Latest Tender Detail from indian army for the tender for mandl for cable in trenches or passing through pipe xlpe insulated area 10 sqmm 4 core , all as per item ser no. 1 above but of size 16 sqmm 4 core. , all as per item ser no. 1 above but of size 25 sqmm 3.5 core. , all as per item ser no. 1 above but of size 50 sqmm 3.5 core. , all as per item ser no. 1 above but of size 70 sqmm 3.5 core. , all as per item ser no. 1 above but of size 95 sqmm 3.5 core. , all as per item ser no. 1 above but of size 120 sqmm 3.5 core. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches of 230mm , m and l for fly ash bricks locally available laid dry width wise across the line of cable , s and f galvanised iron pipe 80mm bore dia light grade for protection of ug cable , s and f galvanised iron pipe 50mm bore dia light grade for protection of ug cable , s and f hdpe dwc double walled corrugated of diameter 40 mm including disconnection and connection , s and f hdpe dwc double walled corrugated of diameter 63 mm including disconnection and connection of cable , m and l for horizontal boring for passing protection pipe up to 80mm bore dia under road foot path not exc. 10.00 mtr , mandl for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , supply commissioning and testing outdoor type lt distribution panel double door type weather proof cpri , supply commissioning and testing outdoor type lt distribution panel double door type weather proof cpri approved , insulation tester (q3), mandl for cable in trenches or passing through pipe, xlpe insulated, heavy duty, galvanised steel strip or wire armoured electric lt cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed., all as per item ser no. 1 above but of size 16 sqmm 4 core., all as per item ser no. 1 above but of size 25 sqmm 3.5 core., all as per item ser no. 1 above but of size 50 sqmm 3.5 core., all as per item ser no. 1 above but of size 70 sqmm 3.5 core., all as per item ser no. 1 above but of size 95 sqmm 3.5 core., all as per item ser no. 1 above but of size 120 sqmm 3.5 core., excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil, complete all as specified and as directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed., removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil, complete all as specified and as directed., mandl sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230mm spread thickness and consolidated punned upto 180mm thickness, complete all as specified and as directed. note for the purpose of payment, punned thickness of sand cushioning only shall be measured and paid ., mandl for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable, complete all as specified and as directed., sandf galvanised iron pipe 80mm bore dia light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., sandf galvanised iron pipe 50mm bore dia light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., s and f hdpe dwc double walled corrugated of diameter 40 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., s and f hdpe dwc double walled corrugated of diameter 63 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., mandl for horizontal boring for passing protection pipe up to 80mm bore dia , under road /foot path, not exc. 10.00 mtr in a single length, complete all as specified and as directed. note pipe to be measured separately., mandl for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode , buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/welding or steel all as shown in electrical plate no 3 in ssr part i of 2009 connected to earthing test point all as specified complete with excavation and earth work, pcc pit with 50mm thick rcc cover/ci /ms cover having suitable handle 10mm ms rod 20mm dia gi medium grade watering pipe with gi funnel with wire mesh 40mm bore gi pipe medium grade isi marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by engineer-in-charge., supply, commissioning and testing outdoor type lt distribution panel, double door type, weather proof, cpri approved, seven tank treatment powder coated factory made lt panel board, totally enclosed, dust and vermin proof openable from front and back side, canopy headed,cable alley at both sides, connected with suitable size ms angle iron frame, for main distribution panel, fabricated with crca sheet 3.15mm thick sheet incluing ip - 54 protection, installed on concrete base made of pcc 1 3 6 type c1 using 20mm graded aggregate ,including self locking arragement including taking down old unserviceable one. bus bar chamber a sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity tpandn solid aluminium bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable pvc sleevings. the bars shall be colour coded at required intervals for identification - set of 4, 1 no. incomer a mccb 630 amps, 415 volt, 50 ka breaking capacity 4 pole duly connected to bus bar - 01 nos. outgoing feeders a mccb 200 amps, 415 volt, 35/36 ka breaking capacity 4 pole duly connected to bus bar - 04 nos. c mccb 63 amps, 415 volt, 16 ka breaking capacity 4 pole duly connected to bus bar - 02 nos. indicating devices a led indicating lamps for main supply indicating r, y b - set of 3. b digital voltmeter 96mmx96mm 0-500 volt with selector switch of 10amps -1no. c current transformer having ratio 125/5 - set of 3. d digital ammeter 0 to 500 amps with selector switch - 1 no., supply, commissioning and testing outdoor type lt distribution panel, double door type, weather proof, cpri approved, seven tank treatment powder coated factory made lt panel board, totally enclosed, dust and vermin proof openable from front and back side, canopy headed,cable alley at both sides, connected with suitable size ms angle iron frame, for main distribution panel, fabricated with crca sheet 3.15mm thick sheet incluing ip - 54 protection, installed on concrete base made of pcc 1 3 6 type c1 using 20mm graded aggregate ,including self locking arragement including taking down old unserviceable one. bus bar chamber a sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity tpandn solid aluminium bus bars, rated 400 amps supported at required intervals sleeved with heat shrinkable pvc sleevings. the bars shall be colour coded at required intervals for identification - set of 4, 1 no. incomer a mccb 250 amps, 415 volt, 35/36 ka breaking capacity 4 pole duly connected to bus bar - 01 nos. outgoing feeders a mccb 100 amps, 415 volt, 16 ka breaking capacity 4 pole duly connected to bus bar - 04 nos. a mccb 40 amps, 415 volt, 16 ka breaking capacity 4 pole duly connected to bus bar - 02 nos. indicating devices a led indicating lamps for main supply indicating r, y b - set of 3. b digital voltmeter 96mmx96mm 0-500 volt with selector switch of 10amps -1no. c current transformer having ratio 250/5 - set of 3. in bardhaman, west bengal,. Reference number 16767567. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!
Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.