tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore

Latest Tender Detail from indian army for the tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore in alwar, rajasthan,. Reference number 16813648. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

Description :
total quantity = 566 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc)
Description :
total quantity = 566 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc)

Get Complete Tender Documents to Participate

Tender NoticeBOQEligibilityEMD DetailsImportant Dates
We take all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Browse GeM Portal Tenders

This Government Tender has been Published  by Indian Army for work related to burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts in Alwar, Rajasthan. The Tender work is tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore, bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Indian Army usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Alwar , Rajasthan tender on a single page. Businesses involved in burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore from Alwar, Rajasthan may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Indian Army in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , electric ceiling fan (v4) isi marked to is 374 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , sheet metal enclosure double door , main wiring , metal clad plug and socket spn closure , excavating , returning filling , removal of excavated , brick work , dry sand and punning for cushoning , earthing , gi pipe, electric item and fixing, supply and fixing sheet metal enclosures double door type , suitable for fixing mcb, tpn with 200 amps rated bus bar , 4 way. 415 volts with inbuilt mccb 4 pole 32amp,16 ka complete all as specified and directed, s and f sub main wiring passing through and including concealed steel conduit pipe of 20 mm dia 1100 volts grade with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with pvc flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to is 694 or 1990 including cutting chasis and making good to wall surface all as specified and directed . note, two runs of cable with one run of earth wire and one run of pvc coundit should measured as one length, supply and fix metal clad plug and socket sp n enclosure with 2 pole and earth metal plug and socket complete with 20 amp mcb sp complete., excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 sqm on plan and getting out in soft or oose soil., returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft or loose soil., removal of excavated soil or material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified., m and l for brick work with fly ash bricks as per is-1375 or 1993 burnt clay fly ash building bricks, old size bricks with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent bricks not exc 10 mm over ug cable for protection and complete all as specified and directed., m and l for dry sand and punning for cushioning to under ground cable all as directed. note, for the purpose of payment only punned thickness shall be measured., material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0 mm thick burried directly in ground ,earth pit not less than 2.25 m deep below ground level with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of gi nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate no 3 of ssr part-i and connection to main switch board,test point,panel,equipment and testing on completion including excavation and earth work is as scope of work ., m and l for gi pipe light grade for protection of lt cable fixed to walls,poles and road crossing including clamps complete of 40 mm bore issued by Indian Army for burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts related work in Alwar, Rajasthan? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts parameters and guide you on how to coordinate efficiently with the procurement team of Indian Army

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Indian Army.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore in Rajasthan.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Alwar.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Indian Army

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts contracts, companies must prepare their core compliance documents. Vendors operating across Rajasthan must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality burnt clay fly ash building bricks,miniature circuit breakers,cable copper conductor,split air conditioner,electric ceiling fan,steel conduit pipe,pvc flexible cable,under ground cable,miniature circuit,circuit breakers,copper conductor,air conditioner,metal enclosure,sub main wiring,flexible cable,electric item,steel conduit,conduit pipe,cable copper,wall surface,switch board,ceiling fan,sheet metal,earth plate,main switch,xlpe cable,brick work,earth wire,earth work,ug cable,lt cable,gi pipe,bus bar,gi nuts,bricks,bolts solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Alwar region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore by Indian Army

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore within the Rajasthan jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for Tender For Split Air Conditioner, Wall Mount Type (v3) Isi Marked To Is 1391 (part 2) (q2) , Electric Ceiling Fan (v4) Isi Marked To Is 374 (q2) , Xlpe Cable For Working Voltage Up To And Including 1.1 Kv Marked To Is 7098 (part 1) (q2) , Miniature Circuit Breakers (mcb) For Ac Operation Marked To Is/iec 60898 (part 1) (q2) , Sheet Metal Enclosure Double Door , Main Wiring , Metal Clad Plug And Socket Spn Closure , Excavating , Returning Filling , Removal Of Excavated , Brick Work , Dry Sand And Punning For Cushoning , Earthing , Gi Pipe, Electric Item And Fixing, Supply And Fixing Sheet Metal Enclosures Double Door Type , Suitable For Fixing Mcb, Tpn With 200 Amps Rated Bus Bar , 4 Way. 415 Volts With Inbuilt Mccb 4 Pole 32amp,16 Ka Complete All As Specified And Directed, S And F Sub Main Wiring Passing Through And Including Concealed Steel Conduit Pipe Of 20 Mm Dia 1100 Volts Grade With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm And Continuous Earth With Pvc Flexible Cable Copper Conductor Unsheathed Multistranded Single Core Of Size 4 Sqmm Of Green Colour Confirming To Is 694 Or 1990 Including Cutting Chasis And Making Good To Wall Surface All As Specified And Directed . Note, Two Runs Of Cable With One Run Of Earth Wire And One Run Of Pvc Coundit Should Measured As One Length, Supply And Fix Metal Clad Plug And Socket Sp N Enclosure With 2 Pole And Earth Metal Plug And Socket Complete With 20 Amp Mcb Sp Complete., Excavating In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre In Depth For Foundation Or For Shafts, Walls, Manholes, Laying Of Cables, Pipes Etc Not Exc 10 Sqm On Plan And Getting Out In Soft Or Oose Soil., Returning, Filling In, Including Spreading, Leveling Watering And Well Ramming In Layers Not Exc 25 Cm Thick In Soft Or Loose Soil., Removal Of Excavated Soil Or Material To A Distance Not Exc 50 Metre And Depositing Where Directed At A Level Not Exc 1.50 Metre Above The Starting Point Complete All As Specified., M And L For Brick Work With Fly Ash Bricks As Per Is-1375 Or 1993 Burnt Clay Fly Ash Building Bricks, Old Size Bricks With Width Equal To The Length Of The Brick Laid Dry And Flat Abutted With Each Other With Gap Between Adjacent Bricks Not Exc 10 Mm Over Ug Cable For Protection And Complete All As Specified And Directed., M And L For Dry Sand And Punning For Cushioning To Under Ground Cable All As Directed. Note, For The Purpose Of Payment Only Punned Thickness Shall Be Measured., Material And Labour For Earthing Complete With Galvanized Steel Earth Plate Electrode 60cmx60cmx6.0 Mm Thick Burried Directly In Ground ,earth Pit Not Less Than 2.25 M Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 M Deep Below Normal Ground Level And Connected To And Including Galvanized Iron Earth Wire 4 Mm Dia By Means Of Gi Nuts, Bolts, Check Nuts, Washers Thimbles, Etc As Shown In Electrical Plate No 3 Of Ssr Part-i And Connection To Main Switch Board,test Point,panel,equipment And Testing On Completion Including Excavation And Earth Work Is As Scope Of Work ., M And L For Gi Pipe Light Grade For Protection Of Lt Cable Fixed To Walls,poles And Road Crossing Including Clamps Complete Of 40 Mm Bore are available inside the detailed notification files. Bidders planning to target this contract in Alwar should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Get Expert Tender Bidding Support

Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.

Call Our Expert: +91 7069661818
Your Information Is 100% Secure & Confidential