tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst

Latest Tender Detail from bharat sanchar nigam limited BSNL for the tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst in krishna, andhra pradesh,. Reference number 14928111. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:14928111
Tender ID:GEM/2026/B/7411832
Tender Agency:bharat sanchar nigam limited BSNL
City:krishna
State:andhra pradesh
Description :total quantity = 246 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),additional doc 4 (requested in atc),compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation
Tender Value:939458
Tender EMD:18789
Tender Fee:Refer Document
Published Date:Apr 04, 2026
Due Date:Apr 20, 2026
Tender Opening Date:Apr 20, 2026
T18 Ref No:14928111Tender Value:939458
Tender ID:GEM/2026/B/7411832Tender EMD:18789
Tender Agency:bharat sanchar nigam limited BSNLTender Fee:Refer Document
City:krishnaPublished Date:Apr 04, 2026
State:andhra pradeshDue Date:Apr 20, 2026
Tender Related Keywords :-Tender Opening Date:Apr 20, 2026
Description :total quantity = 246 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,oem annual turnover,additional doc 1 (requested in atc),additional doc 2 (requested in atc),additional doc 3 (requested in atc),additional doc 4 (requested in atc),compliance of boq specification and supporting document ----- evaluation method = total value wise evaluation
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

This Government Tender has been Published  by Bharat sanchar nigam limited BSNL for work related to in Krishna, Andhra pradesh. The Tender work is tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst. Tender18 Provide this type Government Tender Information on daily basis.


This tender invites eligible contractors, suppliers, manufacturers, consultants, Startups, Msmes, traders and service providers to submit bids for the specified project, supply, service, or work requirement.


Before applying, interested bidders should review the tender scope, eligibility criteria, estimated contract value, important dates, technical requirements, reqired docuent list for bidder and bid submission instructions as per provided in the official tender documents. 


This Verified Information Provide By Tender18 in this page so Bidder Can Easiy  Understanding tender  requirements and bidders can prepare a compliant and competitive tender proposal.

To participate in the tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst, bidders should first download and review all available tender documents. These documents generally include the Notice Inviting Tender (NIT), Bill of Quantities (BOQ), technical specifications, eligibility criteria, scope of work, and bid submission instructions.


Tender Governemnt Authorities like Bharat sanchar nigam limited BSNL usually publish these documents on their official eProcurement portals, departmental tender portals, the GeM Tender Portal, or other government procurement platforms or on newspapre. Finding and accessing the correct tender documents across multiple portals can sometimes be time-consuming for bidders. 


To make the process easier, Tender18 provides quick access to the available tender documents related to this Krishna , Andhra pradesh tender on a single page. Businesses involved in related products, services, or works can conveniently download the relevant documents and review the tender requirements without spending time searching across different procurement portals.

The tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst from Krishna, Andhra pradesh may be relevant for contractors, suppliers, vendors, manufacturers, consultants, service providers, startups, MSMEs, and other organizations involved in related products, services, or works. However, eligibility to participate depends on the qualification criteria specified by Bharat sanchar nigam limited BSNL in the official tender documents.

Before submitting a bid, interested applicants should carefully review the eligibility conditions, technical requirements, financial criteria, work experience requirements, annual turnover conditions, registrations, certifications, and any other supporting documents required by the tendering authority. The detailed qualification requirements and bidder eligibility criteria are available in the tender notice and related documents provided on this page. 

Ensuring compliance with all eligibility and qualification requirements before bid submission can help bidders avoid disqualification and improve their chances of successful participation in the tender process.

Tende18 provides comprehensive tender bidding services, including a complete tender summary along with a detailed analysis of the Tender Qualification and Eligibility Criteria.

Interested in participating in the tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst issued by Bharat sanchar nigam limited BSNL for related work in Krishna, Andhra pradesh? TENDER18 provides complete assistance to help businesses understand tender requirements, access tender documents, review eligibility criteria, qualification requirements, important dates, and bid submission guidelines associated with this tender.

Our Tender18 Expert Technical team can assist with vendor and GeM registration on the relevant departmental, eProcurement, GeM, or government tender portal, preparation of technical and financial bid documents, compliance with qualification criteria, document verification, and complete online tender submission support. Whether you are a contractor, supplier, manufacturer, consultant, startup, or MSME working in the field of , Tender18 can help simplify the tender participation process and support you throughout every stage of bidding for this tender. so that tender18 is one the top leading tender consultant in Inda.

1.

Whom should I contact if I have further queries about the Tender scope?

You can fill out the integrated inquiry form below on this detail page to share your company profile. Our consultancy desk will review your query regarding parameters and guide you on how to coordinate efficiently with the procurement team of Bharat sanchar nigam limited BSNL

2.

How can Tender18 assist my business in winning this government contract?

Tender18 provides end-to-end professional bidding support and documentation advisory for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst . Our senior analysts help you decode the complete project guidelines, manage accurate costing sheets, and complete error-free submissions on the official platform used by Bharat sanchar nigam limited BSNL.

3.

What are the main reasons for a technical tender rejection?

Most online bids face rejection during the initial evaluation round due to avoidable errors like uploading blurred document scans, submitting expired DSCs, or missing critical experience papers required for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst in Andhra pradesh.

4.

Can contractors located outside the local region participate in this bid?

Eligibility for outstation bidders depends entirely on the terms set inside the document for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst. While many public sector projects allow national competitive bidding, certain localized works require local offices or specific registration metrics in Krishna.

5.

Do I need an active GeM Portal registration to apply for this work?

If this procurement is routed through the central marketplace, an active GeM Seller ID is mandatory to supply items. Tender18 offers complete assistance for brand cataloging, profile creation, and vendor assessment required officially by Bharat sanchar nigam limited BSNL

6.

What are the primary legal documents required to submit a valid bid?

To register an eligible bid for these contracts, companies must prepare their core compliance documents. Vendors operating across Andhra pradesh must ensure they possess a valid GST registration, permanent account number (PAN), and active Class-3 Digital Signature Certificates.

7.

What products or services are required for this active work?

This public procurement cycle is specifically looking for qualified vendors and suppliers who can provide high-quality solutions. The operational execution, delivery, and deployment of these materials must be managed locally within the Krishna region.

8.

Where can I review the estimated cost or budget details for this Tender?

The estimated project cost and budget thresholds can be reviewed directly inside the tender document. Bidders can analyze these qualification files to check if their firm meets the financial capability criteria specified for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst by Bharat sanchar nigam limited BSNL

9.

How can I download the official BOQ file for this opportunity?

You can download the commercial Bill of Quantities (BOQ) spreadsheet directly using the secure link provided on this page. The BOQ file contains the item descriptions and rate filling forms officially validated for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst within the Andhra pradesh jurisdiction

10.

How can I find the submission closing date for this contract?

The official timeline and deadline details for tender for supply of 3 tr ductable inverter type aircooled split ac unit , installation testing and commissioning of 3 tr ductable type air cooled split ac unit , providing and laying of refrigerant pipes and other works , supplying and fixing of 25 mm dia of upvc pipe , providing and fixing of suspension round rods, 3 tr ductable ac units at e10b te bsnl kurnool, supply of 3 tr ductable inverter type aircooled split ac unit with scroll or rotary compressor single circuit refrigerant type with not less than 36000 btu per hr having eer of min 10 btu per watthour and static pressure of min 45 pascals with copper coils evaporator and condenser as per specification as required note rate shall be quoted inclusive of gst, installation testing & commissioning ict of 3 tr ductable type air cooled split ac unit as per specification including lifting and positioning of indoor and outdoor units pre-testing vaccumisation pressure testing with nitrogen supplying and charging of refrigerant gas supplying and laying of power supply cable on surface or recess from outdoor unit to the nearby existing supply terminal box as required rate shall be quoted inclusive of gst, providing and laying of refrigerant connection with copper tubes of suitable gauge and sizes as per manufacturer recommendation for both suction and liquid lines on existing tray/ wall / partition including supplying and fixing of all required accessories such as bends elbows couplings including brazing pressure testing providing and fixing suitable clamps supports and insulating the refrigerant lines with insulation hoses or with nitrile rubber sleeve wrapped with thermal tape etc including interconnection cabling between indoor to outdoor units complete as required.rate shall be quoted inclusive of gst, supplying and fixing of 25 mm dia of upvc pipe along with accessories on surface or recess including cutting the wall/partition and making good the same to drain condensate water etc complete as required rate shall be quoted inclusive of gst, providing and fixing of suitable size ms rods for suspending the indoor units with anchor bolts in ceiling i/c providing double nuts on each suspension rod and making good damages etc. complete as required rate shall be quoted inclusive of gst are available inside the detailed notification files. Bidders planning to target this contract in Krishna should check the official portal schedule early to complete their online technical and financial submission well before the closing hours.

Tender Inquiry