Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

Ac cooling pump repair Tenders List

Latest Ac cooling pump repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Ac cooling pump repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Ac cooling pump repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Ac cooling pump repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Ac cooling pump repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Ac cooling pump repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Ac cooling pump repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Ac cooling pump repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Ac cooling pump repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Ac cooling pump repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Ac cooling pump repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Ac cooling pump repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Ac cooling pump repair tenders.

Is EMD mandatory for all Ac cooling pump repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Ac cooling pump repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Ac cooling pump repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Ac cooling pump repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 14994829
Location : omalur , tamil nadu
Source : GEM Tenders

tender for e1 , e2 , e3 , e4 , e5 , e6 , e7 , e8 , e9 , e10 , e11 , e12 , e13 , e14 , e15 , e16 , e17 , e18 , e19 , e20 , e21 , e22 , e23 , e24 , e25 , e26, facility management contract of e and m installations of salem airport, monitoring and maintenance of utility services/internal and external electrical services at salem airport comprising of lt panels, dg sets, ccr panels, runway lighting, high masts, perimeter lighting, indoor and outdoor light fittings, power points, circuit/submain wiring, dbs, aviation obstruction lights, lightning arrestors, street light poles/external lights, signages etc., (as per annexure-3 to 5 - list of inventories ) on duty basis by deputing sufficient number of manpower as per annexure-1 (8 hours of duty of time as decided by engineer-in-charge), monitoring, control and general maintenance for 100% serviceability and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of equipments/ repairs/ replacement of defective components with aai supplied new components, ensuring 100% serviceability/ satisfactory working condition of the systems, routine and general preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/ yearly basis as per standard manufacturers practices and as per techno commercial specifications (tcs), maintenance of records and log books (as per annexure-6 to 20) and reporting as and when required, complete upkeeping of the installations etc., on all days as specified and as directed by engineer-in-charge as required., maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming, repairs and maintenance, attending faults of systems, replacement of defective components with aai supplied new components, ensuring 100% serviceability/satisfactory working condition of fas, routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices, break-down maintenance, maintenance of records/service reports and reporting as and when required, complete up-keeping of the installations (fas), as specified and as directed by engineer-in-charge as required. for first year (terminal building & technical block (make- edwards, model-io-1000)), maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming, repairs and maintenance, attending faults of systems, replacement of defective components with aai supplied new components, ensuring 100% serviceability/satisfactory working condition of fas, routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices, break-down maintenance, maintenance of records/service reports and reporting as and when required, complete up-keeping of the installations (fas), as specified and as directed by engineer-in-charge as required. for first year (ndb room (make- edwards, model-io-64)), maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming, repairs and maintenance, attending faults of systems, replacement of defective components with aai supplied new components, ensuring 100% serviceability/satisfactory working condition of fas, routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices, break-down maintenance, maintenance of records/service reports and reporting as and when required, complete up-keeping of the installations (fas), as specified and as directed by engineer-in-charge as required. for second year (terminal building & technical block (make- edwards, model-io-1000)), maintenance of addressable type fire alarm system (fas) (by oem/authorized dealer of oem) including all associated and auto dialer of all fas types/models/make installed at following locations including programming, repairs and maintenance, attending faults of systems, replacement of defective components with aai supplied new components, ensuring 100% serviceability/satisfactory working condition of fas, routine and general preventive maintenance on monthly/quarterly/half yearly/yearly basis as per standard manufacturers practices, break-down maintenance, maintenance of records/service reports and reporting as and when required, complete up-keeping of the installations (fas), as specified and as directed by engineer-in-charge as required. for second year (ndb room (make- edwards, model-io-64)), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for first year (1.5 tr wallmounted split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for first year (2 tr wallmounted split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for first year (3 tr tower type split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for first year (4 tr cassette type split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for second year (1.5 tr wallmounted split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for second year (2 tr wallmounted split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for second year (3 tr tower type split ac), comprehensive maintenance of following capacity air conditioners of all makes at different locations including and providing all necessary consumables and spares complete as required as per special conditions. for second year (4 tr cassette type split ac), cmc of 50lph, 80 ltr tank capacity, water dispensers of normal, cool and hot mode with inbuilt ro & uv at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. first year, cmc of 50lph, 80 ltr tank capacity, water dispensers of normal, cool and hot mode with inbuilt ro & uv at various locations including and providing all necessary consumables and spares as per special conditions, including quarterly replacement of all filters and yearly replacement of membranes etc., complete as required. secound year, decorating the airport terminal building with led decorative serial light of 250 coils each coil of minimum 40 led lamps, running design dispaly, running serial belt of 05 coils preferably in tri colour pattern on the occasion of independence day / republic day each time for 3 days including prefix & suffix to the actual day of function etc.as required., providing decorative illumination with multicolour led colour wash flood light of minimum 10 nos for independence day / republic day with required cables and all accessories to illuminate the facia of the buildings each time for 3 days including prefix & suffix to the actual day of function etc.as required as directed by the engineer -in- charge., lifting of submersible pumps of various capacities from the existing bore well/well and reinstalling the submersible pumps in the existing bore well / well (after servicing / repairing both are exclusive) complete as required., rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. upto 3 hp, rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 5 to 6 hp, rewinding of following capacity submersible pumps including replacement of damaged parts such as inlet bese, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required. 10 hp, repair & rewinding of 1400 / 1200 mm sweep ceiling fan i/c replacement of spares as required., repair & rewinding of all capacities of exhaust fan i/c replacement of spares as required., painting of electrical panels, ccr panels, glf fixtures, dgs and street light poles etc., installations with two coats of synthetic enamel paint of approved shade quality and brand after applying two coats of redoxide i/c scrapping and cleaning, providing putty wherever required and inscription etc., as required., execution of items of schedule of rates cpwd dsr-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of e-i-c at different locations in operational area/terminal building/colony as per the special terms and conditions in addition to general terms and conditions of contract as required. the bidder shall quote the rate for 01 (one) job corresponding to the value of rs.2,36,000/- (inclusive of gst) in inr only and percentage above / below shall be calculated by aai and paid accordingly. note- the rate provided in dsr 2022 is inclusive of gst at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including gst, the payment shall be made to contractor as mentioned in special conditions of tender document. for first year, execution of items of schedule of rates cpwd dsr-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of e-i-c at different locations in operational area/terminal building/colony as per the special terms and conditions in addition to general terms and conditions of contract as required. the bidder shall quote the rate for 01 (one) job corresponding to the value of rs. 2,36,000/- (inclusive of gst) in inr only and percentage above / below shall be calculated by aai and paid accordingly. note- the rate provided in dsr 2022 is inclusive of gst at the rate of 12 percentage, however the contractor has to quote the amount in rate column, including gst, the payment shall be made to contractor as mentioned in special conditions of tender document. for second year


Tender Value : 13878263
Due Date : May 01, 2026
T18 Ref No : 14928464
Location : tura , meghalaya
Source : GEM Tenders

tender for 1.5 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr cassette type split air conditioners inverter model 5 star , reprigerent pipe for 1.5 split ac , reprigerent pipe for 2.0 tr cassette ac , 4 kva stabilizer for split ac , 5 kva stabilizer fo cassette ac , additional drain water pipe, air conditioning work at sbi songsak branch, supply, testing, commisioning & installation of 1.5 tr capacity hi wall mounting 5-star rated inverter split ac with cordless remote and copper condensor coil. ac make, voltas/bluestar /carrier/daikin /lg/godrej(including repairing of damage while installation) and 3 meter copper pipe, supply, testing, commisioning & installation of 2 tr cassette type inverter ac, 5 star with copper condensor coiland refrigerant (r32 or r 410a) indoor unit ceiling hung comprising cooling coil, evaporator fan with motor, filters, insulated drain pan, drain pump, expansion valve, refrigerant filter drier with codeless remote control unit, etc. outdoor unit comprising single phase hermetically sealed scroll / rotary compressors, condenser coil with fan & motor, starters / controls / cutouts / relays etc., mounted inside a powder coated sheet metal cabinet of 2mm thick, duly treated for corrosion protection complete, mounted on ribbed rubber pads. ac make, voltas/blue star/carrier/daikin /lg, for 1.5 tr copper type split air conditioners supply and laying of copper pipes, drain pipes (covered with gi pipes wherever necessary), copper wiring in gi conduits neatly drawn in professional manner from power points to outdoor / indoor units complete with all necessaries and making good all the damages., for 2 tr copper cassette type split air conditioners supply and laying of copper pipes, drain pipes (covered with gi pipes wherever necessary), copper wiring in gi conduits neatly drawn in professional manner from power points to outdoor / indoor units complete with all necessaries and making good all the damages., supply and installation of 4 kva stabilizer for 1.5 tr hi-wall split ac(130 v to 270v), supply and installation of 5 kva stabilizer for 2.0 tr hi-wall split ac(130 to 270 v), supply and installation of additional drain water upvc pipe for properly connecting to the drain point


Agency / Dept : state bank of india SBI
Tender Value : 521000
Due Date : Apr 25, 2026
T18 Ref No : 15247132
Location : new delhi , delhi
Source : GEM Tenders

tender for operation of microprocessor based hvac system , all inclusive comprehensive maintenance , replacement of damaged and worn out control and power wiring , dismantling and replacement of existing faulty 2 amp dp mcb , dismantling and replacement of existing faulty mpcb ms 116 , replacement of burnt broken and rusted terminal block , dismantling and replacement of following sizes of existing worn out faulty pipe 200mm dia 32 mm thick insulation , 150mm dia 32 mm thick insulation , 125mm dia 32 mm thick insulation , 100mm dia 32 mm thick insulation , 80mm dia 32 mm thick insulation , 65mm dia 32 mm thick insulation , dismantling and replacement of following sizes of existing worn out ndustrial type pressure gauges , providing and fixing in position the mercury in glass industrial type thermometers , butterfly valve manual with c i body ss disc a 150 mm dia , 100 mm dia , dismantling and replacement of following existing worn out faulty tpmccb 100 a 16 ka tpmccb , 200 a 25 ka tpmccb , 630 a 50 ka tpmccb , 800 a 50 ka tpmccb , making suitable modification replacement of overheated existing aluminium bus bar , dismantling and replacement of existing worn out faulty paddle type water flow , attending leakage in the existing chilled water pipeline , replacement of the following items of existing electrical panels mnx 32 contactor make l andtac plant room , mnx 25 contactor make l andt , 2noplus2 nc add on blockmake l andt , overload relay mn 2 of range 9 to 15 amps make l andt , single phase preventer , on off push button with elements , led indication lampr y b g , 3 way selector switch , star delta timer , digital voltmetermake select or ss , digital ammeter make select or ss , v belt , painting of existing old electrical panel, om hvac bsb janpath nd, operation of microprocessor based hvac system of capacity 5 x 100 tr chilling machines with screw compressors and air cooled condensers as detailed in annexure a and ductable tower type split ac and split ac as detailed in annexure b by deputing the following staff \n skilled semi skilled unskilled \n6 am to 2pm 1 1 2\n2 pm to 10 pm 1 1 2\ngeneral shift 9 am to 5 pm 1 0 0\nnotes \n1 staff may be asked to work in any shift and any day without any extra cost \n2 bill processed receipt proof online salary transfer account epf esi contr presently 12 perct and 3 25 perct ofpay respas reqt \n3 if esi and epf contributions rescission work initiated \n4 staff deployed enrolled attendance system\n5 the contractor ensure personnel meet defined standards f\n6 operation of the pumps 7 operation of ahus and tfa \n8 oper electrical panels\n9 recording readings chillers ahus pumps digital temperature meter \n10 to attend the floor complaints \n11 weekly washing ahus filters and ahus room\n12 chemical cleaning ahus cooling coil\n13 general checking testing and attending minor faults 14 out of skill manpower one skill operator electrician\n15 to carry out leak test compressors condenser coil with soap items are as per schedule of work item 1, all inclusive comprehensive maintenance of following items as per inventory at per annexure b given in relevant sections up to the required standards etc as per specification the items are \n1 ductable ac units\n2 tower split ac units\n3 split ac units \n items are as per schedule of work item 2, replacement of damaged and worn out control and power wiring of star delta starter panel for one motor in existing ahus electrical panel with new pvc insulated copper conductor wires of suitable size including providing and fixing of thimbles ferrules and new insulated fiber sheet for proper insulation removing of existing contactors cleaning and re fixing the same in position after proper checking and tightening of all connections complete as required items are as per schedule of work item 3, dismantling and replacement of existing faulty 2 amp dp mcbs in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 4, dismantling and replacement of existing faulty mpcb ms 116 in existing star delta starter panels of chilled water pumps on both primary and secondary sides i c testing etc complete as required items are as per schedule of work item 5, replacement of burnt broken and rusted terminal block 63 amp rating along with 2 nos lugs in the existing electrical panel of ahu s chilled water pump s etc complete as required items are as per schedule of work item 6, dismantling and replacement of following sizes of existing worn out faulty pipe at different floors levels i c supplying laying fixing testing and commissioning of nominal sizes of chilled water piping inside the building with necessary clamps vibration isolators and fittings but excluding valves strainers gauges etc duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg cu m density thermal conductivity 0 037 w mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc as per specifications and as required complete in all respect \nnote the pipes of sizes 150mm and below shall be m s c class as per is 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is 3589 from minimum 6 35mm thick m s sheet for pipes upto 350 mm dia and from minimum 7mm thick ms sheet for pipes of 400 mm dia and above \na 200mm dia 32 mm thick insulation items are as per schedule of work item 7 a, 150mm dia 32 mm thick insulation items are as per schedule of work item 7 b, 125mm dia 32 mm thick insulation items are as per schedule of work item 7 c, 100mm dia 32 mm thick insulation items are as per schedule of work item 7 d, 80mm dia 32 mm thick insulation items are as per schedule of work item 7 e, 65mm dia 32 mm thick insulation items are as per schedule of work item 7 f, dismantling and replacement of following sizes of existing worn out faulty components at different floors levels i c supplying fixing testing and commissioning of valves gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications 8 1 providing and fixing in position the industrial type pressure gauges with gun metal brass valves complete as required items are as per schedule of work item 8 1, providing and fixing in position the mercury in glass industrial type thermometers items are as per schedule of work item 8 2, butterfly valve manual with c i body ss disc nitrile rubber seal and o ring pn 16 pressure rating for chilled water hot eater circulation as specified a 150 mm dia items are as per schedule of work item 8 3 a, 100 mm dia items are as per schedule of work item 8 3 b, dismantling and replacement of following existing worn out faulty tpmccb at different floors levels i c fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections ics100 perc icu and operational voltage 690v etc as required 100 a 16 ka tpmccb items are as per schedule of work item 9 a, 200 a 25 ka tpmccb items are as per schedule of work item 9 b, 630 a 50 ka tpmccb items are as per schedule of work item 9 c, 800 a 50 ka tpmccb items are as per schedule of work item 9 d, making suitable modification replacement of overheated existing aluminium bus bar links suitable to fit 630 800ampcapacity tp mccb i c cutting bending pvc sleeving testing commissioning etc complete as per site requirement items are as per schedule of work item 10, dismantling and replacement of existing worn out faulty paddle type water flow switch at different floors levels i c installation testing and commissioning with micro switch contacts and retard mechanism complete in all respects as required items are as per schedule of work item 11, attending leakage in the existing chilled water pipeline of various diameters including cutting of damaged portion edge preparation welding testing and making the pipeline operational including providing and fixing necessary scaffolding ladders safety arrangements for working at heights ranging from 15 feet to 100 feet in shaft area cleaning the pipe surface applying anti corrosive paint on welded joints and restoring the system to its original condition complete as required items are as per schedule of work item 12, replacement of the following items of existing electrical panels i c identifying and rectifying the fault dismantling of existing defective parts fixing connections testing etc as required a mnx 32 contactor make l andt ac plant room items are as per schedule of work item 13 a, mnx 25 contactor make l andt items are as per schedule of work item 13 b, 2noplus2 nc add on block make l andt items are as per schedule of work item 13 c, overload relay mn 2 of range 9 to 15 amps make l andt items are as per schedule of work item 13 d, single phase preventer items are as per schedule of work item 13 e, on off push button with elements items are as per schedule of work item 13 f, led indication lamp r y b g items are as per schedule of work item 13 g, 3 way selector switch items are as per schedule of work item 13 h, star delta timer items are as per schedule of work item 13 i, digital voltmeter make select or ss items are as per schedule of work item 13 j, digital ammeter make select or ss items are as per schedule of work item 13 k, v belt items are as per schedule of work item 13 l, painting of existing old electrical panel without dismantling including masking covering of indicators meters switches surface cleaning rust removal 1 coat red oxide primer plus synthetic enamel spray paint and finishing etc as required items are as per schedule of work item 14


Tender Value : 7391777
Due Date : May 19, 2026
T18 Ref No : 15285750
Location : mathura , uttar pradesh
Source : GEM Tenders

corrigendum tender for description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description , supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description , supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description , supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description , supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description , supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description , gi pipe medium grade of 50 mm dia , gi pipe medium grade of 20 mm dia , gi pipe medium grade of 15 mm dia , supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description , m and l for duct insulation with 25 mm thick all as per description , m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation , m and l for supply air grilis with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation , m and l for return air grills with extruder aluminium powder coated without air volume control shall be provided as per oem recommendation , dismantling old false ceiling any type as per description , supply and installation 3 way valve of ci of size 80 mm dia , demolition of brick work or floor as per description , m and l for brick work with sub class b brick straight or curved as per description , m and l for plastering 12 mm thick on fair faces of brick as per description , m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed , m and l for 100 mm bore steel tubing light grade complete all as specified and as directed , supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conductor including termination complete as specified and directed , m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground with 32 x 6 mm gi strip , supply installation testing and commissioning of lt control panel board cubical type indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca, special repair to replacement of 03 x 25 central ac plant in signal centre under ge west mathura, disconnecting and taking down complete central ac plant capacity 25 tr x 3 nos with ahu 01 cooling tower duct and complete connected accessories as per diiscription, design supply installation testing and commissioning of central air conditioning plant of working capacity not less than 2 x 25 or 26 tr working pluse 1 stand by as per design provided by bidder all as per diiscription, supply installation commissioning and testing of monoblock centrifugal pump 2 w pluse1 s of capacity suitable for 50 tr central ac plant and design by vendor, supply installation commissioning 440 v 50 hz of monoblock centrifugal pump 2 w pluse 1 s of capacity suitable for 50 tr central ac plant and design by vendor, supply installation commissioning and testing of frp cooling tower rectagular round bottle shape suitable for capacity 50 tr ac plant with frp body and design by vendor, supply installation self commissioning and testing of factory built double skinned sandwiched with 25 mm fiber glass or thermo coal or puff insulation section type horizontal ahu with six row deep coil suitable for 50 or 52 tr as per description, supply and installation hot water generator 35 kw with 2 nos pump 1 w pluse1 s alongwith making necessary connections complete all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 100 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 80 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 65 mm all as per description, supply and fixing mild steel c grade pipe heavy duty of dia 50 mm all as per description, supply and installation butterfly valve of ci of size 100 mm as per latest is and description, supply and installation butterfly valve of ci of size 80 mm as per latest is and description, supply and installation butterfly valve of ci of size 65 mm as per latest is and description, supply and installation butterfly valve of ci of size 50 mm as per latest is and description, supply and installation non return valve nrv of ci of size 80 mm as per latest is and description, supply and installation non return valve nrv of ci of size 65 mm as per latest is and description, supply and installation non return valve nrv of ci of size 50 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 20 mm as per latest is and description, supply and fixing stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle, of dia 15 mm as per latest is and description, supply and fixing mild steel pot strainer of 100 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 80 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 65 mm bore as per latest is and description, supply and fixing new mild steel ystrainer of 50 mm bore as per latest is and description, supply and installation pressure gauge in the pipe lines suitable for dia 15 mm pipe as per latest is and description, supply and installation thermometers in the pipe line suitable for dia 15 mm as per latest is and description, gi pipe medium grade of 50 mm dia, gi pipe medium grade of 20 mm dia, gi pipe medium grade of 15 mm dia, supply assembly and erection of pgi sheet with tdf flange of thickness 22 gauge sheet as per description, m and l for duct insulation with 25 mm thick all as per description, m and l for wraping glass cloth incl uv chemical coating over nitrile rubber. thickness of glass cloth shall be provided as per oem recommendation, m and l for suitable size of supply air grilis as per size of supply air grills as per manufacturers design with extruder aluminium powder coated and size and type of air grills alongwith air volume shall be provided as per oem recommendation, providing suitable size of return air grills as per manufacturers design with extruder aluminium powder coated without air volume control and size of return air grills shall be provided as per oem recommendation, dismantling old false ceiling any type as per description, supply and installation 3 way valve of ci of size 80 mm dia, demolition of brick work or floor as per description, m and l for brick work with sub class b brick straight or curved as per description, m and l for plastering 12 mm thick on fair faces of brick as per description, m and l 150 mm thick cement concrete 1 ratio 2 ratio 4 type b2 40 mm graded broken stone aggregate as per description, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 150 sq mm 3 and half core as specified and directed, m and l for 100 mm bore steel tubing light grade complete all as specified and as directed, supply laying testing xlpe cable insulated heavy duty 1100 volts aluminium conductor of size 95 sq mm 3 and half core as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 50 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 3 point 5 core x 35 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for xlpe insulated armoured ug cables 4 core x 16 sqmm 1100 volts grade aluminium conduct including termination complete as specified and directed, m and l for earthing complete with gi earth plate electrode 600 x 600 x 6 mm thick burried directly in ground rate for gi strip and protection pipes upto 7 poinr 5 mtr shall be inclussive in rate to be quoted against this items., supply installation testing and commissioning of lt control panel board cubical type 415 volt 3 phase 50 hz indoor type floor mounted weather proof fabricated out of 2 point 0 mm crca sheet ae per drawing


Agency / Dept : indian army
Tender Value : 0
Due Date : May 29, 2026
T18 Ref No : 15316114
Location : imphal , manipur
Source : GEM Tenders

tender for 1.5 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr cassette type split air conditioners inverter model 5 star , installation charges of the 1.5 tr split type ac , installation charges of the 2.0 tr cassette split ac , reprigerent pipe for 1.5 split ac , reprigerent pipe for 2.0 tr cassette ac , 4 kva stabilizer for split ac , 5 kva stabilizer fo cassette ac , additional drain water pipe, air conditioning work at sbi uripok branch, supply of 1.5 tr capacity hi wall mounting 5-star rated inverter split ac with cordless remote and copper condensor coil. ac make, voltas/bluestar /carrier/daikin /lg/godrej(including repairing of damage while installation) and 3 meter copper pipe, supply of 2 tr cassette type inverter ac, 5 star with\ncopper condensor coiland refrigerant (r32 or r 410a) indoor unit ceiling hung comprising cooling coil, evaporator fan with motor, filters, insulated drain pan, drain pump, expansion valve, refrigerant filter drier with codeless remote control unit, etc. outdoor unit comprising single phase hermetically sealed scroll / rotary compressors, condenser coil with fan & motor, starters / controls / cutouts / relays etc., mounted inside a powder coated sheet metal cabinet of 2mm thick, duly treated for corrosion protection complete, mounted on ribbed rubber pads. ac make, voltas/blue star/carrier/daikin /lg, installation charges of the 1.5tr hi-wall split ac including outdoor frame / stands to withstand the full load of outdoor units and making good all the damageincluding removal of existing ac unit for replacement., installation charges of the 2 tr cassette split ac including outdoor frame / stands to withstand the full load of outdoor units and making good all the damage including removal of existing ac unit for replacement., for 1.5 tr copper type split air conditioners supply and laying of copper pipes, drain pipes (covered with gi pipes wherever necessary), copper wiring in gi conduits neatly drawn in professional manner from power points to outdoor / indoor units complete with all necessaries and making good all the damages., for 2 tr copper cassette type split air conditioners supply and laying of copper pipes, drain pipes (covered with gi pipes wherever necessary), copper wiring in gi conduits neatly drawn in professional manner from power points to outdoor / indoor units complete with all necessaries and making good all the damages., supply and installation of 4 kva stabilizer for 1.5 tr hi-wall split ac(130 v to 270v), supply and installation of 5 kva stabilizer for 2.0 tr hi-wall split ac(130 to 270 v), supply and installation of additional drain water upvc pipe for properly connecting to the drain point


Agency / Dept : state bank of india SBI
Tender Value : 542210
Due Date : Jun 01, 2026