tender for 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp supply installation testing and commissioning , fp mcb 63 amp supply installation testing and commissioning , fp mcb 40 amp supply installation testing and commissioning , sp and n distribution board 12 way hvac idu , dp mcb 32 amp supply installation testing and commissioning , sp mcb 6 or 10 amp supply installation testing and commissioning , sfu 100a tpn at main switch board supply installation testing and commissioning , chemical earth electrode earthing arrangement supply installation testing and commissioning , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system, supply installation testing and commissioning of vrv type ac, supply and delivery of 14 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 20 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 24 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, installation testing and commissioning of 14 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 20 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 24 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, supply of 1.5 tr vrf 4 way cassette indoor unit with cooling capacity 12 kw and above power input 110 to 125 w airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature, supply of 4 tr vrf 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature as per specifications, installation testing and commissioning of 1.5 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, installation testing and commissioning of 4 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, supply of 3 tr split type direct expansion air conditioning system with 4 way ceiling mounted cassette indoor unit and matching air cooled outdoor unit hermetically sealed scroll compressor condenser and evaporator coil drain pump remote control suitable for 50 degree ambient, installation testing and commissioning of 3 tr split type cassette dx air conditioning system including mounting of indoor and outdoor units vibration isolation pads electrical termination control wiring drain piping nitrogen pressure testing vacuumization refrigerant charging and trial run, supply of centralized remote controller unit of same make as ac units for centralized control and monitoring of all connected vrf indoor and outdoor units complete with all accessories as recommended by manufacturer, installation testing and commissioning of centralized remote control unit for vrf system including all wiring connections configuration of connected indoor and outdoor units testing and commissioning complete as required, supply of 25.4 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 22.2 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 19 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 15.86 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 12.7 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 9.5 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, installation testing and commissioning including vacuumization and nitrogen testing of 25.4 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 22.2 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 19 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 15.86 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 12.7 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 9.5 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, supply of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer suitable for combination of indoor and outdoor machines for vrf system complete with all accessories, installation testing and commissioning of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer for vrf system complete with all accessories as required, supply and delivery of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, laying of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, supply of pvc condensate drain pipe of suitable size for ac indoor units with supports clamps and insulation as required complete with all accessories as per instructions, installation of pvc condensate drain piping for ac indoor units with supports clamps and all accessories as per site requirement and instructions complete as required, supply of ms table top stands for installing outdoor units vrf outdoor 10 units and dx outdoor 1 unit duly epoxy coated including supply of cowl piece for each outdoor machine as required, installation testing and commissioning of ms table top stands for outdoor units including installation testing and commissioning of cowl piece for each outdoor machine as required, supply and filling of refrigerant gas r410a as required for vrf and dx air conditioning systems complete with all accessories as per manufacturer recommendations and site requirements, supply of 4 core x 10 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, supply of 4 core x 16 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, laying testing and commissioning of 4 core x 10 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, laying testing and commissioning of 4 core x 16 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, providing fabricating and fixing aluminium anodized partition for air conditioning enclosure using approved aluminium sections with 15 micron anodized finish comprising fixed glazed panels and aluminium framed glazed doors with 5 mm clear float glass door shutters frames floor springs hinges handles locks rubber beading and all accessories, wiring in pvc casing and capping system using 2 x 1.5 sq mm fr pvc insulated copper conductor wire with modular type switches sockets surface mounting plastic frames for light point to be terminated in ceiling rose or batten or angle holder 6 amp 230 volts for led panel light fitting, supply and delivery of recess or surface mounted 2 x 2 luminaire 24 w with 150 lm per watt low glare and cri greater than 90 for hospital ward and corridor lighting as per instructions, installation testing and commissioning of led panel 2 x 2 24 watts to be installed at male and female ward and corridors of hospital as per instructions, supply and delivery of 4 core x 50 sq mm xlpe insulated armoured pvc sheathed heavy duty copper conductor cable 1100 volts grade conforming to is 1554 or is 7098 part 1 of 1988 complete as required, supply and delivery of galvanized iron wire size 8 swg for earthing and cable support as per specifications and instructions, installation charges for fixing and running armoured cables with copper conductors 1100 volts grade on even surfaced walls beams ceilings with appropriate gi saddles and gi spacers with gi wire from central switch chamber to ac power mcbdb at electrical switch room, cable end termination both ends for lv xlpe armoured 4 core x 50 sq mm cable including supply and fixing of double compression cable glands stripping of insulation tinned plated copper lugs for all phases crimping gi nut bolts and washers hdgi 80 micron one set per termination, supply installation testing and commissioning of three pole and neutral distribution board in sheet steel enclosure ip 43 powder coated double door horizontal surface or recess mounting with insulated tinned copper bus bars neutral links din channels earthing terminals 8 way 8 plus 24 way without mcb, supply installation testing and commissioning of four pole isolator 125 amp in suitable enclosure for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 63 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 40 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole and neutral consumer unit type distribution board in sheet steel enclosure powder coated single door with acrylic window surface or recess mounting with insulated tinned copper bus bar neutral link din channel 12 way 2 plus 10 way without mcb, supply installation testing and commissioning of double pole mcb 32 amp for hvac indoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole mcb 6 or 10 amp for hvac indoor unit distribution board as per specifications and instructions, supply delivery installation testing and commissioning of switch disconnector fuse unit sfu in sheet steel enclosure suitable for din type hrc fuses with isi mark 100amp tpn to be installed at main switch board in electrical switch room, supply installation testing and commissioning of chemical earth electrode for earthing complete with chemical powder 100 mm dia x 3 m long bore frp chamber 500 x 500 x 200 mm with frp cover earthing rod buried vertically 3 m deep resistance tested with calibrated earth resistance meter, comprehensive annual maintenance contract for air conditioning system first year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system second year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system third year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fourth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fifth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms

Latest Tender Detail from mumbai port trust MPT for the tender for 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp supply installation testing and commissioning , fp mcb 63 amp supply installation testing and commissioning , fp mcb 40 amp supply installation testing and commissioning , sp and n distribution board 12 way hvac idu , dp mcb 32 amp supply installation testing and commissioning , sp mcb 6 or 10 amp supply installation testing and commissioning , sfu 100a tpn at main switch board supply installation testing and commissioning , chemical earth electrode earthing arrangement supply installation testing and commissioning , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system, supply installation testing and commissioning of vrv type ac, supply and delivery of 14 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 20 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, supply and delivery of 24 hp air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel pcb cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 pascal static pressure, installation testing and commissioning of 14 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 20 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, installation testing and commissioning of 24 hp air cooled vrf outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required, supply of 1.5 tr vrf 4 way cassette indoor unit with cooling capacity 12 kw and above power input 110 to 125 w airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature, supply of 4 tr vrf 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 db at low speed with mandatory auto bypass feature as per specifications, installation testing and commissioning of 1.5 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, installation testing and commissioning of 4 tr vrf 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required, supply of 3 tr split type direct expansion air conditioning system with 4 way ceiling mounted cassette indoor unit and matching air cooled outdoor unit hermetically sealed scroll compressor condenser and evaporator coil drain pump remote control suitable for 50 degree ambient, installation testing and commissioning of 3 tr split type cassette dx air conditioning system including mounting of indoor and outdoor units vibration isolation pads electrical termination control wiring drain piping nitrogen pressure testing vacuumization refrigerant charging and trial run, supply of centralized remote controller unit of same make as ac units for centralized control and monitoring of all connected vrf indoor and outdoor units complete with all accessories as recommended by manufacturer, installation testing and commissioning of centralized remote control unit for vrf system including all wiring connections configuration of connected indoor and outdoor units testing and commissioning complete as required, supply of 25.4 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 22.2 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 19 mm od hard drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 15.86 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 12.7 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, supply of 9.5 mm od soft drawn copper refrigerant piping tube thickness 1.2 mm with ring type hanger supports and 19 mm thick xlpe class o closed cell elastomeric nitrile rubber tubular insulation for suction and liquid lines complete with fittings and accessories, installation testing and commissioning including vacuumization and nitrogen testing of 25.4 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 22.2 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 19 mm od hard drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 15.86 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 12.7 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, installation testing and commissioning including vacuumization and nitrogen testing of 9.5 mm od soft drawn copper refrigerant piping for vrf system with all fittings supports and accessories as required, supply of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer suitable for combination of indoor and outdoor machines for vrf system complete with all accessories, installation testing and commissioning of refrigerant y and t joints vrv refnuts joints with insulation as recommended by manufacturer for vrf system complete with all accessories as required, supply and delivery of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, supply and delivery of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit as required as per site condition for ac system control and communication wiring complete with all necessary fittings, laying of 3 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 4 core x 2.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, laying of 2 core x 1.5 sq mm copper shielded communication cable with isi mark pvc conduit bundled properly neatly aligned with refrigerant piping well supported at specific intervals as per site requirement and instructions, supply of pvc condensate drain pipe of suitable size for ac indoor units with supports clamps and insulation as required complete with all accessories as per instructions, installation of pvc condensate drain piping for ac indoor units with supports clamps and all accessories as per site requirement and instructions complete as required, supply of ms table top stands for installing outdoor units vrf outdoor 10 units and dx outdoor 1 unit duly epoxy coated including supply of cowl piece for each outdoor machine as required, installation testing and commissioning of ms table top stands for outdoor units including installation testing and commissioning of cowl piece for each outdoor machine as required, supply and filling of refrigerant gas r410a as required for vrf and dx air conditioning systems complete with all accessories as per manufacturer recommendations and site requirements, supply of 4 core x 10 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, supply of 4 core x 16 sq mm copper conductor xlpe insulated pvc sheathed armoured cable 1.1 kv grade conforming to is 7098 part 1 for outdoor unit power supply complete as required, laying testing and commissioning of 4 core x 10 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, laying testing and commissioning of 4 core x 16 sq mm copper xlpe armoured cable 1.1 kv grade from odu power distribution board to outdoor units in cable tray trench on wall through shaft with dressing clamping brass glands aluminium lugs and termination complete, providing fabricating and fixing aluminium anodized partition for air conditioning enclosure using approved aluminium sections with 15 micron anodized finish comprising fixed glazed panels and aluminium framed glazed doors with 5 mm clear float glass door shutters frames floor springs hinges handles locks rubber beading and all accessories, wiring in pvc casing and capping system using 2 x 1.5 sq mm fr pvc insulated copper conductor wire with modular type switches sockets surface mounting plastic frames for light point to be terminated in ceiling rose or batten or angle holder 6 amp 230 volts for led panel light fitting, supply and delivery of recess or surface mounted 2 x 2 luminaire 24 w with 150 lm per watt low glare and cri greater than 90 for hospital ward and corridor lighting as per instructions, installation testing and commissioning of led panel 2 x 2 24 watts to be installed at male and female ward and corridors of hospital as per instructions, supply and delivery of 4 core x 50 sq mm xlpe insulated armoured pvc sheathed heavy duty copper conductor cable 1100 volts grade conforming to is 1554 or is 7098 part 1 of 1988 complete as required, supply and delivery of galvanized iron wire size 8 swg for earthing and cable support as per specifications and instructions, installation charges for fixing and running armoured cables with copper conductors 1100 volts grade on even surfaced walls beams ceilings with appropriate gi saddles and gi spacers with gi wire from central switch chamber to ac power mcbdb at electrical switch room, cable end termination both ends for lv xlpe armoured 4 core x 50 sq mm cable including supply and fixing of double compression cable glands stripping of insulation tinned plated copper lugs for all phases crimping gi nut bolts and washers hdgi 80 micron one set per termination, supply installation testing and commissioning of three pole and neutral distribution board in sheet steel enclosure ip 43 powder coated double door horizontal surface or recess mounting with insulated tinned copper bus bars neutral links din channels earthing terminals 8 way 8 plus 24 way without mcb, supply installation testing and commissioning of four pole isolator 125 amp in suitable enclosure for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 63 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of four pole mcb 40 amp for hvac outdoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole and neutral consumer unit type distribution board in sheet steel enclosure powder coated single door with acrylic window surface or recess mounting with insulated tinned copper bus bar neutral link din channel 12 way 2 plus 10 way without mcb, supply installation testing and commissioning of double pole mcb 32 amp for hvac indoor unit distribution board as per specifications and instructions, supply installation testing and commissioning of single pole mcb 6 or 10 amp for hvac indoor unit distribution board as per specifications and instructions, supply delivery installation testing and commissioning of switch disconnector fuse unit sfu in sheet steel enclosure suitable for din type hrc fuses with isi mark 100amp tpn to be installed at main switch board in electrical switch room, supply installation testing and commissioning of chemical earth electrode for earthing complete with chemical powder 100 mm dia x 3 m long bore frp chamber 500 x 500 x 200 mm with frp cover earthing rod buried vertically 3 m deep resistance tested with calibrated earth resistance meter, comprehensive annual maintenance contract for air conditioning system first year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system second year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system third year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fourth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms, comprehensive annual maintenance contract for air conditioning system fifth year covering all preventive and breakdown maintenance of vrf and dx ac systems including spare parts labour tools and consumables as per contract terms in mumbai, maharashtra,. Reference number 15523994. Don't miss out on this chance to be part of a significant project. Register for free today to access the complete tender details and download the necessary documents. Seize the opportunity with Tender 18!

T18 Ref No:15523994
Tender ID:GEM/2026/B/7586099
Tender Agency:mumbai port trust MPT
City:mumbai
State:maharashtra
Description :total quantity = 18386 ----- document required from seller = experience criteria,past performance,bidder turnover,certificate (requested in atc),oem authorization certificate,additional doc 1 (requested in atc)
Tender Value:Refer Document
Tender EMD:Refer Document
Tender Fee:Refer Document
Published Date:May 26, 2026
Due Date:Jun 25, 2026
Tender Opening Date:Jun 25, 2026
Tender DocumentsDownload Document
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tender Inquiry