Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Airport data Tenders List

Latest Airport data Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Airport data tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Airport data tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Airport data Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Airport data tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Airport data Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Airport data Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Airport data Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Airport data tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Airport data Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Airport data sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Airport data tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Airport data tenders.

Is EMD mandatory for all Airport data tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Airport data work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Airport data tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Airport data Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15200982
Location : ayodhya , uttar pradesh
Source : GEM Tenders

tender for boq item no. 1 , boq item no. 2 , boq item no. 3 , boq item no. 4 , boq item no. 5 , boq item no. 6 , boq item no. 7 , boq item no. 8 , boq item no. 9 , boq item no. 10 , boq item no. 11 , boq item no. 12 , boq item no. 13 , boq item no. 14 , boq item no. 15 , boq item no. 16 , boq item no. 17 , boq item no. 18 , boq item no. 19 , boq item no. 20 , boq item no. 21 , boq item no. 22 , boq item no. 23, operation of bhs including supply of spares and decorative lighting at mvi airport ayodhya, operation of baggage handling system ( both arrival and departure ) by engaging following minimum man power. \na) electrician cum operator/ technician - skilled - 04 nos ( all days including weekly offs & holidays).\nb) skilled - 01 no. for data entry & other miscellaneous work (in general shift for six days in a week )\nnote- contractor has to provide reliever on weekly offs / holidays of above required staffs except for sl. no. b), supply of red outer lens for rwy end light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of green outer lens for rwy threshold light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of yellow filter for runway edge light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of 200w, 6.6/6.6a halogen lamp pk30d(64382 hlx-c) make - osram or equivalent suitable for existing agl/ cat-i fittings complete as required ., supply of isolating transformer of 200 watts, 6.6a/6.6a, 5kv, 50 hz suitable for existing agl/cat-i light fixtures complete as required., supply of wind socks (cloth) for wdi(white/red) suitable for existing sgs make wind sock., supply of 360 degree outer clear lens for runway edge light fitting suitable for existing light fixture of vardhman make., supply of clear spreader lens for approach light fitting suitable for existing light fixture of vardhman make., supply of clear lens for papi suitable for existing papi system of vardhman make., supply of 2cx 4 sqmm. annealed tinned copper conductor pvc insulated pvc sheathed unarmoured flexible afl secondary lead up to voltage garde 1.1 kv conforming to relevant is up to date ammendment complete as required., supply of minimum 9 w led type aviation obstruction light in red colour having die-cast aluminum housing with red polycarbonate dome for better illumination, integral driver, ingress protection - ip65 (make- bajaj or equivalent as approved by eic), supply of 30 w movable led flood light (yellow colour) (make - philips , type - bvp102 30 or equivalent) complete as required at site., supply of 150 a, 1000v, 50 sq. mm terminal block suitable for mounting on din rail suitable for existing panel complete as required at site., supply of led driver of 80w, 25 v suitable for existing airfield signage board (make-electrosystem) installed in operational area complete as required at site., supply of 15 w led suitable for existing taxiway light fitting of vardhman make complete as required at site., supply of electronic driver suitable for existing 15 w led taxiway light fitting of vardhman make complete as required at site., supply of mnx 70 type 3 pole power contactor having ac-3 duty, 70a rating, ac1 -100 a rating, coil voltage- 230v ac, suitable for lighting switching applications, panel mounting, conforming to conforming to is/iec 60947-4-1 etc. complete as required., supply of isi marked, heavy duty, rigid pvc conduit, size- 25 mm dia, confirming to is 9537 (part 3) complete as required at site., supply of national flag of size 9144 mm x 6096 mm as per bis specification no is 1-1968 latest complete as required at site., supply of 18 mtr length tri-colour led rope light having transparent pvc type body material, ip65 protection, smd led strip as per lm 80/is16106, conforming to is 10322 and suitable for operation on 240 v, 50 hz single phase power supply complete as and when required. \n(make-philips/halonix/crompton/bajaj/osram), providing and fixing of temporary decorative lighting in tri-colors of national flag with led series lighting at terminal building and main gate of ayodhya airport having uniform spacing of between two rows is not to be more than 0.30 mtr for a continious three days on the occassions of republic day/independence day/diwali/new year including all wiring/connections from existing power tapping point , arrangement of required height ladder/other arrangement to work up 20 meter height , tools and plants etc complete as required at site, . (total approx. area for decoration in 1 job - 2510 sq. mtrs. (one occassion is one job) ), providing and fixing of temporary decorative lighting in tri-colors/simple colors with led strip lighting (min 10 mtr and upto 15 mtr strip) on each existing trees at ayodhya airport for a continous three days on the occassions of republic day/independence day/diwali/new year including all wiring/connections etc complete as required at site. (1 tree - 1 job)


Tender Value : 7973220
Due Date : May 14, 2026
T18 Ref No : 15315883
Location : bhubaneswar , odisha
Source : GEM Tenders

tender for supply of access points , supply of layer-2 managed switch , supply of workstation , supply of laptop , supply of poe plus adaptor , supply of 12-port liu , supply of fiber patch cords of 1 mtr length , supply of 23-awg cat-6a utp cable , supply of rj45 information outlet boxes , supply of 8-port rj45 patch panel , supply of rj45 cat-6a patch cords - 1 mtr length , supply of 25mm pvc conduits - isi marked , supply of flexible pipe , laying of cat-6a utp data cable , installation, testing, configuration, training and commissioning, supply installation testing and commissioning of wireless access points at bhubaneshwar airport, supply of access points (dual band 2x2, wifi 6 or better powered by poe/poe+) with support of minimum 2.95gpbs wireless speed and must have 01 no. 2.5g rj45 port with a hardware controller for management of access points, complete with all mounting accessories, supply of 8 x 2.5g copper ports and 4 x 10g sfp+ ports layer-2 poe+ managed switch with min. 240w power budget fully populated with 10g sfp+ transceiver modules, supply of workstation with intel core i7 14700 or amd ryzen 7 8700g processor, 32gb ddr5 5600mts ram, 1tb nvme m.2 ssd, intel q670/amd pro 665 chipset, preloaded with windows 11 professional along with 23-inch 1920x1080 resolution ips monitor or higher specification, supply of 14-inch laptop with intel core ultra 7 255u or amd ryzen 7 250 processor, 16gb ddr5 5600mts ram, 1tb nvme m.2 ssd, preloaded with windows 11 professional., supply of poe+ adaptors for wifi access points, supply of 12 ports liu with lc-lc connectors fully loaded, supply of lc-lc duplex single mode fiber patch cords of 1 mtr length, supply of 23-awg cat-6a utp cable, supply of rj45 (cat6a) information outlet boxes, supply of 8-port rj45 (cat-6a) patch panel, supply of rj45 cat-6a patch cords of 1 mtr length, supply of 25mm pvc conduits - isi marked, supply of flexible pipe, laying of cat-6a utp data cable through pvc conduits/flexible, existing conduit/pipe on surface/recess/concealed, with connectors, bends, tees, termination etc., installation, testing, configuration, training and commissioning of entire wifi system along with provision of all accessories required. training shall include on the job operation, configuration, maintenance and system administration training for it team.


Tender Value : 5970447
Due Date : May 26, 2026
T18 Ref No : 15289539
Source : GEM Tenders

tender for soq1 , soq2 , soq3 , soq4 , soq5 , soq6 , soq7 , soq8 , soq9 , soq10 , soq11 , soq12 , soq13 , soq14 , soq15 , soq16 , soq17 , soq18 , soq19 , soq20 , soq21 , soq22 , soq23 , soq24 , soq25 , soq26 , soq27 , soq28, armo of e and m installation at kushinagar international airport kushinagar for one year, periodical maintenance and operation of electrical and mechanical installations involving operation, repairs and maintenance, attending to complaints/faults/ breakdowns and taking rectification action, ensuring serviceability/satisfactory working condition of the systems, carrying-out preventive maintenance, maintenance of records/ documents etc. under this contract on all working days including saturdays, sundays and holidays as per tender specifications, terms & conditions by providing/engaging following minimum number of man power i/c reliever.\n(a) highly skilled (special repair supervisor) - 1 nos.\n(b) highly skilled (supervisor) - 1 nos.\n(b) skilled data entry operator - 1 nos.\n(c) skilled technician - 14 nos. i/c relievers\n(d) unskilled helper - 14 nos. i/c relievers\ntotal minimum manpower i/c reliever- 31 nos.\nnote- relievers shall do duty of electrician//helper as per site requirement., carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site.\nnote - empty drum will be provided by aai., servicing of l&t make, model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel, cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts, releases etc, checking the hardware for wear & tear, checking of termination & tightness, checking for all hardwares for its presence, replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope), regreasing of the acb parts as recommended by oem, refixing the acb, testing and observance for normal operation of acb complete as required.\nnote - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head., one time servicing, maintenance, testing, overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following-\nht panel - 12kv, 630 a, 21ka/3sec, 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker.\ntransformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos.\nlv componenet - 4 p, 630a, drawout acb - 01 no. 3p 400a mccb for capacitor panel \ncapacitor panel - apfc 200kvar capacitor panel- 01 nos.\npss is comprising all above i/c metering, relay etc complete. \noem service er. has to submit the relay calibration report along with service and maintenance report of transformer, rmu, ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete., carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine, di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement.\nnote - the transformer having capacity of 330 ltrs of tranformer oil., supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement., one time servicing, maintenance, testing, overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following-\nht panel - 12kv, 630 a, 21ka/3sec, 3way non extensible sf6 insulated rmucomprising of 02 nos. 630a manual load breaker switch and 01 no. 630a manual vacuum circuit breaker.\ntransformer - 11kv/0.433kv , 630 kva dry type transformer -01 nos\nlv componenet - 4p, 1250a, drawout acb-01 nos, 4p 630 a mccb-02 nos. & 3p 400 a mccb-01 nos.\ncapacitor panel - apfc 200kvar capacitor panel- 01 nos.\npss is comprising all above i/c metering, relay etc complete. \noem service er. has to submit the relay calibration report along with service and maintenance report of transformer, rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete., decoration of terminal building and atc cum admin building with decorative lights on the occasion of independence day, republic day and any other occasions as decided by eic for 04 days on each occasion on hiring (rental) basis with following type of lights and decoration accessories with provision for operation as per national flag theme (tricolour)/ occasion themes for indoor & outdoor use, including supply and installation of lights on selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required.\na) minimum 450 nos. led series riser pixel light bright (each riser of approx. 30 feet. length) (tri- colour pattern)\nb) minimum 30 nos. outdoor led focus/spot light for illumination of pillars/glazing etc.\nnote - the installation & testing of lighting systems and decoration accessories shall be completed by 0500 pm, 02 day prior to the occasion., providing and installations of decoraed themed selfie points along with focus lights on the occasion of independence day, republic day and any other occasions as decided by eic for 03 days on each occasion on hiring (rental) basis with following type of decoration accessories (selfie point) with provision for operation as per national flag theme (tricolour)/ occassion themes for indoor use, including supply and installation of selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. selfie point strength and material should be sufficient enough to sustain it for required days.\n(a) selfie point having inscription of the occasion as decided by e.i.c. of minimum size 7 x 5 x 5 feet including provision of 02 nos led focus light to focus it.\nnote - 1. the installation & fixing of selfie points shall be completed by 0500 pm, one day prior to the occasion.\n2. one location comprising selfie point etc. shall be measured as qty-1 each, decoration of terminal & atc cum admin building with decorative lights on the occasion of christmas day & newyear for 10 days on hiring (rental) basis with following type of lights and decoration accessories with provision for operation for indoor & outdoor use, including supply and installation of lights with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required.\na) minimum 450 nos. led series riser pixel light bright (each riser of approx. 30 feet. length)\nb) minimum 30 nos. outdoor led focus/spot light for illumination of pillars/glazing etc.\nnote - the installation & testing of lighting systems and decoration accessories shall be completed by 0500 pm, 02 day prior to the occasion. (pattern and colour of light as decided by eic)., decoration of terminal building with christmas tree on the occasion of christmas day/new year for 10 days on hiring (rental) basis with following type of decoration accessories (selfie point) with provision for operation for indoor use, including supply and installation of selfie point with suitable mounting arrangements, wiring / cabling, loading, unloading, transportation, dismantling etc. complete as required. selfie point strength and material should be sufficient enough to sustain it for required days.\nchristmas tree/selfie point having inscription of the occasion as decided by e.i.c. of minimum size 7 x 5 x 5 feet including provision of 02 nos led focus light to focus it.\nnote - 1. the installation & fixing of selfie points shall be completed by 0500 pm, one day prior to the occasion.\n2. one location comprising selfie point etc. shall be measure as qty-1 each, annual comprehensive maintenance contract of existing automatic bi-parting (2 leafs) sliding doors including servicing, repairing, supply and replacement of spares as per the requirement and to attend breakdown calls and quarterly visit for preventive maintenance by ensuring safe and smooth functioning of automatic sliding doors to the satisfaction of eic including technical support and spares from oem authorized service er. or equivalent manufacturer approved by eic. the automatic sliding door consists of automation systems make by geze (motor,controller,electronic components, power transmitting device, belt clamp , rollers, cable winder, cables, all safety devices, stoppers etc and i/c all other accessories and parts. the work involves quarterly visit and as and when required by service engineer for doors, carrying out preventive and scheduled maintenance as per oem recommendation and special condition of contract., annual comprehensive maintenance contract of existing 1x20 kva alpha-33 ups (pegasus make unle190361) through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares(except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem or oem authorised dealer only strictly as per the scope of work of special condition of contract., annual comprehensive maintenance contract of existing 20 kva ups (riello make ups s3t 20cpt model) through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares (except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem or oem authorised dealer only strictly as per the scope of work of special condition of contract., annual comprehensive maintenance contract of existing 100 kva ups (vertiv make ups liebert exm series model) in substation for glf through oem & oem authorised service dealer only including servicing, repairing, supply and replacement of spares (except battery- battery shall be provided by aai if required) as per the requirement and quarterly preventive maintenance visits (minimum four visit in a year) and breakdown visits through oem only strictly as per the scope of work of special condition of contract., rewinding of ceiling fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of ceiling fan for 06 months and dismantled material shall be the property of tenderer., rewinding of wall mount fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of wall mount fan for 06 months and dismantled material shall be the property of tenderer., rewinding of exhaust fan as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of exhaust fan for 06 months and dismantled material shall be the property of tenderer., rewinding of monoblock pump upto 1 hp capacity as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of monoblock pump upto 1 hp capacity for 06 months and dismantled material shall be the property of tenderer., rewinding of sewage / mud pump upto 2 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of sewage / mud pump upto 2 hp for 06 months and dismantled material shall be the property of tenderer., rewinding of submersible motor pump upto 2 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of submersible motor pump upto 2 hp for 06 months and dismantled material shall be the property of tenderer., rewinding of submersible motor pump more than 2 hp & upto 5 hp as per original characteristics with super enameled copper wire and e class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangement for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc.\n(to be carried out as & when required).\nnote - agency shall be responsible for rewinding and repairing of submersible motor pump more than 2 hp & upto 5 hp for 06 months and dismantled material shall be the property of tenderer., lifting and lowering of submersible pump motor set upto 5hp capacity from the depth upto 80 feet including dismantling of the column pipe, cable etc and reinstallation of pump and motor set in the bore well along with all necessary work like providing and fixing of required gasket & nut bolts, and welding & threading of gi pipe and flange etc as required and making connection to the discharge line after dry revolution test complete as required., re-calibration of available clinometer of ama make from the original equipment manufacturer (oem) for papi calibration, including packing, forwarding, transit insurance, and transportation charges for both dispatch and return at kushinagar international airport, kushinagar., sampling and testing of inlet and treated water from stp at kushinagar airport through a government-approved/authorized laboratory on quarterly basis. analysis to include the following parameters- ph, bod, cod, tss, oil & grease, total dissolved solids (tds), bacteriological - e. coli. submission of detailed test report., repainting of existing cylinderical steel electric poles of perimeter lights with round bracket (up to 3 m height) with one coat epoxy primer and two coats epoxy paint by spray machine or manual by labour , including surface preparation, removal of rust/old paint, cleaning, curing, ladders/scaffolding, protection of nearby fittings, and all labour, materials and equipment, complete as per specifications and engineer-in-charges direction., repainting of existing lt panel with one coat epoxy primer and two coats epoxy paint by spray machine, including surface preparation, removal of rust/old paint, cleaning, curing, protection of adjacent equipment, and all labour, materials, tools & tackles, complete as per specifications without hampering the operations and engineer-in-charges direction., execution of works as per cpwd carrying out any item of dsr (e&m)-2022 works as per site requirement complete as required for attending repair and maintenance, breakdowns and upkeep of internal and external electrical installations as per direction of engineer-in-charge at all locations under kushinagar international airport conforming to cpwd general specifications for electrical works part-i (internal) 2013, part-ii (external) 1994 and part -iv (substation) 2013, and also to relevant bis specifications.\nthe bidder shall quote the rate in inr only for the job corresponding to the base rate (rs. 1,00,000 i/c gst as per proposed estimate) and percentage (percentage) above / below shall be calculated by aai based on quoted rate w.r.t base rate and will be paid as per payment methodology given in annexure- b.\nfor example - if agency desires to quote 5 percentage above on dsr-2022 rates, the rate column shall be filled as rs. 1,05,000.00 i/c gst & if agency desires to quote 5 percentage below on dsr-2022 rates, the rate column shall be filled as rs.95,000.00 i/c gst.\nnote - payment on dsr work shall be paid as per payment methodology given at page no. as annexure-b.


Tender Value : 12659634
Due Date : May 19, 2026