tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge.

Latest Tender Detail from indian army for the tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge. in bardhaman, west bengal,. Reference number 16121823. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:16121823
Tender ID:GEM/2026/B/7699424
Tender Agency:indian army
City:bardhaman
State:west bengal
Tender Related Keywords :
Description :
total quantity = 5988 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem annual turnover,additional doc 1 (requested in atc),compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation
T18 Ref No:16121823Tender Value:Refer Document
Tender ID:GEM/2026/B/7699424Tender EMD:Refer Document
Tender Agency:indian armyTender Fee:Refer Document
City:bardhamanPublished Date:Jul 06, 2026
State:west bengalDue Date:Jul 17, 2026
Tender Related Keywords :wrecking crow bar or claw bar, porcelain ceramic insulator, supply and installation, hexagonal head screws, lightening conductor, testing instrument, gi earthing strip, ceramic insulator, earth electrodes, aluminium strip, earthing system, terminal block, earthing strip, aluminium rod, earthing pits, copper strip, earthing pit, earth tester, earth strip, earth plate, copper rod, iron strip, earth work, cover slab, good earth, hdpe pipe, nut bolt, claw bar, gi pipe, tmt bar, bricks, boltsTender Opening Date:Jul 17, 2026
Description :total quantity = 5988 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem annual turnover,additional doc 1 (requested in atc),compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation

Get Complete Tender Documents to Participate

Tender NoticeBOQEligibilityEMD DetailsImportant Dates
We take all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Browse GeM Portal Tenders

This Government Tender has been Published  by Indian Army for work related to wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts in Bardhaman, West Bengal. The Tender work is tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge.. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge., bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Indian Army usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Bardhaman , West Bengal tender on a single page. Businesses involved in wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge. from Bardhaman, West Bengal may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Indian Army in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for dismantling and taking down of old unserviceable air termination rod of any type and any size complete. , supply and fix air termination single pointed aluminium rod 12mm dia and 300mm long fixed on aluminium strip etc. , supply and fix air termination single pointed copper rod 12mm dia and 300mm long fixed on aluminium strip etc. , dismantling and taking down of old unserviceable test point terminal block of any type and any size complete. , supply and fix test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled etc. , dismantling and taking down of old unserviceable earthing lead strips of any type and any size complete. , materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground etc. , mandl for brazing gas welding for existing copper gi earthing strip joints by removing nuts and bolts etc. , dismantling and taking down of old unserviceable gi hdpe pipe of any type and any size complete. , supply and fixing gi tubing 40 mm bore light grade with all fittings laid in trenches or fixed to wall etc. , mand l for making holes in bricks stones pcc block wall masonary in building for passing of earthing strip etc. , supply and fix high density polythelene pipes hdpe 40mm dia for insulation of earth strip from building etc. , supply and fix white porcelain ceramic insulator with nut bolt and washers for fixing earthing strip etc. , mandl for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed. , dismantling and taking down of old unserviceable earthing of any type complete. , materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground etc. , supply and installation of advance encasulated compound based cpri tested maintenance free pipe in pipe technology etc. , materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground etc. , dismantling and taking down of old unserviceable earthing pits of any type complete. , supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing etc. , wrecking crow bar or claw bar as per is 706 (q3), dismantling and taking down of old unserviceable air termination rod of any type and any size complete., supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground, complete all as directed by engineer in charge., supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long fixed on aluminium strip for earth conductivity to ground , complete all as directed by engineer in charge., dismantling and taking down of old unserviceable test point terminal block of any type & any size complete., supply and fix test point terminal block made of gun metal or phosphorous bronze, size 75 x 75 x 25 mm , drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screws including ms box 2 mm thick of suitable size for protection of test point terminal , complete all as specified and as directed., dismantling and taking down of old unserviceable earthing lead/strips of any type & any size complete., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulators, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25x4 galvanised iron strip using porcelain clit/post insulators including taking out old u/s galvanised iron strip, complete all as specified and as directed., materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 x 3 mm alumunium strip using porcelain clit/post insulators including taking out old u/s alumunium strip, complete all as specified and as directed., m&l for brazing /gas welding for existing copper/gi earthing strip joints by removing nuts and bolts complete all as specified and directed., dismantling and taking down of old unserviceable gi/hdpe pipe of any type & any size complete., supply and fixing gi tubing, 40 mm bore, light grade with all fittings laid in trenches or fixed to wall including taking down of existing pipes and removal from site, complete all as specified and as directed., m& l for making holes in bricks/stones/pcc block wall masonary in building for passing of earthing strip including making good to match existing surface complete all as specified and directed., supply and fix high density polythelene pipes (hdpe) 40mm dia for insulation of earth strip from building at entry points incl taking out old u/s pipes, complete all as specified and as directed., supply and fix white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof incl taking out old unserviceable porcelain ceramic insulator ,complete all as specified and as directed., m&l for pcc 1 3 6 type c 1 using 20mm graded aggregate for pcc for mounting gi pipe of lightening conductor complete all as specified and directed., dismantling and taking down of old unserviceable earthing of any type complete., materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 25x4 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately, materials and labour for earthing with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 m including galvanised iron strip 32x6 mm bolted and reverted to earth plate at one end and connected to continuous gi strip encased in and including 40 mm dia gi light grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways including taking out old unserviceable earthing, complete all as specified and as directed. note. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of gi strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately., supply & installation of advance encasulated compound based cpri tested maintenance free,pipe in pipe technology upgrated (zinc & alloy coated),zinc coated (80 100) micron with pure zinc (99.9%) & alloy coating (200 250) microns.earthing sysrem confirming is 3043.the outer & inner pipe should be 76.2 mm & 41.9 mm dia.3mtrs lenght,zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal.the annular space between the pipes being filled up with compact fill(cf)(crystalline conductive compound).the job includes digging the pits and refilling the same by baron electrodite back fill compound(ground enhancer),the bfc should be eco friendly it should not contain environmentally hazardous material /metal having rohs certification from nabl accredited lab.the earth pit should be provided with frp or epcc earth pit cover for protection and safe guard of terminals.in areas where soil condition is bad,good earth i.e.black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with bfc 2 4 bags electrodite bfc for installation of earth electrodes.as the earth electrodes is the main component of the earthing system which is in direct contact with the ground and thus provides a etc. (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost., materials and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less rhan 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 meter below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returing filling in and removal of surplus soil upto 50 mtr including copper strip 20x3 mm bolted and reverted to earth plate at one end and connected to continuous copper strip encased in and including 40 mm dia gi medium grade protection pipe, 20 mm dia medium grade watering pipe with all fittings from top edge of earth plate upto 2400 mm above ground level fixed and including 25x 3 mm gi clamp bolts nuts and washer, funnel, wiremesh, pcc (1 3 6) type c1 earthing pit, 75 mm thick rcc cover slab reinforced with 8 mm dia tmt bar 100 c/c both ways completeall as specified and as directed including testing on completion taking out old unserviceable earthing complete. note (i) if the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) testing to be carried out by the contractor, entered in the eath testing register, prepared and to be maintained by the contractor & submited to department. (iii) t&p and testing instrument(earth tester) to be provided by the contractor at own cost. (iv) quoted rate shall be deemed to include the cost of copper strip upto a distance of 7.5 metres from the earth plate. strip required beyond the length shall be measured and paid separately. (v) the earthing pit should be provided with proper earth pit and pit cover., dismantling and taking down of old unserviceable earthing pits of any type complete., supply and fix in repair s frp earth pit cover heavy duty of minimum size 13 inch for earthing chamber, complete all as specified and as directed by engr in charge. issued by Indian Army for wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts related work in Bardhaman, West Bengal? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts, Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts parameters and guide you on how to coordinate efficiently with the procurement team of Indian Army

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge. . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Indian Army.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge. in West Bengal.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge.. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Bardhaman.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Indian Army

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts contracts, companies must prepare their core compliance documents. Vendors operating across West Bengal must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality wrecking crow bar or claw bar,porcelain ceramic insulator,supply and installation,hexagonal head screws,lightening conductor,testing instrument,gi earthing strip,ceramic insulator,earth electrodes,aluminium strip,earthing system,terminal block,earthing strip,aluminium rod,earthing pits,copper strip,earthing pit,earth tester,earth strip,earth plate,copper rod,iron strip,earth work,cover slab,good earth,hdpe pipe,nut bolt,claw bar,gi pipe,tmt bar,bricks,bolts solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Bardhaman region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge. by Indian Army

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge. within the West Bengal jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for Tender For Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete. , Supply And Fix Air Termination Single Pointed Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Supply And Fix Air Termination Single Pointed Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip Etc. , Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type And Any Size Complete. , Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze Size 75 X 75 X 25 Mm Drilled Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Lead Strips Of Any Type And Any Size Complete. , Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Etc. , Mandl For Brazing Gas Welding For Existing Copper Gi Earthing Strip Joints By Removing Nuts And Bolts Etc. , Dismantling And Taking Down Of Old Unserviceable Gi Hdpe Pipe Of Any Type And Any Size Complete. , Supply And Fixing Gi Tubing 40 Mm Bore Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Etc. , Mand L For Making Holes In Bricks Stones Pcc Block Wall Masonary In Building For Passing Of Earthing Strip Etc. , Supply And Fix High Density Polythelene Pipes Hdpe 40mm Dia For Insulation Of Earth Strip From Building Etc. , Supply And Fix White Porcelain Ceramic Insulator With Nut Bolt And Washers For Fixing Earthing Strip Etc. , Mandl For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed. , Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete. , Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground Etc. , Supply And Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free Pipe In Pipe Technology Etc. , Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground Etc. , Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete. , Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Etc. , Wrecking Crow Bar Or Claw Bar As Per Is 706 (q3), Dismantling And Taking Down Of Old Unserviceable Air Termination Rod Of Any Type And Any Size Complete., Supply And Fix Air Termination, Single Pointed, Aluminium Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground, Complete All As Directed By Engineer In Charge., Supply And Fix Air Termination, Single Pointed, Copper Rod 12mm Dia And 300mm Long Fixed On Aluminium Strip For Earth Conductivity To Ground , Complete All As Directed By Engineer In Charge., Dismantling And Taking Down Of Old Unserviceable Test Point Terminal Block Of Any Type & Any Size Complete., Supply And Fix Test Point Terminal Block Made Of Gun Metal Or Phosphorous Bronze, Size 75 X 75 X 25 Mm , Drilled And Screwed Including 3 Nos. 8 Mm Dia. 25 Mm Long Hexagonal Head Screws Including Ms Box 2 Mm Thick Of Suitable Size For Protection Of Test Point Terminal , Complete All As Specified And As Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Lead/strips Of Any Type & Any Size Complete., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 20x3 Copper Strip Using Porcelain Clit/post Insulators, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 32x6 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25x4 Galvanised Iron Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Galvanised Iron Strip, Complete All As Specified And As Directed., Materials And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required For 25 X 3 Mm Alumunium Strip Using Porcelain Clit/post Insulators Including Taking Out Old U/s Alumunium Strip, Complete All As Specified And As Directed., M&l For Brazing /gas Welding For Existing Copper/gi Earthing Strip Joints By Removing Nuts And Bolts Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Gi/hdpe Pipe Of Any Type & Any Size Complete., Supply And Fixing Gi Tubing, 40 Mm Bore, Light Grade With All Fittings Laid In Trenches Or Fixed To Wall Including Taking Down Of Existing Pipes And Removal From Site, Complete All As Specified And As Directed., M& L For Making Holes In Bricks/stones/pcc Block Wall Masonary In Building For Passing Of Earthing Strip Including Making Good To Match Existing Surface Complete All As Specified And Directed., Supply And Fix High Density Polythelene Pipes (hdpe) 40mm Dia For Insulation Of Earth Strip From Building At Entry Points Incl Taking Out Old U/s Pipes, Complete All As Specified And As Directed., Supply And Fix White Porcelain Ceramic Insulator With Nut, Bolt And Washers For Fixing Earthing Strip On Wall/ceiling/roof Incl Taking Out Old Unserviceable Porcelain Ceramic Insulator ,complete All As Specified And As Directed., M&l For Pcc 1 3 6 Type C 1 Using 20mm Graded Aggregate For Pcc For Mounting Gi Pipe Of Lightening Conductor Complete All As Specified And Directed., Dismantling And Taking Down Of Old Unserviceable Earthing Of Any Type Complete., Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 25x4 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately, Materials And Labour For Earthing With Galvanised Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 M Including Galvanised Iron Strip 32x6 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Gi Strip Encased In And Including 40 Mm Dia Gi Light Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Including Taking Out Old Unserviceable Earthing, Complete All As Specified And As Directed. Note. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Gi Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately., Supply & Installation Of Advance Encasulated Compound Based Cpri Tested Maintenance Free,pipe In Pipe Technology Upgrated (zinc & Alloy Coated),zinc Coated (80 100) Micron With Pure Zinc (99.9%) & Alloy Coating (200 250) Microns.earthing Sysrem Confirming Is 3043.the Outer & Inner Pipe Should Be 76.2 Mm & 41.9 Mm Dia.3mtrs Lenght,zinc Coated With Additional Special Alloy Coating 300mm On The Topside For Additional Protection Of The Terminal.the Annular Space Between The Pipes Being Filled Up With Compact Fill(cf)(crystalline Conductive Compound).the Job Includes Digging The Pits And Refilling The Same By Baron Electrodite Back Fill Compound(ground Enhancer),the Bfc Should Be Eco Friendly It Should Not Contain Environmentally Hazardous Material /metal Having Rohs Certification From Nabl Accredited Lab.the Earth Pit Should Be Provided With Frp Or Epcc Earth Pit Cover For Protection And Safe Guard Of Terminals.in Areas Where Soil Condition Is Bad,good Earth I.e.black Cotton Or Moistures Normal Soil Is To Be Arranged To Fill The Excavated Pits By Mixing The Arranged Soil With Bfc 2 4 Bags Electrodite Bfc For Installation Of Earth Electrodes.as The Earth Electrodes Is The Main Component Of The Earthing System Which Is In Direct Contact With The Ground And Thus Provides A Etc. (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost., Materials And Labour For Earthing With Copper Earth Plate Electrode 600 X 600 X 3.15 Mm Thick Burried Directly In Ground (earth Pit Not Less Rhan 2.25 M Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level, The Earth Plate Surrounded By Alternative Layer Of Charcoal Dust And Salt With Thickness Of 150 Mm To A Packed Thickness Of 150 Mm On All Sides With And Including Necessary Excavation Earth Work Returing Filling In And Removal Of Surplus Soil Upto 50 Mtr Including Copper Strip 20x3 Mm Bolted And Reverted To Earth Plate At One End And Connected To Continuous Copper Strip Encased In And Including 40 Mm Dia Gi Medium Grade Protection Pipe, 20 Mm Dia Medium Grade Watering Pipe With All Fittings From Top Edge Of Earth Plate Upto 2400 Mm Above Ground Level Fixed And Including 25x 3 Mm Gi Clamp Bolts Nuts And Washer, Funnel, Wiremesh, Pcc (1 3 6) Type C1 Earthing Pit, 75 Mm Thick Rcc Cover Slab Reinforced With 8 Mm Dia Tmt Bar 100 C/c Both Ways Completeall As Specified And As Directed Including Testing On Completion Taking Out Old Unserviceable Earthing Complete. Note (i) If The Desired Earth Resistance Is Not Found, Earthing Shall Be Redone By The Contractor At No Extra Cost To The Department. (ii) Testing To Be Carried Out By The Contractor, Entered In The Eath Testing Register, Prepared And To Be Maintained By The Contractor & Submited To Department. (iii) T&p And Testing Instrument(earth Tester) To Be Provided By The Contractor At Own Cost. (iv) Quoted Rate Shall Be Deemed To Include The Cost Of Copper Strip Upto A Distance Of 7.5 Metres From The Earth Plate. Strip Required Beyond The Length Shall Be Measured And Paid Separately. (v) The Earthing Pit Should Be Provided With Proper Earth Pit And Pit Cover., Dismantling And Taking Down Of Old Unserviceable Earthing Pits Of Any Type Complete., Supply And Fix In Repair S Frp Earth Pit Cover Heavy Duty Of Minimum Size 13 Inch For Earthing Chamber, Complete All As Specified And As Directed By Engr In Charge. are available inside the detailed notification files. Bidders planning to target this contract in Bardhaman should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Get Expert Tender Bidding Support

Looking For Complete Tender Bidding Consultancy? Our Technical Experts Will Help You Prepare And Submit Your Tender Successfully.

Call Our Expert: +91 7069661818
Your Information Is 100% Secure & Confidential