Search Tenders
Filters
Reset All
Tender Status
T18 Ref No
All States
All Cities
All Agencies
Tender ID
Due Date
Tender Value
Tender Source (GeM, Cppp & Others)
Tender Type

5Latest Digital protection coupler Tenders List

Latest Digital protection coupler Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Digital protection coupler tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Digital protection coupler tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Digital protection coupler Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Digital protection coupler tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Digital protection coupler Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Digital protection coupler Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Digital protection coupler Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Digital protection coupler tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Digital protection coupler Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Digital protection coupler sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Digital protection coupler tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Digital protection coupler tenders.

Is EMD mandatory for all Digital protection coupler tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Digital protection coupler work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Digital protection coupler tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Digital protection coupler Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

Due Date
T18 Ref No : 16138029
Location : bangalore , karnataka
Source : GEM Tenders
tender for electrical equipment and other accessories requirement electrical equipments and accessories 1 , electrical equipments and accessories 2 , electrical equipments and accessories 3 , electrical equipments and accessories 4 , electrical equipments and accessories 5 , electrical equipments and accessories 6 , electrical equipments and accessories 7 , electrical equipments and accessories 8 , electrical equipments and accessories 9 , electrical equipments and accessories 10 , electrical equipments and accessories 11 , electrical equipments and accessories 12 , electrical equipments and accessories 13 , electrical equipments and accessories 14 , electrical equipments and accessories 15 , electrical equipments and accessories 16 , electrical equipments and accessories 17 , electrical equipments and accessories 18 , electrical equipments and accessories 19 , electrical equipments and accessories 20 , electrical equipments and accessories 21 , electrical equipments and accessories 22 , electrical equipments and accessories 23 , electrical equipments and accessories 24 , electrical equipments and accessories 25 , electrical equipments and accessories 26 , electrical equipments and accessories 27 , electrical equipments and accessories 28 , electrical equipments and accessories 29 , electrical equipments and accessories 30 , electrical equipments and accessories 31 , electrical equipments and accessories 32 , electrical equipments and accessories 33 , electrical equipments and accessories 34 , electrical equipments and accessories 35 , electrical equipments and accessories 36 , electrical equipments and accessories 37 , electrical equipments and accessories 38 , electrical equipments and accessories 39 , electrical equipments and accessories 40 , electrical equipments and accessories 41 , electrical equipments and accessories 42 , electrical equipments and accessories 43 , electrical equipments and accessories 44 , electrical equipments and accessories 45 , electrical equipments and accessories 46 , electrical equipments and accessories 47 , electrical equipments and accessories 48 , electrical equipments and accessories 49 , electrical equipments and accessories 50 , electrical equipments and accessories 51 , electrical equipments and accessories 52 , electrical equipments and accessories 53 , electrical equipments and accessories 54 , electrical equipments and accessories 55 , electrical equipments and accessories 56 , electrical equipments and accessories 57 , electrical equipments and accessories 58 , electrical equipments and accessories 59 , electrical equipments and accessories 60 , electrical equipments and accessories 61 , electrical equipments and accessories 62 , electrical equipments and accessories 63 , electrical equipments and accessories 64 , electrical equipments and accessories 65 , electrical equipments and accessories 66 , electrical equipments and accessories 67 , electrical equipments and accessories 68 , electrical equipments and accessories 69 , electrical equipments and accessories 70 , electrical equipments and accessories 71 , electrical equipments and accessories 72 , electrical equipments and accessories 73 , electrical equipments and accessories 74 , electrical equipments and accessories 75 , electrical equipments and accessories 76 , electrical equipments and accessories 77 , electrical equipments and accessories 78 , electrical equipments and accessories 79 , electrical equipments and accessories 80 , electrical equipments and accessories 81 , electrical equipments and accessories 82 , electrical equipments and accessories 83 , electrical equipments and accessories 84 , electrical equipments and accessories 85 , electrical equipments and accessories 86 , electrical equipments and accessories 87 , electrical equipments and accessories 88 , electrical equipments and accessories 89 , electrical equipments and accessories 90 , electrical equipments and accessories 91 , electrical equipments and accessories 92 , electrical equipments and accessories 93 , electrical equipments and accessories 94 , electrical equipments and accessories 95 , electrical equipments and accessories 96 , electrical equipments and accessories 97 , electrical equipments and accessories 98 , electrical equipments and accessories 99 , electrical equipments and accessories 100 , electrical equipments and accessories 101 , electrical equipments and accessories 102 , electrical equipments and accessories 103 , electrical equipments and accessories 104 , electrical equipments and accessories 105 , electrical equipments and accessories 106 , electrical equipments and accessories 107 , electrical equipments and accessories 108 , electrical equipments and accessories 109 , electrical equipments and accessories 110 , electrical equipments and accessories 111 , electrical equipments and accessories 112 , electrical equipments and accessories 113 , electrical equipments and accessories 114 , electrical equipments and accessories 115 , electrical equipments and accessories 116 , electrical equipments and accessories 117 , electrical equipments and accessories 118 , electrical equipments and accessories 119 , electrical equipments and accessories 120 , electrical equipments and accessories 121 , electrical equipments and accessories 122 , electrical equipments and accessories 123 , electrical equipments and, electrical equipment and other accessories requirement, 1.5 sq.mm copper wire, 2.5 sq.mm copper wire, 4 sq.mm copper wire, 3c x 2.5 sq.mm copper cable, 4c x 4 sq.mm copper cable, pin type lugs 1.5 sqmm 200 nos. in one packet, pin type lugs 2.5 sqmm 200 nos. in one packet, pin type lugs 4 sqmm 200 nos. in one packet, pin type lugs 6 sqmm 200 nos. in one packet, pin type lugs 10 sqmm 100 nos. in one packet, pin type lugs 16 sqmm 100 nos. in one packet, pin type lugs 25 sqmm 100 nos. in one packet, ring type lugs 2.5 sqmm -e 6.0 200 nos. in one packet, ring type lugs 4 sqmm e 6.0 200 nos. in one packet, ring type lugs 6 sqmm -e 8.0 200 nos. in one packet, ring type 10 sqmm e 8.0 100 nos. in one packet, ring type 16 sqmm e 8.0 100 nos in one packet, ring type lugs 25 sqmm e 8.0 50 nos. in one packet, u type 1.0 sqmm e 3.0 200 nos. in one packet, u type lugs 2.5 sqmm - e 3.5 200 nos. in one packet, snap on terminal lugs 2.5 sqmm 200 nos. in one packet, snap on terminal lugs 4 sqmm 200 nos. in one packet, 19x20mm casing caping, 25x20mm casing caping, 50x50mm casing caping, 25mm dia hms conduit, 20mm dia hms conduit, 25mm dia 4 way pvc junction box, 20mm dia 4 way pvc junction box, 25mm dia pvc bend, 20mm dia pvc bend, 25mm dia coupler, 20mm dia coupler, recess mount led with 600x600x15 mm l x b square fitting, 22-26w led luminaire circular type, 100 watt led flood light, oscillating type pedestrial fan, wall mounted fan, exhaust fan pvc, ceiling fan, 5a or 6a plug top, 15 or 16a plug top, 6a mcb single pole, 10a mcb single pole, 16a mcb single pole, 25a mcb single pole, 20a mcb double pole, 25a mcb double pole, 32a mcb double pole, 25a mcb three pole, 32a mcb three pole, 40a mcb four pole, 63a mcb four pole, 25a, 30ma elcb, 40a 30ma elcb, 25a 100ma elcb, 40a 100ma elcb, cable manager, 100mm cable zip tie, 150mm cable zip tie, 200mm cable zip tie, 250mm cable zip tie, 300mm cable zip tie, digital timer switch with following specifications, ac axial fans, transformer silica gel, 0.5 inch pop wooden screws, 1 inch pop wooden screws, 1.5 inch pop wooden screws, 2 inch pop wooden screws, 3 inch pop wooden screws, ss nails 1.5 inch, wooden plug teak wood pack of 100 nos, hammer drilling bit, electrical wiring spring, 1-2 module metal flush box, 3 module metal flush box, 4 module metal flush box, 6 module metal flush box, 8 module metal flush box, 32amps 1p plus n plus e industrial socket, 32amps 1p plus n plus e industrial plug, 6a multipin adapter, 1.5mfd capacitors for fans or exhausts, 2.5mfd capacitors for fans capacitance, metal cutting wheels, wall cutting wheels, surprecision din rail, 8mm x 100mm screws closed hook anchor fastner bolts, 10mm x 100mm screws closed hook anchor fastner bolts, 32a 4 way bakelite connector strip, 20mm bi-meteal hole saw cutter part no 2609255601, 25mm bi-meteal hole saw cutter part no 2609255603, 32mm bi-meteal hole saw cutter part no2609255605, 38mm bi-meteal hole saw cutter part no 260925560, 18w zapper uv lights, gi earth wire 8 swg, selector switch am, panel indication lamp, flush type pushbutton with no block, emergency push button actuators, control contactor, phase failure plus overload protection relay, surge protection device, panel locker, 50w street light fitting, single phase preventer, 220v ac buzzer warning indicator, 20-22w led tube with inbuilt drive, 9-10w plc led bulb with inbuilt driver, 10-12w plc led bulb with inbuilt driver, 18w pl-l led light with inbuilt driver, 9w pl-l led light with inbuilt driver, 9w led bulb with inbuilt driver, 14-15w led bulb with inbuilt driver, 20-22w led light with inbuilt driver, 10w led light with inbuilt driver, 30-35w led light with inbuilt driver, 50w led circuit board with suitable driver, 15w led panel light with suitable driver, 9w led panel light with suitable driver, 1000w halogen tube, pendent bulb holder suitable for b22lamps, angle lamp holder suitable for b22lamps, ceiling lamp holder -suitable for b22lamps, philips xitanium 150w 0.7a 240v oem driver, electric water heater small safety valve, electric water heater thermostate, auto cut off electric water thermostate, instatnt geyse coil, 3kw geyse coil, 6a hrc fuse, 20a hrc fuse, 10a cartridge fuse, crompton fan canopy, 6a socket, 6a universal socket, 16a socket, 6a switch, 16a switch, 6a bell push, 2 module fan regulator, 2 module face plate, 3 module face plate, 4 module face plate, 6 module face plate, ht insulation tape, ding dong calling bell, 32a industrial ac box with plug, solar connecters, 16a socket hi-fi, 6a socket hi-fi, 16a switch hi-fi, 6a switch hi-fi, spike gaurd - model gm 3061, compound rubber tape, crc electrical contact cleaner, wd-40 rust cleaner, baniyan cloth waste, hacksaw blades, hammer chisel set, carbon sensors for water level controller, pvc cable clip, pvc cable clip 20mm, pvc cable clip 10mm, 40mm hdpe pipe end cap, sillicone sealent 280ml, sillicone sealent gun
T18 Ref No : 16517818
Location : imphal , manipur
Source : GEM Tenders
corrigendum tender for refer soq, sh-i, item no. 1a - supply of bi-directional elevated high intensity led runway edge light fixture. a. clear and yellow , refer soq, sh-i, item no. 1- supply of bi- directional elevated high intensity led runway edge light fixure. b. clear and clear , refer soq, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting. , refer soq, sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting , refer soq, sh-i, item no. 4a. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. a.clear and yellow , refer soq, sh-i, item no. 4b. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. b. clear and clear , refer soq, sh-i, item no. 5a. supply of following rating 5000v, 50hz series isolating transformers. a. 45 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers. b. 100 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator. a. 7.5kw , refer soq, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator. b. 2.5 kw , refer soq, sh-i, item no. 7a. supply of following 5kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. a. 6 sq.mm , refer soq, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. b. 2c x 6 sq.mm , refer soq, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle. a. 6 sq.mm , refer soq, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63. a. 40mm dia , refer soq, sh-ii, item no. 1. itc of ccr including interconnection of existing power cable and control cable within 50m lead , refer soq, sh-ii, item no. 2a. itc of fitting type on the existing transformer housing boxes. a. hirl elevated type , refer soq, sh-ii, item no. 2b. itc of fitting type on the existing transformer housing boxes. b. sapl , refer soq, sh-ii, item no. 2c. itc of fitting type on the existing transformer housing boxes. c. threshold , refer soq, sh-ii, item no. 2d. itc of fitting type on the existing transformer housing boxes. d. end light , refer soq, sh-ii, item no. 2e. itc of fitting type on the existing transformer housing boxes. e. inset , refer soq, sh-ii, item no. 3. itc of airfield lighting cable. , refer soq, sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable. a. 6 sq.mm , refer soq, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade , refer soq, sh-ii, item no. 6. laying, jointing and coomissioning of 40 mm dia hdpe pipe. , refer soq, sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate including transportation to aai store. , refer soq, sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc. including transportation to aai store., supply installation testing and commissioning of led rwy elevated edgelight and cat i and sapl and inset fitting and iso transformer and ccr, sh-i item no. 1a. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. a. clear and yellow, sh-i, item no. 1b. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. b. clear and clear, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6a current, colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 4a. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. a. clear and yellow, sh-i, item no. 4b. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. b. clear and clear, sh-i, item no. 5a. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. a. 45 watt, 6.6a by 6.6a, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. b. 100 watt, 6.6a by 6.6a, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. a. 7.5 kw, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. b. 2.5 kw, sh-i, item no. 7a. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. a. 6 sq.mm, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. b. 2c x 6 sq.mm, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle of type i, class b primary connector kit with field attachment and suitable for 5 kv grade single core copper conductor, copper braided, xlpe insulated pe outer sheathed shielded cable, complete as required as per technical specifications. a. 6 sq.mm, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63 confirming to is 4984 2016 with latest amendment, complete with all associated accessories like couplers, bends, tee etc. complete as per site requirement as per technical specifications. a. 40 mm dia, sh-ii, item no. 1. installation testing and commissioning of ccr including interconnection of existing power cable and control cable within 50m lead and making foundation, for operating with the existing airfield lighting control and monitoring system alcms complete as required as per technical specifications., sh-ii, item no. 2a. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. a. hirl elevated type, sh-ii, item no. 2b. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. b. sapl, sh-ii, item no. 2c. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. c. threshold, sh-ii, item no. 2d. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. d. end light, sh-ii, item no. 2e. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. e. end light, sh-ii, item no. 3. installation, testing and commissioning of the undermentioned airfield lighting fixtures complete with base plate, transformer, support, interconnection, end termination earthing including ensuring original elevation of the fitting x-y-z of the fitting through checking or of measurement of the level or alignment with dgps and total station etc. as required., sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable including filling the gap with water sealent material, applying pvc insulation tape of bell or permacel etc. complete as required. a. 6 sq.mm, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade upto cable of size upto 25 sq.mm in existing pipe etc. as reqd., sh-ii, item no. 6. laying, jointing and commissioning of 40 mm dia hdpe pipe pn6 grade pe 63 confirming to is 4984-2016 by trenchless method by carrying out horizontal directional drilling hdd along or across various fexible or rigid pavement like runway or taxiway and service road or drain etc. at various site or location as per the drawing approved by aai including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct of various size as per the design invert level and providing baricades and necessary warning signal lights, restoration of paved surfaces or utilities etc. as required. 40 mm., sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required., sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required including measurment of the existing level of each fitting with calibrated dgps and total station by a certified survery etc, as required before dismentalling. including transportation to aai store as required.
T18 Ref No : 16239961
Location : pune , maharashtra
Source : GEM Tenders
tender for providing and fixing of 5 or 6 amps piano switch , providing and fixing of 15 or 16 amps piano switch , providing and fixing of 3 pin 5 or 6 amps piano socket , providing and fixing of 6 pin 15 or 16 amps piano socket , providing and fixing of 100watt step type electronic fan regulator , providing and fixing of call bell or buzzer , providing and fixing of 2.5mfd capacitor , providing and fixing of 36watt fl. tube light , providing and fixing of 20w aluminium led batten tubelight , repairing of ceiling fan upto 1400mm sweep , repairing of wall fan upto 450mm sweep , repairing of exhaust fan upto 450mm sweep , providing and fixing of 1400mm sweep, copper wound ceiling fan , replacement of faulty street light with new 45w high performance led street light , providing and fixing of 50mm dia heavy duty gun metal gate valve , painting of 16nos. compound light pole, 3nos. water pumps , providing and fixing of response indicator , providing and fixing of hammer and chain , rectification of fault in existing fd and fa system , replacement of hose pipe alongwith horn , providing and fixing of 0 to 100a range 96 sq.mm size ac ammeter , providing and fixing of 0 to 12kv range 96 sq.mm size ac voltmeter , providing and fixing of red or yellow or blue colour led indicating lamp , providing and fixing of ct pt operated 3 phase 3 wire or 4 wire ht trivector meter , providing and fixing of ammeter selecter switch , providing and fixing of 11kv ht potential transformer of 11kv by 110v ratio , servicing of 11kv, 400amp oil circuit breaker , providing and fixing of 11kv ht current transformer of 100 by 50 by 5 ratio , attending oil leakage of 500kva transformer , servicing and repairing of 800a to 1250a acb , providing and fixing of red or yellow or green colour led indicating lamp , providing and fixing of blue colour led indicating lamp , providing and fixing of 0 to 600v range ac voltmeter of 96 sq.mm size , providing and fixing of 6a vss with control wiring etc. , providing and fixing of under voltage coil suitable for 800a or 1250a acb , providing and fixing of shunt release coil suitable for 800a or 1250a acb , providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link , providing and fixing of 25kvar md xl type 440v capacitor , providing and fixing of 5kvar md xl type 440v capacitor , providing and fixing of 10kvar md xl type 440v capacitor , repairing of apfc relay of 100kvar capacitor panel , repairing of electrical and mechanical interlocking , providing and fixing of digital rpm cum hour meter , providing and fixing of 24v, 10a smps battery charger , providing and fixing of 0 to 600a range ac ammeter of 96 sq.mm size , providing and fixing of emmergency stop switch , attending diesel leakage from 380kva ea set , repairing of existing faulty control circuit card of 380 kva dg set , providing and fixing of 80 to 100 mfd starting capacitor , providing and fixing of 36 to 50 mfd running capacitor , providing and fixing of 4 to 6 mfd capacitor , providing and fixing of contactor relay , providing and fixing of starting relay , providing and fixing of thermostat , providing and fixing of selector switch in window ac , providing and fixing of remote for 1.5tr or 2tr split ac , supplying and charging of r 22 refrigerant gas, ocm of ems at bajirao rd pune sh attending defects in scope of satyam enterprises at risk and cost, providing and fixing of 5 or 6 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 15 or 16 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 3 pin 5 or 6 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 6 pin 15 or 16 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 100watt step type electronic fan regulator on existing switchboard complete etc. as reqd., providing and fixing of call bell or buzzer suitable for 230v, 1phase ac supply complete etc. as reqd., providing and fixing of 2.5mfd capacitor in existing fan complete etc. as reqd., providing and fixing of 36watt fluorescent tube light complete etc. as reqd., providing and fixing of 20w aluminium led batten tubelight with aluminium heat sink, 6500k cool day light, 2000 lumen for commercial use including testing commissioning etc complete as reqd, repairing of ceiling fan upto 1400mm sweep including removing, servicing, rewinding, varnishing, replacement of bearing, to and fro transportation, reinstallation testing etc complete as reqd., repairing of wall fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, repairing of exhaust fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 1400mm sweep, 80watt, 280 to 370rpm, copper wound ceiling fan incl. 3nos. blade, 30cm long down rod, 2no. canopies etc. suitable for 230v, 1ph ac supply etc. complete as reqd, replacement of faulty street light with new 45w high performance led street light having ip66 protection street optic lens including 1.5sqmm copper wiring from pole box to fitting etc complete as reqd, providing and fixing of 50mm dia heavy duty gun metal gate valve in discharge water line of pump set etc complete as required., painting of 16nos. compound light pole, 2nos. 5hp, 1no. 3hp capacity water pumps incl. surface cleaning and applying one or more coats of approved shade synthetic enamel paint complete etc. as reqd., providing and fixing of response indicator with metallic cover, 2nos. leds on existing surface or recess ms box including connection testing commissioning etc complete as required., providing and fixing of hammer and chain on existing surface or recess manual call point box etc complete as required., rectification of fault in existing fd and fa system incl. checking of control wiring, repairing of control cards in mcp or lcp, hooters, detectors, ri, pill box, pa system etc complete as required., replacement of hose pipe alongwith horn of 4.5kg co2 type fire extinguisher etc complete as required., providing and fixing of 0 to 100a range 144 sq.mm size suitable for ct ratio 100 by 50 by 5 ac ammeter in 11kv ht panel etc. complete as reqd., providing and fixing of 0 to 12kv range 144 sq.mm size suitable for pt ratio 11kv by 110v ac voltmeter in 11kv ht panel etc. complete as reqd., providing and fixing of red or yellow or blue colour led indicating lamp suitable for 110v ac supply in 11kv ht panel including connection, testing, commissioning etc. as reqd., providing and fixing of ct pt operated 3 phase 3 wire or 4 wire ht trivector meter in 11kv ht panel etc. complete as reqd., providing and fixing of ammeter selecter switch with control wiring in 11kv ht panel etc. complete as reqd., providing and fixing of 11kv ht potential transformer of 11kv by 110v ratio in 11kv ht panel etc. complete as reqd., servicing of 11kv, 400amp oil circuit breaker incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of 11kv ht current transformer of 100 by 50 by 5 ratio in 11kv ht panel etc. complete as reqd., attending oil leakage through ht and lt bushing, oil tank of 500kva transformer, side glass incl. replacement of gasket etc complete as reqd, servicing and repairing of 800a to 1250a acb incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of red or yellow or green colour led indicating lamp for mv panel including connection, testing, commissioning etc. as reqd., providing and fixing of blue colour led indicating lamp for mv panel including connection, testing, commissioning etc. as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in mv panel including connection testing commissioning complete etc. as reqd., providing and fixing of 3 pole and off 6a, voltmeter selector switch with control wiring in mv panel etc. complete as reqd., providing and fixing of under voltage coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of shunt release coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 25kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 5kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 10kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., repairing of apfc relay of 100kvar capacitor panel including calibration, testing on load and auto mode operation, testing, commissioning etc. as reqd., repairing of electrical and mechanical interlocking between 4nos. incomers and 1no. bus coupler including replacing mechanical locks, wiring, connection, testing, commissioning etc. as reqd., providing and fixing of digital rpm cum hour meter suitable for existing 380kva ea set including connection testing commissioning etc. complete as reqd., providing and fixing of 24v, 10a smps battery charger in existing existing 380kva ea set control panel including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in 380kva ea set control panel including connection testing commissioning complete etc. as reqd., providing and fixing of emmergency stop switch on 380kva ea set including connection testing commissioning complete etc. as reqd., attending diesel leakage in fuel tank, fuel valves, fuel hoses etc. of 380kva ea set with suitable means complete etc. as reqd., repairing of existing faulty control circuit card of volvo penta make tad1230d model 380 kva dg set including to and fro transportation and reinstallation, testing on load etc. complete as reqd., providing and fixing of 80 to 100 mfd starting capacitor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 36 to 50 mfd running capacitor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of 4 to 6 mfd capacitor for condenser fan motor in window or split ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of contactor relay in outdoor unit of split ac including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of starting relay in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of thermostat in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of selector switch in window ac unit including wiring, connection testing commissioning etc. complete as reqd., providing and fixing of remote for 1.5tr or 2tr split ac unit including testing etc. complete as reqd., supplying and charging of r 22 refrigerant gas in existing window or split ac unit refrigerant circuit etc complete as required.

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16343707
Location : imphal , manipur
Source : GEM Tenders
tender for refer soq, sh-i, item no. 1a - supply of bi-directional elevated high intensity led runway edge light fixture. a. clear and yellow , refer soq, sh-i, item no. 1- supply of bi- directional elevated high intensity led runway edge light fixure. b. clear and clear , refer soq, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting. , refer soq, sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting , refer soq, sh-i, item no. 4a. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. a.clear and yellow , refer soq, sh-i, item no. 4b. supply of high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100w. b. clear and clear , refer soq, sh-i, item no. 5a. supply of following rating 5000v, 50hz series isolating transformers. a. 45 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers. b. 100 watt, 6.6a by 6.6a , refer soq, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator. a. 7.5kw , refer soq, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator. b. 2.5 kw , refer soq, sh-i, item no. 7a. supply of following 5kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. a. 6 sq.mm , refer soq, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable. b. 2c x 6 sq.mm , refer soq, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle. a. 6 sq.mm , refer soq, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63. a. 40mm dia , refer soq, sh-ii, item no. 1. itc of ccr including interconnection of existing power cable and control cable within 50m lead , refer soq, sh-ii, item no. 2a. itc of fitting type on the existing transformer housing boxes. a. hirl elevated type , refer soq, sh-ii, item no. 2b. itc of fitting type on the existing transformer housing boxes. b. sapl , refer soq, sh-ii, item no. 2c. itc of fitting type on the existing transformer housing boxes. c. threshold , refer soq, sh-ii, item no. 2d. itc of fitting type on the existing transformer housing boxes. d. end light , refer soq, sh-ii, item no. 2e. itc of fitting type on the existing transformer housing boxes. e. inset , refer soq, sh-ii, item no. 3. itc of airfield lighting cable. , refer soq, sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable. a. 6 sq.mm , refer soq, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade , refer soq, sh-ii, item no. 6. laying, jointing and coomissioning of 40 mm dia hdpe pipe. , refer soq, sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate including transportation to aai store. , refer soq, sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc. including transportation to aai store., supply installation testing and commissioning of led rwy elevated edgelight and cat i and sapl and inset fitting and iso transformer and ccr, sh-i item no. 1a. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. a. clear and yellow, sh-i, item no. 1b. supply of bi-directional elevated high intensity led runway edge light fixture with refocused led module or led modules up to 45 w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with clear glass at each side to cover the led module for main beam. each light fitting should have breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring & plain washers and other accessories etc. and should meet latest icao or faa compliance requirement. b. clear and clear, sh-i, item no. 2. supply of unidirectional elevated high intensity led cat 1 approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6 a current. colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 3. supply of unidirectional elevated high intensity led simple approach light fitting with pre-focused led module or led modules up to 45w suitable for series circuit 2.8a to 6.6a current, colours should be emitted from the leds. brilliancy shall change on all steps as per current provided by ccr and the intensity ratio on all steps shall be as per faa standard. fitting shall be provided with front glass before the led module for main beam. the light fitting should have provision for vertical beam adjustment from 0 deg. to 25 deg. with measuring scale and horizontal beam adjustment at each side from 0 deg. to 20 deg. with measuring scale. fixture should be supplied with breakable coupling, gaskets, two pin secondary lead plug suitable for connection with isolating transformer, base plate with 6 nos. m-10 stainless steel bolts, spring and plain washers and other accessories etc. fixture should meet latest icao or faa compliance requirement., sh-i, item no. 4a. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. a. clear and yellow, sh-i, item no. 4b. supply of faa certified or compliant model, inset, bidirectional, suitable for icao cat-i all weather operation, high intensity runway edge light for icao aviation visual aids requirements complete with led module or led modules up to 100 w with integral driver, fail-open technology and electronics suitable for 2.8 to 6.6 amps current with connected heat resistant accessories, prism assembly, optical assembly, o-ring seal, pressure relief test plug, hardware, lenses cable lead with plug and all standard accessories and ready for site installation on existing cement or asphaltic area and compatible to existing alcms or ilcms conforming to latest icao or car requirement as per technical specifications complete as required. b. clear and clear, sh-i, item no. 5a. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. a. 45 watt, 6.6a by 6.6a, sh-i, item no. 5b. supply of following rating 5000v, 50 hz series isolating transformers encapsulated in black cross linked polychloroprene compound like tpe or tpr or tpv with primary and secondary connections suitable to be operated confirming to specification as required suitable for above mentioned fittings for following applications and compatible to use on alcms. b. 100 watt, 6.6a by 6.6a, sh-i, item no. 6a. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. a. 7.5 kw, sh-i, item no. 6b. supply of indoor type air cooled constant current regulator ccr of micro processor controlled, thyristor type suitable for operation on single phase 230v by 2-phase 400v ac + pe + or - 10 per cent, 50 hz input ac supply with 5 steps variation of current output i.e. 2.8, 3.4, 4.0, 5.2 and 6.6 amp and able to communicate with pc or plc controlled system with digital output ammeter of 0-10 amps, over current, over voltage, open circuit and earth fault protection and earth leakage meter, two stage earth leakage detector, positive back indication equipments, hours run counter, lcd display complete as required for the following rating and confirm to specifications enclosed and suitable for operation on the existing airfield lighting control and monitoring system alcms with communication, local and remote control and monitoring even and data recording and history keeping etc. complete as required as per technical specifications. b. 2.5 kw, sh-i, item no. 7a. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. a. 6 sq.mm, sh-i, item no. 7b. supply of following 5 kv grade single core, stranded copper conductor pvc insulated and pvc sheathed underground airfield lighting cable generally confirming to is 1554 part ii - 1981 with up-to-date amendments as required. b. 2c x 6 sq.mm, sh-i, item no. 8a. supply of following sizes 5 kv grade dry type plug and receptacle of type i, class b primary connector kit with field attachment and suitable for 5 kv grade single core copper conductor, copper braided, xlpe insulated pe outer sheathed shielded cable, complete as required as per technical specifications. a. 6 sq.mm, sh-i, item no. 9a. supply of high-density polyethylene hdpe pipe with pressure rating pn6 grade pe 63 confirming to is 4984 2016 with latest amendment, complete with all associated accessories like couplers, bends, tee etc. complete as per site requirement as per technical specifications. a. 40 mm dia, sh-ii, item no. 1. installation testing and commissioning of ccr including interconnection of existing power cable and control cable within 50m lead and making foundation, for operating with the existing airfield lighting control and monitoring system alcms complete as required as per technical specifications., sh-ii, item no. 2a. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. a. hirl elevated type, sh-ii, item no. 2b. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. b. sapl, sh-ii, item no. 2c. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. c. threshold, sh-ii, item no. 2d. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. d. end light, sh-ii, item no. 2e. installation, testing and commissioning of following fitting type on the existing transformer housing boxes including installation of transformer, lens, lamps gasket, nut bolts, lens holding clamp and other accessories including alignment, levelling, isolating transformer, connection, earth connection etc. all complete. e. end light, sh-ii, item no. 3. installation, testing and commissioning of the undermentioned airfield lighting fixtures complete with base plate, transformer, support, interconnection, end termination earthing including ensuring original elevation of the fitting x-y-z of the fitting through checking or of measurement of the level or alignment with dgps and total station etc. as required., sh-ii, item no. 4a. making field connections by crimping 6 by 16 sq.mm plug and receptable with the exisitng 16 by 6 sq.mm single core pvc insulated copper conductor cable including filling the gap with water sealent material, applying pvc insulation tape of bell or permacel etc. complete as required. a. 6 sq.mm, sh-ii, item no. 5. laying of one no. pvc insulated and sheathed cu condutor afl cable of 5kv grade upto cable of size upto 25 sq.mm in existing pipe etc. as reqd., sh-ii, item no. 6. laying, jointing and commissioning of 40 mm dia hdpe pipe pn6 grade pe 63 confirming to is 4984-2016 by trenchless method by carrying out horizontal directional drilling hdd along or across various fexible or rigid pavement like runway or taxiway and service road or drain etc. at various site or location as per the drawing approved by aai including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct of various size as per the design invert level and providing baricades and necessary warning signal lights, restoration of paved surfaces or utilities etc. as required. 40 mm., sh-ii, item no. 7. dismantling of existing elevated type, hirl, sapl, inset fittings along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required., sh-ii, item no. 8. dismantling of existing elevated type, cat-i, along with the base plate, disconnection of bi-pin lead, etc complete as required including transportation to aai store as required including measurment of the existing level of each fitting with calibrated dgps and total station by a certified survery etc, as required before dismentalling. including transportation to aai store as required.
T18 Ref No : 16121822
Location : bardhaman , west bengal
Source : GEM Tenders
tender for supply laying testing and connecting xlpe sheathed pvc insulated screened pvc size 3.5 core 240 sqmm complete all as specified and as directed. , supply installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy sound level not more than 75db , m and l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth pit not less than 2.25mtr , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in soft loose soil complete all as specified and as directed. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified and as directed. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil complete all as specified and as directed. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable laid in trenches of 230mm , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable complete all as specified and as directed. , s and f galvanised iron pipe 80mm bore dia light grade for protection of ug cable laid in floors road crossing , s and f hdpe dwc double walled corrugated of diameter 90 mm including disconnection and connection of cable , material and labour for manufacturing installation testing and commissioning of factory made and tested cpri approved amf , m and l for surface excavation n.exc not exceeding 30 cm deep and averaging 15cm deep , m and l for hardcore using broken stone or boulders of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick , m and l for cement concrete in foundations filling and mass concrete type d2 1 4 8 , m and l for pcc 1 2 4 type b1 using 20mm grade aggregate as in coping for pole inclduing form work , m and l for excavating in post holes or similar holes each n exc 0.5 cu. m getting out returning filling in and ramming earth , s and f for steel work in tubular trusses cloumn purlin including special shaped washer nut bolt etc. , s and f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick , m and l for preparation of steel surfaces of any description over 10 cm , m and l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 , providing and laying at or near ground level factory made kerb stone of m25 grade , m and l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm , s and f 4pole 630 amp changeover switch with enclosure suitable for 415 v ac 3phase 4 wire , wrecking crow bar or claw bar as per is 706 (q3), supply, laying, testing and connecting xlpe sheathed,pvc insulated screened pvc bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 240 sqmm complete all as specified and as directed., supply, installation testing and commissioning of silent type diesel engine driven generating set with governing class g2 including sound reducing canopy (sound level not more than 75db at a distance of 1 mtr) 14 guage as per guidelines issued by central pollution control board (cpcb ivplus, 4plus), 415 volts, 3 phase, 50 hz supply complete, control panel suitable for giving an output of 250 kva and alternator of suitable capacity and rpm coupled with each other with flexible coupling mounted on anti vibration pads on foundation as recommended by manufacturer. the dg set shall comprise of self starter with batteries, turbocharger, water cooler and comprising all standard fittings, fixtures & all piping etc. as below (a) alternator directly coupled with engine and suitable to produce 415 volts, 3 phase, 4 wire system, 50 hz, 0.8 pf 1500 rpm of capacity 250 kva all as per is 13364 and upto date amendments with h class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball / roller bearing with damper winding in each pole, complete all as specified and directed. (b) engine water cooled diesel engine (cpcb norms iv compliance) developing 105 bhp having self start engine (including batteries with provision of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per oem) as per is 10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 rpm industrial type as per bs 649 or is 1601 with ai electronic governor suitable to regulate speed of dg set from no load to full load complete with fuel tank of capacity as per manufacturer s recommendation, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer muffiers etc. for continuous operation and standard accessories, sump pre heaters, cold start kit etc., m&l earthing complete with gi steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground, earth pit not less than 2.25mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by provision of 40mm bore gi pipe medium grade and including provision of concrete pit in pcc 1 2 4 type b 1 (using 20mm grade crushed stone aggregate) with 40mm thcik rcc (type b 1) cover reinforced with 8mm dia tmt bar both ways with 12mm dia round bar handle and frame of angle iron 25x25x3mm with lugs 02 nos and 20mm bore gi light grade watering pipe with funnel and wiremesh and filling common salt and charcol and test point with fixing arrangements and including necessary excavation in any type of soil, returning filling in and removing excavated soil to a distance of 50mtr from the site, complete all as shown on electrical plate no 3 of mes ssr part i and directed., excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil, complete all as specified and as directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed., removing excavated materials (soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point in soil, complete all as specified and as directed., m&l sand cushioning (dry) in trenches for protection of ug cables (below, above and around the ug cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (note for the purpose of payment, punned thickness of sand cushioning only shall be measured and paid)., m&l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable, complete all as specified and as directed., s&f galvanised iron pipe 80mm bore (dia) light grade for protection of ug cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and as directed., s & f hdpe dwc (double walled corrugated) of diameter 90 mm including disconnection and connection of cable near panel/oh for pipe fixing including joints complete all as directed., material and labour for manufacturing, installation testing and commissioning of factory made and tested, cpri approved amf panel for 250 kva dg set, indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 volts, 3 phase 4 wire 50hz ac supply system, conforming to is 5039, ip54 class protection and made of 3mm crca mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated al. bus bar 1000 amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for mccb with suitable capacity of al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments including necessary pcc in 1 2 4 type b1 using 20mm graded stone aggregate for platform of suitable size , prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following acessories incomer1 & 2 (main & dg) (a) busbars 1000a tpn 415volts 3phase 4 wire color coaded aluminium busbars 1 lot (b) mccb 630a fp edo 50ka microprocessor based ( o/c, s/c & e/f) release with motor, closing & shunt, aux. contact 4noplus4nc 2 nos. (c) amf relay (econ) 1 nos. (i) digital ammeter 1 nos. (ii) digital voltmeter 1 nos. (iii) ct 1000/5a cl1 10va 1 nos (iv) phase indication light red 230v ac 1 nos. (v) phase indication light yellow 230v ac 1 nos. (vi) phase indication light blue 230v ac 1 nos. (vii) indication lamp 22mm dia color red 240v ac (on) 2 nos. (viii) indication lamp 22mm dia color green 240v ac (off) 2 nos. (ix) indication lamp 22mm dia color amber 240v ac (trip) 2 nos. etc., m&l for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed., m&l for hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed., m&l for cement concrete in foundations, filling and mass concrete type d2 1 4 8 (using 40mm grade aggregate), m&l for pcc 1 2 4 type b1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed., m&l for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed., s & f for steel work in tubular trusses, cloumn, purlin including special shaped washer, nut, bolt etc. complete using erw or induction butt welded tubes conforming to i.s.1161 1979 grade st.240 complete all as specified., s&f prepainted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, m & l for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified, m&l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 156582006 of 60 mm thickness, m35 grade with grey cement and pigment all as specified and directed., providing and laying at or near ground level factory made kerb stone of m25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1 3 (1 cement 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed., m&l for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by engrincharge., s&f 4pole, 630 amp changeover switch with enclosure, suitable for 415 v ac, 3phase, 4wire, 50 hz system, for changeover between main supply and dg set. the switch shall be heavyduty, onload type conforming to is/iec 609473, with silver alloy contacts and adequate breaking capacity. the unit shall be mounted on a sturdy angle iron frame fixed over pcc block with necessary nuts, bolts and support structure. terminals shall be suitable for cable/busbar connection and provision for safe manual operation (or motorised operation, if required) shall be included complete with all accessories, mounting hardware all as specified and directed.

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Digital Protection Coupler. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Digital Protection Coupler sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Digital Protection Coupler Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Digital Protection Coupler, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Digital Protection Coupler Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Digital Protection Coupler Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Digital Protection Coupler.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Digital Protection Coupler depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Digital Protection Coupler Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Digital Protection Coupler bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Digital Protection Coupler. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Digital Protection Coupler, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Digital Protection Coupler, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Digital Protection Coupler?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Digital Protection Coupler tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Digital Protection Coupler?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Digital Protection Coupler, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Digital Protection Coupler is declared L1 and is generally awarded the contract