Latest Tender Detail from department of health and family welfare DOHAFW for the corrigendum tender for 1 long guiding sheath for radial access with id point 088inches with hvdrophilic coating , 2 long guide sheath 6f point088inches for femoral use , 3 intermediate catheter 070inches for intracranial neurovascular use available in id 035inches to 070inches , 4 dmso compatible detachable tip microcatheter with distal 1point5f for avm embolization with wire also available in 1point 2f distal diameter , 5 intrasaccular aneurysm device for neurovascular use , 6 dual lumen extracompliant balloon catheter for intracranial use 4x11 mm , 7 neurovascular detachable coils 3d with expandable coating latest generation , 8 electrolytically detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 9 electrothermally detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation , 10 nitinol flow diverter withdrawn filled tubing for cerebral aneurysms latest generation , 11 microcatheter 0165 for endovascular coiling of aneurysms 2point4f proximal 1point7f distal with 2 tip markers , 12 dual layer hydrophilic coated 021 inches rocutfretinches for neurovascular device delivery , 13 microcatheter 027inches for deployment of intracranial device , 14 liquid embolic agent 18psi evoh based for avm embolization available in 12 and 18 concentration 1point5 ml , 15 mechanically detachable coil for intracranial aneurysm coiling they should be latest generation of varying sizes coil detacher if required should be provided , 16 microguidewire , 17 remodelling balloon , 18 flow diverter low profile flow diverter , 19 dual compatible microcatheter for aneurysm coiling and avm embolization 156 cm and 167 cm lengths , 20 microguidewire for liquid embolics , 21cobalt chromium flow diverter , 22 stent retriever with parametric design 021inches compatible with at least 3 distal and 1 proximal radio opaque marker and multiple markers along the length of the device for better visibility , 23 aspiration catheter for mechanical thrombectomy zero point 072 inches, dsa consumable for neurointervension, long guiding sheath for radial access with id point 088inches with hvdrophilic coating, long guide sheath 6f point 088 inches for femoral use, 070inches intermediate catheter for intracranial neurovascular use available in id 035inches to 070inches, dmso compatible detachable tip microcatheter with distal 1point5f for avm embolization with wire also available in 1point 2f distal diameter, intrasaccular aneurysm device for neurovascular use, dual lumen extracompliant balloon catheter for intracranial use 4x11mm, 3d neurovascular detachable coils with expandable coating latest generation, electrolytically detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation, electrothermally detachable neurovascular 360 degree coils compatible with 017inches microcatheter latest generation, nitinol flow diverter withdrawn filled tubing for cerebral aneurysms latest generation, microcatheter 0165 for endovascular coiling of aneurysms 2point4f proximal 1point7f distal with 2 tip markers, dual layer hydrophilic coated 021 inches microcatheter for neurovascular device delivery, 027inches microcatheter for deployment of intracranial device, 18psi liquid embolic agent evoh based for avm embolization available in 12 and 18 concentration 1point5 ml, mechanically detachable coil for intracranial aneurysm coiling they should be latest generation of varying sizes coil detacher if required should be provided, 0point 14inches hydrophilic microwire for neurovascular use with soft tapered distal tip with proximal docking attachment system, single lumen 0 point 010 compatible balloon for wide neck side wall aneurysms, low profile flow diverter with 48 braided wires for neurovascular use with 0point 017inches compatibility, microcatheter with dual compatibility for aneurysm coiling and avm embolization in 156 cm and 167 cm lengths, 0point008 microguidewire for avm treatment, cobalt chromium flow diverter with phosphorylcholine coating for cerebral aneurysms latest generation cobalt chromium flow diverter with phosphorylcholine coating for cerebral aneurysms latest generation, stent retriever with parametric design 021inches compatible with at least 3 distal and 1 proximal radio opaque marker and multiple markers along the length of the device for better visibility, aspiration catheter for mechanical thrombectomy zero point 072 inches in new delhi, delhi,. Reference number 17414512. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.