tender for electrification work of lighthouse tower at gopnath lighthouse and dgps station staircase wiring , 2 module , 4 module , 6 module , 12 module , 5 or 6 a switch , 15 or 16 a switch , 3 pin 5 or 6 a socket outlet , 6 pin 15 or 16 a socket outlet , brass holder , blanking plate , installation of bulkhead , installation of tubelight , pvc conduit 20 mm , copper wire 3 x 1.5 sq mm , copper wire 3 x 2.5 sq mm , copper wire 3 x 4 sq mm , 3c and 6 sq mm copper xlpe armoured cable , 3c and 6 sq mm copper xlpe unarmoured cable , cable laying work , 6 way double door mcb board , 4 way 4 and 12 double door mcb board , single pole 20 a mcb , double pole 32 a 04 nos , double pole 40 a mcb , double pole 63 a mcb , led tube light , bulkhead , upvc cable tray , wall fan , labour charges , led circular or squre light , plate earthing work , earthing copper strip 25 x 3 mm , 16 sq mm 1 core copper cable , earth station, electrification work of lighthouse tower at gopnath lighthouse and dgps station, wiring for twin control light point with 1.5 sq. mm frls or hffr pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit 2 way modular switch modular plate suitable gi or pvc box and earthing the point with 1.5 sq.mm frls or hffr pvc insulated copper conductor single core cable etc as required, supplying and fixing following 2 module gi box or surface plastic box alongwith modular base and cover plate for modular switches in recess etc as required, supplying and fixing following 4 module gi box or surface plastic box alongwith modular base and cover plate for modular switches in recess etc as required, supplying and fixing following 6 module gi box or surface plastic box alongwith modular base and cover plate for modular switches in recess etc as required, supplying and fixing following 12 module gi box or surface plastic box alongwith modular base and cover plate for modular switches in recess etc as required, supplying and fixing following modular switch or socket on the existing modular plate and switch box including connections but excluding modular plate etc as required, supplying and fixing brass batten or angle holder including connection etc as required, supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required, installation testing commissioning of wall bracket or ceiling fitting of all sizes and shapes containing upto two gls or cfl or led lamp per fitting complete with all accessories including connections etc as required for bulkhead fitting must by carried out on wooden patia, installation testing commissioning of pre-wired fluorescent fitting or compact fluorescent fitting of all types complete with all accessories and tube or lamp etc.directly on ceiling or wall including connections with 1.5 sq.mm frls or hffr pvc insulated copper conductor single core cable and earthing etcas required., supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as required., supplying and drawing 3 x 1.5 sqmm means phase nuetral and earth wire of frls or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required, supplying and drawing of 3 x 2.5 sq mm means phase nuetral and earth wire of frls or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required, supplying and drawing of 3 x 4 sqmm means phase nuetral and earth wire of frls or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required, supply of power cable 3c and 6 sqmm 1.1 kv grade frls multistranded copper conductor xlpe armoured cable finolex polycab or havells make from aton panel to tower base for main light nais and tower light, supply of power cable 3c and 6 sqmm 1.1 kv grade frls multistranded copper conductor xlpe unarmoured cable. finolex polycab or havells make from tower base mcb board to tower service room for main light nais and tower light, laying of one number pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as required., supplying and fixing following way single pole and neutral sheet steel mcb distribution board 240 v on surface or recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted including earthing etc.as required but without mcb or rccb or isolator, supplying and fixing mcb distribution board 415 v on surface or recess complete including earthing etc., supplying and fixing 5 a to 32 a rating 240 or 415 v 10 ka c curve mcb suitable for inductive load of following poles in the existing mcb db complete, supplying and fixing 5 a to 32 a rating 240 or 415 v 10 ka c curve miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections,testing and commissioning etc.as required, supplying and fixing 40 a rating double pole 240 or 415 v 10 ka c curve miniature circuit breaker suitable for inductive load in the existing mcb db complete with connections,testing and commissioning etc.as required, supplying and fixing 63 a rating double pole 240 or 415 v 10 ka c curve,miniature circuit breaker suitable for inductive load in the existing mcb db complete with connections testing and commissioning etc.as required, supply of led tube light fitting 22 w and 230 v 4 ft in white colour 2200 lumen etc.any reputed brand., supply of aluminum bulkhead light ip 65 protection with 10 watt 230 v crompton or philips or bajaj, supply of 2 mtr length cable trunking upvc tray 100 x 50 mm,any reputed brand, supply of copper winding 230 v 1 ph wall mounted fan sweep size 400 mm 3 nos blades any reputed brand, labour charges for dismantaling & removing old pvc cable tray screw and cables from tower base to top of service room and fitting new cable trunking pvc tray 100 mm x 50 mm by using s.s. and brass screw and washer. the distance between two srew must be 1 feet and after fitting cable tray laying of old and new cable in cable trunking by using heavy duty cable tie as per instructed complete etc with tool and plant., supplying led indoor fittings with leds of wattage 0.2 watt to 0.5 watt assembled on single mcpcb with housing as a heat sink conforming ip 65 protection 20 to 40 watts surge 4 kv ip 65 and above rating size 300 mm to 450 mm, earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 meter long etc. with charcoal coke and salt as required, supply of 25x3 mm copper strip for service room equipment earthing, supply of 16 sqmm 1 core pvc insulated copper flexible frls cable green colour, supplying and fixing of 6 way and 4 way earth station at tower base and service room for earthing connection to all equipment