Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

5Results forPartition frame spares Tenders List

Latest Partition frame spares Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Partition frame spares tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Partition frame spares tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Partition frame spares Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Partition frame spares tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Partition frame spares Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Partition frame spares Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Partition frame spares Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Partition frame spares tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Partition frame spares Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Partition frame spares sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Partition frame spares tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Partition frame spares tenders.

Is EMD mandatory for all Partition frame spares tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Partition frame spares work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Partition frame spares tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Partition frame spares Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 15602540
Location : mumbai , maharashtra
Source : GEM Tenders

tender for 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp supply installation testing and commissioning , fp mcb 63 amp supply installation testing and commissioning , fp mcb 40 amp supply installation testing and commissioning , sp and n distribution board 12 way hvac idu , dp mcb 32 amp supply installation testing and commissioning , sp mcb 6 or 10 amp supply installation testing and commissioning , sfu 100a tpn at main switch board supply installation testing and commissioning , chemical earth electrode earthing arrangement supply installation testing and commissioning , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system, supply installation testing and commissioning of vrv type ac, supply and delivery of 14 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 20 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 24 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, installation testing and commissioning of 14 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 20 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 24 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, supply of 1.5 tr vrf 4 way cassette indoor unit with cooling capacity 12 kw and above power input 110 to 125 w airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature, supply of 4 tr vrf 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature as per specifications, installation testing and commissioning of 1.5 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, installation testing and commissioning of 4 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, supply of 3 tr split type direct expansion air conditioning system with 4 way ceiling mounted cassette indoor unit and matching air cooled outdoor unit hermetically sealed scroll compressor condenser and evaporator coil drain pump remote control suitable for 50 degree ambient, installation testing and commissioning of 3 tr split type cassette dx air conditioning system including mounting of indoor and outdoor units vibration isolation pads electrical termination control wiring drain piping nitrogen pressure testing vacuumization refrigerant charging and trial run, supply of centralized remote controller unit of same make as ac units for centralized control and monitoring of all connected vrf indoor and outdoor units complete with all accessories as recommended by manufacturer, installation testing and commissioning of centralized remote control unit for vrf system including all wiring connections configuration of connected indoor and outdoor units testing and commissioning complete as required, supply of 25.4 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 22.2 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 19 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 15.86 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 12.7 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 9.5 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, installation testing and commissioning including vacuumization and nitrogen testing of 25.4 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 22.2 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 19 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 15.86 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 12.7 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 9.5 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, supply of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer suitable for combination of indoor and outdoor machines for vrf system complete with all accessories, installation testing and commissioning of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer for vrf system complete with all accessories as required, supply and delivery of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, laying of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, supply of pvc condensate drain pipe of suitable size for ac indoor units with supports clamps and insulation as required complete with all accessories as per instructions, installation of pvc condensate drain piping for ac indoor units with supports clamps and all accessories as per site requirement and instructions complete as required, supply of ms table top stands for installing outdoor units vrf outdoor 10 units and dx outdoor 1 unit duly epoxy coated including supply of cowl piece for each outdoor machine as required, installation testing and commissioning of ms table top stands for outdoor units including installation testing and commissioning of cowl piece for each outdoor machine as required, supply and filling of refrigerant gas r410a as required for vrf and dx air conditioning systems complete with all accessories as per manufacturer recommendations and site requirements, supply of 4 core x 10 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, supply of 4 core x 16 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, laying testing and commissioning of 4 core x 10 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, laying testing and commissioning of 4 core x 16 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, providing fabricating and fixing aluminium anodized partition for air conditioning enclosure using approved aluminium sections with 15 micron anodized finish comprising fixed glazed panels and aluminium framed glazed doors with 5 mm clear float glass door shutters frames floor springs hinges handles locks rubber beading and all accessories, wiring in pvc casing and capping system using 2 x 1.5 sq mm fr pvc insulated copper conductor wire with modular type switches sockets surface mounting plastic frames for light point to be terminated in ceiling rose or batten or angle holder 6 amp 230 volts for led panel light fitting, supply and delivery of recess or surface mounted 2 x 2 luminaire 24 w with 150 lm per watt low glare and cri greater than 90 for hospital ward and corridor lighting as per instructions, installation testing and commissioning of led panel 2 x 2 24 watts to be installed at male and female ward and corridors of hospital as per instructions, supply and delivery of 4 core x 50 sq mm xlpe insulated armoured pvc sheathed heavy duty copper conductor cable 1100 volts grade conforming to is 1554 or is 7098 part 1 of 1988 complete as required, supply and delivery of galvanized iron wire size 8 swg for earthing and cable support as per specifications and instructions, installation charges for fixing and running armoured cables with copper conductors 1100 volts grade on even surfaced walls beams ceilings with appropriate gi saddles and gi spacers with gi wire from central switch chamber to ac power mcbdb at electrical switch room, cable end termination both ends for lv xlpe armoured 4 core x 50 sq mm cable including supply and fixing of double compression cable glands stripping of insulation tinned plated copper lugs for all phases crimping gi nut bolts and washers hdgi 80 micron one set per termination, supply installation testing and commissioning of three pole and neutral distribution board in sheet steel enclosure ip 43 powder coated double door horizontal surface or recess mounting with insulated tinned copper bus bars neutral links din channels earthing terminals 8 way 8 plus 24 way without mcb, supply installation testing and commissioning of four pole isolator 125 amp in suitable enclosure for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 63 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 40 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole and neutral consumer unit type distribution board in sheet steel enclosure powder coated single door with acrylic window surface or recess mounting with insulated tinned copper bus bar neutral link din channel 12 way 2 plus 10 way without mcb, supply installation testing and commissioning of double pole mcb 32 amp for hvac indoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole mcb 6 or 10 amp for hvac indoor unit distribution board as per specifications and instructions, supply delivery installation testing and commissioning of switch disconnector fuse unit sfu in sheet steel enclosure suitable for din type hrc fuses with isi mark 100amp tpn to be installed at main switch board in electrical switch room, supply installation testing and commissioning of chemical earth electrode for earthing complete with chemical powder 100 mm dia x 3 m long bore frp chamber 500 x 500 x 200 mm with frp cover earthing rod buried vertically 3 m deep resistance tested with calibrated earth resistance meter, comprehensive annual maintenance contract for air conditioning system first year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system second year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system third year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fourth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fifth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms


Agency / Dept : mumbai port trust MPT
Tender Value : 0
Due Date : Jun 25, 2026
T18 Ref No : 15072929
Location : etah , uttar pradesh
Source : GEM Tenders

tender for boq cisf 0707 floating pump , 0707 high expansion foam generator , 0707 aluminium fire suit , 0707 suction hose 100mm , 0707 smoke blower cum exhauster. , 0707stretcher , 0707lifebuoy , 0707life jacket , 0707 celling hook , 0707fire beater , 0707ejector pump , 0707 hydraulic ram , 0707hydraulic cutter , 0707hydraulic spreader , 0707 medium expansion generator , 0706 co2 fire extinguisher 4.5kg , 0706 co2 fire extinguisher 6.5kg , 0706 dcpfire extin. cartridg type-06 kg , 0706 dcpfire extin. cartridg type-09 kg , 0707 branch london type, boq cisf, 0707 floating pump specification--pump and engine specification casing-powder coated anodized aluminum as per is 617 impeller -bronze impeller 3. engine specification. engine shall meet applicable environmental norms and emission standard of govt. of india. 4 stroke air cooled petrol engine power output -not less than 5.9 hp ignition system -transistorized magneto starting system-recoil type of pump -single suction, centrifugal outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float controlled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped with fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam. 23outlet -63 mm instantaneous water discharge-not less than 900 i or min delivery head-10 meter min water depth -25 mm of water discharge of solid-up to 15 mm size automatic float controlled throttle 4. fuel tank appropriate for continuous run of at least 1 hrs and should equipped with fuel gauge. 5. float assembly hdpe shell or fiber glass with polyurethane foam, 0707 high expansion foam generator specification - high expansion foam generator shall driven by water pressure and used for coverage for large spill of hydrocarbon liquids,total flooding of voluminous enclosure such as cable ducts and in accessible locations. it should be light weight, compact, suitable for groundoperation and easy movement. it should have arrangement for smoke extraction also. it should have pressure gauge of suitable rating at inlet for measuring pressure of water flow. a carrying handles and wheels should be provided for easy and smooth carriage.body -ss or frp materials to be specified by indentor 2. nozzle -gun metal 3. foam screen -ss 4. piping and foam inductor -light weight material with anti corrosive treatment 5. fan -fibre reinforced plastic - frp-or ss-material to be specified by indentor- 6. coupling -gun metal 7. foam duct -nylon or polythene - material to be specified by indentor- 6.0 dimension of the body - shell-and attachment- 1. depth -450 - 500 mm 2. width -900- 950 mm 3. height -900- 1000 mm 4. foam duct -10 meter long 5. smoke duct -10 meter long 6. coupling diameter -63 mm - instantaneous type- 7. maximum unit weight -50 kg, 0707 aluminium fire suit specification - the suit shall allow the wearer to expose himself and withstand point source approximately at 900 degc for 4-5 minutes, 700 degc for 15 minutes and 500 degc for 5 hours without adversely affecting the wearer .the fabrication of fire proximity or approach suit shall be made out of non-flammable, light weight, non-toxic flexible and heat reflecting material. the fabric shall be of impermeable aluminized coated oxidized penotex carbon fiber and shall have thermal insulation lining capable of resisting high temperature not less than 900 degc.max.wt-9.0 kg., 0707 suction hose 100mm specification - suction hose synthetic of 100 mm internal dia and length 2.5 mtr. confirming to is 3549 latest revision. it must be fully wire embedded suction hose, which can be used from suction side of the pump from source to pump in-let. the suction hose mostly binded with copper wire with isi marked male and female threaded coupling as per is 902 - latest revision-and shall have 04 lugs. the hose shall be subjected to an internal hydraulic pressure of 8 kg or cm2 for a period of three minutes and there shall be no sign of leakage or failure. the working vacuum shall be down to 635 mm of mercury without collapse. coupling must be tested for hydraulic pressure test at 21 kg or cm2 for a period of 02 minutes. the suction hose must be protected against oil, fungus, chemicals, acid and alkalis., 0707 smoke blower cum exhauster. specification - it should be portable, high output smoke exhauster, petrol driven engine - 5.5 hp-and should be of size 18 inch or above. 2. it should be able to provide both positive and negative pressure ventilation to serve dual application i.e. as a blower as well as suction for clearance of smoke or gases even in confined or closed non ventilated areas 3. the exhauster should be compact in dimension or size and should not measure more than 20 - height-x 20 - width-x 15 - depth-with a tolerance of + or -10 percent so that it can be easily placed in the fire tender compartment if so required. 4. the exhauster unit should be light in weight and weigh less than 35 kg with a tolerance of + or - 10 percent . 5. the exhauster should have high output airflow for effective de smoking operations. 6. the fan size should be 18 diameter with many turbo blades to generate strong air force. 7. the dimensions should not exceed 18 inch in depth, 24 inch in width and 24 inch in height blade - - 18 diameter assembly should made up of aluminium or air flex fiberglass reinforced polyamide blades frame - - it should formed and welded sheet metal construction with powder -coat finish. grille - - should continuous circular wound external -weld steel wire with 4 tie points for additional safety - steel is zinc-plated with a clear chromate finish, 0707stretcher specification - stretcher sl parameters value 1. unfolded size of the stretcher - l x w x h -not less than 201 x 53 x 13 - cm-with tolerance of +- 2 mm 2. number of folds which can be made not less than 02 3. material of the stretcher frame aluminium or powder coated mild steel 4. material of the support bed of the foldable stretcher vinyl coated nylon fabric or tetron canvas 5. the foldable stretcher shall fold lengthwise and cross wise and shall fold flat for compact storage and asy transportation yes 6. support bed of the foldable stretcher shall be stain and water resistant and easy to clean and antifungal yes 7. foldable stretcher shall have aluminium feet to prevent stretcher bed from touching the floor yes 8. aluminium poles shall have rubber hand grips to keep a firm grasp on the stretcher yes 9. minimum load carrying capacity of the foldable stretcher no less than 160 kg 10. weight of the foldable stretcher not more than 20 kg 11. foldable stretcher should have patient restrain strap with double locking quick release safety buckets yes 12. vertical hoisting sling to be provided yes, 0707lifebuoy specification - 2. technical requirement- - a-the lifebuoy shall be irs approved. - b-lifebuoy shall be made up of, high visibility, impact resistant orange pe material filled with high density soft polyurethane - pu-foam which gives high floatability. - c-lifebuoy shall be provided with a grab line attached at four equally spaced points. - d-lifebuoy shall have solas retro- reflective tape stuck at four equally spaced places. - e-lifebuoy should be suitable for major application is rescue during floods and sea mishaps. - f-lifebuoy should have od 71 +- 1 cms,id 45 +- 1 cms. - g-lifebuoy should have buoyancy more than 17 kg. - h-lifebuoy shall be moisture proof and non-inflammable. 3. approvals- - a-lifebuoy shall be irs approved. - b-lifebuoy shall conforms to solas 74 as amended reg. iii or 4,iii or 7.1,iii or 34,x or 3 lsa code reg. i or 1.2 and ii or 2.1.1 imo resolution msc.81 - 70 - , msc. 200 - 80 - , msc.97 - 73-8.1,8.3., 0707life jacket specification - technical requirement- - a-it shall be made up of high visibility nylon orange coloured cloth filled with high density soft polyethylene foam to provide high floatability. - b-jacket shall be provided with suitable plastic quick lock buckle and velcro for tightening. - c-irs approved water activated life jacket light should be provided with life jacket. - d-whistle shall be attached with jacket and solas approved retro- reflective tape stitched at visible locations covering a total area not less than 400cm. - e-it shall be suitable for major application is floods and sea or river mishaps. - f-life jacket shall have size not less than 68 x 42 x 10 cm. - g-floatability shall not be less than 16.5kgs. - h-weight of jacket shall not be more than 750gms - + or -100gm - ., 0707 celling hook specification - specification of fire hook standard is 927 - 2008 the function of fire hook is to pierce celling to allow the water on the upper floor to drain away, to pull down thatched roofs or roofs made out of matting, pulling out bales and bags of various commodities from a distance,opening and closing down of doors and various similar jobs technical features - material shall steel to be used for hook conform is 2004 - 1978 - handle shall be made of bamboo of length not less than 3 m - the edges shall be well shaped and finished - forgings shall be free from seams ,burrs cracks and other surface defect - hook shall be treated with suitable anti corrosive paint - hook shall be engaged to horizontal bar and weight of 140kg shall be applied vertically to the handle .the test hall be repeated ten times .the hook shall not bend and or or dent during the test. - standard is 927 - 2008 marking each hook shall be cleary and permanently marked with the following information - manufacturer s name or trade mark - size of handle - year of manufacture - marked with standard mark note - the equipment should be procured from the manufacturers - manufacturer needs to have all test or evaluation facility in house failing which the test evaluation should got done from govt. lab or govt. approved nabl accredited lab only - pre dispatch inspection-pdi clause is mandatory and to be incorporated at the time of indent of above fire equipment. the cisf representative for inspection or pdi shall be detailed by fire directorate new delhi, standard is 8096 - 1992 fire beaters are often used for putting off small fires such as wild grass, shrubs, dry vegetation, hay, plastic, coal which can be easily put out by beating and smothering. this piece of equipment finds much application in rural areas and in those places where there is a scarcity of water components 1. handle - i-the handle shall be made of solid bamboo having 1800 mm length and 30 + 5 mm diameter or of some alternative material of heat insulate properties provided. the handle shall be finished smooth. - ii-the handle before fitting into the socket made in shank shall be liberally swabbed with termite resistant composition comprising 10 percent solution of acid-chromate composition in water. it will then be allowed to dry for at least 24 hours. - iii-the free end of the bamboo handle shall be protected from disintegrating by fitting with a hollow close ended cap made of chrome plated mild steel or aluminium. the protective cap shall have knurling made on its outer surface to enhance grip at least 5 mm of the round edges of this knurled protective cap shall be chamfered all round at 45 degree to reduce sharpness 2. blade the blade of the fire beater shall consist of a rectangular piece of expanded mild steel or steel or steel wire mesh measuring 452 mm x 352 mm, covered fully on both sides with stretched fire resistant canvas olive green in colour placed between two frames and securely fixed in position with hexagonal nut-bolts using spring washers all-round the frame the two pieces frame shall be made of 1 mm thick mild steel. the width of frame shall be 30 mm. the shank portion of the blade shall also be in two pieces made of 1 mm thick spring steel. the frame shall be welded at diagonals as per is 819-1957 assembling the blade so made shall be fixed with bamboo handle through a two piece shank. the socket part of the shank shall be tightly screwed to the bamboo handle by two bolts, nu, 0707ejector pump specification - specification 1. material of construction -aluminium alloy 2. maximum working pressure -10kg or cm2 3. minimum working pressure -5kg or cm2 4. test pressure -21kg or cm2 5. inlet diameter -100 mm - is - 902 - , male round threaded 6. outlet diameter -100 mm - is - 902 - , male round threaded 7. inst. inlet -63 mm - is - 903-instantaneous male 8. discharge -650lpm at 7kg or cm2 9. max suction depth -10 meters, 0707 hydraulic ram specification - 4. hydraulic spreader sl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent -3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707hydraulic cutter specification - technical specification or data -- hydraulic cutter should have the following specifications. a cutting force upto not less than 690 kn b capable of cutting round bar not less than 40mm dia steel rod of 500 550 mpa strength c blade opening at tips not less than 200 mm. d weight not more than 20 kg accessories -- 01. tool kit for changing curved and straight blades with spare blade. 02. connecting hoses of at least 5 meter for connecting pumps. 03. compatible pumps to achieve above mention performance of equipments., 0707hydraulic spreader specification - sl parameters value 1. conformity to standards as per nfpa 1936 with latest amendment 2. dimensions - lxbxw- - mm-not more than 900 x 285 x 250 - + 10 percent- 3. working pressure in bar 700 4. highest spreading force not less than 650 kn 5. lowest spreading force not less than 40 kn 6. spreading distance not less than 300 mm 7. pulling distance not less than 300 mm 8. highest pulling force kn not less than 34 kn 9. lowest pulling force - lpf-not less than 27 kn 10. weight including battery not more than 20 kg 11. replaceable blade of cutter yes 12. type of teeth of blade straight 13. material of blade of cutter dropped forged special steel alloy 14. material of hinges, pin, lever for protection against corrosion heat treated tool steel. 15. material of tool body to ensure less weight high quality thermoplastic 16. material of arm spreader high alloy forged light metal 17. operating temperature range -25 degc to +55 degc 18. type of battery preferably lithium ion based rechargeable 19. minimum charging time of battery not more than 120 min 20. connector to connect the tool to any 220 v power source , yes, 0707 medium expansion generator specification - foam expansion ration within the range of 1 - 300 to 1 - 600.foam output lpm-100-150 m3 or min weight-weight within the range of 20 kg to 25 kg inlet water pressure - bar-- 8 to 10 smoke exhauster-100-120 m3 or min at 08 to 10 bar inlet pressure material of construction-body or shell -s.s - 304 grade - , nozzle-g.m, foam screen-knitted fabric or s.s, fan - ,alloy aluminum, turbine-g.m., foam duct - 30 m long-- polythene, carrying handle and stand-s.s, smoke trunk-7.5 mtrs. long special construction., as per is 15683 - 2018 -with latest amendments - 1. type of extinguisher isi marked stored pressure type co2 4.5 kg capacity fire extinguisher, conforming to is 15683 - 2018 -with latest amendments - .2. extinguishing media carbon dioxide based - as per is 15222 - 3. expelling medium co2 extinguishing medium. 4. type of extinguisher high pressure extinguisher - service pressure greater than 19 bar- 5. feature of fire extinguishers yes, safety devices - mandatory for high pressure extinguisher - , rechargeable andcarrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is 15683-2018. 6. class of fire for which fire extinguisher is suitable. class-b and c 7. minimum effective discharge time-minimum 8 sec - as per 7.2.2 of is 15683 - 2018- 8. material specification for the body of highpressure extinguisher- steel body - as per latest is 7285- 9. carbon dioxide based fire extinguisher capacity in kg. 4.5 kgs. 10. operating temperature temperature range as mentioned in clause no.7.1of is 15683 - 2018. 11. fire ratings of different class of fires-minimum 34b - higher acceptable- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory. additional technical parameters- 1. marking required as per clause 10.2 of is 15683 - 2018 2. valve high pressure control valve as per is-3224 bearing isi mark and peso - ccoe - , nagpur approved. 3. test report and peso or bis certificate- a-test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. b-peso - formerly ccoe - , nagpur approval certific, 0706 co2 fire extinguisher 6.5kg specification - specification for co2 6.5 kg capacity fire extinguisher - trolley mounted- isi marked 6.5kg capacity co2 trolley mounted portable fire extinguisher confirming to is - 16018-2012 having typical shape, showing the cylinder, concave base shall be completed with following -- technical data 1. temperature working range shall be -300 c to +550 c 2. co2 fire extinguisher should be as per is-16018 - latest revision - . with isi mark. 3. filled carbon dioxide gas shall be as per is-15222 - latest revision - . 4. extinguisher should be provided with ms trolley with solid rubber wheels, handle, control discharge m e c h a n i s m with discharge hose, rubber grip, hanging clamp and n o n metallic discharge horn. 5. the minimum bursting pressure of discharge hose - wire braided-shall be 275 bar. 6. extinguisher should be class b, c and electrical fires, fire rating 55b. 7. seamless cylinder should be as per is 7285 - latest revision-with isi mark and should be approved by peso. 8. discharge valve should be wheel type as per is 3224 - latest revision-with isi mark. 9. safety device should be as per is 5903 and safety device conforming to is-5903 - latest revision-shall be in-built in discharge valve conforming to is-3224. 10. siphon tube should be of brass alloy no. 2 as per is 407. 11. finishing of paint shall be with po red as per is-5 - shade 538- 12. inspection and testing of the extinguisher shall be as per approved qap, fire extinguisher, as per is 15683 - 2018 -with latest amendments - 1. type-cartridge type with 01 spare cartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is -1568 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher shall be painted withp.o. red color conforming to shade no. 536 or, fire extinguisher, as per is 15683 - 2018 -with latest amendments- 1. type-cartridge type with 01 spare cartridge 2. extinguishing media-powder based as per is - 4308 or abc powder conforming to is - 4308 3. expelling medium or agent-n2 based - stored pressure- 4. type of extinguisher-low pressure extinguisher - service pressure 19 bar- 5. feature of fire extinguishers-carrying handle and hose assembly is mandatory as per clause no. 9.3 and 9.8 of is15683-2018 6. class of fire for which fire extinguisher is suitable- class-a, b and c 7. minimum effective discharge time-minimum 13 sec - as per 7.2.1.1 of is 15683 - 2018- 8. material specification for the body of lowpressure extinguisher- welded low carbon steel cylinders as per clause no. 9.2.5 of is - 15683 9. powder based extinguishing media-abc - mono ammonium phosphate 90 percent- 10. powder based fire extinguisher capacity in kg-06 kgs. 11. operating temperature -degc-- temperature range as mentioned in clause no.7.1 of is 15683 - 2018 12. fire ratings of different class of fires 3a, 89b - minimum- general parameters- - according to is 15683 - 2018 - latest amendment-- 1. conformity to standard is-15683-2018 - latest amendments- 2. bis marking yes 3. availability of test report from central govt. or nabl or ilac accredited lab to prove conformity to specification availability of test report from central govt. or nabl accredited laboratory additional technical parameters- 1. marking-required as per clause 10.2 of is 15683 - 2018 2. test reports test reports from central govt. or nabl accredited laboratory shall be submitted along with supply otherwise material shall be rejected. 3. bis certificate-valid bis approval certificate - is15683 - 2018-consisting cml license number shall be submitted along with offer. 4. painting-body of the fire extinguisher s, 0707 branch london type specification - multipurpose nozzle 500 lpm 1. technical requirements- - a-flow rate - selectable-- 150-250-350-500 lpm. - b-light in weight and easy to handle. - c-weight of the nozzle - 2.5 kg. - d-the calibrated flow rates are easily selectable through an indexed ring and the maximum rate is indicated by a raised lug. - e-the stream patterns are also changed by rotating the diffuser head ring with tactile marking - straight jet, spray and fog - . - f-nozzle should have flush feature for flushing any foreign items like wood or stone etc. - g-nozzle should also have metal partitions inside to restrict entry of foreign particle of bigger size. - h-nozzle should be having pistol grip, shut off ball valve opening and made of aluminium alloy. - i-nozzle shall meet the operational requirement as per en standard. - j-the head is protected with polyurethane bumper guard. the elastomers of bumper guard does not melt under heat. the teeth of nozzle should be of steel. - k-it should be of pok or elkhart or akron or rosenbaur make. - l-nozzle should have 3 stream pattern - straight jet, flash over and wide angle fog- - m-fog angle should be 130 degree. - n-inlet of the nozzle should of swivel inlet to avoid any kinking of hose 2. warranty-warranty - 1 years. service warranty - 5 years 3. pre dispatch inspection- - a-pre dispatch inspection shall be carried out at vendor s or oem site where all testing facilities as per relevant standard are available.


Tender Value : 3614370.28
Due Date : May 02, 2026
T18 Ref No : 15083225

tender for interior panelling, partition frame and frp modular toilet for middle basic unit, supply and installation of interior panelling, partition frame and frp modu lar toilet for end basic unit (dtc-01 , mc-02 & tc-01) of vande bharat chair car rake as p er specification icf/md/spec-385, rev-00 with amendment no. 5 & annexure-i including cover for arresting the gap between driver desk and nose cone along with 20mm thick acoustic insulation pa sted to the inner side of frp panel of driver cab , pasting of 3m brand film or equivalent of 80 microns thickness on the inner side of double sealed window glass and suitable cover for ccms display and su pply and installation of following items - (1) exhaust duct assembly arrangement as per mcf design l. no.- rbl- md56211 dated - 08.05.25, (2) hinged glass door for fire extinguisher shall be as per icf ca i no- b-2024/05 instead of fixed polycarbonate glass. (03) installation of acrylic cover sheet for emerg ency hammer arrgt., in trainset coaches shall be as per icf cai no.- b-2024/06 (4) replacement of exi sting wash basin drain pipe with modified wash basin drain pipe as per icf cai no.- a- 2025/06. note- 1 for spare: following items for end basic unit to be supplied in a separate box (1) toile t door - 1 nos. (2) toilet door latches/ handles- 2 nos. (3) toilet mirror - 2 nos. (4) toilet led light - 2 nos. (5) toilet tap - 2 nos. (6) toilet wash basin sink - 1 nos. (7) toilet dust bi n door -1 nos. (8) toilet dust bin container - 1 nos. (9) window roller blind 16 nos. and ( 10) electrical cubicle doors - 1 set. . note - 2 bom & drawings must be submitted at the earliest for approval after placement of po. so that timely approval for the same may be communicate d before prototype approval. - warranty period: 30 months after the date of delivery -quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs


Agency / Dept : modern coach factory MCF
Tender Value : 0
Due Date : May 20, 2026
T18 Ref No : 15702798
Location : budgam , jammu & kashmir
Source : GEM Tenders

tender for procurement of combined bathroom toilet main column of rhs 122x1x3.6 mm 9.67 kgs per rm 3m length , truss , side runner made of shs 45x45x2.6mm thick , purlin will be fabricated out of rectangular steel hollow sections , extention purlin shall be of 450mm long fabricated out of rectangular steel hollow sections , sun shade frame with sheet. , roofing sheets , false ceiling supporting angle ms 65x65x5 mm , false ceiling supporting l section of 50 x 50 x 5mm thick , wall puff panel of size 1000 width x 3000 height, 40 mm 0.50 mm , partition wall puff panel of size 1000 width x 3000 height, 40 mm , puff panel for ceiling portion of size 1000 width x 3000 height, 40 mm , main external door size 1000x2100 mm , internal doors size 750x2100 mm , fixed upvc window 1000x450 mm , ventilators with exhaust fan 250 mm sweep , inner corner flashing 50x50x3000mm, 0.5mm thick , bird cover flashing 50x250x3000mm, 0.5mm thick , outer corner 3100mm x 200mm x 200mm , ridge cover 2400mm x 300x300mm , top and bottom u flashing 40x40x65x1.5mm thick, 3000mm long , ms foundation nut and bolt 16x450mm incl water tank staging. , ms nut and bolt with washer 12x50mm for coln and truss connection , ms nut and bolt with washer 12x100mm for connecting truss and purline , ms self taping with washer screw 10x75mm , ms self taping with washer screw 10x 25mm , ms self taping with washer screw 10x 100mm , aluminium pop rivet 25mm 1000 nos per packet , peg sets ss frame 450x60x12 mm with 6 nos ss clothing pegs 75 mm each , silicon sealant , bush green colour paint , white colour paint , brown colour paint , primer red oxide , turpentine oil , column rhs 100x100x5mm thick , side bracing isa 50x50x5mm thick , base plate size 250 x 250x12mm , top frame work of staging rhs 100x100x4mm, length 2m , top cross member for stage platform rhs 75x50x3mm, length 2.82m , top chequered plate 5mm thick for staging platform size 2m x 2m , aggregate 20mm. , aggregate 40mm. , manufacture sand m sand , pcc solid concrete blocks of size 400 mm x 200 mm x 200 mm , white cement is 8042 2015 packet 01 kg , non skid ceramic tiles as per is 15622 2017 , 25mm thick factory made chequered tiles of size 300mm x 300mm , prefabricated foundation reinforcement type f 2 , quick setting compound rapidite as per is 2185 part i 2005. , liquid water proofing compound , 10mm dia reinforcement for water staging foundation , pvc ceiling rose 2 or 3 terminal as per is 371 1999 pilot 3 plate , led tube light fitting 1 x 12 w 2 feet long complete with all accessories , cable pvc insulated, unsheathed, single core, flexible copper conductor 1100v , xlpe insulated pvc seathed heavy duty armoured multi core cable 16 sqmm 2 core , modular switch one way 6 amps one module , white cover plate with frame 2 module is 3854 2023. , white cover plate with frame 3 module is 3854 2023. , pvc flush box 2 module is 14772 2000. , pvc flush box 3 module is 14772 2000. , mcb double pole 230v ac, 50 hz, 16 amps, 10ka , mcb distribution board in sheet metal enclosure two ways with blanks , ms screw 20 mm full threaded per pkt 100 nos , tape insulation 2 cm width 10 mtr long isi marked , pvc casing caping 25 mm x 16mm is 14927 part 2. , plastic body exhaust fan, 250mm sweep size with all fittings , 3 layer ppr polypropylene random copolymer pipes sdr 7.4 uv stablised, 20 mm dia , 20mm elbow suitable for 20 mm dia ppr pipe , 20mm socket suitable for 20mm dia ppr pipes , 20mm equal tee suitable for 20mm dia ppr pipe , 20mm union suitable for 20mm ppr pipes , ppr femel threaded reducer socket 15 or 20mm , ppr femel threaded reducer elbow 15 or 20 mm , ppr end plug 20mm confirming to relevant is , ppr pipe clamps suitable for 20mm piping , cp angle cock 2 way 20mm , cp angle cock 20mm , cp stop cock 20mm , bib tap short body cp 20mm bore suitable for ppr water supply line , ppr tank connector 20mm with check nut and washer , supply of 2000 litre capacity pvc rotational moulded polyethylene water storage tank , snow white colour ewc with s or p trap concealed of size 650x405x770mm with sheet cover. , vitreous china squatting pan , pvc valve less syphonic action type low level flushing cistern 10 ltrs capacity , ceramic wash basin snow white, oval bowl type with full pedestal height 795mm , 600mm x 450mm looking mirror cabinet with pvc moulded frame. , cp over head shower without arm , cp soap dish for one soap , cp toilet paper holder , cp health faucet abs body , wash basin mixer tap hot and cold , brass chromium plated bib cock long body 15mm , teflon tape , 110 x 110mm cp nahani trap with jali , pvc swr floor traps 75mm bore and jointing to waste pipe in solvent cement with cp grating. , 75mm bore pvc swr soil, waste and vent pipe, in any length, with rubber joints , 110mm bore swr pipes single socketed in any length with rubber ring joints fixed to wall and floor , 75mm or 110mm pvc swr reducer complete , 110mm pvc swr junction single, single t equal or unequal complete , pvc swr bend any radius 110mm bore as per is 10124 part 9 or 10 of 2009 , 75mm pvc swr vent cowl complete , ppr gate valves, with iron wheel head, screwed both end , anaerobic advance septic tank. , store for anaerobic advance septic, main column of rhs 122x61x3.6 mm (9.67 kgsperrm), 3.0m length each conforming to is 4923.2017, truss the principle rafter and the bottom chord shall be fabricated out of rectangular steel hollow sections of size 96mm x 48 mmx 3.6 mm (8.00 kg per rm) with 1 by 2 slopes. all other strut members will be fabricated out of rectangular steel hollow sections of size 66mm x 33 mm x 3.2 mm (4.07 kg per rm). conforming to is 4923.2017, side runner made of shs 45x45x2.6mm thick having two pales at both ends 45x90x6mm with two holes of dia 12mm welded on either ends between column to column for fixing u chanel for pir panels, purlin will be fabricated out of rectangular steel hollow sections of size 80mm x 40 mm x 3.6 mm (6.40 kgperrm) with cleats welded at both the ends conforming to is 4923.2017, extention purlin shall be of 450mm long fabricated out of rectangular steel hollow sections of size 80mm x 40 mm x 3.6 mm (6.40 kgperrm) with cleats welded at both the ends conforming to is 4923.2017, sun shade frame with sheet- sunshades shall be made out of 0.50 mm thick camouflage pattern colour coated steel sheet conforming to is 14246-2024 (or is 277-2018 reaffirmed 2022 for base galvanized sheet) fixed with angle iron frame of isa 40 x 40 x 5 mm (3.0 kgperrm) conforming to is 808-2021., roofing sheets - 0.50 mm thick ppgi camouflage pattern (is 14246-2013) of size 3000x1060mmx0.50mm zinc coating 120 gsm (is 277-2018). self-drilling hex washer head fasteners (hot-dip zinc)., false ceiling supporting angle - ms 65x65x5 mm for placing of puf 40mm thick length - 4180mm, false ceiling supporting l-section of 50 x 50 x 5mm thick (3.80 kgperrm) fixed appropriately to the truss for placing of puf 40mm thick length - 3000mm, wall puff panel of size (1000 (w) x 3000 (ht), 40 mm 0.50 mm colour-coated gi both sides, camouflage ext per off white, tongue & groove interlocking, conforming to is 16203- 2016, partition wall puff panel of size (1000 (w) x 3000 (ht), 40 mm 0.50 mm colour-coated gi both sides, bothside off white colour (intperext), tongue & groove interlocking, conforming to is 16203- 2016, puff panel for ceiling portion of size (1000 (w) x 3000 (ht), 40 mm 0.50 mm colour-coated gi both sides, bothside off white colour (intperext), tongue & groove interlocking, conforming to is 16203- 2016, main external door - size 1000x2100 mm (01 no) 2 mm thick aluminium frame (is 1948-2024). shutter- 40 mm puf (0.50 mm ppgi both sides, . fittings- 4 nos magnetic hinges (100 mm hd), 2 al sliding bolts (300 mm), al tower bolt (200 mm), 2 d-handles, 1 helical door spring, door closer (is 208-1996), padlock + 2 spare keys. canopy 1300x450 mm with isa 35x35x3 mm frame., internal doors - size 750x2100 mm (06 nos) 2 mm thick aluminium frame (is 1948-2024). shutter- 40 mm puf (0.50 mm ppgi both sides. fittings per door- 4 magnetic hinges (100 mm hd), 1 al sliding bolt (300 mm), al tower bolt (200 mm), 2 d-type handles (150 mm)., fixed upvc window - 1000x450 mm (01 no) installed at ht 2.1 m from ffl. upvc frame & shutter thick (is 17953-2023). double glazed- 5 mm + 10 mm air + 5 mm toughened safety glass (is 2553 pt 1-2018). fixed gi wire mesh 18-20 g, (is 4948-2002). anodised aluminium grill on outer side (is 733-1983). rubberperneoprene packing for weather tightness., ventilators with exhaust fan - 250 mm sweep (06 nos) 4 nos in toilet cubicles + 2 nos in bathroom cubicles. upvc frame 2 mm thick (is 17953-2023). shutter- 4 mm frostedperpinhead dg upvc fibre glass, drop-flap type, opens internally. fittings- hinges, eye hooks, tower bolt 100 mm (is 15833-2009). fly-proofing- ss wire mesh aperture on upvc outer frame. exhaust fan 200 mm with louver pre-cut at factory., inner corner flashing 50x50x3000mm, 0.5mm thick, bird cover flashing 50x250x3000mm, 0.5mm thick, outer corner 3100mm x 200mm x 200mm, ridge cover 2400mm x 300x300mm, top & bottom u flashing 40x40x65x1.5mm thick, 3000mm long conforming to is 4923- 2017, ms foundation nut & bolt 16x450mm incl water tank staging., ms nut & bolt with washer 12x50mm for coln and truss connection, ms nut & bolt with washer 12x100mm for connecting truss and purline, ms self taping with washer screw 10x75mm, ms self taping with washer screw 10x 25mm, ms self taping with washer screw 10x 100mm, aluminium pop rivet 25mm (1000 nos per packet), peg sets - ss frame 450x60x12 mm with 6 nos ss clothing pegs (75 mm) each (is 1363per1364per1367). 1 no per cubicle (6 cubicles total)., silicon sealant - 280 ml dr fixit 501 (is 12118 pt1-1987) premium acetoxy cure, with applicator gun. for sealing roofperwall panel gaps., bush green colour paint, white colour paint, brown colour paint, primer red oxide, turpentine oil, column rhs 100x100x5mm thick conforming to is 4923.2017 length - 2.6m, side bracing isa 50x50x5mm thick conforming to is 4923.2017 length - 2.9m, base plate size - 250 x 250x12mm, top frame work of staging rhs 100x100x4mm , length - 2m, top cross member for stage platform rhs 75x50x3mm , length - 2.82m, top chequered plate 5mm thick for staging platform size - 2m x 2m, aggregate 20mm. stone aggregate to be crushed rock or gravel 20mm graded confirming to is 383- 2016 and shall consist or angular fragments and shall be clean, hard, tough, durable and of uniform quality through out., aggregate 40mm. stone aggregate to be crushed rock or gravel 40mm graded confirming to relevant is 383- 2016 and shall consist or angular fragments and shall be clean, hard, tough, durable and of uniform quality through out., manufacture sand(m-sand)-- confirming to relevant is 383-2016, crushed stone sand category. the material shall be free from clay, organic impurities and deleterious material. grading shall conforming to zone ii for rcc work and zone iiiperiv for masonry and plater works. material passing through 75 micron sieve shall not exceed 15% only crushed m- sand from approved source shall be provided . test certificate from nabl approved laboratory shall be submitted at the time of delivery., pcc solid concrete blocks of size 400 mm x 200 mm x 200 mm with a compressive strength of not less than 50 kgpercm2 (approximately 5 npermm2 or 5 mpa). these solid blocks shall be manufactured using pcc mix 1-3-6 and shall fully conform to the latest applicable indian standard is 2185 (part 1)- 2005 (reaffirmed 2020). the density of the block shall be 2400 kgperm3, white cement is 8042 - 2015 (packet 01 kg), non skid ceramic tiles as per is 15622-2017 of size 300x300mm x 10mm mm thick 1st quality as per approved sample., 25mm thick factory made chequered tiles of size 300mm x 300mm made in grey cement with pigment conforming to is 1237-2012 and is-13801-2013 respectively., prefabricated foundation reinforcement type f-2 made of 12 mm & 10 mm for steel as main bars and 8 mm dia deformed bars as in stirrups as per drg including notes, cutting bending & binding with mild steel binding wire annealed not less then 0.90 mm dia complete all as per drg conforming to is 1786 - 2008 (reaffirmed 2023), is 456- 2000 and is 2502 - 2004 (reaffirmed 2024, quick setting compound (rapidite) as per is 2185 (part-i) 2005., liquid water proofing compound is-2645-2003 (reaffirmed - 2005) (using instruction-- specification for integral waterproofing compounds at the time of making concrete as per the manufacturer instructions)., 10mm dia reinforcement for water staging foundation, pvc ceiling rose 2per3 terminal as per is 371-1999(pilot 3 plate), led tube light fitting 1 x 12 w 2 feet long complete with all accessories, including led tube rod as per is 10322 (part 5persec 1) -2026, cable pvc insulated, unsheathed, single core, flexible copper conductor 1100v grade of size 1.5 sqmm is 694-2010,, xlpe insulated pvc seathed (heavy duty) armoured multi core cable 16 sqmm 2 core aluminum conductor for working voltage up to & including 1100 volt confirming to relevant is 1554 (part - i) - 2020 per is-7098 (part - i) 2025 with latest amendments ., modular switch one way 6 amps one module confirming to is 4160-2005, white cover plate with frame 2 module is 3854 - 2023., white cover plate with frame 3 module is 3854 - 2023., pvc flush box 2 module is 14772 - 2000., pvc flush box 3 module is 14772 - 2000., mcb double pole 230v ac, 50 hz, 16 amps, 10ka confirming to is - 8828-1996 iec 60898 - 2002, suitable for lighting & other domestic loads., mcb distribution board in sheet metal enclosure two ways with blanks conforming to is 8828 -1978,, ms screw 20 mm full threaded (per pkt-100 nos) conforming to is 723-1972, tape insulation 2 cm width 10 mtr long isi marked, pvc casing caping 25 mm x 16mm is 14927 (part-2)., pvc casing caping square box 4 x 4 inch as per is 14927 (part-2)., plastic body exhaust fan, 250mm sweep size with all fittings as per is 2312 -1967 (reaffirmed 2020), 3 layer pp-r polypropylene random copolymer) pipes sdr 7.4 uv stablised and 20 mm dia, thickness of wall 2.20 confirming to relevant is 15801-2008, 20mm elbow suitable for 20 mm dia pp-r pipe confirming to relevant is 15801-2008 (reaffirmed 2022), 20mm socket suitable for 20mm dia pp-r pipes confirming to relevant is 15801-2008 (reaffirmed 2022), 20mm equal tee suitable for 20mm dia pp-r pipe confirming to relevant is 15801-2008 (reaffirmed 2022), 20mm union suitable for 20mm pp-r pipes confirming to relevant is 15801-2008 (reaffirmed 2022), ppr femel threaded reducer socket 15per20mm is 15801-2008 (reaffirmed 2022), ppr femel threaded reducer elbow 15per20 mm is 15801-2008 (reaffirmed 2022), pp-r end plug 20mm confirming to relevant is is 15801-2008 (reaffirmed 2022)., pp-r pipe clamps suitable for 20mm piping is 15801-2008 (reaffirmed 2022), cp angle cock 2 way 20mm confirming to relevant is 15801-2008 (reaffirmed 2022), cp angle cock 20mm confirming to relevant is 15801-2008 (reaffirmed 2022), cp stop cock 20mm confirming to relevant is 15801-2008 (reaffirmed 2022), bib tap short body cp 20mm bore suitable for ppr water supply line . isi marked, conforming to is 781 -1984., pp-r tank connector 20mm with check nut and washer is 15801-2008, supply of 2000 litre capacity pvc rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittingsper fixtures for connecting inlet, outlet, washout and overflow pipes, hoisted incl ball brass valve, high pressure with polythene float and flynut complete, snow white colour ewc with s or p trap concealed of size 650x405x770mm wih sheet cover., vitreous china squatting pan, orissa pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern but incluing flush pipe (l pipe) and with with p or s trap front or back inlet complete all as specified and as directed ., pvc valve less syphonic action type low level flushing cistern 10 ltrs capacity col - white with flushing pipe to match european type wc incl 15mm pvc connecting pipe with fixing brackets complete accessories. conforming to is 774-1984., ceramic wash basin snow white, oval bowl type with full pedestal height 795mm, size 550 x 400 x 155mm depth with stainless steel heavy quality bottle trap set with height adjustable waste outlet pipe for wash basin as per is 2556 - 2021 (part 4)-2021,, 600mm x 450mm looking mirror cabinet with pvc moulded frame. as per hs code 700999200, cp over head shower without arm confirming to relevant is 1172-1993 (reaffirmed in 2022)., cp soap dish for one soap confirming to relevant is 2556-2004., cp toilet paper holder (hsnperhs code 74182010), cp health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and abs wall hook including making connections and fixed in position hsn 39229000,, wash basin mixer tap (hot and cold)- long body decorative type pillar tap of 20 mm nominal diameter, chromium plated, heavy duty, isi marked, suitable for 20 mm ppr water supply line, conforming to is 1795 (latest), including necessary connecting accessories., brass chromium plated bib cock long body 15mm, teflon tape is 14643-1999, 110 x 110mm cp nahani trap with jali is 14735 -1999 (reaffirmed 2021), pvc (swr) floor traps 75mm bore and jointing to waste pipe in solvent cement alongwith cp grating ., 75mm bore pvc (swr) soil, waste and vent pipe, in any length , with rubber joints,fixed vetically on wall as per is 13592-2013, 110mm bore (swr) pipes single socketed in any length with rubber ring joints fixed to wallsperfloor complete all as specified and directed as per is 13592-2013, 75mm per110mm pvc (swr) reducer complete all as specified as per is 14735 -1999, 110mm pvc (swr) junction single, (single t) equal or unequal complete all as specified as per is 14735 -1999, pvc (swr) bend any radius 110mm bore complete all as specified and directed as per is 10124 (part 9 or 10) -2009, 75mm pvc (swr) vent cowl complete all as specified as per is 13592-2013, ppr gate valves, with iron wheel head, screwed both end for ppr pipe and fixed to 20 mm bore ppr pipe complette all as specified and as directed., anaerobic advance septic tank. supply of pwts service polyethylene tank (advance version septic tank) with capacity of 1500 ltr diameter of 1300mm and height of 1400mm. drawing and features as per appx b confirming on is 2470 (part-1 and 2)- 1985 (reaffirmed 2017) ., store for anaerobic advance septic tank as per list attached as annexure 1


Agency / Dept :
Tender Value : 0
Due Date : Jun 19, 2026
T18 Ref No : 15702799
Location : budgam , jammu & kashmir
Source : GEM Tenders

tender for procurement of store shelter truss , partition truss , main column of rhs , side column for steel door , runner front and back side of each shelter , runner partition or gable end , runner front and back door sides , purlin of rectangular steel hollow sections , ms extention purlin , ms sunshade with sheet 0.63mm thick 1400 x 450mm for door. , ms sunshade with sheet 0.63mm thick 1500 x 450mm for window , corner posts angle shall be fixed with the columns. , top runner shs 45x45x2.9 mm steel sections , ms sheet top and bottom u channel 3000mm length , false ceiling supporting angle ms 65x65x5 mm , for wall pre-painted gi both sides, tongue and groove , for ceiling- pre-painted gi both sides, tongue and groove , ppgi outer corner flashing 200x200x3050mm , door flashing of size 100x100x2700mm , door flashing of size 100x100x1500mm , window flashing of size 50x50x1100mm , ppgi ridge cover 450x450x3050mm , ppgi inner corner flashing 100x100x2700mm, colour white , ppgi inner corner ceiling flashing 50x50x3000mm l shaped , ppgi camouflage roof sheet 4000x1060mm x 0.63mm , ppgi camouflage wall cladding sheet 3050x1060mm x 0.63mm , ppgi camouflage for inner partition wall cladding sheet , polycarbonate roof sheet 4000mmx1060mm x 3 mm , ppgi camouflage for gable wall cladding sheet 3000x1060mm x 0.63mm , ms foundation bolt 16x450mm , ms nut and bolt 12 x 40 mm , ms nut and bolt 12 x 100 mm , ms nut and bolt 16 x 50 mm connect of truss and purlins , ms nut and bolt 10x75 and washer for fixing of sunshed , gi self tapping screw 75mm for fixing panel with coln , gi self tapping screw 25mm for fixing of inner flasing , gi self tapping screw 50mm for fixing of roof sheet , double shutter steel doors , windows , one insulated puf door shutter with aluminium frame , one fixed glass window of size 2.00m wide x 1.20m high , padlock with 7 levers 50mm, with 3 nos spare key , silicon sealent 280 ml , manufacturing sand m sand , aggregate 20mm. , aggregate 40mm. , bricks, common burnt clay building bricks sub class b , non skid ceramic tiles of size 400 x 400 x 7 to 8mm , glass dividing strips 40x4mm , prefabricated foundation reinforcement type f-2 , steel form work -type -2 , lightning conductor , pvc ceiling rose 2 or 3 terminal. , led tube light fitting complete 4 feet long 18 watt , xlpe insulated pvc seathed heavy duty armoured multi core cable 16 sqmm 2 core , cable pvc insulated and pvc seathed 1.5 sqmm single core , modular switch one way 6 amps one module , ms screw 20 mm full threaded per pkt 100 nos , ms screw 25 mm full threaded per pkt 100 nos , tape insulation 2 cm width 10.00mtr long isi marked , mcb single pole 230v ac, 50 hz, 6 amps, 10ka , mcb distribution boards in sheet metal enclosure 4 ways single door with blanks , residual current circuit breaker with overload and short circuit protection double pole 32 amps , modular socket 6a 2 or 3 pin combined 2 module , white cover plate with frame 2 module , white cover plate with frame 4 module , metal flush box 2 module , metal flush box 4 module , pvc casing caping pipe 25mm x16mm , pvc casing caping l bend 25mm , pvc casing caping elbow 25mm dia , pvc casing caping t 25mm for conduit pipe , pvc casing caping square box 4 x 4 inch , wall mtd fan 400mm , office chair . , office table , ss dustbin 10 ltrs capacity , fire extinguisher 06 kgs capacity, abc powder , brush 150mm , brush 100mm , brush 50mm, truss - the principle rafter and the bottom chord shall be fabricated out of rectangular steel hollow sections of size 96mm x 48 mmx 4.00 mm (8.22 kg/rm), partition truss - the principle rafter and the bottom chord shall be fabricated out of rectangular steel hollow sections of size 96mm x 48 mmx 4.00 mm (8.22 kg/rm), main column of rhs 122 x 61 x 3.6 mm 9.67 kgs per rm, side column for steel door of rhs 122 x 61 x 3.6 mm (9.67 kgs per rm), 2.825m length each, runner front and back side length 3660mm, runner partition or gable end length 6100mm, runner front and back door sides length 2450mm, purlin of rectangular steel hollow sections of size 96mm x 48 mm x 4.0 mm (8.22 kg per rm) with 6mm thick, ms extension purlin shall be of 450mm long fabricated out of rectangular steel hollow sections, 1400 x 450mm for door., ms sunshade with sheet 0.63mm thick 1400 x 450mm for door., ms sunshade with sheet 0.63mm thick 1500 x 450mm for window, top runner shs 45x45x2.9 mm steel sections, ms sheet top and bottom u channel 3000mm length, false ceiling supporting angle ms 65x65x5 mm, for wall pre-painted gi both sides, tongue and groove, for ceiling- pre-painted gi both sides, tongue and groove, ppgi outer corner flashing 200x200x3050mm, door flashing of size 100x100x2700mm, door flashing of size 100x100x1500mm, window flashing of size 50x50x1100mm, ppgi ridge cover 450x450x3050mm, ppgi inner corner flashing 100x100x2700mm, (colour white), ppgi inner corner ceiling flashing 50x50x3000mm (l shaped), ppgi camouflage roof sheet 4000x1060mm x 0.63mm, ppgi camouflage wall cladding sheet 3050x1060mm x 0.63mm, ppgi camouflage for inner partition wall cladding sheet, polycarbonate roof sheet 4000mmx1060mm x 3 mm, ppgi camouflage for gable wall cladding sheet 3000x1060mm x 0.63mm, ms foundation bolt 16x450mm, ms nut and bolt 12 x 40 mm, ms nut and bolt 12 x 100 mm, ms nut and bolt 16 x 50 mm (connect of truss and purlins), ms nut and bolt 10x75 and washer for fixing of sunshed, gi self tapping screw 75mm (for fixing panel with coln), gi self tapping screw 25mm (for fixing of inner flasing), gi self tapping screw 50mm (for fixing of roof sheet), double shutter steel doors will be provided in each store shelter as shown in the drawing., windows in each shelter will be provided. window size will be 1.20m x 1.20 m with two vertical panels, one insulated puf door shutter with aluminium frame of suitable size shall be provided complete with pressed steel or u-channel frame, one fixed glass window of size 2.00m wide x 1.20m high shall be provided complete with ms frame, necessary cleats, rubber beading and transparent glass of minimum 5mm thickness, padlock with 7 levers 50mm, with 3 nos spare key., silicon sealant 280 ml, manufacturing sand (m- sand) confirming to is 383-2016, crushed stone sand category., stone aggregate to be crushed rock or gravel 20mm graded conforming to is 383-2016, stone aggregate to be crushed rock or gravel 40mm graded conforming to is 383-2016, common burnt clay building bricks sub class b modular size designation 75kgf per cm2, best locally available with sharp corners, non skid ceramic tiles of size 400 x 400 x 7-8mm conforming to is 15622 2017, glass dividing strips 40x4mm, prefabricated foundation reinforcement type f-2 made of 12 mm & 10 mm for steel as main bars and 8 mm dia deformed bars as in stirrups us as per drawings, steel form work -type -2 -steel form work material for columns of size 0.3 x 0.3 x 0.9m and columns footing of size 0.9 x 0.9 x 0.3 m ( type f-2) made out of 3mm thick ms sheet, lightning conductor confirming to is - 3043 - 2018 with all accessories, pvc ceiling rose 2 or 3 terminal., led tube light fitting complete 4 feet long 18 watt tube rod and electronic ballast, xlpe insulated pvc seathed (heavy duty) armoured multi core cable 16 sqmm 2 core aluminum conductor for working voltage up to and including 1100 volt, cable pvc insulated and pvc seathed 1.5 sqmm single core with copper conductor suitable upto 450 per 750 v, modular switch one way 6 amps one module, ms screw 20 mm full threaded (per pkt-100 nos), ms screw 25 mm full threaded (per pkt-100 nos), tape insulation 2 cm width 10.00mtr long isi marked, mcb single pole 230v ac, 50 hz, 6 amps, 10ka, mcb distribution boards in sheet metal enclosure 4 ways single door with blanks, residual current circuit breaker with overload and short circuit protection double pole 32 amps, modular socket 6a-2 or 3 pin combined 2 module, white cover plate with frame 2 module, white cover plate with frame 4 module, metal flush box 2 module, metal flush box 4 module, pvc casing caping pipe 25mm x16mm, pvc casing caping l bend 25mm, pvc casing caping elbow 25mm dia, pvc casing caping t 25mm for conduit pipe, pvc casing caping square box 4 x 4 inch, wall mtd fan 400mm, office chair (plastic) with cushion, without rest, consists of office table with key board drawer and table top conforming to is 12823 of 2015 pre-laminated particle boards, ss dustbin 10 ltrs capacity, fire extinguisher 06 kgs capacity, abc powder map-90 alongwith its accessories, brush 150mm, brush 100mm, brush 50mm


Agency / Dept :
Tender Value : 0
Due Date : Jun 19, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to partition frame spares. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the partition frame spares sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the partition frame spares Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in partition frame spares, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our partition frame spares Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For partition frame spares Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for partition frame spares.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for partition frame spares depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For partition frame spares Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for partition frame spares bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of partition frame spares. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for partition frame spares, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to partition frame spares, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in partition frame spares?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based partition frame spares tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for partition frame spares?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for partition frame spares, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for partition frame spares is declared L1 and is generally awarded the contract