Search Tenders
Filters
Reset All
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source
Tender Type

112Latest Insulator testing Tenders List

Latest Insulator testing Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Insulator testing tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Insulator testing tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Insulator testing Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Insulator testing tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Insulator testing Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Insulator testing Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Insulator testing Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Insulator testing tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Insulator testing Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Insulator testing sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Insulator testing tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Insulator testing tenders.

Is EMD mandatory for all Insulator testing tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Insulator testing work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Insulator testing tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Insulator testing Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16424008
Location : bardhaman , west bengal
Source : GEM Tenders
NEW TENDER
tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip size 185 sq mm 3.5 core , excavation in trenches not exceeding 1.5 m widthandnot exc 1.5m in depth getting out in soft loose soil etc. , excavation in trenches not exceeding 1.5 m widthandexc 1.5m in depth getting out in soft loose soil etc. , returning filling in including spreading levelling wateringandwell ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 manddepositing where directed by engr in charge. , supplyandlay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supplyandlay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep etc. , mandl for double wall corrugated dwc high density polyethylene pipes hdpe of 90mm etc. , mandl for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , mandl for manual boring under road crossingandlaying pipe across the road etc. , sandf pcc cable route marker of size 900x300x70mm embossed with ht ug cable etc. , materialandlabour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc. , m and l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 etc. , m and l for cross arms bracing supports clampsandback plates fabricated from structural steel etc. , m and l for pin type porcelain polymer vitreous brown insulator of size 150mm height 150mm etc. , m and l for disc type porcelain polymer insulator vitreous 145 mm heightand255 mm diameter etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc. , mandl for cement concrete in foundations fillingandmass concrete etc. , mandl for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation etc. , mandl for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping etc. , m and l for earthing complete with galvanised steel earth plate electrode etc. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried etc. , mandl cable jointing kit for 11 kv earthed grade cable for outdoor termination heat shrink type joint etc. , m and l cable jointing kit for 11 kv earthed grade cable for straight through heat shrink type joint complete with jointing etc. , wrecking crow bar or claw bar as per is 706 (q3), supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11100 volts grade, of size 185 sq mm 3.5 core all as specifiedandas directed., excavation in trenches not exceeding 1.5 m widthandnot exc 1.5m in depth getting out in soft/loose soil all as s+b1+c2 c13+c2 c15+b1+c2 c13+c2 c2 c15, excavation in trenches not exceeding 1.5 m widthandexc 1.5m in depth getting out in soft/loose soil all as specifiedandas directed., returning filling in including spreading levelling wateringandwell ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specifiedandas directed., removal of surplus soil to a distance not exceeding 50 manddepositing where directed by engr in charge., supplyandlay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm complete all as specifiedanddirected., supplyandlay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before layingand15cm covering above the top edge of cable after laying & punned down to required height, complete all as specifiedandas directed. note only punned thickness shall be measured & paid., m&l for double wall corrugated (dwc) high density polyethylene pipes (hdpe) of 90mm dia laid in trenches for cable protection complete all as spcifiedanddirected., m&l for fixing gi tubing 80mm dia light grade use for the protection of cable all as specifiedanddirected by engr in charge., m&l for manual boring under road crossingandlaying pipe across the road for laying cables complete all as specifiedandas directed., s&f pcc cable route marker of size 900x300x70mm, embossed with ht ug cable 11kv andexcavation of 40cm depth, grouted inandincluding pcc (1 2 4) type b 2 (using 20mm graded stone aggregate) complete all as specifiedanddirected., materialandlabour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 sp 55, 11.00 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of yellow/ sky blue paint (as per existing pattern through out the circumference of pole), including all internal surfacesandexternal surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specifiedandas directed complete all as specified. (note earth work, pcc work, shall be measuredandpaid separately.), m & l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle ac suitable for current rating upto 400 amps mechanically operated mounted on porcelain/polymer insulators (9 insulators)andframe with operating mechanism worked from ground level with earth switchandincluding locking arrangement, acsr conductor complete with taking down old unserviceable complete all as specifiedanddirected., m & l for 11 kv, 200 amps, outdoor type horn gap fuse set conforming to is 9385 (part i & ii) / relevant latest is standards, complete with galvanized steel horn assembly, suitable fuse element, heavy duty porcelain/polymer insulators, gi channel/angle mounting structure, connectors, clamps, nuts, boltsandall accessories, installed on pole mounted ht structure complete including taking down old unserviceable all as specifiedanddirected., m & l for cross arms , bracing, supports , clampsandback plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross armsandcomplete all as specifiedandas directed., m & l for pin type, porcelain/polymer, vitreous brown insulator of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washersandone galvanized iron nut complete all as specifiedandas directed., m & l for disc type porcelain/polymer insulator, vitreous, 145 mm heightand255 mm diameter, ballandsocket type, suitable for 11,000 volts grade, complete with one galvanized mild steel spindle, two galvanized iron washersandone galvanized iron nut, complete in all respects, as specifiedandas directed., m & l for lightning arrester/surge protector 11 kv grade heavy duty, single pole, self supporting station, expulsion type class 65 ka capacity with all fittings complete all with taking down old unserviceable all as specifiedanddirected., s & f danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figuresandconventional skullandbones in signal red colourandfixed with m.s. clamps, boltsandnuts of approved size, for ht, 25x20cm size complete all as specifiedanddirected., m&l for cement concrete in foundations, fillingandmass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 3 6 type c2 (using 40mm grade aggregate) as in foundation for pole etc complete all as specifiedandas directed., m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form workandfinishing the surfaces evenandsmooth etc complete all as specifiedanddirected., m and l for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4 mm as earth lead alongwith gi protection pipe by means of bolts nuts check nutsandwashers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test pointandpcc earth pitandci coverand funnel with watering pipe wire mesh earth lead protection pipe etc complete all as specified or indicated including testing on completion, m & l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete, m&l cable jointing kit for 11 kv (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materialandaccessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185 sqmm 3 core, complete all as specifiedanddirected., m & l cable jointing kit for 11 kv (earthed) grade cable for straight through heat shrink type joint complete with jointing materialandaccessories suitable for 3 core xlpe armoured aluminium conductor cable of size 185 sqmm, complete all as specifiedanddirected.
T18 Ref No : 16424015
Location : bardhaman , west bengal
Source : GEM Tenders
NEW TENDER
tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip or wire etc. , excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth etc. , excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth etc. , returning filling in including spreading levelling watering and well ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 m and depositing etc. , supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. , m and l for double wall corrugated dwc high density polyethylene pipes hdpe etc. , m and l for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , m and l for manual boring under road crossing and laying pipe across the road etc. , s and f pcc cable route marker of size 900x300x70mm embossed with ht ug cable etc. , material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc. , m and l for switch air break gang operated triple pole out door type unit etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 etc. , m and l for cross arms bracing supports clamps and back plates fabricated etc. , m and l for pin type porcelain vitreous brown insulator of size 150mm etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled etc. , m and l for cement concrete in foundations filling and mass concrete type d2 1 etc. , m and l for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation etc. , m and l for pcc 1.2.4 type b1 using 20mm grade aggregate etc. , m and l for earthing complete with galvanised steel earth plate electrode 60x60cm etc. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten etc. , dismantling of acsr or aac conductors , dismantling concrete poles struts any size , dismantling cross arms of m.s. channel or angle sections etc. , dismantling insulators any type any size , pick axe as per is 273 (q4), supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 95 sq mm 3 core all as specified and as directed., excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed., removal of surplus soil to a distance not exceeding 50 m and depositing where directed by engr in charge., supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm complete all as specified and directed., supply and lay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying & punned down to required height, complete all as specified and as directed. note only punned thickness shall be measured & paid., m&l for double wall corrugated (dwc) high density polyethylene pipes (hdpe) of 90mm dia laid in trenches for cable protection complete all as spcified and directed., m&l for fixing gi tubing 80mm dia light grade use for the protection of cable all as specified and directed by engr in charge., m&l for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed., s&f pcc cable route marker of size 900x300x70mm, embossed with ht ug cable 11kv and excavation of 40cm depth, grouted in and including pcc (1 2 4) type b 2 (using 20mm graded stone aggregate) complete all as specified and directed., material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 sp 55, 11.00 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of yellow/ sky blue paint (as per existing pattern through out the circumference of pole), including all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed complete all as specified. (note earth work, pcc work, shall be measured and paid separately.), m & l for switch air break gang operated triple pole out door type unit on ht 11 kv 50 cycle ac suitable for current rating upto 400 amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement, acsr conductor complete with taking down old unserviceable complete all as specified and directed., m & l for 11 kv, 200 amps, outdoor type horn gap fuse set conforming to is 9385 (part i & ii) / relevant latest is standards, complete with galvanized steel horn assembly, suitable fuse element, heavy duty porcelain/polymer insulators, gi channel/angle mounting structure, connectors, clamps, nuts, bolts and all accessories, installed on pole mounted ht structure complete including taking down old unserviceable all as specified and directed., m & l for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed., m & l for pin type, porcelain, vitreous brown insulator of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut complete all as specified and as directed., m & l for lightning arrester/surge protector 11 kv grade heavy duty, single pole, self supporting station, expulsion type class 65 ka capacity with all fittings complete all with taking down old unserviceable all as specified and directed., s & f danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for ht, 25x20cm size complete all as specified and directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 3 6 type c2 (using 40mm grade aggregate) as in foundation for pole etc complete all as specified and as directed., m and l for pcc 1.2.4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4 mm as earth lead alongwith gi protection pipe by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point and pcc earth pit and ci cover and funnel with watering pipe wire mesh earth lead protection pipe etc complete all as specified or indicated including testing on completion., m & l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete, dismantling of acsr or aac conductors, dismantling concrete poles/ struts, any size, dismantling cross arms of m.s. channel or angle sections etc. complete and setting aside for re use with in 50m, dismantling insulators any type, any size

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16424060
Location : bardhaman , west bengal
Source : GEM Tenders
NEW TENDER
tender for supply laying and testing cable xlpe insulated screened pvc bedded galvanized steel strip etc. , excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting etc. , excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out etc. , returning filling in including spreading levelling watering and well ramming in layers etc. , removal of surplus soil to a distance not exceeding 50 m and depositing where etc. , supply and lay of pcc cable cover class hv type 1 flat size 300mmx180mmx40mm etc. , supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. , m and l for double wall corrugated dwc high density polyethylene pipes hdpe of 90mm dia etc. , m and l for fixing gi tubing 80mm dia light grade use for the protection of cable etc. , m and l for manual boring under road crossing and laying pipe across the road etc. , sandf pcc cable route marker of size 900x300x70mm embossed with ht ug etc. , material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts etc. , m and l for switch air break gang operated triple pole out door type unit on ht 11 kv etc. , m and l for 11 kv 200 amps outdoor type horn gap fuse set conforming to is 9385 part i and ii etc. , m and l for cross arms bracing supports clamps and back plates fabricated from structural etc. , m and l for pin type porcelain vitreous brown insulator of size 150mm height 150mm etc. , m and l for lightning arrester surge protector 11 kv grade heavy duty single pole etc. , s and f danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc. , m and l for cement concrete in foundations filling and mass concrete type d2 etc. , m and l for pcc 1 3 6 type c2 using 40mm grade aggregate as in foundation for pole etc. , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole etc. , m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick etc , m and l for earth continuity conductor or main earthing lead fixed to wall on batten etc. , m and l for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm etc. , pick axe as per is 273 (q4), supply, installation, testing of current transformer 33kv, single phase, outdoor oil filled , ratio 150 75/5 5a , two core, one metering (burden 15va, accuracy class 0.5) and one protection core (burden 30va, accuracy class 5p20) insulation level 36 kv / 70 kv as per is 2705 to suit vcb make complete incl taking out old ct all as per sample and directed., supply, installation, testing of 33 kv single phase out door oil cooled pt of ratio 33 kv/ rt 3 / 110 v/rt 3 accuracy class 1.0 . burden 100va. insulation class 70/170 kv , voltage fector 1.2 cont and 1.5 for 30 sec , confirming to is 3156 complete (as per sample) incl taking down old unserviceable pt all as specified and directed., supply & fixing of 33 kv disc type suspension insulator, porcelain/polymer type, 70 kn mechanical strength, complete with cap and pin, ball & socket type coupling, suitable for 33 kv overhead line, conforming to is 731, including all fittings and accessories complete all as specified and directed., supply & fixing of 33 kv post type insulator, porcelain/polymer, brown glazed, suitable for 33 kv overhead line, complete with gi pin, lead thimble, and all accessories, conforming to is 731 / is 2544 complete all as specified and directed., preparation of detailed layout drawing in autocad and supply, fabrication, uv printing/engraving and fixing of 33 kv main receiving station layout, powerhouse no 2 layout and powerhouse no 1 layout on acp board, comprising site verification, preparation/finalization of single line diagram (sld) and equipment layout in autocad, submission for approval, high resolution uv printing or cnc engraving on minimum 3 mm thick aluminium composite panel (acp), protective coating, aluminium framing, and wall mounting complete in all respects., m & l for filling and spreading aggregate/stone using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc., m&l for surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed., m&l 150 mm thick soiling (or sub base) with broken boulders or quarried stone, interstices filled, suface formed and rolled and consolidated to required gradient and camber all as specified and directed., m&l for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed., m&l for pcc 1 4 8 type d 2 (40mm graded aggregate) in foundations, filling and mass concrete., m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., supply and fix led tube light fitting surface and wall mounted batten with 20 watts led including removal of old one complete all as specified and directed., m and l for earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point all as specified or indicated including testing on completion, excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed., returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed., removal of surplus soil to a distance not exceeding 50 m and depositing where directed by engr in charge., m&l for fixing gi tubing 15mm dia light grade use for the protection of earthing lead., m&l for fixing gi tubing 20mm dia light grade use for watering to earthing, m&l for funnel, wire mesh, lugs, nut, bolts etc, m&l for ms angle frame and sheet cover, m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) for earth pit chamber inclduing form work and finishing the surfaces even and smooth etc complete, m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete, m and l for disc type porcelain/polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11 000 volts grade complete with one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut complete in all respects as specified and as directed.
T18 Ref No : 16429011
Location : jodhpur , rajasthan
NEW TENDER

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16239965
Location : pune , maharashtra
Source : GEM Tenders
LIVE TENDER
tender for repair including replacement of 1 set of led indicators red, yellow, blue or green , repair including replacement of ac ammeter 0 to 200 a class 1, analog 96 mm , repair including replacement of ac voltmeter 0 to 500 v class 1, analog 96 mm , repair including replacement of hn type 63 a fuse link , repair including replacement of voltmeter selector switch , repair including replacement of 3 position ammeter selector switch , repair including replacement of 100 a, 415 v, 4 pole isolator , supply installation testing and commissioning of 22 kv drop out fuse and rod assembly without insulators , repairing and calibration of existing apfc relay of syntron make , carrying out servicing, chemical descaling and high- pressure jet cleaning of the radiator of 250 kva dg set , replacement of stop solenoid valve with solenoid switch suitable for existing 250 kva ea set , replacement of battery terminal socket set for dg starting battery for existing 250 kva ea set , repairing, rewinding of 5 hp centrifugal pump set , replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve , replacement of faulty pcb of indoor unit of 1.5 tr or 2.0 tr inverter type split ac unit , repairing of 1.5 or 2.0 tr window or split or high sensible ac units by attending of leakage , replacement of faulty batten tube light fitting with supplying and fixing of 20 to 28 watt led type tube light fitting , rewinding of ceiling fan motors with sweep up to 1400 mm , rewinding of exhaust fan motors with sweep up to 450 mm , replacement of faulty 100 watt, step type electronic fan regulator on the existing switchboard , replacement of faulty switch 5 or 6 amp on the existing switchboard , replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard , replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard , replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db , replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db , repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable, ocm of ems at te compound at bhosari pune sh attending defects at rnc, repair including replacement of 1 set of led indicators comprising red, yellow, blue or green indicators on mv or lt or dg panel with compatibility to exisitng available system, testing etc as reqd., repair including replacement of ac ammeter 0 to 200a class 1, analog 96 mm size on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of ac voltmeter 0 to 500v class 1, analog 96 mm on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of hn type 63 a fuse link in mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of voltmeter selector switch on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of 3 position ammeter selector switch on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., supplying and fixing of 100 a, 415 v, 4 pole isolator in mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., supply, installation, testing and commissioning of 22 kv drop out fuse and rod assembly without insulators etc complete as required, repairing and calibration of existing apfc relay of syntron make for 135 kvar capacitor panel including auto mode operation and on load testing etc complete as reqd., carrying out servicing, chemical descaling and high-pressure jet cleaning of the radiator of 250 kva dg set incl. dismantling radiator, replacement of rubber hoses and clamps, coolant top up etc., replacement of stop solenoid valve with solenoid switch suitable for existing 250 kva ea set with installation, connection, testing, commissioning as reqd., replacement of battery terminal socket set for dg starting battery for existing 250 kva ea set with installation, connection, testing, commissioning as reqd., repairing, rewinding of 5 hp centrifugal pump set incl. greasing, varnishing, replacement of wornout bearings and gland packing incl. dismantling, handling, transportation and reinstallation etc., replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve, with all accessories including testing commissioning etc complete as required, replacement of faulty pcb of indoor unit of 1.5 tr or 2.0 tr inverter type split ac unit including installation, connection, testing and commissioning etc complete as reqd., repairing of 1.5 or 2tr w or s or hs ac units by attending of leakage incl. brazing or flaring leak points, vacumising, purging flushing and supplying and charging of r22orr32orr410orr134 gas etc, replacement of faulty batten tube light fitting with supplying and fixing of 20 to 28 watt led type tube light fitting incl. testing commissioning etc complete as required, rewinding of ceiling fan motors with sweep up to 1400 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd, rewinding of exhaust fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., replacement of faulty 100 watt, step type electronic fan regulator on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty switch 5 or 6 amp on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db including connections, testing and commissioning as reqd., repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable from pole junction box to fitting etc. complete as reqd.
T18 Ref No : 15892644
Location : bangalore , karnataka
LIVE TENDER
tender for low maintenance stationary lead acid battery sets along with all accessories for installation in the control room at unattended tss consisting of set of 55 cells of 2 volt, 200ah conforming to rdso spec. rdso/pe/spec/tl/0040 (rev.2) 2021. lead acid (tubular positive and pasted negative plates) stationary batteries 110v 200ah (comprising 55 cells of 2v each) capacity at 10hrs. rate of discharge assembled in ppcp container with intercell connectors, inter row connectors, inter tier connectors, stainless steel fasteners, micro porous vent plug, electrolyte level indicators, and porcelain cells insulators in dry and uncharged condition and electrolyte, user manual, routine and acceptance test reports as per rdso spec. to be supplied along with battery test. maintenance accessories and electrolyte, low maintenance stationary lead acid battery sets along with all accessories for installation ation in the control room at unattended tss consisting of set of 55 cells of 2 volt, 200ah conforming t o rdso spec. rdso/pe/spec/tl/0040 (rev.2) 2021. lead acid (tubular positive and pasted negative p lates) stationary batteries 110v 200ah (comprising 55 cells of 2v each) capacity at 10hrs. rate of disc harge assembled in ppcp container with intercell connectors, inter row connectors, inter tier connecto rs, stainless steel fasteners, micro porous vent plug, electrolyte level indicators, and porcelain cells ins ulators in dry and uncharged condition and electrolyte, user manual, routine and acceptance test rep orts as per rdso spec. to be supplied along with battery test. maintenance accessories and electrolyt e. - warranty period: 30 months after the date of delivery -quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitt ed: max 8 lacs

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16154385
Location : kullu , himachal pradesh
Source : GEM Tenders
LIVE TENDER
tender for outdoor ptp wireless radio , high gain external directional antenna compatible with ptp radio , poe injector unit compatible with wireless radio , outdoor ethernet rj45 surge protection device , industrial serial rs232 or rs485 to ethernet converter , 8 port l2 managed switch , online ups 1 kva , surge protection device for ups , gi pole 5 ft , mast 20 ft , earthing system , lightning protection system la rod , insulator for la , insulated earthing wire , armoured power cable 2.5 sq mm , armoured optical fiber cable , armoured cat6 cable , outdoor hdpe pipe for cable protection , weatherproof equipment enclosure outdoor , indoor 6u rack , mounting, cabling and accessories , installation testing and commissioning , camc for 1st year for items s. no. 1 to 21 at the rate of 6.5 percent per year , camc for 2nd year for items s. no. 1 to 21 at the rate of 7.5 percent per year , camc for 3rd year for items s. no. 1 to 21 at the rate of 8.5 percent per year , unarmoured power cable 1.5 sq mm , unarmoured cat6 cable , installation, testing and commissioning , camc for 1st year for items s. no. 1 to 14 at the rate of 6.5 percent per year , camc for 2nd year for items s. no. 1 to 14 at the rate of 7.5 percent per year , camc for 3rd year for items s. no. 1 to 14 at the rate of 8.5 percent per year , high-gain external directional antenna compatible with ptp radio , 16 port l2 managed switch , camc for 1st year for items s. no. 1 to 17 at the rate of 6.5 percent per year , camc for 2nd year for items s. no. 1 to 18 at the rate of 7.5 percent per year , camc for 3rd year for items s. no. 1 to 19 at the rate of 8.5 percent per year , industrial serial rs232 rs485 to ethernet converter , 24-port l2 managed switch , online ups 2 kva , camc for 1st year for items s. no. 1 to 22 at the rate of 6.5 percent per year , camc for 2nd year for items s. no. 1 to 22 at the rate of 7.5 percent per year , camc for 3rd year for items s. no. 1 to 22 at the rate of 8.5 percent per year, supply installation testing and commissioning of ptp rf link at 04 airports of northern region, supply of industrial-grade outdoor point-to-point wireless radio set comprising two radios for establishing high-speed ethernet connectivity over long distances. suitable for outdoor operation with ip-rated enclosure and poe support as per technical specifications., supply of high-gain outdoor directional antenna compatible with the supplied ptp wireless radio for extended range and stable wireless communication, complete with mounting hardware as per technical specifications., supply of ieee 802.3af/at compliant power over ethernet (poe) injector for powering the outdoor wireless radio and carrying data over a single ethernet cable as per technical specifications., supply of outdoor-rated ethernet/rj45 surge protection device for protecting network equipment against lightning-induced surges and transient voltages as per technical specifications., supply of industrial-grade serial (rs232/rs485) to ethernet converter suitable for reliable communication in industrial environments as per technical specifications., supply of 8-port layer-2 managed gigabit ethernet switch with vlan, qos, stp/rstp and snmp management features as per technical specifications., supply of 1 kva true online double-conversion ups complete with maintenance-free batteries and accessories as per technical specifications., supply of surge protection device suitable for ups input power protection against electrical surges and lightning transients as per technical specifications., supply of 5-foot galvanized iron (gi) pole complete with mounting accessories as per technical specifications., supply of 20-foot galvanized steel mast complete with clamps and mounting hardware as per technical specifications., supply of complete maintenance-free earthing system with all accessories as per technical specifications., supply of lightning arrestor rod complete with mounting accessories for outdoor installations as per technical specifications., supply of outdoor-grade insulator suitable for lightning arrestor installation as per technical specifications., supply of pvc insulated copper earthing wire of suitable size for grounding applications as per technical specifications., supply of 2.5 sq.mm armoured copper power cable suitable for outdoor installations as per technical specifications., supply of outdoor armoured single-mode optical fiber cable for communication applications as per technical specifications., supply of outdoor uv-resistant armoured cat6 ethernet cable as per technical specifications., supply of uv-resistant hdpe pipe for protection of underground and outdoor cables as per technical specifications., supply of outdoor ip65 or higher weatherproof equipment enclosure complete with mounting accessories as per technical specifications., supply of 6u wall-mounted network rack complete with accessories as per technical specifications., supply of all mounting hardware, cabling materials, connectors, fasteners and accessories required for complete installation., installation, testing, configuration and commissioning of the supplied equipment for complete operational readiness., comprehensive annual maintenance contract (camc) for the first year covering all supplied equipment as specified at the rate of 6.5 % per station per year after warranty period., comprehensive annual maintenance contract (camc) for the second year covering all supplied equipment as specified at the rate of 7.5 % per station per year after warranty period., comprehensive annual maintenance contract (camc) for the third year covering all supplied equipment as specified at the rate of 8.5 % per station per year after warranty period., supply of industrial-grade outdoor point-to-point wireless radio set comprising two radios for establishing high-speed ethernet connectivity over long distances. suitable for outdoor operation with ip-rated enclosure and poe support as per technical specifications., supply of lightning arrestor rod complete with mounting accessories for outdoor installations as per technical specifications., supply of 1.5 sq.mm unarmoured copper power cable suitable for indoor applications as per technical specifications., supply of indoor cat6 utp ethernet cable conforming to industry standards as per technical specifications., supply of all mounting hardware, cabling materials, connectors, fasteners and accessories required for complete installation as per technical specifications., comprehensive annual maintenance contract (camc) for the first year covering all supplied equipment as specified at the rate of 6.5 % per station per year after warranty period., comprehensive annual maintenance contract (camc) for the third year covering all supplied equipment as specified at the rate of 8.5 % per station per year after warranty period., supply of 16-port layer-2 managed gigabit ethernet switch with advanced switching and network management features as per technical specifications., comprehensive annual maintenance contract (camc) for the second year covering all supplied equipment as specified at the rate of 7.5 % per station per year after warranty period., supply of 24-port layer-2 managed gigabit ethernet switch with advanced layer-2 networking features as per technical specifications., supply of 2 kva true online double-conversion ups complete with maintenance-free batteries and accessories as per technical specifications., supply of 2.5 sq.mm armoured copper power cable suitable for outdoor installations as per technical specifications., supply of outdoor armoured single-mode optical fiber cable for communication applications as per technical specifications., supply of outdoor uv-resistant armoured cat6 ethernet cable as per technical specifications., supply of uv-resistant hdpe pipe for protection of underground and outdoor cables as per technical specifications., supply of outdoor ip65 or higher weatherproof equipment enclosure complete with mounting accessories as per technical specifications.

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Insulator Testing. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Insulator Testing sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Insulator Testing Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Insulator Testing, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Insulator Testing Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Insulator Testing Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Insulator Testing.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Insulator Testing depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Insulator Testing Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Insulator Testing bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Insulator Testing. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Insulator Testing, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Insulator Testing, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Insulator Testing?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Insulator Testing tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Insulator Testing?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Insulator Testing, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Insulator Testing is declared L1 and is generally awarded the contract