Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Fire alarm detector Tenders List

Latest Fire alarm detector Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Fire alarm detector tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Fire alarm detector tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Fire alarm detector Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Fire alarm detector tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Fire alarm detector Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Fire alarm detector Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Fire alarm detector Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Fire alarm detector tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Fire alarm detector Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Fire alarm detector sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Fire alarm detector tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Fire alarm detector tenders.

Is EMD mandatory for all Fire alarm detector tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Fire alarm detector work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Fire alarm detector tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Fire alarm detector Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15289435
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer


Agency / Dept : mumbai port trust MPT
Tender Value : 92399995
Due Date : Jun 08, 2026
T18 Ref No : 15427676
live Tender
Location : rawatbhata , rajasthan
Source : GEM Tenders
live Tender

tender for item number 1 , item number 2 , item number 3 , item number 4 , item number 5 , item number 6 , item number 7 , item number 8 , item number 9 , item number 10 , item number 11 , item number 12 , item number 13 , item number 14 , item number 15 , item number 16 , item number 17 , item number 18 , item number 19 , item number 20 , item number 21 , item number 22 , item number 23 , item number 24 , item number 25 , item number 26 , item number 27 , item number 28 , item number 29 , item number 30 , item number 31 , item number 32 , item number 33 , item number 34 , item number 35 , item number 36 , item number 37 , item number 38 , item number 39 , item number 40 , item number 41 , item number 42 , item number 43 , item number 44 , item number 45 , item number 46 , item number 47 , item number 48 , item number 49 , item number 50 , item number 51 , item number 52 , item number 53 , item number 54 , item number 55 , item number 56 , item number 57 , item number 58 , item number 59 , item number 60 , item number 61 , item number 62 , item number 63 , item number 64 , item number 65 , item number 66 , item number 67 , item number 68 , item number 69 , item number 70 , item number 71 , item number 72 , item number 73 , item number 74 , item number 75 , item number 76 , item number 77 , item number 78 , item number 79 , item number 80 , item number 81 , item number 82 , item number 83 , item number 84 , item number 85 , item number 86 , item number 87 , item number 88 , item number 89 , item number 90 , item number 91, ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov, input surge protection network (mov based) in-20ka, imax-40ka up-2.2kv, current transformer 80 a / 5 a, cl 1.0, 5 va, current transformer for ac ammeter am1, 75a/5a, cl1.0, 5va, emc filter (ac side) (mf-423-3-3d-80a-440vac, case r4) 440 v, 80 a ac, emc filter (ac side) (mf-423-3-3d-60a-440vac, case r7) 440v/60a ac, surge suppressor mov for ac input 275 v/20d (mov1-3), surge suppressor mov for ac input 510v ac (k510) (mov 4-6), control transformer for ac auxiliary supply 456 / 240vac, 500va, cooling fan with fan failure alarm contact 230v ac, 6 inch,50w, 3ph, ac power capacitor 7.5kvar, 480v, 3ph, ac power capacitor 10kvar, 480v, ac reactor for pfc1 25a, 1550 micro henry, three phase, double wound, impregnated naturally air cooled mains transformer 50.03 kva (456/300v), three phase, double wound, impregnated naturally air cooled mains transformer 38.21kva (456/40v), semi-conductor hrc fuses for the rectifier bridge 80et, 690v, semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt), rectifier fuse fail detector circuit for rectifier fuse 220v dc, rectifier fuse fail detector circuit for above fuse 24v dc, diode skkd101/16, scr1 12 425 a 12nos (425a/1000piv), d1 300a 300a/600piv, interphase transformer 1.238kva, interphase transformer 1.13kva, shunt for cpc1, cpc2 sh 100a/75mv, shunt for cpc1, cpc2 sh 600a/75mv, bleeder resistance 350 ohm 750w 2 in parallel, bleeder resistance 50 ohm 100w 4 in parallel, bleeder resistance 2k 50w 2 in series, bleeder resistance 50 ohm 50w, dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function, dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a, dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a, dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a, filter choke 118 a 650 micro h, filter choke 676 a 16.5 micro h, filter condenser fuse fail detector circuit 220v dc, filter condenser fuse fail detector circuit 24v dc, 3 phase scr full controller card for scr firing 220v dc, 3 phase scr full controller card for scr firing 24v dc, 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc, 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc, 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o, double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w, potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a, potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a, rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function, rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function, rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function, rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function, 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc, charger silicon blocker diode diode skr300_12, 300a_1200 piv, 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o, load under voltage circuit of solid state sensing type for alarm indication and pfc, load over voltage circuit of solid state sensing type for alarm indication and pfc, load over voltage circuit of solid state sensing type for pfc and trip function, dc over voltage circuit of solid state sensing type for interlock purpose actuating voltage 290v, thermostat for component temperature sensing, current sensing shunt to read standby current sh 150a_75mv, current sensing shunt to read standby current sh 800a_75mv, dc overload circuit of solid state sensing type for load on dcps-2 alarm indication and pfc 230v ac_20a, dc overload solid state sensing type card for battery charging current high alarm indication and pfc, dc overload solid state sensing type card for battery current limit function, dc overload solid-state sensing type card for load on batt alarm indication and pfc, battery over voltage circuit of solid state sensing type for batt 2.4v function set_2.35v per cell, battery over voltage circuit of solid state sensing type for batt, battery over voltage circuit of solid state sensing type for batt 2.75v function, battery under voltage sensing circuit of solid state sensing type for low battery alarm indication and pfc, 2 c_o plug in type auxiliary relay with base for low batt as contact multiplier 12v dc, 12v power supply card 230vac_12vdc, 12v power supply card 220vdc_12vdc, 12v power supply card 24vdc_12vdc, static annunciation circuit with accept_test_reset push button 12v dc, buzzer for static annunciation 200v dc, buzzer for static annunciation 12v dc, alarm_fault indicating leds for annunciation circuit 10_20ma 5 mm red, indicating led for battery polarity reversed alarm with resistor rs 100kohm_2w 10_20ma 5 mm red, mimic leds dual colour_red_green with series resister rs 100kohm_2w 10_20ma 5 mm red_green, status indicating leds with series resister rs 100kohm_2w 10_20ma _5 mm green, ac i_p terminal bus bar terminal_3nos_20x3cu, battery terminal bus bar terminal_2nos_ 40x5cu, battery terminal bus bar terminal_2nos_40 x 10 cu, capacitor for o_p o_l1 100k_630v, capacitor for o_p o_l1 10 pf_630v, capacitor for emc_1 47 n f per 1 k v


Tender Value : 0
Due Date : Jun 10, 2026