Filters By:

T18 Ref No
Keyword
State
City
Agency
Tender ID
Due Date
Tender Source
Tender Type

7Results forLatest Centrifugal fan repair Tenders List

Latest Centrifugal fan repair Tenders in India – Verified Leads & Real-Time Insights by Tender18

Finding the right Centrifugal fan repair tenders in India’s competitive e-procurement ecosystem requires more than just access—it demands accurate data, real-time monitoring, and expert analysis.

At Tender18 Infotech Private Limited, we bring deep industry experience in government procurement to help businesses identify, evaluate, and win Centrifugal fan repair tenders efficiently. With a centralized platform aggregating 1100+ live tenders, we provide a single, trusted source for opportunities from central, state, and PSU departments.


Real-Time Centrifugal fan repair Tender Intelligence & Monitoring

Our advanced dashboard delivers actionable insights and structured tender data, enabling you to make faster and smarter bidding decisions.

We categorize Centrifugal fan repair tenders into:

  • Supply Tenders – BOQs and specifications sourced from GeM and PSUs
  • Service Tenders – NITs and scope of work from CPPP and state portals
  • EPC Projects – Large-scale infrastructure tenders with financial and design data

✔ This structured approach ensures complete transparency and deeper bid analysis before submission.


Comprehensive Sources of Centrifugal fan repair Tenders

Tender18 acts as a centralized gateway by aggregating tenders from trusted and official sources:

  • Central Government Portals – CPPP, NIC, and Government e-Marketplace (GeM)
  • Railways & Transport – IREPS and Metro Rail projects
  • Power & Energy PSUs – NTPC, ONGC, NHPC, PowerGrid
  • Defense & Strategic Sectors – MES and DRDO tenders
  • State e-Procurement Portals – Gujarat, Maharashtra, Tamil Nadu, UP, and more

✔ Every listing is verified and regularly updated to maintain data accuracy and trust.


Step-by-Step Guide to Participate in Centrifugal fan repair Tenders

1. Eligibility & Prequalification

Before bidding, ensure compliance with:

  • Financial turnover requirements (30–50% of tender value)
  • Past experience (2–3 similar projects)
  • Valid solvency certificate

2. Mandatory Documentation Checklist

Prepare the following to avoid disqualification:

  • Digital Signature Certificate (Class 3 DSC)
  • GST, PAN, MSME/Udyam registration
  • EMD (Earnest Money Deposit) or exemption proof
  • Technical bid with execution methodology

3. BOQ Analysis & Financial Bidding

The BOQ (Bill of Quantities) is the most critical component:

  • Analyze item-wise pricing
  • Ensure competitive yet sustainable quotes
  • Avoid underbidding risks (L1 pressure)

✔ Expert analysis can significantly improve your bid success ratio.


Why Tender18 is a Trusted Platform for Centrifugal fan repair Tenders

✔ Proven Expertise in Government Procurement

We combine industry knowledge with practical bidding experience.

✔ Verified & Reliable Data

All Centrifugal fan repair tenders are sourced from official portals and cross-checked for accuracy.

✔ Advanced Filtering Tools

Filter tenders by value, EMD, location, and category for precise targeting.

✔ Corrigendum & Update Tracking

Get instant alerts on deadline changes and specification updates.

✔ Historical Data Insights

Analyze past tender results to understand pricing trends and competition.

✔ End-to-End Bidding Support

From discovery to submission, including GeM onboarding and strategy.


Growth of Centrifugal fan repair Sector in 2026

With the Government of India focusing on digital procurement and infrastructure expansion, the Centrifugal fan repair sector has seen significant growth in e-tendering opportunities.

The rise of GeM-based procurement models like:

  • L1 Purchase
  • Direct Procurement
  • MSME-friendly policies

…has made it easier for startups and SMEs to participate and win contracts


Frequently Asked Questions (SEO Optimized)

How can I get daily Centrifugal fan repair tender alerts?

You can register on Tender18 and select your preferred category. You will receive daily email alerts with all new Centrifugal fan repair tenders.

Is EMD mandatory for all Centrifugal fan repair tenders?

No, MSME and Udyam-registered businesses may get exemptions. Always check the NIT for specific conditions.

What is the difference between a Centrifugal fan repair work tender and supply tender?

A supply tender involves delivering goods, while a work tender includes execution, labor, and project completion.

Can I access private Centrifugal fan repair tenders on Tender18?

Yes, we also track major private sector and EPC tenders along with government opportunities.


Get Expert Support for Centrifugal fan repair Tenders

Tender18 is more than a listing platform—we are your strategic partner in winning tenders.

Our services include:

  • Tender discovery & analysis
  • Documentation support
  • Bid strategy & submission
  • GeM registration & OEM onboarding

📞 Call / WhatsApp: +91 7069661818
🌐 Website: www.tender18.com

T18 Ref No : 16188914
live Tender
Source : GEM Tenders
live Tender

tender for round the clock operation and preventive maintenance work , dismantling and shifting of asp , shifting of overhauled or new asp , oh of asp , dismantling and shifting of coarse ash pump , shifting of overhauled or new coarse ash pump , oh of coarse ash pump , dismantling and shifting of vp , shifting of overhauled or new vp , manpower assistance for oh of vp , manpower assistance for servicing of iac , manpower assistance for servicing of tac , oh of esp blower , oh of im and terminal silo blower , oh of im and terminal silo vent air fan , oh or servicing of hmdc , oh or servicing of rotary feeder , dismantling and shifting of balp or fwp or fahp or bahp or eco pump or hcsd pump , shifting of overhauled or new balp or fwp or fahp or bahp or eco pump or hcsd pump , oh of fwp , oh of balp pump , oh of fahp pump , oh of bahp pump , oh of economizer pump , oh of hmdc pump , oh of hp swp , oh of lp swp , oh of baofp , oh of rwp , oh of ahp clarifier sludge pump , oh of dosing pump , oh of awrp , oh of rpswp , oh of drain pump , oh of baha jet type drain pump , manpower assistance for fc of asp , manpower assistance for fc of coarse ash pump , oh of gb of asp , oh of gb of coarse ash pump , oh of lop of fc of asp , servicing of oc of fc of asp , servicing of tds of clarifier , alignment of asp , rotation of as disposal line , rotation of ba discharge pipe line , replacement of ms pipe line dia 250 nb to 350 nb , replacement of ci pipe line dia 200 nb to 250 nb , ash disposal by dumper or trolley to outside power house , servicing of dewatering pump , servicing of submersible pump , removal of wornout or damage valves , inatallation of new or repaired valves , replacement of spout , pipe laying and alignment of ms pipe 406.4mm , refractory works in bah , providing shuttering to carry out the refractory work , fabrication and erection of anchor of bah , scaffolding work in bottom ash hopper , isolation of bottom ash hopper , hiring of 01 no. jcb or compact loader bobcat , manpower assistance for oh or servicing of drier, round the clock operation routine and preventive mechanical maintenance of ahd, round the clock operation routine and preventive mechanical maintenance and housekeeping and cleaning works of complete ash handling plant of 2x660mw ctps obra, sonebhadra., dismantling and shifting of ash slurry pump from its foundation to maintenance bay, shifting of overhauled new ash slurry pump from maintenance bay to the foundation of pump, complete overhauling of ms indure make ash slurry pumps, dismantling and shifting of coarse ash pump from its foundation to maintenance bay, shifting of overhauled new coarse ash pump from maintenance bay to the foundation of pump, complete overhauling of ms indure make coarse ash pump, dismantling and shifting of vacuum pumps from its foundation to maintenance bay, shifting of overhauled new vacuum pumps from maintenance bay to the foundation of the pump, providing manpower assistance for overhauling of vacuum pumps in presence of oem ta make vacuunair aeromatic capacity 3871 cubic meter per hour, providing manpower assistance for servicing of instrument air compressor with drier in presence of oem ta make atlas copco capacity 1300 cubic meter per hour, providing manpower assistance for servicing of transport air compressor in presence of oem ta make atlas copco capacity 8250 or 7500 cubic meter per hour, complete overhauling of esp fluidizing air blower make model rh 120ac capacity 660 cubic meter per hour, complete overhauling of im and terminal silo aeration blower fluidizing air blower make model rhh 20wc capacity 1400 cubic meter per hour, complete overhauling of im and terminal silo vent air fan type centrifugal make ms maxim air, complete overhauling or servicing of hmdc installed at im and terminal silo, complete overhauling or servicing of rotary feeder installed in im and terminal silo tank, dismantling and shifting of balp or fwp or fahp or bahp or eco. pump or hcsd pump from its foundation to maintenance bay, shifting of overhauled or new balp or fwp or fahp or bahp or eco. pump or hmdc pump from maintenance bay to the foundation of the pump, overhauling of flushing water pump fwp, overhauling of bottom ash low pressure pump balp, overhauling of fly ash high pressure pump fahp, overhauling of bottom ash high pressure pump bahp, overhauling of economizer pump, overhauling of hydro mix dust conditioner pump hmdc for im and terminal silo, overhauling of hp seal water pump, overhauling of lp seal water pump, overhauling of bottom ash overflow pump baofp, overhauling of recycle water pump rwp, overhauling of ahp clarifier sludge pump, overhauling of alum lime and poly electrolyte dosing pump, overhauling of ash water recovery pump, overhauling of recovery pump seal water pump, overhauling of drain pumps installed at ba hopper area ash slurry pump house vacuum pump area silo area and recovery clarifier area., overhauling of bottom ash hopper area jet type drain pump, providing manpower assistance for overhauling of fluidomat make fluid coupling model sc 10 300kw or 1480 rpm motor of ash slurry pump in presence of oem ta, providing manpower assistance for overhauling of fluidomat make model sc 8 50kw or 1480 rpm motor speed variation +20 to -20 percentage fluid coupling of course ash pump and clinker grinder drive assembly in presence of oem ta, overhauling of new allen berry works make gear box of ash slurry pump model csa250 260kw or 1150 rpm, overhauling of new allen berry works make gear box of coarse ash pump and clinker grinder drive assembly model csa125 55kw or 1500 rpm, overhauling of lube oil pump of fluid coupling of ash slurry pump, servicing of oil cooler of fluid coupling of ash slurry pump, complete servicing of turbo driving system of clarifier, alignment of ash slurry pump, rotation of ash slurry disposal lines 400x 9.5mm thk nb, rotation of bottom ash discharge pipe line 200 nb, replacement of ms pipe line dia 250 nb to 350 nb, replacement of ci pipe line dia.200 nb to 250 nb, in case the huge quantity of ash accumulated at esp or im silo or terminal silo floor the same shall be segregated and lifted by dumper or trolley to outside powerhouse boundary for its disposal of 2x660mw ctps. one dumper equal to two tractor trolley, complete servicing of dewatering pump., servicing of goodwin make submersible pump of capacity 200 cubic meter per hour mechanical work, removal of worn out or damaged valves of size more than 80mm nb from ash disposal line or seal water line or ash water line etc., installation of new or repaired valves of size more than 80mm nb in ash disposal line or seal water line or ash water line etc., replacement or repairing of spout of im silo or terminal silo, pipe laying and alignment of following diameter ms pipe over the rcc pedestal of height approx. varies from 300 to 1500mm which includes transportation of pipe and its accessories at erection site including cutting, grinding as well as its welding tightening of coupling clamping bolt and nuts gasket etc. including testing as per recommendation of field quality plan satisfactory hydraulic testing commissioning etc. required for proper completion of work including cost of all labour material t and p etc. erw ms pipe od 406.4mm near im silo area, refractory works in bottom ash hopper, providing shuttering to carry out the refractory work, fabrication and erection of anchor of bah, scaffolding work in bottom ash hopper, isolation of bottom ash hopper, hiring of 01 no. jcb or compact loader bobcat, providing manpower assistance for overhauling or servicing of drier in presence of oem ta make ms mellcon job no csu 58 i


Tender Value : 88726435
Due Date : Aug 12, 2026
T18 Ref No : 16239962
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for with 2000 lumen , rewinding of ceiling fan motors with sweep up to 1400 mm , rewinding of exhaust fan motors with sweep up to 450 mm , rewinding of pedestal fan motors with sweep up to 450 mm , replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard , replacement of faulty piano switch 5 or 6 amp on the existing switchboard , replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard , replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard , replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db , replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db , refilling of existing 4.5kg, co2 type fire extinguisher , repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable , supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay i , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25 a 415 v tp contactor, mnx25, ac3 rating suitable for din rail mount , repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing , supplying and charging or topping of r 22 refrigerant gas , repair of 7tr conventional package ac unit of singhson make by replacement of the faulty, ocm of ems at te bldg and staff qtrs at chd pune sh attending defects at rnc, supplying and fixing of led indicators red, yellow, blue or green of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels etc as reqd., supplying and fixing of ac ammeter 0 to 200a class 1, analog 96mm size of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd, supplying and fixing of ac voltmeter 0 to 500v class 1, analog 96 mm of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of hn type 63 a fuse link compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of voltmeter selector switch of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., supplying and fixing of 100 a, 415 v, 4 pole isolator of same make, model and compatible with existing ems comprising of 22kv 500 kva id substation, mv, lt or control panels as reqd., servicing and repairing of 800 a, air circuit breakers of c and s make including draw out from panel cleaning of jaw contact and arc chut by using crc or wd40, proper alignment, testing etc as reqd., repairing and calibration of existing apfc relay of syntron make for 135 kvar capacitor panel including auto mode operation and on load testing etc complete as reqd., attending oil leakage of 22kv, 500kva transformer voltamp make, with highgrade oil resistant nitrile or rc70c neoprene bonded cork gaskets incl. supply and top up of 10 ltr of ehv grade mineral oil., carrying out repair or replacement of llop switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of water temperature switch suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of digital rpm cum hour meter suitable for existing 500 kva ea set of greaves make with installation, connection, testing, commissioning as reqd., carrying out repair or replacement of brass battery terminal with copper lugs for 1 battery with installation, connection, testing, commissioning as reqd., attending leakage in exhaust silencer flexible bellow with brazing or repairing or replacement of existing 500 kva ea set of greaves make etc as reqd., carrying out repair or replacement of charging alternator incl. replacement of components or rewinding of existing 500 kva ea set of greaves make with inst., connection, testing, commissioning etc., attending engine oil leakage of top head and rocker cover engine, fuel pump, tank, fuel valves of 500 kva greaves dg set having engine model tbd 4iv12p, with all genuine greaves cotton spares etc., carrying out servicing, chemical descaling and high-pressure jet cleaning of the radiator of 500 kva dg set incl. dismantling radiator, replacement of rubber hoses and clamps, coolant top up etc., repairing, rewinding of 7.5hp beacon make centrifugal pump set incl. greasing, varnishing, replac. of wornout bearings and gland packing incl. dismantling, handling, transp. and reinstallation etc., replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve, with all accessories including testing commissioning etc complete as required, repairing of 1.5 tr split ac units by replacement or repair of blower motor for indoor unit of voltas make with connections, testing, commissioning etc as reqd., repairing of 1.5 tr split ac units by attending of leakage incl. brazing or flaring the leak points, vacumising, purging flushing and supplying and charging of r22 or r410 or r134 refrigerant gas etc, supply and fixing 20 watt aluminium led batten tubelight with 2000 lumen for commercial use on wall or ceiling incl. testing commissioning etc complete as required, rewinding of ceiling fan motors with sweep up to 1400 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd, rewinding of exhaust fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., rewinding of pedestal fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., replacement of faulty 100 watt, two module, 5 step electronic fan regulator on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty piano switch 5 or 6 amp on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db including connections, testing and commissioning as reqd., refilling of existing 4.5kg, co2 type fire extinguisher including to and fro transportation including replacing faulty horn, hose pipe, hydraulic pressure testing, cleaning, labelling etc. as reqd., repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable from pole junction box to fitting etc. complete as reqd., supplying and laying 25mm x 5mm gi strip at 0.50 metre below ground as strip earth electrode, including connection with gi nut, bolt, spring washer etc. as required., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on and off push button including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty overload relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty on delay timer including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty pla relay including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty connector for power terminal including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty thermostat including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hand shut off valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty drier filter including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty safety pressure relief valve including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp gauge including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty hp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty lp cutout including wiring, connections, testing, commissioning etc as reqd., repair of 7tr conventional package ac unit of singhson make by replacement of the faulty 25a 415v tp contactor, mnx25, ac3 rating suitable for din rail mount incl. wiring, connection, testing as reqd, repair of 7 tr singhson package ac unit by nitrogen pressure testing, leak rectification, flushing, brazing or flaring, vacuuming, purging, leak-proofing, testing and commissioning etc as reqd, supplying and charging or topping of r 22 refrigerant gas in existing 7 tr package ac units etc compete as required, repair of 7tr conventional package ac unit of singhson make by replacement of the faulty condenser fan motor 1 phase, 0.5hp motor including wiring, connections, testing, commissioning etc as reqd.


Tender Value : 0
Due Date : Aug 05, 2026
T18 Ref No : 16239963
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for providing and fixing of 5 or 6 amps piano switch , providing and fixing of 15 or 16 amps piano switch , providing and fixing of 3 pin 5 or 6 amps piano socket , providing and fixing of 6 pin 15 or 16 amps piano socket , providing and fixing of 100watt step type electronic fan regulator , providing and fixing of call bell or buzzer , providing and fixing of 2.5mfd capacitor , providing and fixing of 36watt fl. tube light , providing and fixing of 20w aluminium led batten tubelight , repairing of ceiling fan upto 1400mm sweep , repairing of wall fan upto 450mm sweep , repairing of exhaust fan upto 450mm sweep , providing and fixing of 1400mm sweep, copper wound ceiling fan , repairing of faulty compound light fitting , providing and fixing of 40mm dia heavy duty isi marked brass foot valve , providing and fixing of 50mm dia heavy duty isi marked brass foot valve , providing and fixing of 40mm dia heavy duty upvc pipe , providing and fixing of 50mm dia heavy duty upvc pipe , painting of 16nos. compound light pole, 7nos. water pumps , repairing of 3hp centrifugal water pump , providing and fixing of 12v, 7ah smf battery , providing and fixing of response indicator , providing and fixing of hammer and chain , rectification of fault in existing fd and fa system , replacement of hose pipe alongwith horn , refilling of existing 4.5kg, co2 type fire extinguisher , providing and fixing of space heater , providing and fixing of red or yellow or green colour led indicating lamp , servicing of 11kv, 400amp oil circuit breaker , attending oil leakage of 500kva transformer , servicing and repairing of 800a to 1250a acb , providing and fixing of blue colour led indicating lamp , providing and fixing of 0 to 600v range ac voltmeter of 96 sq.mm size , providing and fixing of 6a vss with control wiring etc. , providing and fixing of operating handle suitable for 1250a acb , providing and fixing of under voltage coil suitable for 800a or 1250a acb , providing and fixing of shunt release coil suitable for 800a or 1250a acb , providing and fixing of 32a, 4way tpn connector , providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link , providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link , providing and fixing of 25kvar md xl type 440v capacitor , providing and fixing of 5kvar md xl type 440v capacitor , providing and fixing of 10kvar md xl type 440v capacitor , repairing of apfc relay of 100kvar capacitor panel , repairing of electrical and mechanical interlocking , providing and fixing of hp cutout , providing and fixing of lp cutout , providing and fixing of hp gauge , providing and fixing of lp gauge , providing and fixing of thermostat , providing and fixing of condenser fan blade , providing and fixing of blower bearing , providing and fixing of mpr d2 overload relay , providing and fixing of 230v a.c. hooter , carrying out nitrogen pressure testing , supplying and charging of r 22 refrigerant gas , providing and fixing of 0.5 hp, 230v a.c. condenser fan motor , providing and fixing of v belt suitable for charging alternator , providing and fixing of 24v dc hooter for dg set panel , attending engine oil leakage, ocm of ems at model colony pune sh attending defects in scope of satyam enterprises at risk and cost, providing and fixing of 5 or 6 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 15 or 16 amps piano switch on existing switchboard complete etc. as reqd., providing and fixing of 3 pin 5 or 6 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 6 pin 15 or 16 amps piano socket on existing switchboard complete etc. as reqd., providing and fixing of 100watt step type electronic fan regulator on existing switchboard complete etc. as reqd., providing and fixing of call bell or buzzer suitable for 230v, 1phase ac supply complete etc. as reqd., providing and fixing of 2.5mfd capacitor in existing fan complete etc. as reqd., providing and fixing of 36watt fluorescent tube light complete etc. as reqd., providing and fixing of 20w aluminium led batten tubelight with aluminium heat sink, 6500k cool day light, 2000 lumen for commercial use including testing commissioning etc complete as reqd, repairing of ceiling fan upto 1400mm sweep including removing, servicing, rewinding, varnishing, replacement of bearing, to and fro transportation, reinstallation testing etc complete as reqd., repairing of wall fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, repairing of exhaust fan upto 450mm sweep incl. removing, servicing, rewinding, varnishing, replacement of bearing or bushing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 1400mm sweep, 80watt, 280 to 370rpm, copper wound ceiling fan incl. 3nos. blade, 30cm long down rod, 2no. canopies etc. suitable for 230v, 1ph ac supply etc. complete as reqd, repairing of faulty compound light fitting incl. supplying and fixing high performance cool daylight 40watts led bulb, alongwith 1.5sqmm copper wiring from pole box to fitting etc complete as reqd, providing and fixing of 40mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 50mm dia heavy duty isi marked brass foot valve in ug tank including leakproof jointing testing commissioning etc complete as required., providing and fixing of 40mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, providing and fixing of 50mm dia heavy duty upvc pipe alongwith all accessories, plumbing work etc. for water pump suction line including leakproof jointing testing commissioning etc complete as reqd, painting of 16nos. compound light pole, 7nos. 1hp to 10hp capacity water pumps incl. surface cleaning and applying one or more coats of approved shade synthetic enamel paint complete etc. as reqd., repairing of 3hp centrifugal water pump incl. rewinding, varnishing, greasing, replacement of bearings, nutbolts, gland packing, to and fro transportation, reinstallation testing etc complete as reqd, providing and fixing of 12v, 7ah semi maintenance free battery in the existing fire detection panel including connection testing commissioning etc complete as required., providing and fixing of response indicator with metallic cover, 2nos. leds on existing surface or recess ms box including connection testing commissioning etc complete as required., providing and fixing of hammer and chain on existing surface or recess manual call point box etc complete as required., rectification of fault in existing fd and fa system incl. checking of control wiring, repairing of control cards in mcp or lcp, hooters, detectors, ri, pill box, pa system etc complete as required., replacement of hose pipe alongwith horn of 4.5kg co2 type fire extinguisher etc complete as required., refilling of existing 4.5kg, co2 type fire extinguisher including transportation to and fro, hydrualic pressure, testing, cleaning, labling etc. complete as required., providing and fixing of space heater for 11kv ht panel inclding connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp suitable for 110v ac supply in 11kv ht panel including connection, testing, commissioning etc. as reqd., servicing of 11kv, 400amp oil circuit breaker incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, attending oil leakage through tap changer, oil tank of 500kva transformer incl. replacement of gasket, cleaning of oil level guage side glass and fixing of marshalling box cover etc complete as reqd, servicing and repairing of 800a to 1250a acb incl. checking, cleaning of fixed and moving parts with crc, lubrication, tightening loose contacts, alignment etc. testing, commissioning etc as reqd, providing and fixing of blue colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of red or yellow or green colour led indicating lamp for lt panel including connection, testing, commissioning etc. as reqd., providing and fixing of 0 to 600v range 96 sq.mm size ac voltmeter having class 1 accuracy in lt panel including connection testing commissioning complete etc. as reqd., providing and fixing of 3 pole and off 6a, voltmeter selector switch with control wiring in lt panel etc. complete as reqd., providing and fixing of operating handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of drawout handle suitable for 1250a acb with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of under voltage coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of shunt release coil suitable for 800a or 1250a acb including connection testing commissioning etc. complete as reqd., providing and fixing of 32a, 4way tpn connector in lt panel with minor fabrication work if reqd. etc. complete as reqd., providing and fixing of 63a, din type hrc fuse carrier with 63a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 100a, din type hrc fuse carrier with 100a fuse link of l and t make including connection testing commissioning etc. complete as reqd., providing and fixing of 25kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 5kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., providing and fixing of 10kvar md xl type 440v capacitor including connection, testing, commissioning etc. as reqd., repairing of apfc relay of 100kvar capacitor panel including calibration, testing on load and auto mode operation, testing, commissioning etc. as reqd., repairing of electrical and mechanical interlocking between 4nos. incomers and 1no. bus coupler including replacing mechanical locks, wiring, connection, testing, commissioning etc. as reqd., providing and fixing of hp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp cutout in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of hp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of lp gauge in 7tr conventional package ac unit including soap test, connection testing commissioning etc. complete as reqd., providing and fixing of thermostat in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of condenser fan blade in condenser of 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of blower bearing in 7tr conventional package ac unit including testing commissioning etc. complete as reqd., providing and fixing of mpr d2 overload relay in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., providing and fixing of 230v a.c. hooter in 7tr conventional package ac unit including connection testing commissioning etc. complete as reqd., carrying out nitrogen pressure testing and attending leackage of 7tr package ac refrigerant circuit incl. leak testing, flaring, brazing, flushing, vacuumising, purging etc. complete as reqd., supplying and charging of r 22 refrigerant gas in existing 7tr conventional package ac refrigerant circuit etc complete as required., providing and fixing of 0.5 hp, 230v a.c. condenser fan motor suitable for fixing in condenser of sidwal or singhsons make 7tr or 10tr ac pkg unit incl. connection testing comm. etc complete as reqd., providing and fixing of v belt suitable for charging alternator of 500kva cummins make vt 1710g model ea set etc complete as reqd., providing and fixing of 24v dc hooter for dg set panel including connection testing commissioning etc. complete as reqd., attending engine oil leakage at top head and rocker cover, fuel pump etc. incl. replacement of tappet gasket, rubber o rings, mounting washer, high temp. rtv silicone sealant, fuel hoses etc. as reqd.


Tender Value : 0
Due Date : Aug 04, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16239965
live Tender
Location : pune , maharashtra
Source : GEM Tenders
live Tender

tender for repair including replacement of 1 set of led indicators red, yellow, blue or green , repair including replacement of ac ammeter 0 to 200 a class 1, analog 96 mm , repair including replacement of ac voltmeter 0 to 500 v class 1, analog 96 mm , repair including replacement of hn type 63 a fuse link , repair including replacement of voltmeter selector switch , repair including replacement of 3 position ammeter selector switch , repair including replacement of 100 a, 415 v, 4 pole isolator , supply installation testing and commissioning of 22 kv drop out fuse and rod assembly without insulators , repairing and calibration of existing apfc relay of syntron make , carrying out servicing, chemical descaling and high- pressure jet cleaning of the radiator of 250 kva dg set , replacement of stop solenoid valve with solenoid switch suitable for existing 250 kva ea set , replacement of battery terminal socket set for dg starting battery for existing 250 kva ea set , repairing, rewinding of 5 hp centrifugal pump set , replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve , replacement of faulty pcb of indoor unit of 1.5 tr or 2.0 tr inverter type split ac unit , repairing of 1.5 or 2.0 tr window or split or high sensible ac units by attending of leakage , replacement of faulty batten tube light fitting with supplying and fixing of 20 to 28 watt led type tube light fitting , rewinding of ceiling fan motors with sweep up to 1400 mm , rewinding of exhaust fan motors with sweep up to 450 mm , replacement of faulty 100 watt, step type electronic fan regulator on the existing switchboard , replacement of faulty switch 5 or 6 amp on the existing switchboard , replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard , replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard , replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db , replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db , repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable, ocm of ems at te compound at bhosari pune sh attending defects at rnc, repair including replacement of 1 set of led indicators comprising red, yellow, blue or green indicators on mv or lt or dg panel with compatibility to exisitng available system, testing etc as reqd., repair including replacement of ac ammeter 0 to 200a class 1, analog 96 mm size on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of ac voltmeter 0 to 500v class 1, analog 96 mm on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of hn type 63 a fuse link in mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of voltmeter selector switch on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., repair including replacement of 3 position ammeter selector switch on mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., supplying and fixing of 100 a, 415 v, 4 pole isolator in mv or lt or dg panel with compatibility to exisitng available system, testing etc complete as reqd., supply, installation, testing and commissioning of 22 kv drop out fuse and rod assembly without insulators etc complete as required, repairing and calibration of existing apfc relay of syntron make for 135 kvar capacitor panel including auto mode operation and on load testing etc complete as reqd., carrying out servicing, chemical descaling and high-pressure jet cleaning of the radiator of 250 kva dg set incl. dismantling radiator, replacement of rubber hoses and clamps, coolant top up etc., replacement of stop solenoid valve with solenoid switch suitable for existing 250 kva ea set with installation, connection, testing, commissioning as reqd., replacement of battery terminal socket set for dg starting battery for existing 250 kva ea set with installation, connection, testing, commissioning as reqd., repairing, rewinding of 5 hp centrifugal pump set incl. greasing, varnishing, replacement of wornout bearings and gland packing incl. dismantling, handling, transportation and reinstallation etc., replacement of faulty foot valve with a 40 mm dia heavy duty brass foot valve, with all accessories including testing commissioning etc complete as required, replacement of faulty pcb of indoor unit of 1.5 tr or 2.0 tr inverter type split ac unit including installation, connection, testing and commissioning etc complete as reqd., repairing of 1.5 or 2tr w or s or hs ac units by attending of leakage incl. brazing or flaring leak points, vacumising, purging flushing and supplying and charging of r22orr32orr410orr134 gas etc, replacement of faulty batten tube light fitting with supplying and fixing of 20 to 28 watt led type tube light fitting incl. testing commissioning etc complete as required, rewinding of ceiling fan motors with sweep up to 1400 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd, rewinding of exhaust fan motors with sweep up to 450 mm, including replacement of worn out bearings, shaft, bush, capacitor, greasing, varnishing, taping, insulation, testing, commissioning as reqd., replacement of faulty 100 watt, step type electronic fan regulator on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty switch 5 or 6 amp on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 3 pin 5 or 6 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 6 pin 15 or 16 amp socket outlet on the existing switchboard including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve sp mcb in the existing mcb db including connections, testing and commissioning as reqd., replacement of faulty 5 to 32 a, c curve dp mcb in the existing mcb db including connections, testing and commissioning as reqd., repairing of faulty compound light with provision of high performance cool daylight 40 watt led bulb, and 2 x 1.5 sq mm cu cond. cable from pole junction box to fitting etc. complete as reqd.


Tender Value : 128565
Due Date : Aug 05, 2026
T18 Ref No : 15792767
Location : varanasi , uttar pradesh
Source : GEM Tenders

tender for o and m with aicmc of hvac and vrv system at varanasi airport title1 , title2 , title3 , title4 , title5 , title6 , title7 , title8 , title9 , title10 , title11 , title12 , title13 , title14 , title15 , title16 , title17 , title18 , title19 , title20 , title21 , title22 , title23 , title24 , title25 , title26 , title27 , title28 , title29 , title30 , title31 , title32 , title33 , title34 , title35 , title36 , title37 , title38 , title39 , title40 , title41 , title42 , title43 , title44 , title45 , title46 , title47 , title48 , title49 , title50, o and m with aicmc of hvac and vrv system at varanasi airport, operation and routine maintenance of water cooled chiller hvac system, 3x500tr i/c ahus and cooling tower, vrv system at various locations inside the terminal building and medical centre, various pumps and other installation of wtp and stp, ro, water coolers and split/tower/window ac units at various locations, water fountains inside the terminal building, ensuring serviceability/ satisfactory working condition of the systems i/c maintenance of records/logbook/ documents etc. on all days i/c saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following min. no. of man power- (a) supervisor (highly skilled) - 01 no. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 03 nos. (ie 01 no. round the clock on all days in every week for operation of chiller, reliever shall be provided on weekly off). (c) ac technician / mechanic (skilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of r.o., water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off). (d) asst. ac mechanic cum operator (semi skilled) - 09 nos. (i.e. 01 no. round the clock for operation of ahu, 01 no. round the clock for operation and maintenance of wtp, 01 no. round the clock for operation of stp on all days in every week, reliever shall be provided on weekly off). (e) asst. ac mechanic cum operator (semi skilled) - 01 no. (i.e. 01 no. in general shift for maintenance of stp, reliever shall be provided on weekly off). (f) helper (unskilled) - 03 nos. (i.e. 01 no. round the clock on all days in every week for hvac, reliever shall be provided on weekly off). (g) helper (unskilled) - 02 nos. (ie 02 no. in general shift on all days in every week for operation and routine maintenance of ro, water coolers and split/tower/window ac units at various locations, reliever shall be provided on weekly off)., operation and routine maintenance of vrv system at ats cum technical block and precision air conditioning system at new mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) supervisor (highly skilled) - 01 nos. (i.e. 01 no. in general shift on 06 days in every week) (b) ac technician / mechanic (skilled) - 01 nos. (i.e. 01 no. in general shift on all days in every week for operation and routine maintenance of vrv system at ats cum technical block and pac system at new mssr building, reliever shall be provided on weekly off). (c) asst. ac mechanic cum operator (semi skilled) - 06 nos. (i.e. 01 no. round the clock for operation and routine maintenance of vrv system in ats block and 01 no. round the clock for operation and routine maintenance of pac system at new mssr building on all days in every week, reliever shall be provided on weekly off)., operation and routine maintenance of packaged air conditioning system at old mssr building including maintenance of records/logbook/ documents etc. on all days including saturday, sunday and holidays as per tender specifications, terms and conditions by supplying of following minimum number of man power - (a) asst. ac mechanic cum operator (semi skilled) - 03 nos. (i.e. 01 no. round the clock for operation and routine maintenance of packaged air conditioning system at old mssr building on all days in every week, reliever shall be provided on weekly off)., annual all inclusive comprehensive maintenance contract of central ac plant (hvac) for 3x500tr (make- mcquay) centrifugal chiller type comprising of 3 no. cooling tower (make- advance) and 1no cooling tower (make- bell) with make-up tank, associated pumps as condenser water pump - 03 no(40hp), primary water pump - 03no (25hp), secondary water pump 12 hr - 03 no. (25hp), secondary water pump 24hr- 03 no. (15hp) with 06 no vfd with secondary pumps, hot water generator of 400kw (01 no) with in build panel for 8 zones , air handling unit (floor mounted) - 19 no. up to 100 tr and min 50tr capacity with 08 no vfds, ceiling suspended air handling unit - 17 no up to 3 to 5 tr with electrical starter panel in each hru 03 no of 4250 cmh, 4675 cmh, 2754 cmh with their electrical panels, ac risers - 82 no. with nozzles with respective ahus, ozone system of 06no of make- ruks canada ltd, electrical panel in plant room p1 , p2 and p3 for the operation of chillers, hot water generator and all associated pumps, water softening plant its electrical panel and pumps. above system complete including chiller pipe line, ac duct, grills diffusers, valves, gas charging, winding of motors, displays, instrumentations etc. complete as required related with hvac system. (the supply of consumable spares as mentioned in item-24 to 27 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive periodical maintenance of daikin make vrv system installed at new atc tower ,technical block and substation having total of 143 nos. vrv indoor units including ductable, high wall and cassette units of different capacities. total of outdoor units clubbed in 3 or 2 units together - 12 sets of total capacity of odu - 492 hp. maintenance work is inclusive of all spares required for repair, maintenance as per manufacturer schedule, servicing including routine preventive maintenance, breakdown maintenance including repair/replacement of compressor, electronic circuit board, mechanical equipment, safety controls and instrumentations, gas charging, fan , fan motors, thermal insulation, drain pumps, remote control console/units etc. ensuring serviceability/ satisfactory working condition of the system, maintenance of recordes/documentation etc. as per tender conditions covered under this contract on all days including saturday,sunday and holiday etc. as required., annual all inclusive comprehensive maintenance contract of 144hp vrv air-conditioning system installed in security hold area and passenger boarding bridge fixed finger (16hp - 09 set outdoor units model no-jrnu160lte5.apune, 4 tr- 16 set cassette type indoor units model number-jrnu48gtma4.apune, 6.3 tr - 04 set ductable type indoor units model number-jrnu76gb8a4.apune, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed in airlines/aai offices in departure area inside terminal building (20hp - 01 set outdoor units model no- ivrfb-20th, 1.7 tr- 10 set cassette type indoor units model number-vlc-20, makes-bluestar) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. upto 1.5 tr window/split ac, annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (2tr split/cassette/tower ac), annual comprehensive maintenance of following air-conditioners of different makes installed at different locations including providing and replacing all necessary consumables, spares, including compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers, wherever connected etc. as required. (3.0 tr split/tower type ac), annual comprehensive maintenance of water coolers of all type, makes and capacities with providing necessary consumables, spares, compressors and refrigerant etc. complete as required as per special condition including cmc of voltage stabilizers wherever connected etc. complete as required., annual comprehensive maintenance of water purifiers of aqua guard make including replacement of all defective components like uv lamp etc. and consumables and carrying out bimonthly servicing at installed position etc. complete as required.(the supply of consumable spares filters as mentioned in item no-40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro up to 50 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), annual comprehensive maintenance of ro above 50 up to 100 liter capacity including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39and40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), all inclusive comprehensive maintenance of 3 units each of 2x8tr capacity packaged air-conditioning plant installed at old mssr building (make - bluestar) including replacing defective components, carrying out preventive and breakdown maintenance like arresting of leakage, topping up of refrigerant gas, lubrication, rewinding/ replacing of all type of motors, repairing/ replacing of compressors, repairing / replacing of electrical components etc and other works required from time to time for proper maintenance of units including maintenance of records as per terms and condition all days including sundays and holidays., annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at conference room and adjacent offices in terminal building including 2x 10hp outdoor units, 7x 2tr cassette type indoor units, make-daikin including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in passenger boarding bridge fixed link ( 1x 18 hp-02 set outdoor units model no-jrun180lls4, 4x 3tr-02set cassette type indoor units model number-rnu36gtna4, makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 40hp vrv air-conditioning system installed in passenger boarding bridge fixed finger (1x 20hp-02 set outdoor units model no-jrun200lls4, 4x 3tr-02set cassette type indoor units model number-jrnu36gtna4 , makes-lg) including compressor and providing all necessary consumables, refrigerant gas, cu piping, cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 36hp vrv air-conditioning system installed in new fire station medical centre ( 3x 12 hp outdoor units, model no.-map1206ht8d-xa,cassette type indoor units 9x 2 tr, model no.- mmu-up0241hp-e and 3x1.5 tr, model no.-mmu-up0181hp-e make-toshiba) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of cold storage 40000 btu-02 set (make- bluestar) by providing quarterly visit and any number of break down as and when required including replacing/repairing compressor, condenser coil, temperature controller and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual all inclusive comprehensive maintenance contract of 3 x 15 tr (3 sets each of 01 no. indoor unit and 02 no. outdoor units) floor mounted, bottom discharge, top suction, air cooled dx type crac precision air-conditioning system units installed in new mssr building suitable to maintain equipment room temperature at 18 deg c plus minus 2 deg c (1x 15 tr - 03 set indoor units model no-pdx px054d, 2 no. x 03 set outdoor units model number-hcr-43 , makes-vertiv) including compressor and providing all necessary consumables, refrigerant gas, cu piping ,cabling etc., complete as per site requirement., annual comprehensive maintenance of drinking water fountain with chilling water fountain one at higher level and another at lower level to match disability compliance make oasis/haws/wae including replacement of all defective components and carrying out bimonthly servicing at installed position etc. complete as required. (the supply of consumable spares membrane and filters as mentioned in item no-39 and 40 is not included in the scope of this item however installation and satisfactory working of equipment covers in this items.), cleaning of the solar module regularly two cycle in a month including minor repairing of tulu pump and monitoring of 600 kwp (500kwp+100kwp)grid connected roof top mounted solar photo voltaic power plant by deploying minimum one number unskilled man power in general shift excluding weekly off including maintaining records as per special conditions of the contract and as per direction of e-i-c. (consumables cleaning material like wiper duster, pvc flexible pipe etc. are to be provided by the agency. the solar module are under warrantee whereas inverter to be maintained by oem. the agency has to liaison with oem for repairing/replacement of defective parts)., supply of spares for hvac not include in cmc item no. 4 (pvc fills 600x300x150mm), supply of spares for hvac not include in cmc item no. 4 (resin 220 na(o) for softener plant), supply of spares for hvac not include in cmc item no. 4 (salt for softener plant), supply of spares for hvac not include in cmc item no. 4 (chlorine for dosing in stp), supply and installation of copper tubing of suitable size up to 3tr split air-conditioning for inlet and outlet of refrigerant gas complete with electrical cabling and insulation etc. complete as required during shifting of existing ac units., supply and installation of 20 mm dia pvc rigid drain pipe i/c all accessories like bends, couplers, tees etc. complete as required during shifting of existing ac units., supply and fixing of insulation of nitrile rubber in existing copper tubing for both inlet and outlet of existing installed air conditioner etc. complete as required during shifting of existing ac units as per direction of eic., dismantling of high wall split type air-conditioning unit, shifting, re-installation, testing and commissioning of capacity up to 3.00 tr air-conditioner units, fixing of existing refrigerant pipe, insulation and existing flexible copper conductor cable between evaporator and condenser units, topping up refrigerant gas etc. complete as required as per direction of eic., rewinding of 10/15 hp motor of submersible pump of (different stages ) different makes as per original size of insulated copper wire, sleeves complete with connection, interconnection etc as required., repairing of 10/15 hp submersible pump and motor (excluding rewinding of motor) of different stages and different makes i/c replacement of bearing bush, neck rings, bowl bush, running sleeve, key full, sand guard complete etc as required., repairing and rewinding of the existing water pump/ sewerage pump motor of capacity 0.75 hp to 3.0 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding, reinstallation the same, including testing and make the system in serviceable condition as required., repairing and rewinding of the existing blower motor/ filtered feed pump etc. of capacity 5 hp to 7.5 hp by dismantling from its position, transportation to the work shop, bringing back to the airport after repairing and rewinding and reinstallation the same, including testing and make the system in serviceable condition as required., testing of stp incoming and treated water sample on quarterly basis from reputed govt. lab and submission of test reports as per technical specifications.(rate for each sample), dismantling, removal, lowering, reinstalling, testing and commissioning of submersible pumps of different makes and capacities including arranging of tripod stand, chain pulley block etc. as required., supply of 3.7 kw/ 5.0 hp submersible pump-motor set suitable for discharge 80mm delivery of minimum 250 lpm against static head 45mtr consisting of multistage pumps with suitable motor suitable for operation on 415 volt, 50 hz a/c supply. pumps and motors must be connected with alignment shafts etc. complete as required., supply of shield membrane which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-13,14 and 22 suitable for kent/ aqua guard/oasis/haws/wae up to 100 liter capacity etc. complete as required., supply of carbon / sediment filter which is not included in cmc of ro / water purifier / water fountains as mentioned in item no-12,13,14 and 22 suitable for up to 100 liter capacity etc. complete as required., drinking water potability test quarterly basis as per technical specifications (rate for each sample)., supply of consumable urea for equalization tank of stp., supply of sand for sludge drying bed at stp., repairing/replacement of blower pipe tube at stp with suitable size pipe, elbow,socket and flange complete as required., supply of air blower filter at stp compatible to existing air blower., supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part -ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 300 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part- ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 250 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 200 mm dia, supplying, laying, fixing, testing and commissioning of ms class c chilled/ condenser water piping confirming to is 1239 part-ii of 1979 up to date with insulation and sand, cement mixture plastering and finishing complete with all necessary fittings such as bends, tees, reducers, flanges etc. and supports such as clamps, anti-vibration hangers etc. as per specification. 150 mm dia, annual all inclusive comprehensive maintenance contract of 20hp vrv air-conditioning system installed at pm safe house including 2x 10hp outdoor units with 6 x 2 tr, 2 x 1.5 tr and 1 x 1.1 tr high wall type indoor units, make-hitachi including compressor and providing all necessary consumables, refrigerant gas, piping, cabling etc., complete as per site requirement and special conditions and general terms and conditions of contract as required.


Tender Value : 20741360
Due Date : Jul 03, 2026

Unlock Full Tender Access

Start Free Trial to download documents before deadline

T18 Ref No : 16008457
Location : nanauta , uttar pradesh
Source : GEM Tenders

tender for centrifugal house item no 1 , centrifugal house item no 2 , centrifugal house item no 3 , centrifugal house item no 4 , centrifugal house item no 5 , centrifugal house item no 6 , centrifugal house item no 7 , centrifugal house item no 8 , centrifugal house item no 9 , centrifugal house item no 10 , centrifugal house item no 11 , centrifugal house item no 12 , centrifugal house item no 13 , centrifugal house item no 14 , centrifugal house item no 15 , centrifugal house item no 16 , centrifugal house item no 17 , centrifugal house item no 18 , centrifugal house item no 19 , centrifugal house item no 20 , centrifugal house item no 21 , centrifugal house item no 22 , centrifugal house item no 23 , centrifugal house item no 24 , centrifugal house item no 25 , e t p item no 1 , e t p item no 2 , crystallizer item no 1 , crystallizer item no 2 , crystallizer item no 4 , crystallizer item no 5 , crystallizer item no 6 , crystallizer item no 7 , schedule work item no 1 , schedule work item no 2 , schedule work item no 3 , schedule work item no 4 , schedule work item no 5 , schedule work item no 6 , schedule work item no 7 , schedule work item no 8 , schedule work item no 9 , schedule work item no 10 , schedule work item no 11 , schedule work item no 12 , schedule work item no 13 , schedule work item no 14 , schedule work item no 15 , schedule work item no 16 , schedule work item no 17 , schedule work item no 18 , schedule work item no 19 , schedule work item no 20 , schedule work item no 21 , schedule work item no 22 , schedule work item no 23 , schedule work item no 24 , schedule work item no 25 , schedule work item no 26 , schedule work item no 27 , schedule work item no 28 , schedule work item no 29 , schedule work item no 30 , schedule work item no 31 , schedule work item no 32 , schedule work item no 33 , schedule work item no 34 , schedule work item no 35 , schedule work item no 36 , schedule work item no 37 , schedule work item no 38 , schedule work item no 39 , schedule work item no 40 , schedule work item no 41 , schedule work item no 42 , schedule work item no 43 , schedule work item no 44 , schedule work item no 45 , schedule work item no 46 , schedule work item no 47 , schedule work item no 48 , schedule work item no 49 , schedule work item no 50 , schedule work item no 51 , schedule work item no 52 , schedule work item no 53 , schedule work item no 54 , schedule work item no 55, centrifugal house and etp fabrication work, to replace worn-out molasses jacket of b and c continuous centrifugal machine with proper trial, to replace worn-out molasses casing of a-centrifugal machine followed by satisfactory trial, replacement of worn out portion of horizontal sugar melter shell with steam and juice connection followed by leak proof trial, dismantling of existing stirrer shaft of magma mixture of b or c continuous machine straightening of worn out shaft replacement of bushes re-fitting of shaft arms and alignment of drive system with satisfactory trial, replacement of weak orworn out portion of sugar hopper, broken shaft of crystallizer to be made correct or replaced by new one alignment is to be done after proper fitting of arms and ribbon, replacement of worn-out bushes and arms of sugar melter with satisfactory trial, dismantling fabrication and erection of weak body shell of pug mill melter and magma mixer of a b and c fw or af cf machines, dis and fitting work of bushes of magma mixer and sugar elevator, replacement of worn- out or weak molasses ring along with fingure of wk-1500 cf machine complete in all respect, replacement of worn out channel after de-grouting and re-fitting of a4 or a5 side hopper no 04 new channel clit in size 4inchx4inch fitting of wooden strip, replacement of worn out or broken pedestal arms of magma mixture and pug mill, replacement of weak or worn out perforated sheet of hopper and fitting with frame, replacement of damaged or worn-out arms of mono crystallizer, dismantling fabrication and erection of ms coil of 1inchdiameter for wk-1500 and sc1350-kt cf machine with 3mm perforation, dismantling fabrication and erection of new molasses storage tank(1 5meter diameter x 1 5meter height) with 08mm ms plate for a centrifugal machine and providing with all connection nipples etc, dismantling of existing gate type masscuite taking valve 1250 batch type machine and fitting of pneumatic type butterfly valve in place of above and make in all necessary provision with satisfactory trial, dismantling fabrication and erection of worn out orweak conical discharge chute for continuous machine with 06mm new or old plate (as per sample), dismantling fabrication and fitting of man hole of vertical crystallizer, dismantling of old worn out or disturbed sugar hopper fabrication and erection of complete hopper along with satisfactory trial, dismantling of drive system of molasses conditioner replacement of weak top plate and re fitting of driving system with trial, modification work of sugar melter melt pump suction system comprise of catcher and receiving tank, fabrication of new cold/hot air blower fan and casing erection and fitting of new one along with satisfactory trial, fabrication and erection of top cover of continuous centrifugal machine steam/watercoil, repair of internal jacket of wk 1500 b-1 continuous centrifugal machine along with fixing of molasses baffle plate /fingure, disamntling,fabrication and fitting work of structure including rubber scrapper drum of etp clarification pit, fabrication,erection and fitting work of spray pond mesh type inlet channel stainer size-2 5mtx2 5mt, replacement of worn out bushes of air cooled crystallizer of both side after dismantling all drive arrangement (worm wheel reduction gear) and there after fitting alignment after replacement of bush (bush will be provided by factory), replacement of leaky cooling coil of c twin vertical crystallizer b mono vertical crystallizer with 3inch size ms pipe with proper hydraulic testing and trial, replacement of worn out or broken angle arms of crystallizer and replacing of paddel type arms with ribbon type of air cooled or vaccume crystallizer, repair of worn out or broken arm or ribbon of air cooled vacuum and seed crystallizer, replacement of weak shell of air cooled crystallizer, replacement of weak shell of a- vaccum crystallizer setting right of arms and necessary strengthning, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 1 inch diameter, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 2 inch diameter, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 3 inch diameter, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 4 inch diameter, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 6 inch diameter, dismantling ,fabrication and erection of m s pipe line including bend or flange etc 8 inch diameter, dismantling fabrication and erection of bend size-2 inch diameter (ms), dismantling fabrication and erection of bend size- 3 inch diameter (ms), dismantling fabrication and erection of bend size- 4 inch diameter (ms), dismantling fabrication and erection of bend size- 6 inch diameter (ms), dismantling fabrication and erection of bend size- 8 inch diameter (ms), dismantling fabrication and erection of bend size-10 inch diameter (ms), dismantling fabrication and erection of bend size-12 inch diameter (ms), dismantling fabrication and erection of nipple size- 1inch diameter (ms), dismantling fabrication and erection of nipple size- 2 inch diameter (ms), dismantling fabrication and erection of nipple size- 3 inch diameter (ms), dismantling fabrication and erection of nipple size- 4 inch diameter (ms), dismantling fabrication and erection of nipple size- 6 inch diameter (ms), dismantling fabrication and erection of nipple size- 8 inch diameter (ms), dismantling fabrication and erection of nipple size- 10 inch diameter (ms), dismantling fabrication and erection of nipple size- 12 inch diameter (ms), dismantling fabrication and erection of tee size- 4 inch diameter (ms), dismantling fabrication and erection of tee size- 6 inch diameter (ms), dismantling fabrication and erection of tee size- 8 inch diameter (ms), dismantling fabrication and erection of flange size- 4 inch diameter (ms), dismantling fabrication and erection of flange size- 6 inch diameter (ms), dismantling fabrication and erection of flange size- 8 inch diameter (ms), dismantling fabrication and erection of flange size- 10 inch diameter (ms), dismantling fabrication and erection of flange size- 12 inch diameter (ms), dismantling fabrication and erection of reducer size-4 inch diameter (ms), dismantling fabrication and erection of reducer size-6 inch diameter (ms), dismantling fabrication and erection of reducer size-8 inch diameter (ms), dismantling fabrication and erection of reducer size-10 inch diameter (ms), dismantling fabrication and erection of reducer size-12 inch diameter (ms), dismantling and fitting of valve size- 3 inch diameter, dismantling and fitting of valve size- 4 inch diameter, dismantling and fitting of valve size- 6 inch diameter, dismantling and fitting of valve size- 8 inch diameter, dismantling fabrication and fitting of man hole, dismantling fabrication and erection of platform by using old/new plate, fabrication and erection of railing from old material, dismantling of ms heavy structure / tank, dismantling of ms light structure, fabrication and erection light structure, fabrication and erection heavy structure, fabrication of pump bed with pump, reduction gear and motor alignment up to 7 5 h p, fabrication of pump bed with pump, reduction gear and motor alignment up to 10 h p, fabrication of pump bed with pump, reduction gear and motor alignment up to 25 h p, fabrication of pump bed with pump, reduction gear and motor alignment up to 30 h p, fabrication and erection of complete square / rectangular /round tank with conical bottom, fabrication and fitting of ms coil (coils are to be duly bend and not offset pipe welding offset welds shall not be treated as coils but as pipes ) size-25mm, fabrication and fitting of ms coil (coils are to be duly bend and not offset pipe welding offset welds shall not be treated as coils but as pipes ) size-50mm, fabrication and fitting of ms coil (coils are to be duly bend and not offset pipe welding offset welds shall not be treated as coils but as pipes ) size-75mm, fabrication and patchwork of equipments using old/ new ms plate by 6/8 mm thick plate over round vessels/any vessels


Due Date : Jul 14, 2026
Published By

Every year, central and state government departments release thousands of high-value contracts specifically dedicated to Centrifugal Fan Repair. Whether it involves bulk material supply, executing specialized operational services, or end-to-end turnkey project execution, the demand for capable vendors in the Centrifugal Fan Repair sector is massive.

At Tender18, we help businesses cut through the noise and exclusively target the exact work categories they specialize in. Instead of browsing through generic procurement sites, our platform isolates high-potential opportunities that match your specific industry capabilities.

Work Dynamics in the Centrifugal Fan Repair Sector

Government requirements for this specific vertical generally fall into distinct procurement patterns:

  • Product & Material Supply: Tenders focused strictly on sourcing, testing, and delivering high-quality items that meet the exact technical specifications of the buyer.
  • Service Level Agreements (SLAs): Long-term hiring of expert agencies for routine maintenance, manpower deployment, or continuous operational management.
  • Execution & Turnkey Projects: Comprehensive contracts where the bidder is responsible for everything from raw material procurement to final site installation and testing.

By focusing purely on your core strength in Centrifugal Fan Repair, you can build a highly profitable and stable pipeline of government clients.

Stop wasting time filtering through irrelevant notices. Our Centrifugal Fan Repair Tender Information Service is engineered for precision. We track exact product codes, service names, and specialized work terms across all government portals nationwide. When a buyer publishes a requirement that matches your specific business profile, our system alerts you instantly.

Deep Technical Insights & Documentation For Centrifugal Fan Repair Tenders

Bidding for specific works requires studying strict technical parameters. We provide immediate access to the core documents you need to evaluate the project:

  • Detailed Specifications & Drawings: Download the exact engineering guidelines, material testing standards, and quality benchmarks demanded by the buyer for Centrifugal Fan Repair.
  • Financial BOQ Spreadsheets: Access the official blank pricing formats where you need to input your unit rates, tax configurations, and total bid value.
  • Real-Time Technical Amendments: If the buying department changes the product specifications, alters the service scope, or shifts the delivery timeline, we instantly update the parent file so you are never caught off-guard.

Winning a contract for Centrifugal Fan Repair depends entirely on how perfectly your technical capabilities match the buyer’s demands. Even if you have the best product or service, a poorly formatted document or a missing compliance certificate will lead to instant technical rejection. Tender18’s Tender Bidding Service eliminates this risk by taking complete ownership of your digital submission.

Flawless Compliance & Portal Execution For Centrifugal Fan Repair Tenders

Under this service, Tender18 assigns a Dedicated Experienced Technical Person to your profile. This expert handles the heavy lifting of the entire bidding cycle:

  • Capability Mapping: We thoroughly cross-check your past completion certificates, ISO standard proofs, and financial turnover against the strict eligibility criteria required for Centrifugal Fan Repair bids.
  • Secure System Integration: Our technical desk seamlessly links your Class III Digital Signature Certificate (DSC) with the required e-procurement servers to securely encrypt your technical and financial envelopes.
  • Error-Free Financial Uploads: We audit your quoted BOQ pricing sheets for any formula or formatting errors before the final upload, ensuring your bid is successfully locked before the portal's closing hours.

Government buyers are aggressively using the Government e-Marketplace (GeM) for the direct procurement of Centrifugal Fan Repair. If your business profile is not accurately mapped on this portal, you remain practically invisible to these purchasing officers. Recognized as a trusted and expert GeM consultant, Tender18 offers specialized support to build, optimize, and maintain a highly visible vendor account for your business.

With an industry-leading support success ratio of over 95%, we handle the complex marketplace compliance so you can focus entirely on executing your orders

Expert Profile Management & Catalogue

Our dedicated consultants ensure your GeM presence is structurally perfect:

  • Precise Catalogue Listing: We upload and categorize your specific offerings under the exact search terms and parameters used by government buyers looking for Centrifugal Fan Repair, ensuring maximum search visibility.
  • OEM Dashboard & Assessment: For original manufacturers and creators, we guide you through the mandatory Quality Council of India (QCI) vendor assessments to successfully unlock your official OEM panel.
  • Profile Compliance & Caution Money: We manage your statutory documentation, brand approvals, and caution money limits to keep your account immune from technical suspensions.

Strategic Live Bid Participation

Beyond setup, we actively drive your market participation. Our team expertly handles the digital paperwork and rate configurations for GeM Custom Bids and Reverse Auctions (RA) related to Centrifugal Fan Repair, maximizing your chances of securing L1 status.

1.

How do I find government contracts exclusively matching my work in Centrifugal Fan Repair?

The easiest way is through the Tender18 platform. Instead of searching department by department, our system uses advanced keyword matching to gather all live supply, service, and execution tenders related directly to your core business in one place.

2.

Do I need specific testing or quality certificates to apply for these contracts?

It heavily depends on the nature of the work. For supply contracts, buyers often ask for ISO certifications, BIS marks, or specific lab testing reports. For service contracts, they may ask for labor licenses or past performance certificates (work orders).

3.

What is a BOQ and why is it important for my bid?

The Bill of Quantities (BOQ) is the official financial Excel sheet where you enter your competitive prices. Any mistake in this file—like adding extra rows, changing formulas, or saving it in the wrong format—will cause the portal server to reject your entire bid.

4.

Are samples required to be submitted physically before the digital bid opens?

For many product-based Centrifugal Fan Repair tenders, buying departments do ask bidders to submit physical samples to their office before the digital technical evaluation date. This requirement is always clearly mentioned in the official NIT document.

5.

How does the Dedicated Tender Expert from Tender18 help me?

Our assigned expert manages your total portal compliance. They extract the hidden rules from long tender PDFs, create a precise document checklist for your team, map your digital signature, and securely upload your technical and financial files onto the government servers.

6.

What is the role of a Digital Signature Certificate (DSC)?

A Class III DSC is a secure USB device that contains your digital identity. You cannot upload a bid without it. It is used to securely encrypt and lock your sensitive price data and technical documents so no one can view them before the official opening date.

7.

As an MSME, can I get financial benefits when bidding for Centrifugal Fan Repair?

Yes, the government strongly supports MSMEs. By uploading a valid Udyam Registration Certificate in the technical envelope, small businesses are frequently exempted from paying the initial Tender Document Fee and the Earnest Money Deposit (EMD).

8.

Why should I list my services or products on GeM for this category?

GeM is now the primary digital marketplace for all government agencies. If you are properly cataloged for Centrifugal Fan Repair, officers can view your profile and generate direct purchase orders or invite you to participate in exclusive Custom Bids.

9.

What makes Tender18 a reliable GeM support partner?

As a highly trusted and expert GeM consultant, Tender18 holds a proven support success ratio of over 95%. From flawless profile creation and complex catalogue mapping to OEM panel approvals and live Reverse Auction (RA) support, we handle it all seamlessly.

10.

What does "L1" mean in these government contracts?

"L1" stands for "Lowest Bidder 1". In government procurement, after all technical envelopes are approved, the financial sheets (BOQs) are opened. The bidder who has quoted the lowest compliant price for Centrifugal Fan Repair is declared L1 and is generally awarded the contract