity from rooftop of the building to ground floor / loading vehicle with the help of chain pulley / crane by ensuring safety to the existing construction at site and reparing of any damage during shifting / dismentling by making good the same etc. complete as reqd., loading of existing up to 20 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., loading of existing more than 20 kva & upto 55 kva dea sets from ground floor to loading vehicle with the help of chain pulley / crane / man power etc. complete as reqd., transportation of up to 20 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., transportation of more than 20 kva & upto 55 kva dea sets along with all accessories etc from te / bts site of ssa under ed jaipur to store / any place in same ssa as directed by engg. in charge by transport by truck / loading vehicle etc. complete as reqd., unloading of existing dea sets of up to 20 kva dea sets from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., unloading of existing dea sets of more than 20 kva & upto 55 kva dea from loading vehicle to place of shifting / store along with all accessories etc as directed by engg. in charge with the help of chain pulley / crane / man power etc. complete as reqd., installation, testing and commissioning of existing dea sets of up to 20 kva dea sets on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., installation, testing and commissioning of existing dea sets of more than 20 kva & upto 55 kva dea on existing foundation / floor at site along with canopy & all other accessories i/c making connections, power and control cable, earthing connections etc. complete as per requirement at site., labour charges for top overhauling of existing dea sets up to 20 kva capacity i/c dismentalling of all parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safties, meters if reqd and calibration of engine as per manufaturer reccommendations., replacement of the liner assembly with rubber ring in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts, testing etc as reqd., replacement of the piston set without piston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thepiston ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the set of gasket i/c head gasket in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the o ring set in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of thecr bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the main bearing in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the oil pressure guage in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the front oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., replacement of the back oil seal ( crank shaft ) in existing dea sets up to 20 kva capacity of various make and model as per manufacturer recommendations i/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd., repairing of cylinder head ( one job for each head ) with replacement of valve seat, valve guide, valves and stamp seal i/c grinding , lapping of valves i/c turning, grinding of head etc complete as reqd., repairing of up to 20 kva dea sets crank shaft i/c grinding, lapping, bushing, allignement etc complete as reqd., transportation charges up to 50 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., transportation charges more than 51 to 100 km for alternator of various capacity up to 55 kva from site to the nearest workshop & back after repairing i/c dismentling, loading, unloading, transportation, safe handling & i/c reinstallation etc. and testing on existing load for at least one hour after commissioning of the alternator etc. complete as reqd., rewinding of main stator winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity up to 20 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main stator winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of main rotor winding of alternator capacity more than 20 kva & upto 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter stator winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., rewinding of exciter rotor winding of alternator capacity up to 55 kva of existing faulty alternator of various makes with suitable size copper enamelled wire including providing insulation of appropriate class, varnishing, assembling i/c testing etc complete as required., replacement / repairing of avr make national or s.s. for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of power diode for rotating rectifier assembly for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., replacement / repairing of bearing suitable for above 20 kva alternator for existing faulty alteranator upto 55 kva capacity i/c dismentling the faulty item, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd., providing of 2 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), providing of 4 core 16 sqmm pvc insulated and pvc sheathed aluminium conductor armoured cable of 1.1 kv grade confirming to relevent is-specification complete as reqd. ( note - cable shall be provided at site / handed over to ssa authority as per direction of engg. in charge ), laying and fixing of one no upto 35 sq. mm (clamped with 1mm thick saddle) pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required., laying of one no upto 35 sq. mm pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required., supplying and making end termination with brass compression gland and aluminium lugs for 2 x 10 sq. mm (19 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq. mm ( 28 mm) for pvc insulated and pvc sheathed/xlpe aluminium conductor cable of 1.1 kv grade as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required., supply installation testing and commissioning of 32 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps 2 pole on load side handle operated change over switch in steel enclosure capable of working 240 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., supply installation testing and commissioning of 63 amps four pole on load side handle operated change over switch in steel enclosure capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., providing and fixing 63 a tpn disconnector fuse switch unit in sheet steel enclosure a/w hrc fuses capable of working 415/500 v i/c drilling hole on the board, making connection, earthing the body etc. as reqd., repairing of fuel injection pump(fip), nozzle & injectors i/c dismantling, transportation of pump, cleaning, repairing, testing and refitting the same on the existing e/a set i/c replacement of faulty components etc. complete as reqd.., supply installation testing and commissioning of 12 volt 88ah lead acid maintenance free battery for testing of above dg set, including installation at last site after repairing of all dg sets.


Tender Value : 0
Due Date : Jun 29, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 15602567
Location : lucknow , uttar pradesh
Source : GEM Tenders

tender for main fire pump , diesel driven pump , jockey pump , terrace pump , control panel , starter , m s pipe , internal hydrant valve , external yard hydrant valve , butterfly valve , sfc of butterfly valve , orifice plate , pitc non return valve , stainless steel y strainer , pitc of stainless steel y strainer , hose pipe , first aid hose reel , short branch pipe , fire brigade connection , foot valve , air vessel , pressure switch , pressure gauge , control valve , hose cabinet , cutting holes , supply of cable , laying of cable , end termination , fire cable , cable tray , earthing , gi strip , gi strip , earth wire , gi pipe, pitc of fire fighting with wet riser system, sh 1 wet riser system main fire pump a supplying, installation, testing and commissioning of electric driven main fire pump conforming to is 12469 2019 suitable for automatic peration and consisting of following complete in all respects as required. b horizontal type multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft fire pump capable for delivery of 2280 lpm against atotal head of 70 mtrs approximately while running at 1450 1500 rpm mechanical seal as required bsnl approved make. c suitable hp squirrel cage induction motor tefc synchronous speed 1500 rpm suitable for operation on 415 volts 3 phase 50 hz ac supply with ip 55 protection for enclosure horizontal foot mounted type with class. f insulation conforming to is 12615 2018. d m.s. fabricated common base plate coupling,coupling guard, foundation bolts etc. as required. e suitable cement concrete foundation duly plastered with anti vibration pads note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point.the pump room is situated on the underground water tank. 2280 lpm at 70 m head, diesel driven pump a supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to is 12469 2019 suitable for automatic operation and nsisting of following,complete in all respects, as required.diesel driven pump. b horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 lpm against atoatl head of 70 mtrs approxi as required.c suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.d m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.e suitable cement concrete foundation duly plastered and with anti vibration pads.note the head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. the pump room is situated on the underground water tank.2280 lpm at 70 m head, jockey pump a supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to is 12469 2019 suitable for automatic operation and consisting of following, complete in all respects as required jockey pump.b horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is 12615 2018. d m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) suitable cement concrete foundation duly plastered and with anti vibration pads.note the pump room is situated on the underground water tank. 180 lpm at 70 m head, supplying, installation, testing and commissioning of electric driven terrace pump conforming to is 12469 2019 suitable for automatic operation and consisting of following,complete in all respects, as required terrace pump b horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.c suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is-12615 2018. d m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.e suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m head, control panels fabrication supplying installation testing and commissioning of electrical control panel of cubical construction floor mounted type fabricated out of 2mm thick crca , apartmentalised with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper copper strip, having switchgears and accessories, mountings and internal wiring earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump and diesel pump set complete as per cpwd specification and atc attached for main fire pump , jockey pump, diesel pump with system controller as per as per atc attached, supply installation testing and commissioning of fully automatic dol starter for terrace pump terrace pump siutable for operation on 3 phase 415 volt ac supply i/c making inter connection testing etc as requiored at site., sh ii pipes and accessories.providing laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class -ii of is 3589 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 50 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 80 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia, providing, laying, testing and commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 150 mm dia, providing, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/class ii of is 3589 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. 200 mm dia wall thickness 6.3 mm, supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required.single headed gunmetal, supplying and fixing single headed external yard hydrant valve with 1 no. 63 mm dia instantaneous fm gunmetal/stainless steel coupling and cast iron wheel, isi marked, conforming to is 5290 type a with blank gunmetal/stainless steel cap and chain as required. single headed gunmetal, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required . 50mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .80 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .100 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .150 mm dia, supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required .200 mm dia, supplying and fixing orifice plate made out of 6 mm thick stainless steel grade 304 with orifice of required size to be fitted between flange and landing valve of external and internal e pressure at the outlet to the level of 3.5 kg/cm2 complete as required., providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 50mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 80 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 100 mm dia, providing, installation, testing and commissioning of non return valve of following sizes confirming to is 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required. 150 mm dia., providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia, providing, installation, testing and commissioning of stainless steel y strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia, supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and femalecouplings duly bound with gi wire, rivets etc conforming to is 636 type a as required. gun metal., supplying and fixing first aid hose reel with ms construction spray painted in post office red,conforming to is 884 complete with the following as required.a 20 mm nominal internal dia. water hose thermoplastic textile reinforced type 2 as per is 12585 b 20 mm nominal internal dia gun metal globe valve and nozzle. c drum and brackets for fixing the equipmets on wall. d connections from riser with 25 mm dia stop gun metal valve and m.s. pipe and socket. 30 mtrs, supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.gun metal., supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required. 2 way 100 mm dia m.s. pipe, supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia ms pipe connection conforming to is 904 as required.4 way 150 mm dia m.s. pipe., providing, installation, testing and commissioning of c.i flanged swing type foot valve isi marked of following sizes confirming to is 4038 complete with all acessories complete etc as required.200 mm dia., supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required., providing and fixing of pressure switch in m.s. pipe line including connection etc. as required., providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. as required., providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, ms pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required. 150 mm dia, supplying and fixing of hose cabinet of size 750 mm 600 mm 250 mm made of 2 mm thick ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 nos . 15 mtr. long hose pipe, 1 no branch pipe, mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required., cutting holes up to 15cm and 15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1 2 4 1 cement 2 coarse sand graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof., sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 4 core 16 sqmm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988 . 3.5 core 25 sq. mm, sh iii cabling and other misc work control wiring required .providing of following sizes stranded aluminum conductor, xlpe insulated, pvc sheathed, 650 v/1100 v grade as per is 7098 part 1 1988. 3.5 core x 70 sq. mm, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. upto 35 sq. mm clamped with 1mm thick saddle, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 35 sq. mm and upto 95 sq. mm clamped with 25 mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. above 185 sq. mm and upto 400 sq. mm clamped with 40mm and 3mm ms flat clamp, laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required. upto 35 sq. mm clamped with 1mm thick saddle., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 35 sq. mm and upto 95 sq. mm clamped with 25mm and 3mm ms flat clamp., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on cable tray as required.above 185 sq. mm and upto 400 sq. mm clamped with 40mm 3mm ms flat clamp, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.mm above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required.above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. upto 35 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 35 sq. mm and upto 95 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. above 185 sq. mm and upto 400 sq. mm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 4 core 16 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 25 sq. mm size 28mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 70 sq. mm size 38mm, supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.3.5 core 300 sq. mm size 70mm, supplying and laying of 2core 1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring and frls/hffr outer sheath complete as required., supplying and installaton following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5 percent, in convenient sections, joined with connectors, suspended from the ceiling with two numbers ms/gi suspenders including base of suitable size ms/gi angle, bolts and nuts, painting suspenders, fastener etc as required. 100 mm wide , 50 mm depth , 1.6 mm thickness, earthing with g.i. earth plate 600 mm length x 600 width and 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required., providing and fixing 25 mm wide and 5 mm thick g.i. strip on surface or in recess for connections etc. as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., providing and fixing following sizes g.i. pipes complete with g.i. fittings including trenching and refilling etc. 80 mm dia nominal bore


Tender Value : 5995340
Due Date : Jun 30, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Floor Covering Repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Floor Covering Repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Floor Covering Repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Floor Covering Repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Floor Covering Repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Floor Covering Repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Floor Covering Repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Floor Covering Repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Floor Covering Repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Floor Covering Repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Floor Covering Repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Floor Covering Repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Floor Covering Repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Floor Covering Repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Floor Covering Repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Floor Covering Repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Floor Covering Repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Floor Covering Repair is declared L1 and is generally awarded the contract