Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Electrical voltage systems Tenders List

Latest Electrical voltage systems Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Electrical voltage systems tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Electrical voltage systems tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Electrical voltage systems Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Electrical voltage systems tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Electrical voltage systems Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Electrical voltage systems Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Electrical voltage systems Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Electrical voltage systems tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Electrical voltage systems Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Electrical voltage systems sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Electrical voltage systems tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Electrical voltage systems tenders.

Is EMD mandatory for all Electrical voltage systems tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Electrical voltage systems work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Electrical voltage systems tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Electrical voltage systems Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15572042
new Tender
Location : pune , maharashtra
Source : GEM Tenders
new Tender

tender for z6 r72 pus-1sr-800 panel with elements , z6 r72 pus1sr-400 panel with elements , z6 r72 pp-28-010 body , lv1 r72 gost.17475.80 screw bm4-6gx16.46.016 , z6 r72 pus-1sr-600 time relay , lv1 r72 rm.11 diaphragm , z6 r72 gost-11738-72 screw m8.6hx40.66.05 , z6 r72 misc-gost-13463-77 washer 12-01-019 , z1 r72 miscgost-10450-78-r relay tke-54-17591 , z1 r72 misc-gao364-108tu receptacle shrg 28 p7 ash9 w2 , lv1 r72 gost.5915.70 nut m20-6h.10.38xc-016 , lv1 r72 172-12- 022 cap , lv1 r72 172.86.098sb reducing valve with filter , z1 r72 misc-efy-18- -16 transistor pnp , z1 r72 misc-cm3-362-018ty diode d 223a , z1 r72 misc-cm3- 362-012ty diode d 814b stabliser , z1 r72 misc-in-48ab diode silicon in 48a-b , lv1 r72 155.22.013 stop , x2 r72 misc-geo-364-140ty plug 2 pmg 24b 19 sh 3 e 2b , x2 r72 misc-gost-11371-78 plug pwabpb6 , x2 r72 misc-gost-3128-70 r plug 2 pmg 18b7 sh 1k2 , z1 r72 r10t-143 r8 resistor r8 , z6 r72 bk8-653-197 pipe connector bolt , lv1 r72 175.63.031 nut , x2 r72 misc -h10-481-017 fuse pm 2a , z6 r72 misc-gost-17475-72 screw m4-6gx12.36.016 , x2 r72 gost-5010-75 roh- 2 fuse u 30-5 , z6 r72 misc-gost-17475-72 screw m8- 6ex18.48.019 , x2 r72 misc-geo-364-140 ty plug 2pmg d42 b45 sh5 b2 , x2 r72 misc-geo-364-140 ty plug 2pmg d33 b32 sh5 b2 , x2 r72 misc-geo-364-140 ty plug 2pmg d36 b20 sh5 b2 , x2 r72 misc-geo-364-140 ty plug 2pmg d27 b19 sh5 b2 , z6 r72 bc6-112-083 body , z6 r72 misc-bc6-112-084 body , z6 r72 bc6-170-066 cover vehicular component , z1 r72 misc-ojo-467-107tu resistor omlt-2-180 -10 r3 , z6 r72 bc6-170-070 cover z6 r72 misc-bc2-958-028 sealing ring be dp-3012 size 16x2 , z6 r72 bc6-112-023 breather , z1 r72 misc-pqo 450-047ty relay p3c 47 magnetic relay p7c 47 , x2 r72 misc-geo-364-108-ty1 plug shpg 32 p8 esh2 , z6 r72 bc6-110-105 housing , y3 r72 misc-cwpg36p15ew3 connector , x2 r72 misc-cwp 60p 453w3 o connector , x2 r72 misc-cshd-32p-10a-sh plug w1 , lv1 r72 172.83.076sb nut , x2 r72 misc-2pmgd24b19w1e2b connector , z6 r72 bc5-890-002 valve , z6 r72 bc2- 958-028 sealing ring bc dp-3012 size 48 2 , z1 r72 misc-ozho-464-023ty capacitor 33 mfd 35v - 10 , z6 bc2-958-028 sealing ring bdp-3012 size 52x2 , z1 r72 misc-oxo-467-107ty resister 3k ohm -1 1 4w -10 , lv1 r72 172.83.306 valve , z6 r72 bc2-958-028 sealing ring bc dp-3012 size 22x2 , z6 r72 bs5-768-001 coil , z6 r72 misc-bs5-886-019 filter , lv1 r72 gost 5935.73 nut m12x1.25-6h-04-016 gost 5935-73 , z6 r72 bc5-886- 045 filter , z6 r72 bc5-886-051 filter , z6 r72 misc- bc5-889-007 float , z6 r72 misc-bc5-890-004 valve , z6 r72 misc-d-815a voltage stabilizing diode , lv1 r72 gost 17473.80 screw bm3-6gx40.46.016 , z6 r72 misc- csn.02.1101.25 bolt m 8x35 , z6 r72 misc-amt-81m-080- 01 contact system , z6 r72 misc-ety-500-65 bearing 802 , z6 r72 misc-gost-10450-78 washer 8-04-019 , z6 r72 misc-g0st-1491-72 m screw m3x8.48.016-9 , z1 r72 misc-2k3-365-059tu transistor p307v , z1 r72 misc- gao-364-108tu receptacle shrg 40 p 16 sh2 w1 , lv1 r72 172.33.011sb.4 valve, air vent , z1 r72 geo 364- 140 ty 2pm plug 2pm18etw 1e 26 , z1 r72 misc-d816a stlabilizer diode c2 cd , z1 r72 5961-000375 transistor cdil 2n 3019 , z6 r72 bc6-330-001 electric motor with drive , z6 r72 bc8-684-074 collar , z6 r72 misc-bc6-173-012 cover vehicular components , z6 r72 misc-ty-37-006-068-7 bearing 6-46124e , z1 r72 misc-wt-4602-33-73 diode , z6 r72 bc6-328-003 screw , z6 r72 bc8-914-015 screw , z6 r72 bc8-920-012 bolt , z6 r72 oyu3-602-069 micro switch mp-12 , z6 r72 bc8- 920-034 bolt , z6 r72 bc8-920-044 bolt , z6 r72 bc8- 920-046 bolt , z6 r72 misc-bc6-170-079 cover vehicular components , z6 r72 misc-pb8-930-116 coupling nut , lv1 r72 gost 1491.80 screw bm5- 6gx22.32.036 , z6 r72 misc-gost-1491-72 screw m4.6ex14.48.016.9 , n1 r72 2a46-21-76 handle 2a46-21- 76 , z6 r72 misc-amt-81-019-2 adjusting washer , z6 r72 misc-gost-17475-80-s screw bm5x14-36-016 , z6 r72 bc8-943-002 spring washer , z6 r72 misc-gost- 18678-73 sealing cup 1-8-10-016 , lv1 r72 5305720164699 screw bm5-6gx55-46-016 gost 17473- 80 , z6 r72 x1-10548 screw , z6 r72 misc-gost-18678- 73 plug shpg 36 p4 ash 13 , z6 r72 misc-bd2-032-005 amplifier , lv1 r72 gost 1144.80 screw , z1 r72 misc- 4682-730-301-64 relay armature unseald k9 , z6 r72 misc-gost-22036-76 stud m10x6ex30.48.019 , z1 r72 misc-450-033ty relay p3c 48 a-b , z1 r72 misc-bn-73 3375-15-0 diode byp 680-300r , z6 r72 bc8-687-017 collar , z1 r72 misc-493-365-013ty transistor 2t 6085 or 2n 2219 2t6085 , z6 r72 misc-gost-17475-80 screw bm4-6gx16-36-016 , lv1 r72 432.66.136 coupling , z6 r72 misc-amt-81-013 spring , lv1 r72 gost.5496.78 pipe 1-4m 24x2x80mm , z6 r72 miscamt-81-008 cover , lv1 r72 gost 5496.78 pipe 1-4c 6x2 l 30mm , z1 r72 misc-uzh3-362-018 transistor kd 617 , lv1 r72 5305720162525 screw bm5-6gx16-46-016 gost 1491-80 , lv1 r72 gost 5496-78 pipe 1-4c 12x2 l 30mm , lv1 r72, z6 r72 pus-1sr-800 panel with elements, z6 r72 pus-1sr-400 panel with elements, z6 r72 pp-28-010 body, lv1 r72 gost.17475.80 screw bm4-6gx16.46.016, z6 r72 pus-1sr-600 time relay, lv1 r72 rm.11 diaphragm, z6 r72 gost-11738-72 screw m8.6hx40.66.05, z6 r72 misc-gost-13463-77 washer 12-01-019, z1 r72 misc-gost-10450-78-r relay tke-54-17591, z1 r72 misc-gao-364-108tu receptacle shrg 28 p7 ash9 w2, lv1 r72 gost.5915.70 nut m20-6h.10.38xc-016, lv1 r72 172-12-022 cap, lv1 r72 172.86.098sb reducing valve with filter, z1 r72 misc-efy-18- -16 transistor pnp, z1 r72 misc-cm3-362-018ty diode d 223a, z1 r72 misc-cm3-362-012ty diode d 814b stabliser, z1 r72 misc-in-48a-b diode silicon in 48a-b, lv1 r72 155.22.013 stop, x2 r72 misc-geo-364-140ty plug 2 pmg 24b 19 sh 3 e 2b, x2 r72 misc-gost-11371-78 plug pwabpb6, x2 r72 misc-gost-3128-70 r plug 2 pmg 18b7 sh 1k2, z1 r72 r10t-143 r8 resistor r8, z6 r72 bk8-653-197 pipe connector bolt, lv1 r72 175.63.031 nut, x2 r72 misc -h10-481-017 fuse pm 2a, z6 r72 misc-gost-17475-72 screw m4-6gx12.36.016, x2 r72 gost-5010-75 roh- 2 fuse u 30-5, z6 r72 misc-gost-17475-72 screw m8-6ex18.48.019, x2 r72 misc-geo-364-140 ty plug 2pmg d42 b45 sh5 b2, x2 r72 misc-geo-364-140 ty plug 2pmg d33 b32 sh5 b2, x2 r72 misc-geo-364-140 ty plug 2pmg d36 b20 sh5 b2, x2 r72 misc-geo-364-140 ty plug 2pmg d27 b19 sh5 b2, z6 r72 bc6-112-083 body, z6 r72 misc-bc6-112-084 body, z6 r72 bc6-170-066 cover vehicular component, z1 r72 misc-ojo-467-107tu resistor omlt-2-180 -10 r3, z6 r72 bc6-170-070 cover, z6 r72 misc-bc2-958-028 sealing ring be dp-3012 size 16x2, z6 r72 bc6-112-023 breather, z1 r72 misc-pqo-450-047ty relay p3c 47 magnetic relay p7c 47, x2 r72 misc-geo-364-108-ty1 plug shpg 32 p8 esh2, z6 r72 bc6-110-105 housing, y3 r72 misc-cwpg36p15ew3 connector, x2 r72 misc-cwp 60p 453w3 o connector, x2 r72 misc-cshd-32p-10a-sh plug w1, lv1 r72 172.83.076sb nut, x2 r72 misc-2pmgd24b19w1e2b connector, z6 r72 bc5-890-002 valve, z6 r72 bc2-958-028 sealing ring bc dp 3012 size 48 2, z1 r72 misc-ozho-464-023ty capacitor 33 mfd 35v - 10, z6 bc2-958-028 sealing ring bdp-3012 size 52x2, z1 r72 misc-oxo-467-107ty resister 3k ohm -1 1 4w -10, lv1 r72 172.83.306 valve, z6 r72 bc2-958-028 sealing ring bc dp-3012 size 22x2, z6 r72 bs5-768-001 coil, z6 r72 misc-bs5-886-019 filter, lv1 r72 gost 5935.73 nut m12x1.25-6h-04-016 gost 5935-73, z6 r72 bc5-886-045 filter, z6 r72 bc5-886-051 filter, z6 r72 misc-bc5-889-007 float, z6 r72 misc-bc5-890-004 valve, z6 r72 misc-d-815a voltage stabilizing diode, lv1 r72 gost 17473.80 screw bm3-6gx40.46.016, z6 r72 misc-csn.02.1101.25 bolt m 8x35, z6 r72 misc-amt-81m-080-01 contact system, z6 r72 misc-ety-500-65 bearing 802, z6 r72 misc-gost-10450-78 washer 8-04-019, z6 r72 misc-g0st-1491-72 m screw m3x8.48.016-9, z1 r72 misc-2k3-365-059tu transistor p307v, z1 r72 misc-gao-364-108tu receptacle shrg 40 p 16 sh2 w1, lv1 r72 172.33.011sb.4 valve, air vent, z1 r72 geo 364-140 ty 2pm plug 2pm18etw 1e 26, z1 r72 misc-d816a stlabilizer diode c2 cd, z1 r72 5961-000375 transistor cdil 2n 3019, z6 r72 bc6-330-001 electric motor with drive, z6 r72 bc8-684-074 collar, z6 r72 misc-bc6-173-012 cover vehicular components, z6 r72 misc-ty-37-006-068-7 bearing 6-46124e, z1 r72 misc-wt-4602-33-73 diode, z6 r72 bc6-328-003 screw, z6 r72 bc8-914-015 screw, z6 r72 bc8-920-012 bolt, z6 r72 oyu3-602-069 micro switch mp-12, z6 r72 bc8-920-034 bolt, z6 r72 bc8-920-044 bolt, z6 r72 bc8-920-046 bolt, z6 r72 misc-bc6-170-079 cover vehicular components, z6 r72 misc-pb8-930-116 coupling nut, lv1 r72 gost 1491.80 screw bm5-6gx22.32.036, z6 r72 misc-gost-1491-72 screw m4.6ex14.48.016.9, n1 r72 2a46-21-76 handle 2a46-21-76, z6 r72 misc-amt-81-019-2 adjusting washer, z6 r72 misc-gost-17475-80-s screw bm5x14-36-016, z6 r72 bc8-943-002 spring washer, z6 r72 misc-gost-18678-73 sealing cup 1-8-10-016, lv1 r72 5305720164699 screw bm5-6gx55-46-016 gost 17473-80, z6 r72 x1-10548 screw, z6 r72 misc-gost-18678-73 plug shpg 36 p4 ash 13, z6 r72 misc-bd2-032-005 amplifier, lv1 r72 gost 1144.80 screw, z1 r72 misc-4682-730-301-64 relay armature unseald k9, z6 r72 misc-gost-22036-76 stud m10x6ex30.48.019, z1 r72 misc-450-033ty relay p3c 48 a-b, z1 r72 misc-bn-73 3375-15-0 diode byp 680-300r, z6 r72 bc8-687-017 collar, z1 r72 misc-493-365-013ty transistor 2t 6085 or 2n 2219 2t6085, z6 r72 misc-gost-17475-80 screw bm4-6gx16-36-016, lv1 r72 432.66.136 coupling, z6 r72 misc-amt-81-013 spring, lv1 r72 gost.5496.78 pipe 1-4m 24x2x80mm, z6 r72 miscamt-81-008 cover, lv1 r72 gost 5496.78 pipe 1-4c 6x2 l 30mm, z1 r72 misc-uzh3-362-018 transistor kd 617, lv1 r72 5305720162525 screw bm5-6gx16-46-016 gost 1491-80, lv1 r72 gost 5496-78 pipe 1-4c 12x2 l 30mm, lv1 r72 172.2m.31.008 clamp, z1 r72 misc-uzh3-362-035tu diode silicon 2d 202 d, z6 r72 misc-gost-1491-80 b screw bm1.6gx16.36.016, z6 r72 misc-gost-1491-72 m screw m5.6hx20.48.05, z6 r72 misc-gost-1491-72 s sealing ring bedp-3012 size 18x2, z6 r72 misc-gost-1491-72 s sealing ring bedp-3012 size 20x2, lv1 r72 tu 005-6016-87 hose 40u25-13 bore dia 25 mm wall thk 5, z6 r72 misc-gost-17475-80 screw bm4.6gx12-36-016, z6 r72 5dm-667-020 converter rotor, n1 r72 2a46-21-77 aroh-521 nut elevation mech, z6 r72 misc-gost-1491-72 sealing ring bedp-3012 size 83x2, z6 r72 misc-gost-1491-72-ca cap, z1 r72 1-oq3-365-035ty transister 2t 208m or 2n 2904a, z6 r72 misc-gost-1491-80-sc screw bm2-6gx10-48a-016, lv1 r72 tu 005-6016-87 40u38 hose 40u 38-13 bor dia 38mm wthk 6.2m, z1 r72 misc-type-tky3-101 contactor, z6 r72 bk8-220-744 bushing, z1 r72 misc-tp3-362-021ty silicon diode d-237a, z1 r72 misc-tadiran2020-090 cg-409 sh 2.75m shield rf cable, z6 r72 misc-bk8-210-817 plug assembly sealing, z6 r72 bk8-684-367 sealing ring, z6 r72 bk8-920-077 bolt, lv1 r72 5310237277 washer 10 ot 65g 016 gost 6402-70, z6 r72 bk8-920-419 bolt, z1 r72 misc-172-73-038sb cable no 6p, z6 r72 misc-dbn-038 ring, z6 r72 dpk1.1-001-73 sp-10 holder, z6 r72 misc-amt-11-008 spring, z1 r72 w 613.365.007 ty transistor 2t 203a, lv1 r72 172.83.100sb usce valve, n1 r72 2540-009245 body cell lifting mech 172-28-035-1a, n1 r72 5365-185048 bushing for guard 2a26-10-169, n1 r72 6h8-810-274 aroh- 8 plate mtg of gun 2a46 elevng mech, z6 r72 misc-gost-1491-80 b screw m3-6gx8-36-016-9, lv1 r72 172.31.081sb.1 relief valve, vaccum and pressure, z6 r72 misc-gost-1491-80 b screw bm4-6gx10.48.016, z1 r72 misc-t-72-tu-872-66 relay tke 52, lv1 r72 gost 17475.80 screw, bm4-6gx10.46, lv1 r72 gost 17475.80 screw bm4-6gx50.46.016 gost 17475-80, lv1 r72 gost 17475.80 screw bm4-6gx8.46.016 gost 17475-80, z6 r72 bk8-056-560 cover, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 8x2, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 95x4, z6 r72 gost-13943-68 ring b-18, z6 r72 misc-gost-13943-68 ring 510, z6 r72 bk7-016-116 valve, z1 r72 xito-450-000ty relay pzh 34, z6 r72 misc-gost-13943-68 sealing ring upn-3012 size 135x3, z6 r72 bk8-056-561 cover, z6 r72 misc-gost-1491-72 screw m3-6gx8.36.016, z6 r72 gost-1491-72 screw m4-8-32-11, z6 r72 bk6-695-390 board, z6 r72 gost-1491-72 screw m3-6gx8.48.016 m3x8.48.016, z6 r72 bk6-673-500 terminal board, n1 r72 5305092778 oh-882 screw bm10-6gx22.46.016 gost-1491-80, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 30x20, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 26x2, z6 r72 bk6-659-009 coil, z6 r72 misc-gost-13943-68 seaing ring be pii-3012 85x4, n1 r72 5305-090652 screw b1.m4-6gx66.c.06 gost 17473-80, n1 r72 5315-048726 cotter pin 2x16.06 gost 397-79, lv1 r72 gost 17473.80 screw, bm8x1.6gx18.46.016, x2 r72 ty6309-73 contactor tkd-511 kod, z6 r72 gost-2524-70 sealing ring edp-3012 size 25x2, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 14x2, z6 r72 gost-2524-70 sealing ring edp-3012 size 30x3, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 15x2, z6 r72 gost-2524-70 sealing ring edp-3012 size 42x3, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 16x2, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 17x2, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 22x2, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 25x3, n1 r72 a51066-108 screw m6x18 cradle, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 55x3, z6 r72 bk8-247-144 spring ring, z6 r72 misc-gost-13943-68 sealing ring be pii-3012 48x3, x2 r72 tu7100-361-002 contactor tkd-111 dod, z6 r72 bk8-241-902 ring, c2 r72 172-94-014sb aroh 1 handle, z6 r72 bk8-241-851 ring, z6 r72 bk8-684-368 sealing ring, z6 r72 bk8-684-995 sealing ring, z6 r72 bk8-685-599 sealing ring, c2 r72 172-94-009 cb casing assy drg no cqa sa sk-1388


Agency / Dept : indian army
Tender Value : 0
Due Date : Jun 19, 2026
T18 Ref No : 15412289
live Tender
Location : dehradun , uttarakhand
Source : GEM Tenders
live Tender

tender for title1 , title2 , title3 , title4 , title5 , title6, supply installation testing and commissioning of self regulating heating tape cable, providing self regulating heat tape resistance heating cable suitable for freeze protection of pipelines and utilities having rated output of thirtyfive w per meter at two hundred twenty v ac supply the heating cable shall automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable shall be suitable for continuous operation in outdoor conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems, providing mtwenty threepin connector suitable for making secure electrical joints between self-regulating heat cable terminals designed for reliable power and signal continuity the connector shall be rated for operation at two hundred twenty v ac supply and compatible with heating cables of specified capacity it shall ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be constructed from high quality weather resistant materials suitable for continuous outdoor operation under varying environmental conditions it shall provide ease of installation with a compact and durable design for use at pipeline joints terminations and interconnections the mtwenty connector shall be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress, providing temperature differential controller with auto and manual operation housed in a robust ip sixty five rated enclosure suitable for controlling heat tracing systems to prevent freezing of pipelines and utilities the controller shall be designed to automatically switch the heat tape on oblique off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller shall include in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions, providing pt hundred temperature sensors with ten metres cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors shall be of platinum resistance type pt hundred ensuring high precision stability and repeatability over a wide temperature range.each sensor shall be supplied with a ten metre long high quality insulated cable suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable, flexible, and suitable for installation in outdoor and industrial environments, providing heat tape laying and installation services for self-regulating heat tracing systems including proper routing and fixing of heating cables along pipelines joints valves and exposed sections near utility areas the installation shall be carried out to ensure uniform heat distribution and effective freeze protection as per recommended practices, providing three core one point five sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications and rated for voltage grade up to eleven hundred volts the cable shall conform to the requirements of is six nine four and two thousand ten the conductors shall be made of high conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it shall be suitable for continuous operation in indoor and outdoor environments offering reliable performance electrical safety and long service life


Tender Value : 0
Due Date : Jun 08, 2026
T18 Ref No : 15289435
live Tender
Location : mumbai , maharashtra
Source : GEM Tenders
live Tender

tender for optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation, shifting of secondary substation at workshop to frere basin compound, supply of prefabricated containerized substation e-house having ip54 enclosure with 2 hr fire rated thermal insulation sandwich panel suitable for accommodating ht lt switchgear panel transformers battery bank battery charger and apfc panels as per technical specification, installation of the prefabricated containerized substation e-house at site including all necessary activities for proper placement and fixing as per oem drawings and instructions of engineer in charge, supply of 6.6kv eco-friendly indoor type green gis vcb switchgear panel with maximum system voltage 12kv 500mva rupturing capacity comprising 2 incomer 1 buscoupler 2 outgoing feeders 2 transformer feeders and 2 set bus pt as per technical specification, installation testing and commissioning of the 6.6kv ht gis vcb switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 24v dc smf-vrla battery bank of suitable load rating for ht and lt switchgear panels with minimum 1 hour backup including battery stand inter-battery wiring terminal connectors accessories and bhms as per technical specification, installation testing and commissioning of 24v dc smf-vrla battery bank inside the e-house as per technical specification and in the presence of mbpa representative, supply of float and float-cum boost charger suitable for battery bank including incoming and outgoing cables wires connection in ht switchgear and control panels with full wave rectification for 440v 3 phase 4 wire 50hz ac input supply as per technical specification, installation testing and commissioning of float and float cum boost charger inside the e-house as per technical specification and in the presence of mbpa representative, supply of iec 61439 compliant oem lt panel with tpn 2000a copper busbar 50ka 1 sec stc comprising 2 incomer acb 1 buscoupler acb 10 outgoing acb 5 mccb 400a 2 mccb 250a 2 mccb for apfc and 5 mcb outgoings as per technical specification, installation testing and commissioning of lt switchgear panel inside the e-house as per technical specification and in the presence of mbpa representative, supply of 1000 kva 6.6kv to 0.433kv dyn-11 copper wound an cooling cast resin dry type indoor transformer ip00 with off load tap links wti scanner class f insulation ht and lt cable boxes and standard accessories as per ecbc 2021 2 sets, installation testing and commissioning of 1000kva dry type transformer at site inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of wall mounted smart local monitoring hmi box with windows 10 iot intel core i5 processor 8gb ram 64gb memory 15.6 inch touch screen iec 61850 client master application software for complete substation monitoring as per technical specification, installation testing and commissioning of smart local monitoring hmi system including integration with protection relays via iec 61850 ed 2 lan as per technical specification and in the presence of mbpa representative, supply of cubicle type free standing floor mounted apfc panels of 200 kvar capacity conforming to iec 61439 with mccb incomer capacitor banks detuned reactors apfc relay and all accessories as per technical specification 2 sets, installation testing and commissioning of apfc panels inside the e-house as per technical specification and in the presence of mbpa representative 2 numbers, supply of fire detection and alarm system comprising fire alarm control panel multi-area detection module multi sensor heat and smoke detectors break glass manual call points indoor and outdoor alarm hooters with ac shutdown interlock as per technical specification, installation testing and commissioning of fire detection and alarm system as per technical specification and in the presence of mbpa representative, supply of fire extinguishers as per is 3034-1993 of suitable capacity and type for the e-house substation application complete with all accessories and mountings, installation of fire extinguishers at designated locations inside the e-house as per directions of engineer in charge, supply of minimum 2 nos 2 ton copper coil inverter split air conditioners of heavy duty industrial type along with ac controller for e-house control room as per technical specification similar to o general hitachi samsung or equivalent, installation testing and commissioning of split air conditioners and ac controller inside the e-house as per technical specification and in the presence of mbpa representative, supply of suitable type touch proof termination kits as required for ht and lt power and control cables to and within the container equipment as per technical specification, installation testing and commissioning of ht and lt touch proof termination kits inside the e-house as per technical specification and in the presence of mbpa representative, supply of 600va ups system along with smf-vrla battery conforming to jisc-8702 pt 1 2 and 3 with single phase 230v ac 50hz output for e-house emergency illumination complete with all accessories, installation testing and commissioning of ups system with battery inside the e-house as per technical specification and in the presence of mbpa representative, supply and making of chemical earthing pit using chemical earth electrode with minimum 25 kg chemical powder cement concrete chamber 500x500x200mm ci rcc cover earthing rod 17.2mm dia 3 mtr long copper bonded 250 microns as per is 3043-2018 and iec 62561 16 numbers, supply and laying of galvanized ms earthing flat 50mm x 6mm for ht lt apfc battery charger and transformer body earthing of substation equipment as per technical specification, supply and laying of copper earthing flat 50mm x 6mm for transformer neutral earthing of the substation as per technical specification, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to tank bunder substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to pandv dock substation, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to central substation css, supply and delivery of xlpe insulated pvc sheathed armoured screened cable 3c x 240 sqmm 6.6kv ue 11kv e grade aluminium conductor as per is 7098 part 2 for 6.6kv feeder from workshop substation to ro-ro pax terminal substation, tracing out existing buried 6.6kv ht cable laid feeder identification of existing feeder cable puncture and cutting in presence of mbpa representative contractor to arrange all necessary testing kits required for the same, supply of straight through joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e 6.6kv ue grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect, making of ht cable 6.6kv ue 11kv e grade straight through jointing work for cable 3c x 240 sqmm xlpe to xlpe in the presence of mbpa representative, carrying out necessary high potential test before and after making joints using calibrated testing equipment with complete test reports in the presence of mbpa representative, carrying out necessary phase sequence test using calibrated testing equipment with complete test reports and commissioning the cable in all respect in the presence of mbpa representative, supply of straight through transition joint for ht cable 3c x 240 sqmm xlpe insulated armoured aluminium conductor 11kv e grade using heat shrinkable raychem make jointing kit with ferrules tape etc complete in all respect optional, making of ht cable 6.6kv ue 11kv e grade straight through transition jointing work for cable 3c x 240 sqmm pilc to xlpe in the presence of mbpa representative optional, excavating suitable trench for ht cable in any type of soft soil or asphalt including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 300 mtr l, excavating suitable trench for ht cable in concrete or stone road including cleaning cable trenches tentative size 1.0 mtr w x 1.2 mtr d x 85 mtr l optional, laying of incoming and outgoing 3c x 240 sqmm xlpe aluminium armoured cable in excavated cable trench at depth 1200mm including cleaning dressing providing screened sand and rcc tiles engraved mbpa 6600 volts as per drawing, laying of ht cable in rcc pipe hdpe pipe existing duct or cc trench including all necessary activities as per specification, supply of rcc pipe 200mm dia np2 class of standard length with collars including cement concreting closing ends of pipes after passing cable across road culverts drains etc, laying of rcc pipe 200mm dia np2 class and fixing of collars at site including all necessary activities as per specification, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6a, supply and delivery of 3.5c x 400 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 11, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 1a, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 3, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 4, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 5, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6b, supply and delivery of 3.5c x 300 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable heavy duty conforming to is 1554 7098 part-i for outgoing to feeder pillar 6c, excavating suitable trench for lt cable in asphalt soil or paver block footpath with curb stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 700 mtr l, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 300 or 400 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply and delivery of 3.5c x 70 sqmm aluminium conductor xlpe insulated pvc sheathed 1100 volts grade armoured cable for outgoing to old cme building sbi from fp no 4 nirman bhavan, excavating suitable trench for lt cable in asphalt soil or paver block footpath with cup stone including cleaning cable trenches tentative size 0.8 mtr w x 0.9 mtr d x 150 mtr l, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in excavated cable trench including dressing providing screened sand and red bricks as per specification, laying of incoming and outgoing 3.5c x 70 sqmm lt xlpe armoured cables in rcc pipe hdpe pipe existing duct cc trench or saddling on wall as per specification, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 70 sqmm xlpe pvc cable 1100 volts grade 2 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 300 sqmm xlpe pvc cable 1100 volts grade 6 ends, supply of material for both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, installation of both cable end termination and connection with double compression brass glands and aluminium lugs for 3.5c x 400 sqmm xlpe pvc cable 1100 volts grade 2 ends, suitable quantity dimensions and grade of concrete for e-house foundation columns including soil excavation as per oem design drawings and structural design approved by bmc registered structural engineer, supply and installation of e-house shed including foundation columns i-beams angles and covering sheets as per design drawings approved by bmc registered structural engineer, providing and laying approved quality rubble packing 250mm thick hand set including filling interstices with stone chips grit stone dust watering and consolidation as specified and as directed, providing and laying 40mm to 90mm size stone metal of approved quality to required thickness in layers not exceeding 120mm consolidated with roller including filling interstices with grit stone dust sand as directed, providing and laying water bound macadam wbm layer 100mm consolidated thickness with 40 to 63mm metal consolidated with roller including watering blending with sand stone dust grit brick powder as specified, providing and laying m10 grade ready mix cement concrete from approved rmc plant in levelling course of required thickness including transit mixer form work plate vibrator curing etc as specified, providing and laying m40 grade ready mix cement concrete from approved rmc plant in road pavement bays including form work power driven screed plate and needle vibrators brooming vatas bitumen curing as specified, providing and laying approved coloured cement concrete interlocking paver blocks 100mm thick with sand bedding minimum 50mm and filling joints with fine sand as directed, providing and laying hot pre-mixed asphaltic macadam bitumen grade 60 70 with anti-stripping agent 0.5 percent by weight in regulating course and rolling with 8 to 10 tonne road roller as specified payment by weight, providing and laying hot pre-mixed asphaltic concrete wearing course bitumen grade 60 70 with anti-stripping agent 0.50 percent by weight of required thickness and rolling with 8 to 10 tonne road roller as specified payment by weight, transporting surplus excavated material stones debris kutchra from mbpa estate including loading and taking away materials anywhere outside mbpa estate as directed, dismantling of existing ht lt panel transformers apfc panel battery charger and bank cables and cable terminations of existing workshop substation and shifting removed electrical equipment to mbpa store as per instructions of engineer


Agency / Dept : mumbai port trust MPT
Tender Value : 92399995
Due Date : Jun 08, 2026
T18 Ref No : 15359506
live Tender
Location : bangalore , karnataka
live Tender

tender for supply of cnc led machine lights., supply of cnc led machine lights heavy-duty type for cnc machine area illumination, specifi cally designed for reliable operation in harsh industrial environments involving continuous exposure to cool ant, oil mist, metal chips, dust, humidity, and high vibration, ensuring consistent illumination, durability, an d long service life. the make & model shall be similar to model no: cr-gmll-24-d-30w of craftech, phoenix , rittal or equivalent. construction: 1.enclosure material: borosilicate glass (minimum 4.2 mm thick). 2.ip r ating: minimum ip67 (ip68 preferred) as per is/iec 60529 for the model or design. electrical: 1.rated power: 30w (+/-10%). 2.input voltage: direct 24 v dc & suitable to operate through external smps adapter/driver 3.polarity protection: reverse polarity safe. 4. cable length: minimum 2 meter oil resistant flexible cable . o ptical: 1.led type: lm-80 approved, high-quality industrial leds (e.g., osram / equivalent). 2.colour tempe rature: 6500 k +/- 500 k. 3.cri: ≥ 80. 4.luminaire efficacy: ≥ 110 lm/w (system efficacy, not led chip only ). 5.glare-free . 6.operating temperature: -20 degree c to +65 degree c. document & test report: 1.ip67/i p68 test certificate- shall be furnished along with offer . 2.technical datasheet shall be furnished along with offer. 3.manufacturer's routine test certificate covering optical & electrical shall be furnished along with th e material. authorization: oem or oem authorized dealers only shall quote & shall submit authorized dealer ship certificate in case of dealer from oem. - warranty period: 12 months after the date of delivery pl code : 421904360018


Agency / Dept : rail wheel factory RWF
Tender Value : 0
Due Date : Jun 05, 2026
T18 Ref No : 15348267
live Tender
Location : gandevi , gujarat
Source : GEM Tenders
live Tender

tender for bi facial solar panel 550 watt , topcon solar panel 610 watt , cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter , cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump , cut section of shell and tube heat exchanger acrylic material , cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve , gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410 , wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity , safety belt, industrial type full body protection double rope double hook,100 kg human weight , embroidery machine , brake test arrangement with two spring balance 0 to 25 kg rating , automatic motor coil winding machine with step arbor , three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz , synchronous motor, with accessories , vfd ac drive ac motor drive with vvvf control 3 phase , single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz , stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c , bldc motor fan with controller 40 watt , servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp , electrical test bench integrated with 0 to270v ac variac 25a, ppp boq1, bi facial solar panel 550 watt,efficiency 21.3 percentage,dimension 2285mm x 1134mm x 35 mm,anodized aluminumsilver frame,connector mc4 ev02,maximum system voltage 1500v dc, topcon solar panel 610 watt,efficiency 22 point 6 percent to 22 point 9 percent,n type topcon,dimension 2382x1134x30 mm,2 mm dual glass,maximum system voltage 1500v dc, cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter, cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump, cut section of shell and tube heat exchanger acrylic material, cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve, gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410, wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity, safety belt, industrial type full body protection double rope double hook,100 kg human weight, embroidery machine highlighted upper and lower tread sensors,auto adjustable tread tension,automaticneedle treader embroidery designs 227,lcd display included usb cable,embroidery erea 300 x 200 mm,maximum speed 1050 stitch per mi, brake test arrangement with two spring balance 0 to 25 kg rating with flat belt with 3 pullies having inner diameter 17 mm,23mm, 29mm and width of 2 inch, automatic motor coil winding machine with step arbor, three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz, synchronous motor, with accessories like starter, excitation arrangements,3 phase, 3hp, 440 v, 50hz, 4 pole ac voltmeter, dc voltmeter , ac ameter , dc ameter , watt meter panel with desk and drawer lock key panel total height 170 cm , width 75 cm, horizontal desk size 40 cm,drawer size 33cm x 12 cm 2 drawers,component fitting area at top 120 cm x 60 cm, vfd ac drive ac motor drive with vvvf control 3 phase, 7 point 5 hp panel with desk & drawer lock key panel total height 170 cm,width 75 cm, horizontal desk size 40 cm,drawer size 33cm x 12 cm 2 drawers , component fitting area at top 120 cm x 60 cm, single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz, stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c, bldc motor fan with controller 40 watt, servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp, electrical test bench integrated with 0 to270v ac variac 25a 01 no, dc variac 0 to 270v dc 25a 01 no, dc ameter 0 to 25a 03 nos , dc voltmeter 0 to 750 volt 03 nos, ac ammeter 0 to 25 a 03 nos, ac voltmeter 0 to 750v03 nos,1 phase power factor meter01 no ,3 phase power factor meter01 no, frequency meter 45 to 55 hz 01 no, watt meter 0 to 3000w02 nos,1 phase energy meter01 no, 3 phase energy meter01 no all equipments with seperate contact terminals and all meters are digital


Tender Value : 0
Due Date : May 28, 2026
T18 Ref No : 15458751
live Tender
Location : leh , ladakh
Source : GEM Tenders
live Tender

tender for product 1 , product 2 , product 3 , product 4 , product 5, providing and fixing self regulating heat tape cable insulation and accessories in ppr pipe at bops, providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems, providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress, providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions, providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area, providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life


Tender Value : 0
Due Date : Jun 11, 2026