Latest Tender Detail from indian army for the tender for plate finial taper plug bolt nut screw complete all as specified type 410 sp 31 of 9m long as per atc , supply only in replacement hv bushing 11 kv for transfermores up to capacity 160 kva complete all as specified and directed , supply only in replacement v bushing 0 point 433 or 0 point 415 kv for transformer up to rating 160 kva complete all as specified and directed , supply only in replacement hv spindle metal part made out of brass with nuts and washer complete for transformer of capacity upto 160 kva complete all as specified and directed , supply only in replacement lv spindle metal part made out of brass with nuts and washers complete for transformer of capacity upto 160 kva complete all as specified and directed , supply fill and top up new transformer oil low viscosity type of dielectric strength 35 to 40 kv breaking voltage confirming to is complete for indoor or outdoor transformer in various sub as per atc , s andf in replacement silica gel breather transparent type with silica gel complete suitable for up to 160 kva transformer rating all as specified , s and f in replacement dial type thermo meter of minimum 10mm dia with maximum temperature indicator for transformer of capacity up to 160 kva all as specified and directed , supply only in replacement tap changer switch complete with handle for transformer of capacity upto 160 kva , supply only in replacement fixed contact block of vcb 630 amps 11 kv incl taking down old material , supply only in replacement support insulator 75mm dia of vcb 630 amps 11 kv , supply only in replacement auxiliary switch 6no plus 6nc of vcb 630 amps 11 kv , supply only in replacement solenoid closing coil 3 or 110 v dc suitable for type v 207g vcb 630 a vmx breaker , supply fix and connect in replacement announciator suitable for 11 kv indoor control panel with necessary writing and testing on completion complete all as specified and directed , supply only in replacement charging motor for high tension 11 kv vcb panels 400 amps operated on 230 volts ac or 30 volts dc as per sample complete all as specified and directed by eic , supply only in replacement upper spout ht 11 kv vcb as per sample and fixing on panel all as required at site complete all as specified and directed , supply only in replacement male contact made of tinned copper vcb 11 kv made of brass as per sample and fixing testing all as required and directed at site complete all as specified and directed , s and f in replacement resin or epoxy coated air cooled high tension current transformer of dual ratio of 200 to 100 or 5amps 10va burden out put accuracy clas 0 point 5 suitable for rated as per atc , s and f in replacement over current earth fault relay having auxiliary voltage 24 to 110 volts plus 15 percent ac or dc complete all as specified and directed , s and f in replacement panel lighting lamp with holder with on or off toggle switch complete all as specified and directed , s and f in replacement bakelite hrc fuses in control or vcb panels complete all as specified and directed , s and f in replacement breaker control switch suitable for 11 kv control panel and outdoor vcbs complete all as specified and directed incl taking down old complete all as specified and directed , s and f in replacement digital multifunctional meter as per existing or as approved by the ge complete all as specified and directed , s and f in replacement selector switch for various type of control panels as per existing complete all as specified and directed , s and f in replacement switch air break gang operated, s and f of lt ug cable xlpe at 43 weu ramgarh jaisalmer, supply laying and commissioning in replacement of lt ug cable 4 core x 16 sqmm xlpe sheathed pvc insulated screened pvc bedded galvanized steel strip of wire armd electric power as per atc, supply laying and commissioning in replacement of lt ug cable 3 point 5 core x 35 sqmmxlpe sheathed pvc insulated screened pvc bedded galvanized steel strip of wire armoured as per atc, supply laying and commissioning in replacement of lt ug cable 3 point 5 core x 50 sqmm xlpe sheathed pvc insulated screened pvc bedded galvanized steel strip of wire armoured as per atc, supply laying and commissioning in replacement of lt ug cable 3 point 5 core x 70 sqmm xlpe sheathed pvc insulated screened pvc bedded galvanized steel strip of wire armoured as per atc, supply laying and commissioning in replacement of lt ug cable 3 point 5 core x 120 sqmm xlpe sheathed pvc insulated screened pvc bedded, galvanized steel strip of wire armoured as per atc, supplying and laying unreinforced precast concrete cable cover class lv typei flat size 250mm x 150mm x 40mm complete all as specified and as directed, supply and fixing in replacement energy efficient led street light fitting of 70w pressure die cast aluminum housing or body heat resistant clear toughened glass better optics for uniform as per atc, supply and fix junction box in replacement made out of frp with ip 55 or ip 65 protection of size not less than 200 x 140 x 95 mm inside dimension having 5 terminal mounted on din as per atc, supply and fixing in replacement connecting elastomer insulated flat sheathed mutlicore industrial flexible cable 1 point 5 sqmm 3 corewith bright annealed copper conductor 1100v as per atc, supply erecting steel tubular poles in replacement pcc or rcc poles complete with cast iron base plate finial taper plug bolt nut screw complete all as specified type 410 sp 31 of 9m long as per atc, supply only in replacement hv bushing 11 kv for transfermores up to capacity 160 kva complete all as specified and directed, supply only in replacement v bushing 0 point 433 or 0 point 415 kv for transformer up to rating 160 kva complete all as specified and directed, supply only in replacement hv spindle metal part made out of brass with nuts and washer complete for transformer of capacity upto 160 kva complete all as specified and directed, supply only in replacement lv spindle metal part made out of brass with nuts and washers complete for transformer of capacity upto 160 kva complete all as specified and directed, supply fill and top up new transformer oil low viscosity type of dielectric strength 35 to 40 kv breaking voltage confirming to is complete for indoor or outdoor transformer in various sub as per atc, s andf in replacement silica gel breather transparent type with silica gel complete suitable for up to 160 kva transformer rating all as specified, s and f in replacement dial type thermo meter of minimum 10mm dia with maximum temperature indicator for transformer of capacity up to 160 kva all as specified and directed, supply only in replacement tap changer switch complete with handle for transformer of capacity upto 160 kva, supply only in replacement fixed contact block of vcb 630 amps 11 kv incl taking down old material, supply only in replacement support insulator 75mm dia of vcb 630 amps 11 kv, supply only in replacement auxiliary switch 6no plus 6nc of vcb 630 amps 11 kv, supply only in replacement solenoid closing coil 3 or 110 v dc suitable for type v 207g vcb 630 a vmx breaker, supply fix and connect in replacement announciator suitable for 11 kv indoor control panel with necessary writing and testing on completion complete all as specified and directed, supply only in replacement charging motor for high tension 11 kv vcb panels 400 amps operated on 230 volts ac or 30 volts dc as per sample complete all as specified and directed by eic, supply only in replacement upper spout ht 11 kv vcb as per sample and fixing on panel all as required at site complete all as specified and directed, supply only in replacement male contact made of tinned copper vcb 11 kv made of brass as per sample and fixing testing all as required and directed at site complete all as specified and directed, s and f in replacement resin or epoxy coated air cooled high tension current transformer of dual ratio of 200 to 100 or 5amps 10va burden out put accuracy clas 0 point 5 suitable for rated as per atc, s and f in replacement over current earth fault relay having auxiliary voltage 24 to 110 volts plus 15 percent ac or dc complete all as specified and directed, s and f in replacement panel lighting lamp with holder with on or off toggle switch complete all as specified and directed, s and f in replacement bakelite hrc fuses in control or vcb panels complete all as specified and directed, s and f in replacement breaker control switch suitable for 11 kv control panel and outdoor vcbs complete all as specified and directed incl taking down old complete all as specified and directed, s and f in replacement digital multifunctional meter as per existing or as approved by the ge complete all as specified and directed, s and f in replacement selector switch for various type of control panels as per existing complete all as specified and directed, s and f in replacement switch air break gang operated god switch outdoor type ht 11 kv triple poles 200 amps with fixed contacts of phosphorus bronze and moving contacts of copper as per atc, s and f in replacement mild steel cross arms bracing supports clamps and back plates fabricated from structural steel section incl nuts bolts washers bending cold or hot drilling holes as per atc, excavation in trenches n exc 1 point 5m in depth and not exc 1 point 5m wide for laying of ug cable or pole etc and getting out incl forming bottom surface to required level and gradient as per atc, returning filling in excavated soil incl spreading leveling watering and well ramming in layers not exc 25cm thick complete all as specified, removing excavated material or soil to a distance n exc 50m and where directed at a level n exc 1 point 5 above the starting point complete all as specified and as directed by engr in charge, m and l for sand cushioning dry in trenches or ducts for protection of ug cables below above and around the ug cable laid in trenches of 23 cm spread thickness as per atc, plain cement concrete 1 is to 4 is to 8 type d 2using 40mm graded stone aggregate as in foundation of poles etc all as specified, plain cement concrete 1 is to 2 is to 4 type b 1 using 20mm graded stone aggregate for pole coping etc all as specified, plain cement concrete 1 is to 3 is to 6 type c 2 using 40mm graded stone aggregate as in foundation of pole etc all as specified, m and l in replacement for earthing complete with galvanized steel plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2 point 25 meters deep as per atc, transporting faulty or defective transformer rating upto 160 kva ratio 11 kv 0 point 433 or 0 point 415 kv to contractor workshop from ramgarh premises as per atc, m and l for centrifusing filteratin or dehydration of transformer oil incl filter action using automatic centrifusing machine incl armging elect supply for operation of machine to achieve as per atc, m and l for painting of distribution transformer of capacity upto 63 kva to 160 kva with two coats of smoke synthetic enamel paint colour or shed decided by ge externally after necessary as per atc, repair or overhauling to 11kv ht control panels complete in and incl the following repair works as per atc, m and l cable route indicator duly engraved with lt cable 1100v on cast iron round plate 150mm dia with provision of 500 mm long min single leg or stand of flat iron 50 x 6mm welded as per atc in jaisalmer, rajasthan,. Reference number 17098306. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.